Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.38529

Single-particle detection of the Néel transition in LaCrO$_3$ microcrystals via widefield nitrogen-vacancy center magnetic imaging

Carson O. Patterson, Ethan Q. Williams, Eden Tzanetopoulos, Benjamin C. Li, Rachel T. Smith, Matthew Chang, Hideyuki Watanabe, Daniel R. Gamelin, Kai-Mei C. Fu

cond-mat.mtrl-scicond-mat.mes-hallquant-phSubmitted Sep 29, 2026• Announced Oct 1, 2026
arXivHTMLPDF

Abstract

Rare-earth orthochromites exhibit rich, chemically tunable magnetic behavior, making them attractive for temperature sensing and temperature-dependent switching applications. Realizing this potential requires understanding how synthesis conditions and particle morphology influence the underlying Cr$^{3+}$ magnetic ordering. Orthochromite magnetism has traditionally been characterized by ensemble techniques such as neutron diffraction and SQUID magnetometry, which report only averaged magnetic properties and cannot access particle-level information. Here we use widefield nitrogen-vacancy (NV) magnetometry to image the stray magnetic fields of individual LaCrO$_3$ microcrystals produced via molten salt synthesis, resolving the antiferromagnetic Néel transition in single particles. Of the 18 particles measured between 278 and 298 K, five show a clear onset of magnetization near the ensemble Néel temperature, four show no measurable magnetic signal, and nine display temperature-independent signatures consistent with localized magnetic impurities undetected by ensemble measurements. Below the Néel temperature, particle magnetization remains fixed under a rotating in-plane field, consistent with canted antiferromagnetic ordering rather than paramagnetism, while repeated thermal cycling shows that the magnetic field pattern varies between cooldowns with certain features recurring at the same locations, consistent with micron-scale structurally pinned antiferromagnetic domains in which the sign of the weak ferromagnetic moment is set independently each time they pass through the Néel transition. These results establish single-particle NV magnetometry as a sensitive probe of magnetic ordering and domain structure in individual microcrystals, a key step toward correlating individual particle morphology and defect structure with magnetic ordering in orthochromites.

AI Summary

Can single-particle magnetometry distinguish magnetic ordering, impurities, and domain behavior that ensemble measurements average together? This study uses widefield nitrogen-vacancy (NV) magnetic imaging to follow the Néel transition of individual 1%-Yb-doped LaCrO$_3$ microcrystals, approximately 10–50 $\mu$m across. The measured stray field probes the weak ferromagnetic moment associated with spin canting in the antiferromagnetic phase. Eighteen particles were examined between 278 and 298 K, with an estimated field detection threshold of $0.5\,\mu\mathrm{T}$. Five developed magnetic signals near the ensemble transition temperature, $T_N=287$ K; four showed no measurable signal; nine exhibited approximately temperature-independent fields, often spatially localized, consistent with magnetic contamination or inclusions. For transitioning particles, spatially averaged field magnitudes and ODMR linewidths tracked the onset of ordering. The field patterns remained fixed under rotation of an approximately 1 mT applied field, consistent with canted antiferromagnetism rather than paramagnetism. Repeated thermal cycling produced different maps with recurring spatial features, interpreted as micron-scale, structurally pinned domains whose moment signs reset on cooling. The principal limitation is uncertain particle temperature: NV thermometry measures the diamond, and reducing optical excitation tenfold shifted the apparent transition by approximately 3 K. Consequently, the observed several-kelvin transition spread cannot establish intrinsic particle-to-particle variation. Weak signals, uncertain particle–sensor spacing, and two-dimensional projections of three-dimensional magnetization also limit interpretation. Structural pinning and independent domain-sign selection are inferred from recurring maps, not directly established by structural imaging or magnetization reconstruction.

