A nanoscale magnetic spectrum analyzer based on qubit dressed states

Jan Hendrik Rueschkamp, Shantam Ravan, Daniel Fernandez, Nazar Delegan, F. Joseph Heremans, D. D. Awschalom, Ronald Lee Walsworth, Nikola Maksimovic, Amir Yacoby

Published Jun 3, 2026• 0 citations
arXivHTMLPDF

Abstract

Magnetic field fluctuations on nanometer length scales manifest in a diverse range of phenomena -- electron and spin dynamics in materials and devices, quantum many-body systems, and molecular chemistry. Measuring these phenomena requires sensors with a challenging combination of broad spectral bandwidth, high sensitivity, and nanoscale spatial resolution. Nitrogen-vacancy (NV) centers, atom-like quantum sensors in diamond, possess the requisite sensitivity and nanoscale sensing volume, but are typically limited in bandwidth by the practical speed of the applied quantum control sequence. Here, we overcome this limitation by exposing the NV qubit to a microwave dressing field during a dynamical decoupling sequence, which both amplifies and frequency-mixes target signals at arbitrary frequencies into the detection band of the dynamical decoupling protocol. We demonstrate this approach by using NV centers to detect both coherent and noisy nanoscale spin wave dynamics in a magnetic yttrium-iron-garnet (YIG) thin film over a broad frequency range. Our technique generalizes to other qubit platforms, providing a versatile framework for nanoscale spectroscopy across diverse physical and chemical systems.

DOI
10.48550/arxiv.2606.05426

Related papers

High-resolution, Wide-frequency-range Magnetic Spectroscopy with Solid-state Spin Ensembles

Ronald Lee Walsworth, Zechuan Yin, Justin J. Welter +2 more

Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.

•Jan 24, 2025•0 citations

High-resolution and wide-frequency-range magnetic spectroscopy with solid-state spin ensembles

Zechuan Yin, Justin J. Welter, Connor Hart +2 more

Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals ( ≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error < 1 ∘ . Compared to state-of-the-art NV-diamond techniques for high-resolution magnetic spectroscopy, the QFM-CASR protocol extends the signal frequency range by more than an order of magnitude, enabling applications in radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.

npj Quantum Information•Dec 3, 2025•2 citations

Extending radiowave frequency detection range with dressed states of solid-state spin ensembles

Jens C. Hermann, Roberto Rizzato, Fleming Bruckmaier +3 more

Quantum sensors using solid-state spin defects excel in the detection of radiofrequency (RF) fields, serving various applications in communication, ranging, and sensing. For this purpose, pulsed dynamical decoupling (PDD) protocols are typically applied, which enhance sensitivity to RF signals. However, these methods are limited to frequencies of a few megahertz, which poses a challenge for sensing higher frequencies. We introduce an alternative approach based on a continuous dynamical decoupling (CDD) scheme involving dressed states of nitrogen vacancy (NV) ensemble spins driven within a microwave resonator. We compare the CDD methods to established PDD protocols and demonstrate the detection of RF signals up to ~85 MHz, about ten times the current limit imposed by the PDD approach under identical conditions. Implementing the CDD method in a heterodyne/synchronized protocol combines the high-frequency detection with high spectral resolution. This advancement extends to various domains requiring detection in the high frequency (HF) and very high frequency (VHF) ranges of the RF spectrum, including spin sensor-based magnetic resonance spectroscopy at high magnetic fields.

arXiv:2407.14483•npj Quantum Information•Oct 26, 2024•17 citations

Dynamical decoupling methods in nanoscale NMR

Carlos Munuera-Javaloy, R. Puebla, J. Casanova

Nuclear magnetic resonance (NMR) schemes can be applied to micron-, and nanometer-sized samples by the aid of quantum sensors such as nitrogen vacancy (NV) color centers in diamond. These minute devices allow for magnetometry of nuclear spin ensembles with high spatial and frequency resolution at ambient conditions, thus having a clear impact in different areas such as chemistry, biology, medicine, and material sciences. In practice, NV quantum sensors are driven by microwave (MW) control fields with a twofold objective: On the one hand, MW fields bridge the energy gap between NV and nearby nuclei which enables a coherent and selective coupling among them while, on the other hand, MW fields remove environmental noise on the NV leading to enhanced interrogation time. In this work we review distinct MW radiation patterns, or dynamical decoupling techniques, for nanoscale NMR applications.

arXiv:2104.10617•Europhysics Letters (EPL)•May 1, 2021•11 citations

Spectral analysis of amplitude-modulated microwave signals with nitrogen-vacancy centers in diamond

