Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2607.19319

Dark matter searches with a 13 meV threshold superconducting sensor array

Christopher Albert, Lanqing Yuan, Jacob Harris, Ritoban Basu Thakur, Andrew Bear, Karl K. Berggren, Christopher Cappiello, Christopher Curwen, Peter Day, Byeong H. Eom, Arjun Ghosh, William Ho, Nikita Klimovich, Henry G. LeDuc, Karthik Ramanathan, Alejandro Simon

hep-exastro-ph.IMquant-phSubmitted Jul 21, 2026• Announced Jul 22, 2026• Revised Jul 23, 2026 (v2)
v1 · Jul 21, 2026v2 · Jul 23, 2026
arXivHTMLPDF

Abstract

Many well-motivated dark matter models predict meV-scale energy deposits in interactions with terrestrial experiments, but this regime is challenging to probe due to a lack of mature single-quantum detectors. Here we report results from QUALIPHIDE (QUAntum LImited PHotons In the Dark Experiment), a cryogenic dark matter search using a $41$-pixel array of energy-resolving microwave kinetic inductance detectors with a $13$ meV threshold, simultaneously used to look for both conversion photons from THz wavelength hidden photon dark matter and phonons from particle-like light dark matter interactions. The experimental design, with on- and off-focus pixels for the hidden photon search, allows for a data-driven background model, giving the experiment discovery potential. A blind analysis of $22$ hours of data shows no significant excess, setting the strongest constraints on the hidden photon kinetic mixing parameter $χ$ over the mass range of $13$-$90$ meV/$c^2$, reaching $1.5\times10^{-12}$ at $50$ meV/$c^2$. These data also yield among the first terrestrial limits on dark matter scattering off nuclei and electrons, down to $5$ MeV/$c^2$ and $20$ keV/$c^2$, respectively. The low threshold also enables future study of the low-energy excess limiting cryogenic detectors and, as we project, will allow for a terahertz-scale QCD axion search with a magnetic field.

Comments
The authors identified a numerical problem in efficiency estimation, which may potentially impact the conclusion of this paper. The manuscript is being revised

Related papers

Searching for Dark Matter with a Superconducting Qubit

Akash V. Dixit, Srivatsan Chakram, Kevin T. He +4 more

Detection mechanisms for low mass bosonic dark matter candidates, such as the axion or hidden photon, leverage potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal, sub-SQL detection techniques are required. Here we report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum nondemolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to ε≤1.68×10^{-15} in a band around 6.011 GHz (24.86 μeV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1,300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this Letter.

arXiv:2008.12231•Physical Review Letters•Apr 8, 2021•218 citations

Dark Matter Detection through Rydberg Atom Transducer

J. F. Chen, Haokun Fu, Christina Gao +5 more

Ultralight bosonic dark matter with masses in the meV range, corresponding to terahertz (THz) Compton frequencies, remains largely unexplored due to the difficulty of achieving both efficient signal conversion and single-photon-sensitive detection at THz frequencies. We propose a hybrid detection architecture that integrates a dielectric haloscope, Rydberg-atom transducer, and superconducting nanowire single-photon detection within a unified cryogenic platform operating at $\lesssim 1\,\text{K}$. The dielectric haloscope converts dark matter into THz photons via phase-matched resonant enhancement, achieving form factors $C \sim 0.4$ and loaded quality factors $Q_L \sim 10^4$. A cold $^{87}$Rb ensemble then coherently up-converts the THz signal to the optical domain through six-wave mixing among Rydberg states. The intrinsic directionality and narrow bandwidth ($Δν_{\mathrm{atomic}} \sim 1\,\text{MHz}$) of this process provide extra suppression of isotropic thermal backgrounds. With 10 days of integration at $0.3\,\text{K}$, we project sensitivity to the axion-photon coupling $g_{aγγ} \sim 10^{-13}\,\mathrm{GeV}^{-1}$ at $m_a \sim 0.4\,\text{meV}$, reaching the QCD axion band and opening the THz window for searches of both axion and dark photon dark matter.

hep-phCross-listedarXiv:2603.23337•Mar 25, 2026

Benchmarking Dark Matter Search using a Parity-Check Protocol with Machine-Learning Optimized Pulses

