We introduce a method to suspend an optical micromirror, with a total mass of \SI{30}{\micro\gram}, using superconducting magnetic levitation. The micromirror is formed on a silicon membrane, coated with a high-reflectivity dielectric stack and attached to superconducting microspheres. The object is stably levitated inside a magnetic quadrupole field at cryogenic temperatures. Magnetic feedback on the transverse motion is used to stabilize the position of the levitator within the trapping field, allowing to measure the axial displacement of the levitator using optical interferometry. The system reaches a sensitivity of order \SI{100}{\pico\metre/\sqrt{\hertz}} near the axial trap frequency of \SI{167}{Hz}. This approach enables free-standing mirrors with minimal dissipation and tunable oscillation frequencies, offering a platform for precision sensing and quantum cavity optomechanics in the microgram regime.
AI Summary
The paper investigates whether superconducting magnetic levitation can suspend a high-reflectivity micromirror without mechanical clamping while permitting optical displacement readout. A microfabricated concave silicon mirror with a localized dielectric Bragg coating is attached to four press-fitted PbSn superconducting spheres, giving a total mass of approximately $30\,\mu\mathrm{g}$. The assembly is levitated in a superconducting anti-Helmholtz trap at $3.2\,\mathrm{K}$. Camera-based magnetic feedback followed by feedback using position-dependent reflected intensity reduces transverse oscillations from tens of micrometres to below approximately $1\,\mu\mathrm{m}$, enabling homodyne detection of axial motion. At an axial resonance near $167\,\mathrm{Hz}$, the displacement noise floor is approximately $100\,\mathrm{pm}/\sqrt{\mathrm{Hz}}$, falling to $16\,\mathrm{pm}/\sqrt{\mathrm{Hz}}$ at $1\,\mathrm{kHz}$ with approximately $10\,\mathrm{pW}$ detected power. Frequency stability and measurement resolution establish only a lower bound $Q\geq1500$. Separately, a room-temperature cavity measurement using an unreleased mirror establishes finesse exceeding $10^4$; a high-finesse cavity containing the levitated mirror is not demonstrated. Levitation lasts up to approximately $600\,\mathrm{s}$ without probe illumination, while several nanowatts of probe power permit tens of seconds. Lifetime measurements versus aperture size, trap current and probe power support heating-induced superconducting quenching as the limiting mechanism. Heating also produces an axial-frequency drift of approximately $-42.3\,\mathrm{mHz/s}$. Readout remains limited by technical interferometer noise, laser-frequency noise and cryocooler vibrations. Residual transverse motion can move illumination onto uncoated silicon, accelerating heating. Ground-state cooling and cavity-enhanced readout remain proposed extensions.
Error found: The paper equates several nanowatts at 637 nm with approximately 3×10^11 photons/s, although that flux corresponds to approximately 94 nW. The stated 10 pW detected power implies an ideal single-sided homodyne displacement shot-noise floor of approximately 6.3 pm/√Hz at 637 nm, rather than the quoted 2.5 pm/√Hz, with no explanation of the discrepancy.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.