Yang Zhitao, Feifei Zhou, Jianghang Yu +4 more

Microwave (MW) magnetometry utilizing nitrogen-vacancy (NV) centers in diamond offers a broad, tunable detection bandwidth enabled by the magnetic-field-dependent electron spin resonances (ESR) of the NV centers. In this work, we present and experimentally demonstrate two NV-based protocols for spectral analysis of amplitude-modulated (MW) signals. The first protocol employs the NV center as a bandpass filter and reconstructs frequency-domain information of MW signals by sweeping the MW carrier frequency. The second protocol achieves optical imaging of the MW spectrum using an NV-based quantum spectrum analyzer, wherein a magnetic field gradient spatially maps the ESR frequencies of the NV centers, enabling parallel detection of multiple spectral components over a wide instantaneous bandwidth. Both protocols show results that agree well with reference measurements from a classical spectrum analyzer. Our approaches extend the application of spin-based quantum sensors to the field of modern communications and can be adapted for other spin-based quantum sensors.

Review of Scientific Instruments•Feb 1, 2026•1 citation

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Feb 8, 2021•1 citation
Magnetic field fluctuations on nanometer length scales manifest in a diverse range of phenomena -- electron and spin dynamics in materials and devices, quantum many-body systems, and molecular chemistry. Measuring these phenomena requires sensors with a challenging combination of broad spectral bandwidth, high sensitivity, and nanoscale spatial resolution. Nitrogen-vacancy (NV) centers, atom-like quantum sensors in diamond, possess the requisite sensitivity and nanoscale sensing volume, but are typically limited in bandwidth by the practical speed of the applied quantum control sequence. Here, we overcome this limitation by exposing the NV qubit to a microwave dressing field during a dynamical decoupling sequence, which both amplifies and frequency-mixes target signals at arbitrary frequencies into the detection band of the dynamical decoupling protocol. We demonstrate this approach by using NV centers to detect both coherent and noisy nanoscale spin wave dynamics in a magnetic yttrium-iron-garnet (YIG) thin film over a broad frequency range. Our technique generalizes to other qubit platforms, providing a versatile framework for nanoscale spectroscopy across diverse physical and chemical systems.
Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.
Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals ( ≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error < 1 ∘ . Compared to state-of-the-art NV-diamond techniques for high-resolution magnetic spectroscopy, the QFM-CASR protocol extends the signal frequency range by more than an order of magnitude, enabling applications in radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.
Quantum sensors using solid-state spin defects excel in the detection of radiofrequency (RF) fields, serving various applications in communication, ranging, and sensing. For this purpose, pulsed dynamical decoupling (PDD) protocols are typically applied, which enhance sensitivity to RF signals. However, these methods are limited to frequencies of a few megahertz, which poses a challenge for sensing higher frequencies. We introduce an alternative approach based on a continuous dynamical decoupling (CDD) scheme involving dressed states of nitrogen vacancy (NV) ensemble spins driven within a microwave resonator. We compare the CDD methods to established PDD protocols and demonstrate the detection of RF signals up to ~85 MHz, about ten times the current limit imposed by the PDD approach under identical conditions. Implementing the CDD method in a heterodyne/synchronized protocol combines the high-frequency detection with high spectral resolution. This advancement extends to various domains requiring detection in the high frequency (HF) and very high frequency (VHF) ranges of the RF spectrum, including spin sensor-based magnetic resonance spectroscopy at high magnetic fields.
Nuclear magnetic resonance (NMR) schemes can be applied to micron-, and nanometer-sized samples by the aid of quantum sensors such as nitrogen vacancy (NV) color centers in diamond. These minute devices allow for magnetometry of nuclear spin ensembles with high spatial and frequency resolution at ambient conditions, thus having a clear impact in different areas such as chemistry, biology, medicine, and material sciences. In practice, NV quantum sensors are driven by microwave (MW) control fields with a twofold objective: On the one hand, MW fields bridge the energy gap between NV and nearby nuclei which enables a coherent and selective coupling among them while, on the other hand, MW fields remove environmental noise on the NV leading to enhanced interrogation time. In this work we review distinct MW radiation patterns, or dynamical decoupling techniques, for nanoscale NMR applications.
Microwave (MW) magnetometry utilizing nitrogen-vacancy (NV) centers in diamond offers a broad, tunable detection bandwidth enabled by the magnetic-field-dependent electron spin resonances (ESR) of the NV centers. In this work, we present and experimentally demonstrate two NV-based protocols for spectral analysis of amplitude-modulated (MW) signals. The first protocol employs the NV center as a bandpass filter and reconstructs frequency-domain information of MW signals by sweeping the MW carrier frequency. The second protocol achieves optical imaging of the MW spectrum using an NV-based quantum spectrum analyzer, wherein a magnetic field gradient spatially maps the ESR frequencies of the NV centers, enabling parallel detection of multiple spectral components over a wide instantaneous bandwidth. Both protocols show results that agree well with reference measurements from a classical spectrum analyzer. Our approaches extend the application of spin-based quantum sensors to the field of modern communications and can be adapted for other spin-based quantum sensors.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.