Characterization and cancellation of power-line-induced motional-mode frequency noise in a trapped-ion system

Jaehun You, Jiyong Kang, Kyunghye Kim, Wonhyeong Choi, Taehyun Kim

quant-phSubmitted Feb 23, 2026• Announced Feb 24, 2026• 1 citation• Revised Jun 22, 2026 (v2)
v1 · Feb 23, 2026v2 · Jun 22, 2026
arXivHTMLPDF

Abstract

The stability of motional-mode frequency is essential for realizing high-fidelity quantum gates in trapped-ion quantum computing. While broadband Gaussian noise has been extensively studied and mitigated using pulse shaping techniques, the impact of coherent periodic noise has remained largely unexplored. Here we report a systematic investigation of 60-Hz power-line noise and its effect on the secular frequencies of a single ${}^{171}\mathrm{Yb}^{+}$ ion. Using spin-echo Ramsey spectroscopy, we characterize the amplitude and phase of the resulting secular-frequency modulation and validate this characterization via passive phase correction of the Ramsey sequence. Building on this, we implement a cancellation scheme by injecting a compensation tone into the set-point of a PI controller that stabilizes the trap RF drive amplitude. A phasor-fitting procedure optimizes the amplitude and phase of the compensation signal, enabling near-complete suppression of the 60-Hz component. With the cancellation applied, the coherence time of a radial motional mode is extended from approximately 10 ms to 35 ms, consistent with the limit set by motional heating. Our results provide both a clear characterization of periodic motional-mode noise and a practical framework for its suppression in trapped-ion quantum computing platforms.

Journal reference
Sci Rep 16, 18474 (2026)
DOI
10.1038/s41598-026-49820-5
Comments
Main text: 9 pages, 4 figures; Supplementary: 9 pages, 6 figures

Related papers

Compensation of power line-induced magnetic interference in trapped-ion system

Hu Han, Yi Xie, Man-chao Zhang +7 more

Abstract The low-frequency magnetic field noise resulting from the lab[1]oratory power supply is one of the main decoherence sources of trapped-ion qubits. Synchronizing the experimental sequence to the phase of the power line is widely used to mitigate this problem, but it will greatly reduce the ex[1]perimental efficiency. In this paper, we experimentally demonstrate a simple active compensation method to reduce the observed 50 Hz and 150 Hz strong magnetic noise in an ion trap induced by the power line. In our method, a single 40Ca+ ion is used as the noise probe and an reverse compensation sig[1]nal is generated by a programmable arbitrary waveform generator (AWG).After compensation, an 86% reduction of the periodic magnetic field fluc[1]tuation and over 35-fold extension of the coherence time from 70 µs to 2500 µs were observed. This method can also be applied to compensate other spectral components of the magnetic field noise related to the power line, and it is also useful for other atomic systems such as neutral atoms.

Applied Physics B•Oct 4, 2023•5 citations

Quantum Harmonic Oscillator Spectrum Analyzers

Jonas Keller, Pan‐Yu Hou, Katherine C. McCormick +5 more

Characterization and suppression of noise are essential for the control of harmonic oscillators in the quantum regime. We measure the noise spectrum of a quantum harmonic oscillator from low frequency to near the oscillator resonance by sensing its response to amplitude modulated periodic drives with a qubit. Using the motion of a trapped ion, we experimentally demonstrate two different implementations with combined sensitivity to noise from 500 Hz to 600 kHz. We apply our method to measure the intrinsic noise spectrum of an ion trap potential in a previously unaccessed frequency range.

arXiv:2010.10438•Physical Review Letters•Jun 25, 2021•22 citations

Spectroscopic characterization of ion motion for an optical clock based on Coulomb crystals

Keller, Jonas

Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.