Yu-Han Chang, Ilya Moskalenko, Marko Kuzmanović +7 more

We report on an improved microwave detection protocol for dark matter candidates such as the axion and the dark photon. We employ a superconducting transmon qubit dispersively coupled to a double-cavity system, enabling quantum non-demolition measurements of the photon occupation in a relatively short-lived storage cavity. To reduce the experimental cycle time and enhance sensitivity for axion and dark-photon searches, we operate this detector in a regime of increased qubit-cavity coupling, resulting in Stark shifts of 4.6 MHz. In this regime, conventional control pulses suffer from strong frequency-detuning sensitivity and photon-number-dependent errors. We address this limitation by implementing frequency-detuning-robust $π/2$ pulses (obtained by machine-learning optimization) that preserve high-fidelity qubit control over a bandwidth of approximately 20 MHz. We experimentally validate this protocol and demonstrate single-photon detection performance comparable to previous implementations, despite significantly reduced qubit coherence times and storage-cavity lifetimes. Using parity-based measurement sequences combined with a Hidden Markov Model (HMM) analysis, we achieve background rates on the order of $\mathcal{O}(20)$ Hz. In the absence of a magnetic field, we derive exclusion limits on the dark photon model for dark matter, reaching a sensitivity to the kinetic mixing angle of $ε_{95\%} \sim 1\times10^{-14}$ at 5.051 GHz. These results establish machine-learning robust control as a key enabler for faster, more scalable microwave quantum sensors for dark-matter searches.

quant-pharXiv:2606.25795•Physical review. D/Physical review. D.•Jun 25, 2026•0 citations

Searching for Dark Matter with Superconducting Qubits

Akash V. Dixit

Dark matter is an enduring mystery in our quest to understand the fundamental constituents of our universe. Low mass bosons, such the axion or hidden photon, are compelling dark matter candidates. We leverage their potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon, to devise a method of detecting these candidates. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal and enable future searches, sub-SQL detection techniques are required. In this thesis, I report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum non-demolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to less than 1.68 X 10^{-15} in a band around 6.011 GHz (24.86 micro-eV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this work.

•Jun 1, 2021•0 citations

Searching for Axion Dark Matter via Superconductor-Spin Hybrid Magnetometers

Runqi Kang, Jian Zhang, Liangliang Rong +1 more

Axions are a compelling dark matter candidate suggested by theories beyond the Standard Model. The predicted axion-electron coupling and the resulting pseudomagnetic field allow for laboratory axion searches. Here we report an experimental axion search via a superconductor-spin hybrid magnetometer. A state-of-the-art broadband magnetometer with a sensitivity of sub-100 aT/Hz$^{1/2}$ at tens of kHz has been realized by coupling a ferrite spin sensor to a readout system based on a superconducting quantum interference device. The most stringent terrestrial constraints on the axion-electron coupling have been established in the frequency range 5$\sim$60 kHz. In the future, an improvement on the constraints of more than 4 orders of magnitude is foreseeable through arrays of superconductor-spin hybrid magnetometers with optimized designs. This work demonstrates the potential of superconductor-spin hybrid magnetometers in high-precision magnetic field sensing and the study of fundamental physics.

physics.ins-detCross-listedarXiv:2610.27764•Oct 21, 2026

Searching for axions with quantum interferometry

Tanmay Kumar Poddar, Michael Spannowsky

Quantum phase measurements offer a complementary route to axion searches. We show that axion-photon interactions can imprint both Aharonov-Bohm (AB) and Berry phases in experimentally motivated quantum setups. For a coherently oscillating axion dark matter background, the induced effective current generates a time dependent magnetic flux in an rf-SQUID, leading to a measurable voltage signal through the Josephson phase. For representative benchmarks, this AB phase search reaches the minimum axion-photon coupling $g_{aγγ}^{\mathrm{min}}\sim 7.8\times10^{-14}~\mathrm{GeV}^{-1}$ at axion mass $m_a\sim 10^{-10}~\mathrm{eV}$, with projected sensitivity that can improve on existing limits in that parameter space by roughly one to two orders of magnitude. We also identify a geometric phase observable in a Mach-Zehnder interferometer with an adiabatically rotating magnetic field, providing a proof-of-principle phase-based probe of meV-scale axions even when they do not constitute the dark matter, although sensitivity on the coupling remains weaker than current bounds with conservative tabletop benchmarks. Extending the analysis to a three level photon-axion quasiparticle (AQP)-axion system, with the AQP realized in a topological magnetic insulator, we find a potentially measurable THz Berry phase dominated by the AQP sector, furnishing a nontrivial validation of the formalism in a richer coupled system. These setups establish quantum phase observables as a useful new framework for axion searches, with immediate phenomenological promise in superconducting circuits and longer term potential in quantum enhanced interferometry.

