Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2610.17499

An Aubry-André localized optical lattice clock

Shuo Ma, Anke Stöltzel, Bennett Christensen, Zhuoli Ding, Dhruva Ganapathy, Andrew Householder, Genyue Liu, Shimon Kolkowitz

physics.atom-phquant-phSubmitted Oct 12, 2026• Announced Oct 14, 2026• 0 citations• Revised Oct 14, 2026 (v2)
v1 · Oct 12, 2026v2 · Oct 14, 2026
arXivHTMLPDF

Abstract

Optical lattice clocks in space could improve satellite navigation systems and enable new tests of fundamental physics, including gravitational-wave detection and tests of relativity. In microgravity, atoms can tunnel to degenerate neighboring lattice sites, broadening the clock transition and limiting coherence times. We demonstrate Aubry-André localization in a bichromatic optical lattice formed by two magic-wavelength lasers, suppressing tunneling in a horizontal lattice clock emulating free fall. We recover a Fourier-limited clock Rabi spectrum and measure Ramsey coherence times of up to 2 s in shallow lattices, with up to 100-fold improvement over the delocalized regime. These results establish Aubry-André localization as a practical route to controlling tunneling in future space-based clocks, and open a path to operating terrestrial clocks at shallower lattice depths.

AI Summary

Optical lattice clocks in microgravity lack the gravitational site-energy offsets that suppress atomic tunneling on Earth. This paper tests whether Aubry–André localization can suppress the resulting clock-transition broadening without requiring a deep lattice or time-dependent modulation. The experiment uses a horizontal $^{87}$Sr lattice clock with collinear 813 nm and 497 nm lattices, both tuned to operational magic wavelengths. A weak secondary lattice introduces quasiperiodic site-energy offsets. Rabi spectroscopy shows recovery of a Fourier-limited carrier, with linewidth reductions exceeding an order of magnitude and on-resonance excitation increasing from below 0.1 to above 0.8. The recovery is consistent with the ideal Aubry–André threshold $\Delta/J=2$; continuum-potential calculations incorporating thermal averaging reproduce the spectral trends. Differential Ramsey spectroscopy between two ensembles measures coherence times approaching 2 s, with improvements exceeding two orders of magnitude. A model balancing tunneling, measured Raman scattering, and excited-state decay projects an optimum coherence time of 116.6 s at primary and secondary depths of 16 and 0.13 recoil energies, respectively, versus 36.6 s for a single 813 nm lattice at 100 recoil energies. These are projections assuming ground-band cooling, not demonstrated clock performance. Measured coherence is technically limited by magnetic gradients and vector light shifts. An unexplained fast initial decay may reflect relative lattice-phase noise; higher temperatures require stronger localization, and strong secondary lattices cause heating. Additional systematic uncertainties include motional line pulling and the unmeasured 497 nm hyperpolarizability.

No sign of AI-generated textAI use disclosed
The authors used these models to assist with language refinement and editing for clarity.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Related papers

Optical lattice clock with atoms confined in a shallow trap

P. Lemonde, Peter Wolf

We study the trap depth requirement for the realization of an optical clock using atoms confined in a lattice. We show that site-to-site tunneling leads to a residual sensitivity to the atom dynamics hence requiring large depths [$(50\text{--}100){E}_{r}$ for Sr] to avoid any frequency shift or line broadening of the atomic transition at the ${10}^{\ensuremath{-}17}\text{--}{10}^{\ensuremath{-}18}$ level. Such large depths and the corresponding laser power may, however, lead to difficulties (e.g., higher-order light shifts, two-photon ionization, technical difficulties) and therefore one would like to operate the clock in much shallower traps. To circumvent this problem we propose the use of an accelerated lattice. Acceleration lifts the degeneracy between adjacents potential wells which strongly inhibits tunneling. We show that using the Earth's gravity, much shallower traps (down to $5{E}_{r}$ for Sr) can be used for the same accuracy goal.

arXiv:physics/0504080•Physical Review A•Sep 16, 2005•120 citations

A Multiplexed Strontium Optical Lattice Clock

Jonathan Dolde

Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.