•Jan 1, 2015•5 citations

Stabilization of ion-trap secular frequencies for a quantum phase transition study

Jie Zhang, B. T. Chow, P. C. Haljan

An array of ions in a linear radio-frequency (RF) Paul trap is a good candidate for investigating structural phase transitions, such as the linear-to-zigzag (LZ) transition, due to the convenient control provided by modification of the trap confinement strength. In such studies, the trap secular frequencies are a key factor that limits the stability of the critical point (CP). In this paper, we implement secular-frequency stabilization, including active feedback stabilization of the RF voltage near the trap electrodes, and achieve a stability of better than 5~ppm over 200~s for both transverse and axial potentials. To evaluate the combined long-term stability of the trap potential in both directions, we measure the zigzag (ZZ) mode frequency near the CP, where the effect of instability in both trap directions is substantially amplified. The short-term noise within a limited spectral window is also suppressed by this scheme, as inferred from decoherence rates of the ZZ mode measured at different frequencies with Ramsey fringes. We also identify that the limitation of the secular frequency stability is mainly from the imperfect temperature insensitivity of voltage dividers and RF detectors, and as a result improvement of lab temperature stability is of great help for stabilizing the trap frequency.

arXiv:2210.14478•Oct 26, 2022•2 citations

Coherently displaced oscillator quantum states of a single trapped atom

Katherine C McCormick, Jonas Keller, David J Wineland +2 more

Coherently displaced number states of a harmonically bound ion can be coupled to two internal states of the ion by a laser-induced motional sideband interaction. The internal states can subsequently be read out in a projective measurement via state-dependent fluorescence, with near-unit fidelity. This leads to a rich set of line shapes when recording the internal-state excitation probability after a sideband excitation, as a function of the frequency detuning of the displacement drive with respect to the ion's motional frequency. We precisely characterize the coherent displacement based on the resulting line shapes, which exhibit sharp features that are useful for oscillator frequency determination from the single quantum regime up to very large coherent states with average occupation numbers of several hundred. We also introduce a technique based on multiple coherent displacements and free precession for characterizing noise on the trapping potential in the frequency range of 500 Hz–400 kHz. Signals from the ion are directly used to find and eliminate sources of technical noise in this typically unaccessed part of the spectrum.

arXiv:1811.00668•Quantum Science and Technology•Feb 7, 2019•17 citations

A High Motional Frequency Ion Trapping Regime for Quantum Information Science

A. J. Rasmusson

We investigate high frequency motional states of trapped atomic ions. Trapped ions in rf traps are confined by an approximate harmonic potential and exhibit quantum motional states that mediate essential techniques in quantum computing, simulation, networking, and precision measurement. However, motional state decoherence mechanisms, heating and dephasing, are broadly limiting: reduced two-qubit gate fidelities; lower fidelity and lifetime of highly nonclassical bosonic states; long laser cooling times; and large recoil heating rates. These also challenge the scalability of increasingly sophisticated protocols. We propose high motional frequency ion trapping as an operating regime that addresses these challenges and reshapes the design landscape for quantum information experiments and quantum control techniques. We report an experimentally motivated investigation of realizing this high-frequency regime and discuss the consequences for laser cooling, motional state coherence, fidelity and lifetime of nonclassical bosonic states, and scalability of experimental runtimes. We report clear design trajectories for ion traps to reach high motional frequency, a new limiting mechanism for laser cooling at these high frequencies, and more than an order-of-magnitude speedup in experimental duty cycles with larger speed ups possible for quantum error correction protocols. Taken together, high motional frequency ion trapping has broad implications for the future of quantum information experiments.

