Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.17787

Superconducting levitation and control of a high-reflectivity micromirror

Philipp Koller, Jannek J. Hansen, David Walcher, Tomáš Plichta, Rémi Claessen, Martin Žemlička, Philip Schmidt, Rhys G. Povey, Stefan Minniberger, Stefan Putz, Markus Aspelmeyer, Michael Trupke

quant-phSubmitted Sep 15, 2026• Announced Sep 17, 2026
arXivHTMLPDF

Abstract

We introduce a method to suspend an optical micromirror, with a total mass of \SI{30}{\micro\gram}, using superconducting magnetic levitation. The micromirror is formed on a silicon membrane, coated with a high-reflectivity dielectric stack and attached to superconducting microspheres. The object is stably levitated inside a magnetic quadrupole field at cryogenic temperatures. Magnetic feedback on the transverse motion is used to stabilize the position of the levitator within the trapping field, allowing to measure the axial displacement of the levitator using optical interferometry. The system reaches a sensitivity of order \SI{100}{\pico\metre/\sqrt{\hertz}} near the axial trap frequency of \SI{167}{Hz}. This approach enables free-standing mirrors with minimal dissipation and tunable oscillation frequencies, offering a platform for precision sensing and quantum cavity optomechanics in the microgram regime.

AI Summary

The paper investigates whether superconducting magnetic levitation can suspend a high-reflectivity micromirror without mechanical clamping while permitting optical displacement readout. A microfabricated concave silicon mirror with a localized dielectric Bragg coating is attached to four press-fitted PbSn superconducting spheres, giving a total mass of approximately $30\,\mu\mathrm{g}$. The assembly is levitated in a superconducting anti-Helmholtz trap at $3.2\,\mathrm{K}$. Camera-based magnetic feedback followed by feedback using position-dependent reflected intensity reduces transverse oscillations from tens of micrometres to below approximately $1\,\mu\mathrm{m}$, enabling homodyne detection of axial motion. At an axial resonance near $167\,\mathrm{Hz}$, the displacement noise floor is approximately $100\,\mathrm{pm}/\sqrt{\mathrm{Hz}}$, falling to $16\,\mathrm{pm}/\sqrt{\mathrm{Hz}}$ at $1\,\mathrm{kHz}$ with approximately $10\,\mathrm{pW}$ detected power. Frequency stability and measurement resolution establish only a lower bound $Q\geq1500$. Separately, a room-temperature cavity measurement using an unreleased mirror establishes finesse exceeding $10^4$; a high-finesse cavity containing the levitated mirror is not demonstrated. Levitation lasts up to approximately $600\,\mathrm{s}$ without probe illumination, while several nanowatts of probe power permit tens of seconds. Lifetime measurements versus aperture size, trap current and probe power support heating-induced superconducting quenching as the limiting mechanism. Heating also produces an axial-frequency drift of approximately $-42.3\,\mathrm{mHz/s}$. Readout remains limited by technical interferometer noise, laser-frequency noise and cryocooler vibrations. Residual transverse motion can move illumination onto uncoated silicon, accelerating heating. Ground-state cooling and cavity-enhanced readout remain proposed extensions.

Little sign of AI-generated textOverclaims

Error found: The paper equates several nanowatts at 637 nm with approximately 3×10^11 photons/s, although that flux corresponds to approximately 94 nW. The stated 10 pW detected power implies an ideal single-sided homodyne displacement shot-noise floor of approximately 6.3 pm/√Hz at 637 nm, rather than the quoted 2.5 pm/√Hz, with no explanation of the discrepancy.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Related papers

Optical interferometric readout of a magnetically levitated superconducting microsphere

Jannek J. Hansen, Stefan Minniberger, Dominik Ilk +8 more

We probe the motion of a 6- μ g magnetically levitated superconducting microsphere using optical interferometry at 3 K , achieving a resolution of the order of 1 nm / Hz , and use the measured signal to feedback-cool its motion. The resolution exceeds the shot-noise limit of 11 pm / Hz primarily due to technical noise arising from the roughness of the particle, in combination with its free rotation. These measurements demonstrate that the combination of interferometric optical readout and superconducting magnetic levitation, together with established techniques of cavity optomechanics, provides all the ingredients required for quantum physics experiments with microgram masses.

