Abstract Laser speckle, the granular intensity pattern arising from random optical interference, provides a high-dimensional encoding of spectral information that can be exploited for precision metrology. Speckle-based spectrometers have advanced rapidly owing to their compact footprint, mechanical robustness and alignment agnostic nature, yet their spectral resolution has remained limited to the picometre scale. In this work, we break this limit by employing an integrating sphere as a multiply scattering cavity with access to a high range of path lengths to enhance spectral sensitivity. At 780 nm, the resulting device achieves a resolution of 6 fm, corresponding to a resolving power of 1.3 × 10 8 , representing an approximately 80-fold improvement over previous implementations. This ultra-high resolution enables clear discrimination of laser sidebands generated by an electro-optical modulator, with extracted sideband powers agreeing with expected values to within 1%. It further permits a direct speckle-based measurement of the hyperfine structure of the D 2 transition in 85 Rb, with transmission spectra differing by no more than 3.7% from independent wavemeter-referenced measurements. These results establish speckle as a platform for ultra-high precision spectroscopy, radio-frequency spectrometry, and microwave photonics.
Abstract Laser speckle, the granular intensity pattern arising from random optical interference, provides a high-dimensional encoding of spectral information that can be exploited for precision metrology. Speckle-based spectrometers have advanced rapidly owing to their compact footprint, mechanical robustness and alignment agnostic nature, yet their spectral resolution has remained limited to the picometre scale. In this work, we break this limit by employing an integrating sphere as a multiply scattering cavity with access to a high range of path lengths to enhance spectral sensitivity. At 780 nm, the resulting device achieves a resolution of 6 fm, corresponding to a resolving power of 1.3 × 10 8 , representing an approximately 80-fold improvement over previous implementations. This ultra-high resolution enables clear discrimination of laser sidebands generated by an electro-optical modulator, with extracted sideband powers agreeing with expected values to within 1%. It further permits a direct speckle-based measurement of the hyperfine structure of the D 2 transition in 85 Rb, with transmission spectra differing by no more than 3.7% from independent wavemeter-referenced measurements. These results establish speckle as a platform for ultra-high precision spectroscopy, radio-frequency spectrometry, and microwave photonics.
Frequency-modulation (FM) spectroscopy has been performed on the D(2) transitions of rubidium atoms with an AlGaAs diode laser at 780 nm. Doppler-broadened hyperfine-structure transitions of (85)Rb and (87)Rb were resolved with no residual amplitude-modulation-induced background signal by modulating the injection current of the laser diode at a low frequency (20-50 MHz) compared with the Doppler width. To obtain Doppler-free spectra, we combined FM spectroscopy with saturation spectroscopy. The results show that the FM spectroscopy technique is sensitive and should be useful for high-resolution spectroscopy, although the resolution was instrument limited and unusual double peaks were observed.
The quest for miniaturized optical wave-meters and spectrometers has accelerated the design of novel approaches in the field. Particularly, random spectrometers (RS) using the one-to-one correlation between the wavelength and an output random interference pattern emerged as a promising tool combining high spectral resolution and cost-effectiveness. Recently, a chip-scale platform for RS has been demonstrated with a markedly reduced footprint. Yet, despite the evident advantages of such modalities, they are very susceptible to environmental fluctuations and require an external calibration process. To address these challenges, we demonstrate a paradigm shift in the field, enabled by the integration of atomic vapor with a photonic chip and the use of a machine learning classification algorithm. Our approach provides a random wave-meter on chip device with accurate calibration and enhanced robustness against environmental fluctuations. The demonstrated device is expected to pave the way toward fully integrated spectrometers advancing the field of silicon photonics.