Little sign of AI-generated textIncremental

Error found: The abstract omits that its temperatures are measured in the diamond rather than the particles, whose laser heating and variable thermal contact prevent calibrated individual-particle Néel-temperature measurements.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Related papers

Widefield Quantum Sensor for Vector Magnetic Field Imaging of Micromagnetic Structures

Orlando D. Cunha, Filipe Camarneiro, João P. Silva +4 more

Many spintronic, magnetic-memory, and neuromorphic devices rely on spatially varying magnetic fields. Quantitatively imaging these fields with full vector information over extended areas remains a major challenge. Existing probes either offer nanoscale resolution at the cost of slow scanning, or widefield imaging with limited vector sensitivity or material constraints. Quantum sensing with nitrogen-vacancy (NV) centers in diamond promises to bridge this gap, but a practical camera-based vector magnetometry implementation on relevant microstructures has not been demonstrated. Here we adapt a commercial widefield microscope to implement a camera-compatible pulsed optically detected magnetic resonance protocol to reconstruct stray-field vectors from microscale devices. By resolving the Zeeman shifts of the four NV orientations, we reconstruct the stray-field vector generated by microfabricated permalloy structures that host multiple stable remanent states. Our implementation achieves a spatial resolution of $\approx 0.52 ~μ\mathrm{m}$ across an $83~μ\mathrm{m} \times 83~μ\mathrm{m}$ field of view and a peak sensitivity of $ (828 \pm 142)~\mathrm{nT\,Hz^{-1}}$, with acquisition times of only a few minutes. These results establish pulsed widefield NV magnetometry on standard microscopes as a practical and scalable tool for routine vector-resolved imaging of complex magnetic devices.

quant-pharXiv:2512.03748•Dec 4, 2025

Decoherence imaging of spin ensembles using a scanning single-electron spin in diamond

Lan Luan, M. S. Grinolds, Sungkun Hong +3 more

The nitrogen-vacancy (NV) defect center in diamond has demonstrated great capability for nanoscale magnetic sensing and imaging for both static and periodically modulated target fields. However, it remains a challenge to detect and image randomly fluctuating magnetic fields. Recent theoretical and numerical works have outlined detection schemes that exploit changes in decoherence of the detector spin as a sensitive measure for fluctuating fields. Here we experimentally monitor the decoherence of a scanning NV center in order to image the fluctuating magnetic fields from paramagnetic impurities on an underlying diamond surface. We detect a signal corresponding to roughly 800 μB in 2 s of integration time, without any control on the target spins, and obtain magnetic-field spectral information using dynamical decoupling techniques. The extracted spatial and temporal properties of the surface paramagnetic impurities provide insight to prolonging the coherence of near-surface qubits for quantum information and metrology applications.

arXiv:1409.5418•Scientific Reports•Jan 29, 2015•47 citations

Elucidating magnetic structure with optical dopants: erbium-doped Gd$_2$SiO$_5$

Luke S. Trainor, Masaya Hiraishi, J. -R. Soh +1 more

The narrowness of the optical transitions of rare-earth-ion dopants makes them highly sensitive probes of their environment. We measured the optical transitions Er$^{3+}$ dopants to determine the previously unknown magnetic ordering of Gd$_{2}$SiO$_{5}$ -- a promising host for quantum applications of rare-earth dopants. By measuring the transitions' magnetic-field dependence we determined an antiferromagnetic ordering with spins oriented along or slightly canted from the crystal's $a^*$ axis. The optical transitions are narrower than the coupling to gadolinium spins revealing information about the coupling strengths. We further optically measured a Néel temperature of $1.86\pm0.01_\mathrm{stat.}\pm0.07_\mathrm{syst.}$ K, and assembled a phase diagram in applied field and temperature showcasing a triple point where two gadolinium sites order semi-independently from each other. At high applied field the erbium dopants show long optical coherence times up to 0.4 ms at 3 T; at low fields these are probably limited by three low-frequency magnon modes below 10 GHz, observed directly. This study can be used to benchmark a method of magnetic structure determination.

cond-mat.str-elCross-listedarXiv:2603.12603•Mar 16, 2026•0 citations

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Feb 8, 2021•1 citation

Investigation of Widefield NV-Center Magnetic Imaging for Non-Destructive Materials Testing

