Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2602.04508 · Quantum Science and Technology

Squeezing-Enhanced Rotational Doppler Metrology

Javier Navarro, Mateo Casariego, Gabriel Molina-Terriza, Íñigo Luis Egusquiza, Mikel Sanz

quant-phSubmitted Feb 4, 2026• Announced Feb 5, 2026• 0 citations
v1 · Feb 4, 2026v2 · Sep 30, 2026
arXivHTMLPDF

Abstract

A rotating surface can induce a frequency shift in incident light by changing its angular momentum, a phenomenon known as the rotational Doppler effect. This effect provides a means to estimate the angular velocity of the rotating surface. In this work, we develop a continuous-variable quantum protocol for estimating the angular velocity of a rotating surface via the rotational Doppler effect. Our approach exploits squeezed and displaced Laguerre-Gaussian modes as quantum resources, which interact with a rotating metallic disc with surface roughness. The frequency shift induced by the rotational Doppler effect is then measured using a homodyne detection scheme. By analyzing the Fisher information, we demonstrate that the proposed squeezing-enhanced protocol achieves Heisenberg scaling in the ideal noiseless regime. Furthermore, we investigate the influence of noise and consider different surface models to assess their impact on the protocol's performance. While Heisenberg scaling is degraded in the presence of noise, we show that optimizing the energy allocation ratio between displacement and squeezing of the probe ensures that the quantum strategy consistently outperforms its classical counterpart.

Journal reference
Quantum Sci. Technol. 11(3), 035017 (2026)
DOI
10.1088/2058-9565/ae77e9

Related papers

Beating noise in frequency estimation with squeezing and memory in continuous-variable systems

Ayan Patra, Manju, Aditi Sen De +1 more

Quantum metrology promises precision beyond classical limits, yet environmental noise typically degrades the quantum resources required for such enhancement. In this work, we investigate frequency estimation in noisy continuous-variable systems, focusing on two complementary strategies to mitigate decoherence: Hamiltonian engineering and the exploitation of non-Markovian dynamics. By embedding squeezing directly into the system Hamiltonian, we show that the quantum Fisher information (QFI) may acquire a tunable higher-order time dependence, leading to enhanced sensitivity in the short-time regime. Moving beyond the Markovian approximation, we employ the quantum Brownian motion model to demonstrate that structured environments with finite memory can induce information backflow, temporarily restoring and even improving estimation precision relative to the unitary limit. We further assess the achievability of these bounds via Gaussian measurements, identifying regimes where homodyne, heterodyne, and optimized general-dyne measurements saturate the QFI, and noting that stronger squeezing widens the gap, potentially requiring non-Gaussian measurement strategies. Our results establish that jointly tailoring system Hamiltonian and environmental memory offers a viable route toward robust quantum-enhanced frequency estimation in open systems.

quant-pharXiv:2605.06263•May 8, 2026•2 citations

Heisenberg-scaling angular displacement estimation with tunable squeezed Bell states

Jiandong Zhang, Zijing Zhang, Longzhu Cen +2 more

Abstract Precise angular displacement estimation provides a route to correct the measurement bases of two parties in quantum teleportation. In this paper, we propose an angular momentum-enhanced estimation protocol deploying tunable squeezed Bell states and parity detection. The Heisenberg-scaling sensitivity and 2 ℓ + 1 -fold super-resolved oscillating fringes with quantum number ℓ are reachable in our protocol. We analyze the effect of tunable factor on sensitivity, and the advantages originating from spin and orbital angular momenta are also discussed.