Precision atomic and quantum experiments rely on ultra-stable narrow linewidth lasers constructed using table-top ultra-low expansion reference cavities. These experiments often require multiple lasers, operating at different wavelengths, to perform key steps used in state preparation and measurement required in quantum sensing and computing. This is traditionally achieved by disciplining a cavity-stabilized laser to a key atomic transition and then transferring the transition linewidth and stability to other lasers using the same reference cavity in combination with bulk-optic frequency shifting such as acousto-optic modulators. Transitioning such capabilities to a future potentially low-cost photonic-integrated platform will enable a wide range of portable, low power, scalable quantum experiments and applications. Yet, today’s bulk optic approaches pose challenges related to lack of cavity tunability, large free spectral range, and limited photonic integration potential. Here, we address these challenges with demonstration of an agile photonic-integrated 780 nm ultra-high-Q tunable silicon nitride reference cavity that performs multiple critical experimental steps including laser linewidth narrowing, high resolution rubidium spectroscopy, dual-stage stabilization to a rubidium transition, and stability transfer to other lasers. We achieve up to 20 dB of frequency noise reduction at 10 kHz offset, precision spectroscopy over a 250 MHz range, and dual-stage locking to rubidium with an Allan deviation of 8.5 × 10 −12 at 1 s and up to 40 dB frequency noise reduction at 100 Hz frequency offset. We further use the rubidium-disciplined cavity to provide atomic-referenced frequency stability to a second laser and demonstrate multi-wavelength Rydberg electrometry quantum sensing. These results pave the path for integrated, compact, and scalable solutions for quantum sensing, computing, and other atomic and trapped ion applications.
Atomic spectroscopy serves as the basis for quantum precision measurements, where frequency-stabilized lasers are crucial for obtaining accurate atomic spectra.This work introduces a compact laser frequency stabilization system that employs a multifunctional metasurface to adjust the polarization, amplitude, and propagation direction of incident light.By combining with a Rb atomic vapor cell, the system achieves a tunable sub-Doppler spectrum for laser frequency stabilization.The experimental result demonstrates that a laser frequency stability of 3 × 10 -11 is attained from 1 to 200 s at 780 nm with the input power at 20 μW.The devices hold significant potential for compactness, integration, and mass production, making them highly suitable for quantum measurement applications.
Miniaturized spectrometry system is playing an essential role for materials analysis in the development of in-situ or portable sensing platforms across research and industry. However, there unavoidably exists trade-offs between the resolution and operation bandwidth as the device scale down. Here, we report an extreme miniaturized computational photonic molecule (PM) spectrometer utilizing the diverse spectral characteristics and mode-hybridization effect of split eigenfrequencies and super-modes, which effectively eliminates the inherent periodicity and expands operation bandwidth with ultra-high spectral resolution. These results of dynamic control of the frequency, amplitude, and phase of photons in the photonic multi-atomic systems, pave the way to the development of benchtop sensing platforms for applications previously unfeasible due to resolution-bandwidth-footprint limitations, such as in gas sensing or nanoscale biomedical sensing.
Optical clocks with high precision are practical and necessary in atomic physics, geodesy, gravitational wave measurement, etc. Transportability and environmental adaptability are two key indicators to measure the performance of frequency standards. Here, we utilized a highly robust atomic-filter-based Faraday laser as the local oscillator, and achieved two compact Faraday optical frequency standards based on 133Cs6S1/2|F=3⟩→6P3/2|F′=2⟩ and 6S1/2|F=4⟩→6P3/2|F′=5⟩ transitions at 852 nm, leveraging modulation transfer spectroscopy for laser frequency stabilization. The Faraday laser automatically aligns atomic transition spectral lines, due to the use of atomic filters as frequency selective elements. Therefore, the laser wavelength has strong robustness against environmental changes. This setup not only simplifies the operational complexity but also ensures frequency stability. By heterodyne beating between two such compact optical frequency standards, the beatnote achieved a short-term frequency stability of 1.68 × 10−13 at 3 s, remained at the 10−13 level for up to 400 s, and stayed below 2.7 × 10−12 for up to 1600 s, predominantly exhibiting white frequency noise. This underscores the potential of atomic-filter-based Faraday laser in realizing compact and stable frequency standards, mitigating coherent communication error rates, and enhancing the precision of quantum interferometric measurements. Moreover, this approach eliminates the continuous need for external monitoring and adjustments, thereby, offering a practical and robust solution for out of laboratory applications demanding high frequency stability.