Niklas Mathes, Marvin Feuerhelm, Simon Philipp +7 more

Due to progressing miniaturization, material fatigue is expected to gain importance on microscopic scales. Nevertheless, most non-destructive testing techniques are optimized for macroscopic scales. Therefore, new approaches applicable to miniaturized samples need to be explored. High spatial resolution imaging of a material's magnetic stray field enables sensitive detection of microstructural changes due to the local interplay of magnetic properties, strain, and defects. Up to now, this approach has rarely been used for materials testing since high-resolution magnetic sensing is traditionally challenging. Novel quantum sensing techniques offer the potential to close this gap. One of the most prominent quantum sensors, the nitrogen vacancy center in diamond, is investigated for non-destructive testing applications within the scope of this work. An experimental system based on a widefield sensing approach was developed to image magnetic stray field distributions within seconds to minutes over areas up to 1 x 1 $mm^2$. Magnetic sensitivities below 10 $μ$T/$\sqrt{\text{Hz}}$ and a spatial resolution of 1-2 $μ$m were achieved. The technique offers high mechanical stability, which is crucial for non-destructive testing applications. Comparison with magneto-optical Kerr effect measurements showed that the magnetic field maps are strongly correlated with the material's surface domains while containing additional information from deeper inside the sample. Characteristic changes in the magnetic stray field distribution were detected in an electrical steel sample after cyclic loading. A potential marker for early fatigue damage was deduced from the splitting gradient distribution, while 2D Fourier transform analysis provided additional insight.

physics.ins-detCross-listedarXiv:2609.27097•Sep 24, 2026

Massively Multiplexed Nanoscale Magnetometry with Diamond Quantum Sensors

Kai-Hung Cheng, Zeeshawn Kazi, Jared Rovny +4 more

Single nitrogen vacancy (NV) centers in diamond have been used extensively for high-sensitivity nanoscale sensing, but conventional approaches use confocal microscopy to measure individual centers sequentially, limiting throughput and access to nonlocal physical properties, where simultaneous, high-fidelity measurement of multiple centers is required. Here, we design and implement a multiplexed NV sensing platform that allows us to read out many single NV centers simultaneously using a low-noise camera. Using this platform, we coherently manipulate and read out the spin states of hundreds of individual NV centers in parallel, achieving comparable magnetic field sensitivity to confocal measurements. We also implement a parallelized version of spin-to-charge-conversion readout for low NV center spin state readout noise and use it to demonstrate multiplexed covariance magnetometry, in which we measure ten two-point magnetic field correlators from five NV centers simultaneously. From these measurements, we demonstrate the quantitative reconstruction of spatially varying magnetic correlations arising from a current-carrying wire. The number of correlators we can measure is limited only by the available laser power, opening the door to massively multiplexed covariance magnetometry. In contrast to scanning probes for imaging spatially varying magnetic fields, our approach measures the temporal dynamics of the magnetic field at many precisely defined positions simultaneously, from which the local noise spectrum and nonlocal properties such as correlation functions can be computed. This high-fidelity readout platform will find immediate applications in studying condensed matter phenomena that are characterized by the noise spectrum or correlation functions, including quantum phase transitions, dynamics far from equilibrium, magnetic order, and correlated electron phenomena.