quant-pharXiv:2604.03435•Apr 7, 2026•1 citation
The stability of motional-mode frequency is essential for realizing high-fidelity quantum gates in trapped-ion quantum computing. While broadband Gaussian noise has been extensively studied and mitigated using pulse shaping techniques, the impact of coherent periodic noise has remained largely unexplored. Here we report a systematic investigation of 60-Hz power-line noise and its effect on the secular frequencies of a single 171Yb+{}^{171}\mathrm{Yb}^{+}171Yb+ ion. Using spin-echo Ramsey spectroscopy, we characterize the amplitude and phase of the resulting secular-frequency modulation and validate this characterization via passive phase correction of the Ramsey sequence. Building on this, we implement a cancellation scheme by injecting a compensation tone into the set-point of a PI controller that stabilizes the trap RF drive amplitude. A phasor-fitting procedure optimizes the amplitude and phase of the compensation signal, enabling near-complete suppression of the 60-Hz component. With the cancellation applied, the coherence time of a radial motional mode is extended from approximately 10 ms to 35 ms, consistent with the limit set by motional heating. Our results provide both a clear characterization of periodic motional-mode noise and a practical framework for its suppression in trapped-ion quantum computing platforms.
Abstract The low-frequency magnetic field noise resulting from the lab[1]oratory power supply is one of the main decoherence sources of trapped-ion qubits. Synchronizing the experimental sequence to the phase of the power line is widely used to mitigate this problem, but it will greatly reduce the ex[1]perimental efficiency. In this paper, we experimentally demonstrate a simple active compensation method to reduce the observed 50 Hz and 150 Hz strong magnetic noise in an ion trap induced by the power line. In our method, a single 40Ca+ ion is used as the noise probe and an reverse compensation sig[1]nal is generated by a programmable arbitrary waveform generator (AWG).After compensation, an 86% reduction of the periodic magnetic field fluc[1]tuation and over 35-fold extension of the coherence time from 70 µs to 2500 µs were observed. This method can also be applied to compensate other spectral components of the magnetic field noise related to the power line, and it is also useful for other atomic systems such as neutral atoms.
Characterization and suppression of noise are essential for the control of harmonic oscillators in the quantum regime. We measure the noise spectrum of a quantum harmonic oscillator from low frequency to near the oscillator resonance by sensing its response to amplitude modulated periodic drives with a qubit. Using the motion of a trapped ion, we experimentally demonstrate two different implementations with combined sensitivity to noise from 500 Hz to 600 kHz. We apply our method to measure the intrinsic noise spectrum of an ion trap potential in a previously unaccessed frequency range.
Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.
An array of ions in a linear radio-frequency (RF) Paul trap is a good candidate for investigating structural phase transitions, such as the linear-to-zigzag (LZ) transition, due to the convenient control provided by modification of the trap confinement strength. In such studies, the trap secular frequencies are a key factor that limits the stability of the critical point (CP). In this paper, we implement secular-frequency stabilization, including active feedback stabilization of the RF voltage near the trap electrodes, and achieve a stability of better than 5~ppm over 200~s for both transverse and axial potentials. To evaluate the combined long-term stability of the trap potential in both directions, we measure the zigzag (ZZ) mode frequency near the CP, where the effect of instability in both trap directions is substantially amplified. The short-term noise within a limited spectral window is also suppressed by this scheme, as inferred from decoherence rates of the ZZ mode measured at different frequencies with Ramsey fringes. We also identify that the limitation of the secular frequency stability is mainly from the imperfect temperature insensitivity of voltage dividers and RF detectors, and as a result improvement of lab temperature stability is of great help for stabilizing the trap frequency.
Coherently displaced number states of a harmonically bound ion can be coupled to two internal states of the ion by a laser-induced motional sideband interaction. The internal states can subsequently be read out in a projective measurement via state-dependent fluorescence, with near-unit fidelity. This leads to a rich set of line shapes when recording the internal-state excitation probability after a sideband excitation, as a function of the frequency detuning of the displacement drive with respect to the ion's motional frequency. We precisely characterize the coherent displacement based on the resulting line shapes, which exhibit sharp features that are useful for oscillator frequency determination from the single quantum regime up to very large coherent states with average occupation numbers of several hundred. We also introduce a technique based on multiple coherent displacements and free precession for characterizing noise on the trapping potential in the frequency range of 500 Hz–400 kHz. Signals from the ion are directly used to find and eliminate sources of technical noise in this typically unaccessed part of the spectrum.
We investigate high frequency motional states of trapped atomic ions. Trapped ions in rf traps are confined by an approximate harmonic potential and exhibit quantum motional states that mediate essential techniques in quantum computing, simulation, networking, and precision measurement. However, motional state decoherence mechanisms, heating and dephasing, are broadly limiting: reduced two-qubit gate fidelities; lower fidelity and lifetime of highly nonclassical bosonic states; long laser cooling times; and large recoil heating rates. These also challenge the scalability of increasingly sophisticated protocols. We propose high motional frequency ion trapping as an operating regime that addresses these challenges and reshapes the design landscape for quantum information experiments and quantum control techniques. We report an experimentally motivated investigation of realizing this high-frequency regime and discuss the consequences for laser cooling, motional state coherence, fidelity and lifetime of nonclassical bosonic states, and scalability of experimental runtimes. We report clear design trajectories for ion traps to reach high motional frequency, a new limiting mechanism for laser cooling at these high frequencies, and more than an order-of-magnitude speedup in experimental duty cycles with larger speed ups possible for quantum error correction protocols. Taken together, high motional frequency ion trapping has broad implications for the future of quantum information experiments.