arXiv:1806.10294•Journal of Optics•Feb 6, 2019•2 citations

Quantum-enhanced Doppler lidar

Maximilian Reichert, Roberto Di Candia, Moe Z. Win +1 more

Abstract We propose a quantum-enhanced lidar system to estimate a target’s radial velocity, which employs squeezed and frequency-entangled signal and idler beams. We compare its performance against a classical protocol using a coherent state with the same pulse duration and energy, showing that quantum resources provide a precision enhancement in the estimation of the velocity of the object. We identify three distinct parameter regimes characterized by the amount of squeezing and frequency entanglement. In two of them, a quantum advantage exceeding the standard quantum limit is achieved assuming no photon losses. Additionally, we show that an optimal measurement to attain these results in the lossless case is frequency-resolved photon counting. Finally, we consider the effect of photon losses for the high-squeezing regime, which leads to a constant factor quantum advantage higher than 3 dB in the variance of the estimator, given a roundtrip lidar-to-target-to-lidar transmissivity larger than 50%.

arXiv:2203.16424•npj Quantum Information•Dec 19, 2022•45 citations

Orbital-angular-momentum-enhanced estimation of sub-Heisenberg-limited angular displacement with two-mode squeezed vacuum and parity detection

Jiandong Zhang, Zijing Zhang, Longzhu Cen +4 more

We report on an orbital-angular-momentum-enhanced scheme for angular displacement estimation based on two-mode squeezed vacuum and parity detection. The sub-Heisenberg-limited sensitivity for angular displacement estimation is obtained in an ideal situation. Several realistic factors are also considered, including photon loss, dark counts, response-time delay, and thermal photon noise. Our results indicate that the effects of realistic factors on the sensitivity can be offset by raising orbital angular momentum quantum number ℓ. This implies that the robustness and the practicability of the system can be improved via raising ℓ without changing mean photon number N.

arXiv:1802.05790•Optics Express•Jun 13, 2018•13 citations

Prefect Protection of Quantum-Enhanced Metrology from Dephasing Noise*

Wei Zhong, Yixiao Huang, Xiaoguang Wang

Abstract One of the main obstacles for quantum-enhanced metrology is that the estimation accuracy enhanced by non-classical states is likely to be obliterated by noises. Here, we consider a scenario of phase estimation suffering from pure dephasing noise which is taken into account after the phase parameter being imprinted, and propose a scheme to effectively protect the quantum enhancement from both correlated and uncorrelated dephasing sources by performing a rotation operation prior to the noise. By invoking the Fisher information approach, we strictly prove that a π / 2 rotation is the ideal one which can completely resist the influence of the phase noise for all real symmetric pure states and the optimal measurement approaching the ultimate sensitivity set by quantum Cramér–Rao bound is presented. Additionally, we numerically study the availability of the scheme with arbitrary angle rotation for different probe states and show that our scheme will still robust for general symmetric pure states even with non-ideal rotation operation.

Communications in Theoretical Physics•Apr 1, 2017•1 citation

Squeezed-light-enhanced heterodyne laser Doppler vibrometer

Mengwei Yu

Laser Doppler Vibrometry (LDV) is a high-precision, non-contact measurement technique that leverages optical interference between a reference beam and a Doppler-shifted measurement beam derived from coherent laser light. By detecting phase variations induced by surface vibrations, LDV has become a widely utilized tool in industrial environments for vibration analysis, structural diagnostics, and quality control. The detection sensitivity of the LDV is fundamentally constrained by the Poissonian statistics of photon arrivals. In heterodyne LDV systems, the enhancement of signal-to-noise ratio (SNR) and measurement resolution under shot-noise-limited conditions typically requires increasing the optical power of the measurement beam. However, this approach becomes infeasible in scenarios with strict constraints on thermal load or optical power. Recent studies have demonstrated that injecting squeezed vacuum states as non-classical light sources can suppress quantum noise while maintaining low optical power, thus surpassing the standard quantum limit. This thesis introduces the principle of the heterodyne LDV combined with squeezed light sources. The first scientific hypothesis proposed herein is that introducing laser light with squeezed quantum uncertainties into industrial heterodyne LDVs enables vibration measurements to exceed the physical resolution limits of traditional LDVs, achieving sub-shot-noise sensitivity. The thesis designed a squeezed-light-enhanced heterodyne LDV, achieving over 3 dB of squeezing within a 40 MHz measurement bandwidth and demonstrating a noise-equivalent displacement resolution reaching 8 fm/√Hz, thereby confirming the first hypothesis. Addressing the limitations imposed by the finite dynamic range of analog-to-digital converters (ADCs) on the SNR of digitally demodulated phase-modulated signals, the thesis proposes a clipping-based synchronous zero-crossing sampling technique and a corresponding second scientific hypothesis: that this sampling scheme enables heterodyne LDV to overcome the digital noise floor defined by the ADC's SNR. Experimental results demonstrate that this sampling and demodulation approach effectively reduces ADC quantization noise, allowing the digital resolution of the demodulated phase-modulated signal to surpass the ADC-imposed SNR limit while preserving the quantum noise-level squeezing, thereby validating the second hypothesis. Compared to previous work, this research constitutes the first experimental verification of squeezed-light-enhanced measurement feasibility in a classical heterodyne LDV operating at a 40 MHz difference frequency, advancing the application of quantum-enhanced precision metrology in industrial vibration testing.