arXiv:2408.11666•Physical Review X•May 22, 2025•21 citations
Single-particle detection of the Néel transition in LaCrO3_33​ microcrystals via widefield nitrogen-vacancy center magnetic imaging
Rare-earth orthochromites exhibit rich, chemically tunable magnetic behavior, making them attractive for temperature sensing and temperature-dependent switching applications. Realizing this potential requires understanding how synthesis conditions and particle morphology influence the underlying Cr3+^{3+}3+ magnetic ordering. Orthochromite magnetism has traditionally been characterized by ensemble techniques such as neutron diffraction and SQUID magnetometry, which report only averaged magnetic properties and cannot access particle-level information. Here we use widefield nitrogen-vacancy (NV) magnetometry to image the stray magnetic fields of individual LaCrO3_33​ microcrystals produced via molten salt synthesis, resolving the antiferromagnetic Néel transition in single particles. Of the 18 particles measured between 278 and 298 K, five show a clear onset of magnetization near the ensemble Néel temperature, four show no measurable magnetic signal, and nine display temperature-independent signatures consistent with localized magnetic impurities undetected by ensemble measurements. Below the Néel temperature, particle magnetization remains fixed under a rotating in-plane field, consistent with canted antiferromagnetic ordering rather than paramagnetism, while repeated thermal cycling shows that the magnetic field pattern varies between cooldowns with certain features recurring at the same locations, consistent with micron-scale structurally pinned antiferromagnetic domains in which the sign of the weak ferromagnetic moment is set independently each time they pass through the Néel transition. These results establish single-particle NV magnetometry as a sensitive probe of magnetic ordering and domain structure in individual microcrystals, a key step toward correlating individual particle morphology and defect structure with magnetic ordering in orthochromites.
Can single-particle magnetometry distinguish magnetic ordering, impurities, and domain behavior that ensemble measurements average together? This study uses widefield nitrogen-vacancy (NV) magnetic imaging to follow the Néel transition of individual 1%-Yb-doped LaCrO3_33​ microcrystals, approximately 10–50 μ\muμm across. The measured stray field probes the weak ferromagnetic moment associated with spin canting in the antiferromagnetic phase.
Eighteen particles were examined between 278 and 298 K, with an estimated field detection threshold of 0.5 μT0.5\,\mu\mathrm{T}0.5μT. Five developed magnetic signals near the ensemble transition temperature, TN=287T_N=287TN​=287 K; four showed no measurable signal; nine exhibited approximately temperature-independent fields, often spatially localized, consistent with magnetic contamination or inclusions. For transitioning particles, spatially averaged field magnitudes and ODMR linewidths tracked the onset of ordering. The field patterns remained fixed under rotation of an approximately 1 mT applied field, consistent with canted antiferromagnetism rather than paramagnetism. Repeated thermal cycling produced different maps with recurring spatial features, interpreted as micron-scale, structurally pinned domains whose moment signs reset on cooling.
The principal limitation is uncertain particle temperature: NV thermometry measures the diamond, and reducing optical excitation tenfold shifted the apparent transition by approximately 3 K. Consequently, the observed several-kelvin transition spread cannot establish intrinsic particle-to-particle variation. Weak signals, uncertain particle–sensor spacing, and two-dimensional projections of three-dimensional magnetization also limit interpretation. Structural pinning and independent domain-sign selection are inferred from recurring maps, not directly established by structural imaging or magnetization reconstruction.
Many spintronic, magnetic-memory, and neuromorphic devices rely on spatially varying magnetic fields. Quantitatively imaging these fields with full vector information over extended areas remains a major challenge. Existing probes either offer nanoscale resolution at the cost of slow scanning, or widefield imaging with limited vector sensitivity or material constraints. Quantum sensing with nitrogen-vacancy (NV) centers in diamond promises to bridge this gap, but a practical camera-based vector magnetometry implementation on relevant microstructures has not been demonstrated. Here we adapt a commercial widefield microscope to implement a camera-compatible pulsed optically detected magnetic resonance protocol to reconstruct stray-field vectors from microscale devices. By resolving the Zeeman shifts of the four NV orientations, we reconstruct the stray-field vector generated by microfabricated permalloy structures that host multiple stable remanent states. Our implementation achieves a spatial resolution of ≈0.52 μm\approx 0.52 ~μ\mathrm{m}≈0.52 μm across an 83 μm×83 μm83~μ\mathrm{m} \times 83~μ\mathrm{m}83 μm×83 μm field of view and a peak sensitivity of $ (828 \pm 142)~\mathrm{nT\,Hz^{-1}}$, with acquisition times of only a few minutes. These results establish pulsed widefield NV magnetometry on standard microscopes as a practical and scalable tool for routine vector-resolved imaging of complex magnetic devices.
