arXiv:2609.32554
Wide-Mass-Scanning-Range Setup and Phase-Resolved Protocol for Axion Dark Matter Detection
A. Cottet, T. Kontos
Abstract
We propose a paradigm for quantum enhanced axion dark matter search, which does not rely on power measurements. We propose to measure directly the axion amplitude and phase in an interferometric protocol at the quantum limit, using a non-linear cavity. In addition, we introduce gyromagnetic modes as wide mass range transducers for axion signals compatible with standard haloscope designs. We expect this scheme to offer an improvement of at least 4 orders of magnitude in figure of merit and at least 2 orders of magnitude in mass window with respect to standard haloscopes. Owing to its generality, our proposed protocol has the potential to speed up axion search but also the search for dark photons or other cosmological objects, such as galactic masers.
AI Summary
The paper proposes a phase-sensitive axion haloscope intended to improve detection speed and frequency coverage relative to power-based searches. An axion field drives a magnetic-field-tunable gyromagnetic mode in a crystal such as YIG. Interference with an applied pump changes the mode population; a cross-Kerr coupling converts this change into a frequency shift of a separately driven microwave readout mode, measured through its phase. The analysis derives the gyromagnetic axion coupling from electromagnetic modes and Landau–Lifshitz–Gilbert dynamics, then integrates out the gyromagnetic mode using a Keldysh treatment. Semiclassical response and linearized quantum correlations determine the signal and noise, including pump-induced dephasing. The proposed tuning range is $6.9$–$63\,\mathrm{GHz}$ for fields of $0$–$2\,\mathrm{T}$. For an illustrative $2.7$-litre crystal, $50\,\mathrm{mK}$ temperature, and specified nonlinearities and drives, the predicted unity-SNR integration time is $2.4\,\mu\mathrm{s}$, corresponding to $F\approx0.4\,\mathrm{MHz}$. The maximum predicted SNR is approximately $5.2$ at $0.2\,\mathrm{ms}$. The short-time figure of merit scales as $g_{a\gamma\gamma}^{2}$ rather than the power-readout benchmark’s $g_{a\gamma\gamma}^{4}$. These are theoretical projections, not demonstrated sensitivities. The protocol requires estimating or aligning the initially unknown axion phase within its coherence time. Stated constraints include pump-induced dephasing, readout Kerr nonlinearity and hysteresis, amplifier noise, rapid frequency or phase control, and superconducting-circuit magnetic-field resilience. Higher-order nonlinearities and heating at stronger drives are not modeled. The coupling also weakens toward lower fields and frequencies; currently cited frequency-conversion hardware reaches $23\,\mathrm{GHz}$.
Central claim may not hold: The sensitivity calculation neglects gyromagnetic shot-noise-induced readout phase fluctuations whose variance is enhanced by the approximately two million readout photons, invalidating the stated justification for Eq. (Vres) and the projected detection time. The favorable g^2 detection-rate scaling is established only for a coherence-resolved regime, while the proposed initial-phase estimation has no explicit sensitivity or time budget. The advertised hundredfold improvement in mass-scanning window is not quantitatively benchmarked against a specified conventional-haloscope tuning window. The reported coherence and maximum integration times inconsistently include or omit a factor of 2 pi in the axion linewidth. The displayed phase-maximized signal has an incorrect numerator and consequently predicts a nonzero integrated signal at zero integration time.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Journal reference
- New J. Phys. 28 024504 (2026)
- DOI
- 10.1088/1367-2630/ae4262
- Comments
- The published version has an extensive supplementary material