•Dec 15, 2025•0 citations
A rotating surface can induce a frequency shift in incident light by changing its angular momentum, a phenomenon known as the rotational Doppler effect. This effect provides a means to estimate the angular velocity of the rotating surface. In this work, we develop a continuous-variable quantum protocol for estimating the angular velocity of a rotating surface via the rotational Doppler effect. Our approach exploits squeezed and displaced Laguerre-Gaussian modes as quantum resources, which interact with a rotating metallic disc with surface roughness. The frequency shift induced by the rotational Doppler effect is then measured using a homodyne detection scheme. By analyzing the Fisher information, we demonstrate that the proposed squeezing-enhanced protocol achieves Heisenberg scaling in the ideal noiseless regime. Furthermore, we investigate the influence of noise and consider different surface models to assess their impact on the protocol's performance. While Heisenberg scaling is degraded in the presence of noise, we show that optimizing the energy allocation ratio between displacement and squeezing of the probe ensures that the quantum strategy consistently outperforms its classical counterpart.
Quantum metrology promises precision beyond classical limits, yet environmental noise typically degrades the quantum resources required for such enhancement. In this work, we investigate frequency estimation in noisy continuous-variable systems, focusing on two complementary strategies to mitigate decoherence: Hamiltonian engineering and the exploitation of non-Markovian dynamics. By embedding squeezing directly into the system Hamiltonian, we show that the quantum Fisher information (QFI) may acquire a tunable higher-order time dependence, leading to enhanced sensitivity in the short-time regime. Moving beyond the Markovian approximation, we employ the quantum Brownian motion model to demonstrate that structured environments with finite memory can induce information backflow, temporarily restoring and even improving estimation precision relative to the unitary limit. We further assess the achievability of these bounds via Gaussian measurements, identifying regimes where homodyne, heterodyne, and optimized general-dyne measurements saturate the QFI, and noting that stronger squeezing widens the gap, potentially requiring non-Gaussian measurement strategies. Our results establish that jointly tailoring system Hamiltonian and environmental memory offers a viable route toward robust quantum-enhanced frequency estimation in open systems.
Abstract Precise angular displacement estimation provides a route to correct the measurement bases of two parties in quantum teleportation. In this paper, we propose an angular momentum-enhanced estimation protocol deploying tunable squeezed Bell states and parity detection. The Heisenberg-scaling sensitivity and 2 ℓ + 1 -fold super-resolved oscillating fringes with quantum number ℓ are reachable in our protocol. We analyze the effect of tunable factor on sensitivity, and the advantages originating from spin and orbital angular momenta are also discussed.
Abstract We propose a quantum-enhanced lidar system to estimate a target’s radial velocity, which employs squeezed and frequency-entangled signal and idler beams. We compare its performance against a classical protocol using a coherent state with the same pulse duration and energy, showing that quantum resources provide a precision enhancement in the estimation of the velocity of the object. We identify three distinct parameter regimes characterized by the amount of squeezing and frequency entanglement. In two of them, a quantum advantage exceeding the standard quantum limit is achieved assuming no photon losses. Additionally, we show that an optimal measurement to attain these results in the lossless case is frequency-resolved photon counting. Finally, we consider the effect of photon losses for the high-squeezing regime, which leads to a constant factor quantum advantage higher than 3 dB in the variance of the estimator, given a roundtrip lidar-to-target-to-lidar transmissivity larger than 50%.