hep-phCross-listedarXiv:2604.13181•Apr 16, 2026
Many well-motivated dark matter models predict meV-scale energy deposits in interactions with terrestrial experiments, but this regime is challenging to probe due to a lack of mature single-quantum detectors. Here we report results from QUALIPHIDE (QUAntum LImited PHotons In the Dark Experiment), a cryogenic dark matter search using a 414141-pixel array of energy-resolving microwave kinetic inductance detectors with a 131313 meV threshold, simultaneously used to look for both conversion photons from THz wavelength hidden photon dark matter and phonons from particle-like light dark matter interactions. The experimental design, with on- and off-focus pixels for the hidden photon search, allows for a data-driven background model, giving the experiment discovery potential. A blind analysis of 222222 hours of data shows no significant excess, setting the strongest constraints on the hidden photon kinetic mixing parameter χχχ over the mass range of 131313-909090 meV/c2c^2c2, reaching 1.5×10−121.5\times10^{-12}1.5×10−12 at 505050 meV/c2c^2c2. These data also yield among the first terrestrial limits on dark matter scattering off nuclei and electrons, down to 555 MeV/c2c^2c2 and 202020 keV/c2c^2c2, respectively. The low threshold also enables future study of the low-energy excess limiting cryogenic detectors and, as we project, will allow for a terahertz-scale QCD axion search with a magnetic field.
Detection mechanisms for low mass bosonic dark matter candidates, such as the axion or hidden photon, leverage potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal, sub-SQL detection techniques are required. Here we report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum nondemolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to ε≤1.68×10^{-15} in a band around 6.011 GHz (24.86 μeV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1,300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this Letter.
Ultralight bosonic dark matter with masses in the meV range, corresponding to terahertz (THz) Compton frequencies, remains largely unexplored due to the difficulty of achieving both efficient signal conversion and single-photon-sensitive detection at THz frequencies. We propose a hybrid detection architecture that integrates a dielectric haloscope, Rydberg-atom transducer, and superconducting nanowire single-photon detection within a unified cryogenic platform operating at ≲1 K\lesssim 1\,\text{K}≲1K. The dielectric haloscope converts dark matter into THz photons via phase-matched resonant enhancement, achieving form factors C∼0.4C \sim 0.4C∼0.4 and loaded quality factors QL∼104Q_L \sim 10^4QL​∼104. A cold 87^{87}87Rb ensemble then coherently up-converts the THz signal to the optical domain through six-wave mixing among Rydberg states. The intrinsic directionality and narrow bandwidth (Δνatomic∼1 MHzΔν_{\mathrm{atomic}} \sim 1\,\text{MHz}Δνatomic​∼1MHz) of this process provide extra suppression of isotropic thermal backgrounds. With 10 days of integration at 0.3 K0.3\,\text{K}0.3K, we project sensitivity to the axion-photon coupling gaγγ∼10−13 GeV−1g_{aγγ} \sim 10^{-13}\,\mathrm{GeV}^{-1}gaγγ​∼10−13GeV−1 at ma∼0.4 meVm_a \sim 0.4\,\text{meV}ma​∼0.4meV, reaching the QCD axion band and opening the THz window for searches of both axion and dark photon dark matter.
We report on an improved microwave detection protocol for dark matter candidates such as the axion and the dark photon. We employ a superconducting transmon qubit dispersively coupled to a double-cavity system, enabling quantum non-demolition measurements of the photon occupation in a relatively short-lived storage cavity. To reduce the experimental cycle time and enhance sensitivity for axion and dark-photon searches, we operate this detector in a regime of increased qubit-cavity coupling, resulting in Stark shifts of 4.6 MHz. In this regime, conventional control pulses suffer from strong frequency-detuning sensitivity and photon-number-dependent errors. We address this limitation by implementing frequency-detuning-robust π/2π/2π/2 pulses (obtained by machine-learning optimization) that preserve high-fidelity qubit control over a bandwidth of