arXiv:2508.11731•Physical Review Applied•Mar 27, 2026•2 citations

On-chip levitation of ferromagnetic microparticles

Martijn Janse, M. Luisa Mattana, Julian van Doorn +4 more

Levitation of microscopic objects in vacuum combines exceptional environmental isolation with precise control of their dynamics, pushing the limits of sensing and macroscopic quantum physics. In particular, magnetic levitation allows a large range of particle sizes, while avoiding detrimental effects from high-intensity optical trapping beams and electric field noise. However, existing diamagnetic and Meissner levitation approaches are typically constrained by low mechanical eigenfrequencies, limited integrability with other systems due to bulky coils or magnets, and, for Meissner levitation, the need for cryogenic operation. Here, we demonstrate a room-temperature on-chip magnetic levitation platform capable of stably levitating a nanogram (6.5 micrometer radius) ferromagnetic microsphere. The platform is scalable and tunable, and supports librational modes with eigenfrequencies exceeding 10 kHz. Further miniaturization and coupling to solid-state spin qubits could enable cooling to the quantum ground state. Beyond quantum experiments, this architecture enables integrated precision sensing and studies of isolated ferromagnet thermodynamics.

quant-pharXiv:2605.00090•May 4, 2026

High- Q Magnetic Levitation and Control of Superconducting Microspheres at Millikelvin Temperatures

Joachim Hofer, R. Gross, Gerard T. Higgins +11 more

We report the levitation of a superconducting lead-tin sphere with 100 μm diameter (corresponding to a mass of 5.6 μg) in a static magnetic trap formed by two coils in an anti-Helmholtz configuration, with adjustable resonance frequencies up to 240 Hz. The center-of-mass motion of the sphere is monitored magnetically using a dc superconducting quantum interference device as well as optically and exhibits quality factors of up to 2.6×10^{7}. We also demonstrate 3D magnetic feedback control of the motion of the sphere. The setup is housed in a dilution refrigerator operating at 15 mK. By implementing a cryogenic vibration isolation system, we can attenuate environmental vibrations at 200 Hz by approximately 7 orders of magnitude. The combination of low temperature, large mass, and high quality factor provides a promising platform for testing quantum physics in previously unexplored regimes with high mass and long coherence times.

arXiv:2211.06289•Physical Review Letters•Jul 25, 2023•72 citations

Remote sensing of a levitated superconductor with a flux-tunable microwave cavity

Philip Schmidt, Remi Claessen, Gerard T. Higgins +10 more

We present a cavity-electromechanical system comprising a superconducting quantum interference device which is embedded in a microwave resonator and coupled via a pickup loop to a 6 - μ g magnetically levitated superconducting sphere. The motion of the sphere in the magnetic trap induces a frequency shift in the SQUID-cavity system. We use microwave spectroscopy to characterize the system, and we demonstrate that the electromechanical interaction is tunable. The measured displacement sensitivity of 10 − 7 m / Hz defines a path towards ground-state cooling of levitated particles with Planck-scale masses at millikelvin environment temperatures. Published by the American Physical Society 2024

arXiv:2401.08854•Physical Review Applied•Jul 30, 2024•16 citations

A Chip-Based Superconducting Magnetic Trap for Levitating Superconducting Microparticles

Martí Gutierrez Latorre, Achintya Paradkar, David Hambraeus +2 more

Magnetically-levitated superconducting microparticles have been recently proposed as a promising platform for performing quantum experiments with particles in the picogram regime. Here, we demonstrate the superconducting technology to achieve chip-based magnetic levitation of superconducting microparticles. We simulate and fabricate a chip-based magnetic trap capable of levitating superconducting particles with diameters from 0.5$\,\mu$m to 200$\,\mu$m. The trap consists of two stacked silicon chips, each patterned with a planar multi-winding superconducting coil made of niobium. The two coils generate a magnetic field resembling a quadrupole near the trap center, in which we demonstrate trapping of a spherical 50$\mu$m diameter SnPb microparticle at temperatures of 4 K and 40 mK.

arXiv:2109.15071•IEEE Transactions on Applied Superconductivity•Feb 1, 2022•19 citations

