Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.02828

Effective Sub-Quantum Readout for Non-Monochromatic Axion Signals in High-$Q$ Haloscopes

Junu Jeong, Max Silva-Feaver

hep-exquant-phSubmitted Sep 2, 2026• Announced Sep 3, 2026• 0 citations
arXivHTMLPDF

Abstract

The search for wave-like dark matter using microwave cavity haloscopes is constrained by the Standard Quantum Limit, which dictates that phase-preserving linear amplification results in a minimum of one quantum of total system noise for a narrow-band signal. We demonstrate that this limit is effectively halved for a non-monochromatic axion signal coupled to a high-$Q$ cavity. By operating a Josephson Parametric Amplifier such that the cavity resonance is centered exactly at the half-pump frequency, the axion signal symmetrically populates both the signal and idler bands. Through quadrature analysis of the homodyne readout, we show that the incoherent sum of these mirrored spectral components doubles the measured signal power while the vacuum noise remains constant. This operation yields an effective noise limit of 0.5 quanta per frequency bin, translating to an overall effective limit of $1/\sqrt{2}$ quanta after optimal matched filtering.

Comments
4 pages

Related papers

Improving Amplification Bandwidth by Combining Josephson Parametric Amplifiers for Active Axion Search Experiments at IBS/CAPP

Sergey V. Uchaikin, Jinmyeong Kim, Boris I. Ivanov +8 more

Abstract The Center for Axion and Precision Physics Research at the Institute for Basic Science in Republic of Korea is home to multiple active axion search experiments using cavity haloscopes that operate within the frequency range of 1–6 GHz. The haloscopes convert axions to photons, resulting in an output power of about 10 $${^{-24}}$$ - 24 –10 $${^{-22}}$$ - 22 W. To detect such a small signal amidst noise, quantum-limited noise amplifiers and ultra-low-temperature environment (a few tenths of mK) are required for all critical readout components to minimize noise from all active and passive lossy components. Our primary objective is to achieve the highest possible scanning-frequency speed, which includes the time for maintenance and system calibration. This paper presents the development and operation of low-noise amplifiers for haloscope experiments targeting different frequency ranges and provides design, operational, and performance details of the amplifiers.

Journal of Low Temperature Physics•Jul 1, 2024•5 citations

Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter

C. Braggio, Léo Balembois, R. Di Vora +10 more

We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz.

arXiv:2403.02321•Physical Review X•Apr 28, 2025•54 citations

Josephson Parametric Amplifier in Axion Experiments

Jinmyeong Kim, Boris I. Ivanov, Çağlar Kutlu +9 more

The axion is a hypothetical particle, a promising candidate for dark matter, and a solution to the strong CP problem.Axion haloscope search experiments deal with a signal power comparable to noise uncertainty at millikelvin temperature.We use a flux-driven Josephson parametric amplifier (JPA) with the aim of approaching a noise level near the theoretically allowed limit of half quanta.In our measurements to characterize the JPA we have found the added noise to the system with a JPA as the first-stage amplifier to be lower than 110 mK at the frequencies from 0.938 GHz to 0.963 GHz.

arXiv:2304.04378•International Conference on Low Temperature Physics (LT)•May 22, 2023•4 citations

Characterization of a flux-driven Josephson parametric amplifier with near quantum-limited added noise for axion search experiments

Çağlar Kutlu, Arjan F. van Loo, Sergey V. Uchaikin +7 more

Abstract The experimental non-observation of charge-parity (CP) symmetry violation in quantum chromodynamics is commonly referred to as the strong CP problem. The axion, a hypothetical elementary pseudoscalar, is expected to solve the strong CP problem and is also a promising candidate for dark matter. The most sensitive axion search experiments operate at millikelvin temperatures and hence rely on instrumentation that carries signals from a system at cryogenic temperatures to room temperature instrumentation. One of the biggest limiting factors affecting the parameter scanning speed of these detectors is the noise added by the components in the signal detection chain. Since the first amplifier in the chain limits the minimum noise, low-noise amplification is of paramount importance. This paper reports on the operation of a flux-driven Josephson parametric amplifier (JPA) operating at around 2.3 GHz with added noise approaching the quantum limit. The JPA was employed as a first stage amplifier in an experimental setting similar to the ones used in haloscope axion detectors. By operating the JPA at a gain of 19 dB and cascading it with two cryogenic amplifiers operating at 4 K, noise temperatures as low as 120 mK were achieved for the whole signal detection chain.

arXiv:2101.08496•Superconductor Science and Technology•Mar 25, 2021•44 citations

Searching for Dark Matter with a Superconducting Qubit

Akash V. Dixit, Srivatsan Chakram, Kevin T. He +4 more

Detection mechanisms for low mass bosonic dark matter candidates, such as the axion or hidden photon, leverage potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal, sub-SQL detection techniques are required. Here we report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum nondemolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to ε≤1.68×10^{-15} in a band around 6.011 GHz (24.86 μeV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1,300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this Letter.