The nitrogen-vacancy (NV) defect center in diamond has demonstrated great capability for nanoscale magnetic sensing and imaging for both static and periodically modulated target fields. However, it remains a challenge to detect and image randomly fluctuating magnetic fields. Recent theoretical and numerical works have outlined detection schemes that exploit changes in decoherence of the detector spin as a sensitive measure for fluctuating fields. Here we experimentally monitor the decoherence of a scanning NV center in order to image the fluctuating magnetic fields from paramagnetic impurities on an underlying diamond surface. We detect a signal corresponding to roughly 800 μB in 2 s of integration time, without any control on the target spins, and obtain magnetic-field spectral information using dynamical decoupling techniques. The extracted spatial and temporal properties of the surface paramagnetic impurities provide insight to prolonging the coherence of near-surface qubits for quantum information and metrology applications.
Elucidating magnetic structure with optical dopants: erbium-doped Gd2_22​SiO5_55​
The narrowness of the optical transitions of rare-earth-ion dopants makes them highly sensitive probes of their environment. We measured the optical transitions Er3+^{3+}3+ dopants to determine the previously unknown magnetic ordering of Gd2_{2}2​SiO5_{5}5​ -- a promising host for quantum applications of rare-earth dopants. By measuring the transitions' magnetic-field dependence we determined an antiferromagnetic ordering with spins oriented along or slightly canted from the crystal's a∗a^*a∗ axis. The optical transitions are narrower than the coupling to gadolinium spins revealing information about the coupling strengths. We further optically measured a Néel temperature of 1.86±0.01stat.±0.07syst.1.86\pm0.01_\mathrm{stat.}\pm0.07_\mathrm{syst.}1.86±0.01stat.​±0.07syst.​ K, and assembled a phase diagram in applied field and temperature showcasing a triple point where two gadolinium sites order semi-independently from each other. At high applied field the erbium dopants show long optical coherence times up to 0.4 ms at 3 T; at low fields these are probably limited by three low-frequency magnon modes below 10 GHz, observed directly. This study can be used to benchmark a method of magnetic structure determination.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.
Due to progressing miniaturization, material fatigue is expected to gain importance on microscopic scales. Nevertheless, most non-destructive testing techniques are optimized for macroscopic scales. Therefore, new approaches applicable to miniaturized samples need to be explored. High spatial resolution imaging of a material's magnetic stray field enables sensitive detection of microstructural changes due to the local interplay of magnetic properties, strain, and defects. Up to now, this approach has rarely been used for materials testing since high-resolution magnetic sensing is traditionally challenging. Novel quantum sensing techniques offer the potential to close this gap. One of the most prominent quantum sensors, the nitrogen vacancy center in diamond, is investigated for non-destructive testing applications within the scope of this work. An experimental system based on a widefield sensing approach was developed to image magnetic stray field distributions within seconds to minutes over areas up to 1 x 1 mm2mm^2mm2. Magnetic sensitivities below 10 μμμT/Hz\sqrt{\text{Hz}}Hz​ and a spatial resolution of 1-2 μμμm were achieved. The technique offers high mechanical stability, which is crucial for non-destructive testing applications. Comparison with magneto-optical Kerr effect measurements showed that the magnetic field maps are strongly correlated with the material's surface domains while containing additional information from deeper inside the sample. Characteristic changes in the magnetic stray field distribution were detected in an electrical steel sample after cyclic loading. A potential marker for early fatigue damage was deduced from the splitting gradient distribution, while 2D Fourier transform analysis provided additional insight.
Single nitrogen vacancy (NV) centers in diamond have been used extensively for high-sensitivity nanoscale sensing, but conventional approaches use confocal microscopy to measure individual centers sequentially, limiting throughput and access to nonlocal physical properties, where simultaneous, high-fidelity measurement of multiple centers is required. Here, we design and implement a multiplexed NV sensing platform that allows us to read out many single NV centers simultaneously using a low-noise camera. Using this platform, we coherently manipulate and read out the spin states of hundreds of individual NV centers in parallel, achieving comparable magnetic field sensitivity to confocal measurements. We also implement a parallelized version of spin-to-charge-conversion readout for low NV center spin state readout noise and use it to demonstrate multiplexed covariance magnetometry, in which we measure ten two-point magnetic field correlators from five NV centers simultaneously. From these measurements, we demonstrate the quantitative reconstruction of spatially varying magnetic correlations arising from a current-carrying wire. The number of correlators we can measure is limited only by the available laser power, opening the door to massively multiplexed covariance magnetometry. In contrast to scanning probes for imaging spatially varying magnetic fields, our approach measures the temporal dynamics of the magnetic field at many precisely defined positions simultaneously, from which the local noise spectrum and nonlocal properties such as correlation functions can be computed. This high-fidelity readout platform will find immediate applications in studying condensed matter phenomena that are characterized by the noise spectrum or correlation functions, including quantum phase transitions, dynamics far from equilibrium, magnetic order, and correlated electron phenomena.