Picometer control of a levitating milligram gravity sensor

Dennis G. Uitenbroek, Jurriaan Langendorff, Tjerk H. Oosterkamp

Due to their exceptional isolation from the environment, magnetically levitated particles are explored as extremely sensitive mechanical sensors. For future gravity experiments on quantum superpositions, such systems need to be cooled close to their ground state. To demonstrate the combination of state of the art vibration isolation, milligram levitated high Q mechanical resonators and position detection with low noise, we present linear feedback cooling of a magnetically levitated gravity sensor to below 2 picometer amplitude and below 10 millikelvin mode temperature for two translational modes (the x- and y-mode) simultaneously. The sensor is a levitating permanent magnet in a type I superconducting trap, where its six resonance frequencies are measured with a superconducting coil coupled to a DC SQUID. This signal is measured with a lock-in amplifier and a feedback signal is sent to a piezoelectric actuator, allowing the cooling of resonant modes at 50.6 and 68.0 Hz simultaneously. These two translational modes have Q factors of $3.8 \cdot 10^6$ and $5.5 \cdot 10^6$ respectively. The experiment is mounted inside a dry dilution refrigerator where it is vibrationally attenuated with 110-130 dB at these frequencies. In this work, we discuss future improvements on the setup which may enable quantum ground state cooling on a magnetically levitated particle, that has previously been shown to be a gravitational sensor.