arXiv:2008.12231•Physical Review Letters•Apr 8, 2021•218 citations

Wide-Mass-Scanning-Range Setup and Phase-Resolved Protocol for Axion Dark Matter Detection

A. Cottet, T. Kontos

We propose a paradigm for quantum enhanced axion dark matter search, which does not rely on power measurements. We propose to measure directly the axion amplitude and phase in an interferometric protocol at the quantum limit, using a non-linear cavity. In addition, we introduce gyromagnetic modes as wide mass range transducers for axion signals compatible with standard haloscope designs. We expect this scheme to offer an improvement of at least 4 orders of magnitude in figure of merit and at least 2 orders of magnitude in mass window with respect to standard haloscopes. Owing to its generality, our proposed protocol has the potential to speed up axion search but also the search for dark photons or other cosmological objects, such as galactic masers.

hep-phCross-listedarXiv:2609.32554•Sep 29, 2026
Effective Sub-Quantum Readout for Non-Monochromatic Axion Signals in High-QQQ Haloscopes
The search for wave-like dark matter using microwave cavity haloscopes is constrained by the Standard Quantum Limit, which dictates that phase-preserving linear amplification results in a minimum of one quantum of total system noise for a narrow-band signal. We demonstrate that this limit is effectively halved for a non-monochromatic axion signal coupled to a high-QQQ cavity. By operating a Josephson Parametric Amplifier such that the cavity resonance is centered exactly at the half-pump frequency, the axion signal symmetrically populates both the signal and idler bands. Through quadrature analysis of the homodyne readout, we show that the incoherent sum of these mirrored spectral components doubles the measured signal power while the vacuum noise remains constant. This operation yields an effective noise limit of 0.5 quanta per frequency bin, translating to an overall effective limit of 1/21/\sqrt{2}1/2​ quanta after optimal matched filtering.
Abstract The Center for Axion and Precision Physics Research at the Institute for Basic Science in Republic of Korea is home to multiple active axion search experiments using cavity haloscopes that operate within the frequency range of 1–6 GHz. The haloscopes convert axions to photons, resulting in an output power of about 10 −24{^{-24}}−24 - 24 –10 −22{^{-22}}−22 - 22 W. To detect such a small signal amidst noise, quantum-limited noise amplifiers and ultra-low-temperature environment (a few tenths of mK) are required for all critical readout components to minimize noise from all active and passive lossy components. Our primary objective is to achieve the highest possible scanning-frequency speed, which includes the time for maintenance and system calibration. This paper presents the development and operation of low-noise amplifiers for haloscope experiments targeting different frequency ranges and provides design, operational, and performance details of the amplifiers.
We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz.
The axion is a hypothetical particle, a promising candidate for dark matter, and a solution to the strong CP problem.Axion haloscope search experiments deal with a signal power comparable to noise uncertainty at millikelvin temperature.We use a flux-driven Josephson parametric amplifier (JPA) with the aim of approaching a noise level near the theoretically allowed limit of half quanta.In our measurements to characterize the JPA we have found the added noise to the system with a JPA as the first-stage amplifier to be lower than 110 mK at the frequencies from 0.938 GHz to 0.963 GHz.
Abstract The experimental non-observation of charge-parity (CP) symmetry violation in quantum chromodynamics is commonly referred to as the strong CP problem. The axion, a hypothetical elementary pseudoscalar, is expected to solve the strong CP problem and is also a promising candidate for dark matter. The most sensitive axion search experiments operate at millikelvin temperatures and hence rely on instrumentation that carries signals from a system at cryogenic temperatures to room temperature instrumentation. One of the biggest limiting factors affecting the parameter scanning speed of these detectors is the noise added by the components in the signal detection chain. Since the first amplifier in the chain limits the minimum noise, low-noise amplification is of paramount importance. This paper reports on the operation of a flux-driven Josephson parametric amplifier (JPA) operating at around 2.3 GHz with added noise approaching the quantum limit. The JPA was employed as a first stage amplifier in an experimental setting similar to the ones used in haloscope axion detectors. By operating the JPA at a gain of 19 dB and cascading it with two cryogenic amplifiers operating at 4 K, noise temperatures as low as 120 mK were achieved for the whole signal detection chain.
Detection mechanisms for low mass bosonic dark matter candidates, such as the axion or hidden photon, leverage potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal, sub-SQL detection techniques are required. Here we report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum nondemolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to ε≤1.68×10^{-15} in a band around 6.011 GHz (24.86 μeV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1,300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this Letter.
We propose a paradigm for quantum enhanced axion dark matter search, which does not rely on power measurements. We propose to measure directly the axion amplitude and phase in an interferometric protocol at the quantum limit, using a non-linear cavity. In addition, we introduce gyromagnetic modes as wide mass range transducers for axion signals compatible with standard haloscope designs. We expect this scheme to offer an improvement of at least 4 orders of magnitude in figure of merit and at least 2 orders of magnitude in mass window with respect to standard haloscopes. Owing to its generality, our proposed protocol has the potential to speed up axion search but also the search for dark photons or other cosmological objects, such as galactic masers.