We report on an orbital-angular-momentum-enhanced scheme for angular displacement estimation based on two-mode squeezed vacuum and parity detection. The sub-Heisenberg-limited sensitivity for angular displacement estimation is obtained in an ideal situation. Several realistic factors are also considered, including photon loss, dark counts, response-time delay, and thermal photon noise. Our results indicate that the effects of realistic factors on the sensitivity can be offset by raising orbital angular momentum quantum number ℓ. This implies that the robustness and the practicability of the system can be improved via raising ℓ without changing mean photon number N.
Abstract One of the main obstacles for quantum-enhanced metrology is that the estimation accuracy enhanced by non-classical states is likely to be obliterated by noises. Here, we consider a scenario of phase estimation suffering from pure dephasing noise which is taken into account after the phase parameter being imprinted, and propose a scheme to effectively protect the quantum enhancement from both correlated and uncorrelated dephasing sources by performing a rotation operation prior to the noise. By invoking the Fisher information approach, we strictly prove that a π / 2 rotation is the ideal one which can completely resist the influence of the phase noise for all real symmetric pure states and the optimal measurement approaching the ultimate sensitivity set by quantum Cramér–Rao bound is presented. Additionally, we numerically study the availability of the scheme with arbitrary angle rotation for different probe states and show that our scheme will still robust for general symmetric pure states even with non-ideal rotation operation.
Laser Doppler Vibrometry (LDV) is a high-precision, non-contact measurement technique that leverages optical interference between a reference beam and a Doppler-shifted measurement beam derived from coherent laser light. By detecting phase variations induced by surface vibrations, LDV has become a widely utilized tool in industrial environments for vibration analysis, structural diagnostics, and quality control. The detection sensitivity of the LDV is fundamentally constrained by the Poissonian statistics of photon arrivals. In heterodyne LDV systems, the enhancement of signal-to-noise ratio (SNR) and measurement resolution under shot-noise-limited conditions typically requires increasing the optical power of the measurement beam. However, this approach becomes infeasible in scenarios with strict constraints on thermal load or optical power. Recent studies have demonstrated that injecting squeezed vacuum states as non-classical light sources can suppress quantum noise while maintaining low optical power, thus surpassing the standard quantum limit. This thesis introduces the principle of the heterodyne LDV combined with squeezed light sources. The first scientific hypothesis proposed herein is that introducing laser light with squeezed quantum uncertainties into industrial heterodyne LDVs enables vibration measurements to exceed the physical resolution limits of traditional LDVs, achieving sub-shot-noise sensitivity. The thesis designed a squeezed-light-enhanced heterodyne LDV, achieving over 3 dB of squeezing within a 40 MHz measurement bandwidth and demonstrating a noise-equivalent displacement resolution reaching 8 fm/√Hz, thereby confirming the first hypothesis. Addressing the limitations imposed by the finite dynamic range of analog-to-digital converters (ADCs) on the SNR of digitally demodulated phase-modulated signals, the thesis proposes a clipping-based synchronous zero-crossing sampling technique and a corresponding second scientific hypothesis: that this sampling scheme enables heterodyne LDV to overcome the digital noise floor defined by the ADC's SNR. Experimental results demonstrate that this sampling and demodulation approach effectively reduces ADC quantization noise, allowing the digital resolution of the demodulated phase-modulated signal to surpass the ADC-imposed SNR limit while preserving the quantum noise-level squeezing, thereby validating the second hypothesis. Compared to previous work, this research constitutes the first experimental verification of squeezed-light-enhanced measurement feasibility in a classical heterodyne LDV operating at a 40 MHz difference frequency, advancing the application of quantum-enhanced precision metrology in industrial vibration testing.