•May 1, 2026•0 citations

Minimizing the required trap depth in optical lattice clocks

P. Lemonde, Peter Wolf

We study the trap depth requirement for the realization of an optical clock using atoms confined in a lattice. We show that site-to-site tunnelling leads to a residual sensitivity to the atom dynamics hence requiring large depths (50 to 100 Erfor Sr) to avoid any frequency shift or line broadening of the atomic transition at the 10-17- 10-18level. Such large depths and the corresponding laser power may, however, lead to difficulties (e.g. higher order light shifts, two-photon ionization, technical difficulties) and therefore one would like to operate the clock in much shallower traps. To circumvent this problem we propose the use of an accelerated lattice. Acceleration lifts the degeneracy between adjacents potential wells which strongly inhibits tunnelling. We show that using the Earth's gravity, much shallower traps (down to 5 Erfor Sr) can be used for the same accuracy goal

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 18, 2006•0 citations

Towards an optical clock for space: Compact, high-performance optical lattice clock based on bosonic atoms

Stefano Origlia, Mysore Srinivas Pramod, Stephan Schiller +9 more

Optical clocks operated on satellites are expected to open up new opportunities in time transfer, geodesy, fundamental physics, and satellite navigation. Here we demonstrate an important first step towards this goal: a modular, compact, optical lattice clock (OLC) system that achieves $2.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ fractional uncertainty. The clock is operated with bosonic strontium and improves the performance of bosonic OLCs by a factor of 30. This has important implications for future use of bosonic OLCs in fundamental physics and metrology. We make use of the clock's metrological performance to measure, with independent clocks, the isotope shift of the $^{1}S_{0}\ensuremath{\rightarrow}^{3}P_{0}$ transitions of $^{88}\mathrm{Sr}$ and $^{87}\mathrm{Sr}$, with an uncertainty of 12 mHz. The ratio of the transition frequencies is thus determined with $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ fractional uncertainty.

arXiv:1803.03157•Physical Review A•Nov 29, 2018•146 citations

Floquet Engineering Hz-Level Rabi Spectra in Shallow Optical Lattice Clock

Mo-Juan Yin, Xiaotong Lu, Ting Li +4 more

Quantum metrology with ultrahigh precision usually requires atoms prepared in an ultrastable environment with well-defined quantum states. Thus, in optical lattice clock systems deep lattice potentials are used to trap ultracold atoms. However, decoherence, induced by Raman scattering and higher order light shifts, can significantly be reduced if atomic clocks are realized in shallow optical lattices. On the other hand, in such lattices, tunneling among different sites can cause additional dephasing and strongly broadening of the Rabi spectrum. Here, in our experiment, we periodically drive a shallow ^{87}Sr optical lattice clock. Counterintuitively, shaking the system can deform the wide broad spectral line into a sharp peak with 5.4 Hz linewidth. With careful comparison between the theory and experiment, we demonstrate that the Rabi frequency and the Bloch bands can be tuned, simultaneously and independently. Our work not only provides a different idea for quantum metrology, such as building shallow optical lattice clock in outer space, but also paves the way for quantum simulation of new phases of matter by engineering exotic spin orbit couplings.

arXiv:2110.07169•Physical Review Letters•Feb 17, 2022•36 citations

An optical lattice clock with neutral strontium

Richard Hobson

Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.

