arXiv:2609.31913
Gate Synthesis in Dephasing-Limited Nitrogen-Vacancy Ensembles
Ankita Chakravarty, Arnaud Carignan-Dugas, Eva Dupont-Ferrier, Yves Bérubé-Lauzière
Abstract
Ensemble nitrogen-vacancy (NV) centers are widely used for quantum sensing and magnetometry, where performance depends on the accurate implementation of microwave pulse sequences. In these systems, inhomogeneous broadening and short coherence times limit reliable multi-pulse control, while hardware imperfections and off-resonant excitation distort implemented rotations, making direct calibration of arbitrary gates tedious. To address this, we implement a control framework with a ZXZXZ gate decomposition which uses fixed-angle, phase-parameterized pulses, enabling universal single-qubit control from a single calibrated $ π/2$ primitive ($X_{π/2}$) along with virtual Z operations. We compare a standard pulse with a composite pulse designed for high-power operation in a regime where the Rabi frequency is comparable to the hyperfine splitting, leading to non-uniform evolution across hyperfine levels. Using pre-determined combinations of $π/2$ pulse sequences, we observe that standard pulses rapidly deviate from ideal behavior under repeated application, while the composite pulse suppresses this error accumulation by more than 70$\%$ for longer sequences despite its longer duration. In contrast, randomized benchmarking yields similar decay factors for both implementations, highlighting its limited sensitivity to coherent control errors. These results establish a practical route to robust control in short-coherence ensemble systems and emphasize the importance of pulse-level characterization.
AI Summary
The paper studies how microwave control errors accumulate in NV ensembles when short dephasing times require fast pulses with Rabi frequencies comparable to the nitrogen hyperfine splitting. The experimental platform has $T_2^*\sim1\,\mu\mathrm{s}$, maximum Rabi frequency approximately $3$ MHz, and hyperfine splitting approximately $2.16$ MHz. Single-qubit gates are synthesized using a ZXZXZ decomposition with two fixed calibrated pulse primitives and virtual $Z$ rotations. Experiments compare a standard 54 ns rectangular $\pi/2$ pulse against an empirically calibrated 174 ns composite primitive comprising opposite-amplitude 60 ns segments followed by a 54 ns wait. All combinations of two, three, and four $X_{\pm\pi/2}$ and $Y_{\pm\pi/2}$ gates—16, 64, and 256 circuits—are compared with ideal simulations. For standard pulses, signal mean-squared errors are $0.0062$, $0.0289$, and $0.054$; composite pulses give $0.0059$, $0.0050$, and $0.0156$, corresponding to approximately 83% and 71% reductions for three- and four-gate circuits. Randomized benchmarking instead gives similar fitted decay parameters, approximately $0.98$ and $0.97$, despite the composite primitive’s longer duration. This contrast illustrates the different sensitivity of randomized and structured sequences to coherent errors. The paper notes that fitted benchmarking parameters depend on the sequence-length range, so a single exponential does not fully describe the data. Gate-level simulations provide qualitative rather than quantitative agreement because they omit ensemble inhomogeneity and other experimental effects. Simulations also indicate that composite-pulse improvements depend on specific compensation conditions rather than uniform robustness across calibration errors.
Central claim may not hold: The specified composite pulse cancels exactly on the resonant hyperfine component under the stated Hamiltonian, so its claimed resonant π/2 action requires additional dynamics that the paper does not specify. The synthesis argument assumes a single unitary primitive rather than the experimentally described ensemble mixture, and its printed G_decomposition additionally has an incorrect final Z angle that fails even at θ=0. The reported 83% and 71% improvements are signal-MSE reductions rather than isolated coherent-error reductions, and the two- and three-gate characterization families overlap the calibration objective. Similar RB decay factors do not isolate insensitivity to coherent errors because composite gates are 3.22 times longer and the extracted parameters depend on the fitting range. The reported standard-pulse dephasing contribution of 50% should be about 33% when calculated without premature rounding from the stated gate duration, coherence time, and RB parameter.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 12 pages, 8 figures