quant-pharXiv:2605.28479•May 28, 2026
We introduce a method to suspend an optical micromirror, with a total mass of \SI{30}{\micro\gram}, using superconducting magnetic levitation. The micromirror is formed on a silicon membrane, coated with a high-reflectivity dielectric stack and attached to superconducting microspheres. The object is stably levitated inside a magnetic quadrupole field at cryogenic temperatures. Magnetic feedback on the transverse motion is used to stabilize the position of the levitator within the trapping field, allowing to measure the axial displacement of the levitator using optical interferometry. The system reaches a sensitivity of order \SI{100}{\pico\metre/\sqrt{\hertz}} near the axial trap frequency of \SI{167}{Hz}. This approach enables free-standing mirrors with minimal dissipation and tunable oscillation frequencies, offering a platform for precision sensing and quantum cavity optomechanics in the microgram regime.
The paper investigates whether superconducting magnetic levitation can suspend a high-reflectivity micromirror without mechanical clamping while permitting optical displacement readout. A microfabricated concave silicon mirror with a localized dielectric Bragg coating is attached to four press-fitted PbSn superconducting spheres, giving a total mass of approximately 30 μg30\,\mu\mathrm{g}30μg. The assembly is levitated in a superconducting anti-Helmholtz trap at 3.2 K3.2\,\mathrm{K}3.2K.
Camera-based magnetic feedback followed by feedback using position-dependent reflected intensity reduces transverse oscillations from tens of micrometres to below approximately 1 μm1\,\mu\mathrm{m}1μm, enabling homodyne detection of axial motion. At an axial resonance near 167 Hz167\,\mathrm{Hz}167Hz, the displacement noise floor is approximately 100 pm/Hz100\,\mathrm{pm}/\sqrt{\mathrm{Hz}}100pm/Hz​, falling to 16 pm/Hz16\,\mathrm{pm}/\sqrt{\mathrm{Hz}}16pm/Hz​ at 1 kHz1\,\mathrm{kHz}1kHz with approximately 10 pW10\,\mathrm{pW}10pW detected power. Frequency stability and measurement resolution establish only a lower bound Q≥1500Q\geq1500Q≥1500. Separately, a room-temperature cavity measurement using an unreleased mirror establishes finesse exceeding 10410^4104; a high-finesse cavity containing the levitated mirror is not demonstrated.
Levitation lasts up to approximately 600 s600\,\mathrm{s}600s without probe illumination, while several nanowatts of probe power permit tens of seconds. Lifetime measurements versus aperture size, trap current and probe power support heating-induced superconducting quenching as the limiting mechanism. Heating also produces an axial-frequency drift of approximately −42.3 mHz/s-42.3\,\mathrm{mHz/s}−42.3mHz/s. Readout remains limited by technical interferometer noise, laser-frequency noise and cryocooler vibrations. Residual transverse motion can move illumination onto uncoated silicon, accelerating heating. Ground-state cooling and cavity-enhanced readout remain proposed extensions.
We probe the motion of a 6- μ g magnetically levitated superconducting microsphere using optical interferometry at 3 K , achieving a resolution of the order of 1 nm / Hz , and use the measured signal to feedback-cool its motion. The resolution exceeds the shot-noise limit of 11 pm / Hz primarily due to technical noise arising from the roughness of the particle, in combination with its free rotation. These measurements demonstrate that the combination of interferometric optical readout and superconducting magnetic levitation, together with established techniques of cavity optomechanics, provides all the ingredients required for quantum physics experiments with microgram masses.
Levitation of microscopic objects in vacuum combines exceptional environmental isolation with precise control of their dynamics, pushing the limits of sensing and macroscopic quantum physics. In particular, magnetic levitation allows a large range of particle sizes, while avoiding detrimental effects from high-intensity optical trapping beams and electric field noise. However, existing diamagnetic and Meissner levitation approaches are typically constrained by low mechanical eigenfrequencies, limited integrability with other systems due to bulky coils or magnets, and, for Meissner levitation, the need for cryogenic operation. Here, we demonstrate a room-temperature on-chip magnetic levitation platform capable of stably levitating a nanogram (6.5 micrometer radius) ferromagnetic microsphere. The platform is scalable and tunable, and supports librational modes with eigenfrequencies exceeding 10 kHz. Further miniaturization and coupling to solid-state spin qubits could enable cooling to the quantum ground state. Beyond quantum experiments, this architecture enables integrated precision sensing and studies of isolated ferromagnet thermodynamics.
We report the levitation of a superconducting lead-tin sphere with 100 μm diameter (corresponding to a mass of 5.6 μg) in a static magnetic trap formed by two coils in an anti-Helmholtz configuration, with adjustable resonance frequencies up to 240 Hz. The center-of-mass motion of the sphere is monitored magnetically using a dc superconducting quantum interference device as well as optically and exhibits quality factors of up to 2.6×10^{7}. We also demonstrate 3D magnetic feedback control of the motion of the sphere. The setup is housed in a dilution refrigerator operating at 15 mK. By implementing a cryogenic vibration isolation system, we can attenuate environmental vibrations at 200 Hz by approximately 7 orders of magnitude. The combination of low temperature, large mass, and high quality factor provides a promising platform for testing quantum physics in previously unexplored regimes with high mass and long coherence times.
We present a cavity-electromechanical system comprising a superconducting quantum interference device which is embedded in a microwave resonator and coupled via a pickup loop to a 6 - μ g magnetically levitated superconducting sphere. The motion of the sphere in the magnetic trap induces a frequency shift in the SQUID-cavity system. We use microwave spectroscopy to characterize the system, and we demonstrate that the electromechanical interaction is tunable. The measured displacement sensitivity of 10 − 7 m / Hz defines a path towards ground-state cooling of levitated particles with Planck-scale masses at millikelvin environment temperatures. Published by the American Physical Society 2024
Magnetically-levitated superconducting microparticles have been recently proposed as a promising platform for performing quantum experiments with particles in the picogram regime. Here, we demonstrate the superconducting technology to achieve chip-based magnetic levitation of superconducting microparticles. We simulate and fabricate a chip-based magnetic trap capable of levitating superconducting particles with diameters from 0.5 μ\,\muμm to 200 μ\,\muμm. The trap consists of two stacked silicon chips, each patterned with a planar multi-winding superconducting coil made of niobium. The two coils generate a magnetic field resembling a quadrupole near the trap center, in which we demonstrate trapping of a spherical 50μ\muμm diameter SnPb microparticle at temperatures of 4 K and 40 mK.
Due to their exceptional isolation from the environment, magnetically levitated particles are explored as extremely sensitive mechanical sensors. For future gravity experiments on quantum superpositions, such systems need to be cooled close to their ground state. To demonstrate the combination of state of the art vibration isolation, milligram levitated high Q mechanical resonators and position detection with low noise, we present linear feedback cooling of a magnetically levitated gravity sensor to below 2 picometer amplitude and below 10 millikelvin mode temperature for two translational modes (the x- and y-mode) simultaneously. The sensor is a levitating permanent magnet in a type I superconducting trap, where its six resonance frequencies are measured with a superconducting coil coupled to a DC SQUID. This signal is measured with a lock-in amplifier and a feedback signal is sent to a piezoelectric actuator, allowing the cooling of resonant modes at 50.6 and 68.0 Hz simultaneously. These two translational modes have Q factors of 3.8⋅1063.8 \cdot 10^63.8⋅106 and 5.5⋅1065.5 \cdot 10^65.5⋅106 respectively. The experiment is mounted inside a dry dilution refrigerator where it is vibrationally attenuated with 110-130 dB at these frequencies. In this work, we discuss future improvements on the setup which may enable quantum ground state cooling on a magnetically levitated particle, that has previously been shown to be a gravitational sensor.