•Jan 1, 2016•9 citations
Optical lattice clocks in space could improve satellite navigation systems and enable new tests of fundamental physics, including gravitational-wave detection and tests of relativity. In microgravity, atoms can tunnel to degenerate neighboring lattice sites, broadening the clock transition and limiting coherence times. We demonstrate Aubry-André localization in a bichromatic optical lattice formed by two magic-wavelength lasers, suppressing tunneling in a horizontal lattice clock emulating free fall. We recover a Fourier-limited clock Rabi spectrum and measure Ramsey coherence times of up to 2 s in shallow lattices, with up to 100-fold improvement over the delocalized regime. These results establish Aubry-André localization as a practical route to controlling tunneling in future space-based clocks, and open a path to operating terrestrial clocks at shallower lattice depths.
Optical lattice clocks in microgravity lack the gravitational site-energy offsets that suppress atomic tunneling on Earth. This paper tests whether Aubry–André localization can suppress the resulting clock-transition broadening without requiring a deep lattice or time-dependent modulation.
The experiment uses a horizontal 87^{87}87Sr lattice clock with collinear 813 nm and 497 nm lattices, both tuned to operational magic wavelengths. A weak secondary lattice introduces quasiperiodic site-energy offsets. Rabi spectroscopy shows recovery of a Fourier-limited carrier, with linewidth reductions exceeding an order of magnitude and on-resonance excitation increasing from below 0.1 to above 0.8. The recovery is consistent with the ideal Aubry–André threshold Δ/J=2\Delta/J=2Δ/J=2; continuum-potential calculations incorporating thermal averaging reproduce the spectral trends. Differential Ramsey spectroscopy between two ensembles measures coherence times approaching 2 s, with improvements exceeding two orders of magnitude.
A model balancing tunneling, measured Raman scattering, and excited-state decay projects an optimum coherence time of 116.6 s at primary and secondary depths of 16 and 0.13 recoil energies, respectively, versus 36.6 s for a single 813 nm lattice at 100 recoil energies. These are projections assuming ground-band cooling, not demonstrated clock performance.
Measured coherence is technically limited by magnetic gradients and vector light shifts. An unexplained fast initial decay may reflect relative lattice-phase noise; higher temperatures require stronger localization, and strong secondary lattices cause heating. Additional systematic uncertainties include motional line pulling and the unmeasured 497 nm hyperpolarizability.
We study the trap depth requirement for the realization of an optical clock using atoms confined in a lattice. We show that site-to-site tunneling leads to a residual sensitivity to the atom dynamics hence requiring large depths [(50–100)Er(50\text{--}100){E}_{r}(50–100)Er​ for Sr] to avoid any frequency shift or line broadening of the atomic transition at the ${10}^{\ensuremath{-}17}\text{--}{10}^{\ensuremath{-}18}$ level. Such large depths and the corresponding laser power may, however, lead to difficulties (e.g., higher-order light shifts, two-photon ionization, technical difficulties) and therefore one would like to operate the clock in much shallower traps. To circumvent this problem we propose the use of an accelerated lattice. Acceleration lifts the degeneracy between adjacents potential wells which strongly inhibits tunneling. We show that using the Earth's gravity, much shallower traps (down to 5Er5{E}_{r}5Er​ for Sr) can be used for the same accuracy goal.
Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.
We study the trap depth requirement for the realization of an optical clock using atoms confined in a lattice. We show that site-to-site tunnelling leads to a residual sensitivity to the atom dynamics hence requiring large depths (50 to 100 Erfor Sr) to avoid any frequency shift or line broadening of the atomic transition at the 10-17- 10-18level. Such large depths and the corresponding laser power may, however, lead to difficulties (e.g. higher order light shifts, two-photon ionization, technical difficulties) and therefore one would like to operate the clock in much shallower traps. To circumvent this problem we propose the use of an accelerated lattice. Acceleration lifts the degeneracy between adjacents potential wells which strongly inhibits tunnelling. We show that using the Earth's gravity, much shallower traps (down to 5 Erfor Sr) can be used for the same accuracy goal
Optical clocks operated on satellites are expected to open up new opportunities in time transfer, geodesy, fundamental physics, and satellite navigation. Here we demonstrate an important first step towards this goal: a modular, compact, optical lattice clock (OLC) system that achieves $2.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ fractional uncertainty. The clock is operated with bosonic strontium and improves the performance of bosonic OLCs by a factor of 30. This has important implications for future use of bosonic OLCs in fundamental physics and metrology. We make use of the clock's metrological performance to measure, with independent clocks, the isotope shift of the $^{1}S_{0}\ensuremath{\rightarrow}^{3}P_{0}$ transitions of 88Sr^{88}\mathrm{Sr}88Sr and 87Sr^{87}\mathrm{Sr}87Sr, with an uncertainty of 12 mHz. The ratio of the transition frequencies is thus determined with $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ fractional uncertainty.
Quantum metrology with ultrahigh precision usually requires atoms prepared in an ultrastable environment with well-defined quantum states. Thus, in optical lattice clock systems deep lattice potentials are used to trap ultracold atoms. However, decoherence, induced by Raman scattering and higher order light shifts, can significantly be reduced if atomic clocks are realized in shallow optical lattices. On the other hand, in such lattices, tunneling among different sites can cause additional dephasing and strongly broadening of the Rabi spectrum. Here, in our experiment, we periodically drive a shallow ^{87}Sr optical lattice clock. Counterintuitively, shaking the system can deform the wide broad spectral line into a sharp peak with 5.4 Hz linewidth. With careful comparison between the theory and experiment, we demonstrate that the Rabi frequency and the Bloch bands can be tuned, simultaneously and independently. Our work not only provides a different idea for quantum metrology, such as building shallow optical lattice clock in outer space, but also paves the way for quantum simulation of new phases of matter by engineering exotic spin orbit couplings.
Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.