approximately 20 MHz. We experimentally validate this protocol and demonstrate single-photon detection performance comparable to previous implementations, despite significantly reduced qubit coherence times and storage-cavity lifetimes. Using parity-based measurement sequences combined with a Hidden Markov Model (HMM) analysis, we achieve background rates on the order of O(20)\mathcal{O}(20)O(20) Hz. In the absence of a magnetic field, we derive exclusion limits on the dark photon model for dark matter, reaching a sensitivity to the kinetic mixing angle of ε95%∼1×10−14ε_{95\%} \sim 1\times10^{-14}ε95%​∼1×10−14 at 5.051 GHz. These results establish machine-learning robust control as a key enabler for faster, more scalable microwave quantum sensors for dark-matter searches.
Dark matter is an enduring mystery in our quest to understand the fundamental constituents of our universe. Low mass bosons, such the axion or hidden photon, are compelling dark matter candidates. We leverage their potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon, to devise a method of detecting these candidates. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal and enable future searches, sub-SQL detection techniques are required. In this thesis, I report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum non-demolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to less than 1.68 X 10^{-15} in a band around 6.011 GHz (24.86 micro-eV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this work.
Axions are a compelling dark matter candidate suggested by theories beyond the Standard Model. The predicted axion-electron coupling and the resulting pseudomagnetic field allow for laboratory axion searches. Here we report an experimental axion search via a superconductor-spin hybrid magnetometer. A state-of-the-art broadband magnetometer with a sensitivity of sub-100 aT/Hz1/2^{1/2}1/2 at tens of kHz has been realized by coupling a ferrite spin sensor to a readout system based on a superconducting quantum interference device. The most stringent terrestrial constraints on the axion-electron coupling have been established in the frequency range 5$\sim$60 kHz. In the future, an improvement on the constraints of more than 4 orders of magnitude is foreseeable through arrays of superconductor-spin hybrid magnetometers with optimized designs. This work demonstrates the potential of superconductor-spin hybrid magnetometers in high-precision magnetic field sensing and the study of fundamental physics.
Quantum phase measurements offer a complementary route to axion searches. We show that axion-photon interactions can imprint both Aharonov-Bohm (AB) and Berry phases in experimentally motivated quantum setups. For a coherently oscillating axion dark matter background, the induced effective current generates a time dependent magnetic flux in an rf-SQUID, leading to a measurable voltage signal through the Josephson phase. For representative benchmarks, this AB phase search reaches the minimum axion-photon coupling gaγγmin∼7.8×10−14 GeV−1g_{aγγ}^{\mathrm{min}}\sim 7.8\times10^{-14}~\mathrm{GeV}^{-1}gaγγmin​∼7.8×10−14 GeV−1 at axion mass ma∼10−10 eVm_a\sim 10^{-10}~\mathrm{eV}ma​∼10−10 eV, with projected sensitivity that can improve on existing limits in that parameter space by roughly one to two orders of magnitude. We also identify a geometric phase observable in a Mach-Zehnder interferometer with an adiabatically rotating magnetic field, providing a proof-of-principle phase-based probe of meV-scale axions even when they do not constitute the dark matter, although sensitivity on the coupling remains weaker than current bounds with conservative tabletop benchmarks. Extending the analysis to a three level photon-axion quasiparticle (AQP)-axion system, with the AQP realized in a topological magnetic insulator, we find a potentially measurable THz Berry phase dominated by the AQP sector, furnishing a nontrivial validation of the formalism in a richer coupled system. These setups establish quantum phase observables as a useful new framework for axion searches, with immediate phenomenological promise in superconducting circuits and longer term potential in quantum enhanced interferometry.