Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2601.10838

Widefield NV Magnetic Field Reconstruction for Probing the Meissner Effect and Critical Current Density under Pressure

Kin On Ho, Cassandra Dailledouze, Martin Schmidt, Loïc Toraille, Marie-Pierre Adam, Jean-François Roch

cond-mat.supr-conquant-phSubmitted Jan 15, 2026• Announced Jan 19, 2026• Revised May 28, 2026 (v2)
v1 · Jan 15, 2026v2 · May 28, 2026
arXivHTMLPDF

Abstract

The spatial distribution of a magnetic field can be determined with micrometer resolution using widefield nitrogen vacancy (NV) center magnetic imaging. Nevertheless, reconstructing the magnetic field from the raw data can be challenging due to the degeneracy of the four possible NV axes and the tremendous amount of data. While a qualitative approach is sufficient for most analyses, a quantitative analysis offers deeper insight into the physical system. Here, we apply NV widefield magnetic imaging to a HgBa$_{2}$Ca$_{2}$Cu$_{3}$O$_{8+δ}$ (Hg-1223) superconducting microcrystal at a pressure of 4 GPa. We fit the results with solutions from the Hamiltonian describing the NV center ground state and take into account the relative intensities of the resonances to determine the local magnetic field magnitude and angle. Thus, we reconstruct the temperature-dependent expulsion of the magnetic field due to the Meissner effect around the superconductor. By comparing the resulting parameters to Brandt's model, which describes the magnetic behavior of a type-II superconductor, we extract the critical current density $j_c$. Overall, this work showcases the first widefield quantitative reconstruction of the Meissner effect under pressure and an optical method to study critical current density. Thus, it provides new insights into the application of NV magnetometry to superconductivity research at high pressures.

Journal reference
Appl. Phys. Lett. 128, 212602 (2026)
DOI
10.1063/5.0323142

Related papers

Development of wide-field magnetic imaging at high pressure and low temperature with diamond quantum sensor

Kenshin URIU, Ryotaro Suda, K. Yamamoto +4 more

Recently, superconductivity under high pressure in hydrogen-rich compounds, such as H3S (Tc=203K at 150 GPa) and LaH10 (Tc=253K at 200 GPa), has attracted extensive research interest due to their high superconducting transition temperatures (Tc). However, magnetic measurements of these materials are significantly challenging in terms of sensitivity and spatial resolution. Consequently, magnetometry under high pressure using nitrogen-vacancy (NV) centers has recently begun to be implemented. The NV center is a promising sensor and is expected to overcome this problem because of its properties, including its size and measurement principles. In this article, we conducted wide-field magnetic imaging using NV centers at low temperatures and pressures of several GPa. The details of the developed measurement system and its application to a cuprate superconductor are demonstrated. By employing our method, the visualization of the Meissner effect in hydride superconductors is anticipated.

High Pressure Research•Apr 1, 2026•0 citations

All-optical and microwave-free detection of Meissner screening using nitrogen-vacancy centers in diamond

D. Paone, D. Pinto, G. Kim +9 more

Microscopic studies on thin film superconductors play an important role for probing non-equilibrium phase transitions and revealing dynamics at the nanoscale. However, magnetic sensors with nanometer scale spatial and picosecond temporal resolution are essential for exploring these. Here, we present an all-optical, microwave-free method that utilizes the negatively charged nitrogen-vacancy (NV) center in diamond as a non-invasive quantum sensor and enables the spatial detection of the Meissner state in a superconducting thin film. We place an NV implanted diamond membrane on a 20nm thick superconducting La2−xSrxCuO4 (LSCO) thin film with Tc of 34K. The strong B-field dependence of the NV photoluminescence allows us to investigate the Meissner screening in LSCO under an externally applied magnetic field of 4.2mT in a non-resonant manner. The magnetic field profile along the LSCO thin film can be reproduced using Brandt’s analytical model, revealing a critical current density jc of 1.4×108A/cm2. Our work can be potentially extended further with a combination of optical pump probe spectroscopy for the local detection of time-resolved dynamical phenomena in nanomagnetic materials.

arXiv:2101.04571•Journal of Applied Physics•Jan 13, 2021•25 citations

Wide-field NV magnetometry under simultaneous high-pressure and high-temperature conditions

Masahiro Ohkuma, Eikichi Kimura, Shumpei Ohyama +7 more

We demonstrate wide-field optically detected magnetic resonance (ODMR) under simultaneous high-pressure and high-temperature conditions using nitrogen-vacancy (NV) centers. Although NV-center magnetometry has been widely used for spatially resolved magnetic-field imaging, its application to extreme environments combining pressure and temperature remains challenging. In this work, we show that ODMR can be observed at 5 GPa and 500 K, demonstrating the feasibility of NV spin readout under such combined extreme conditions. We further perform wide-field ODMR of iron at 7 GPa and 500 K, where the stray magnetic field from the sample is spatially visualized through the pressure cell. These results establish NV-center magnetometry as a promising platform for imaging magnetic phenomena in materials under high-pressure and high-temperature environments.

physics.app-phCross-listedarXiv:2606.25378•Jun 25, 2026

In-Substrate Imaging of Diamond hBN FET Current via Widefield Quantum Diamond Microscopy

Anuj Bathla, Subrat Kumar Pradhan, Ajit Kumar Dash +7 more

We demonstrate widefield magnetic imaging of current flow in hydrogen terminated diamond field effect transistors (FETs) through in-substrate nitrogen vacancy (NV) centers. Hydrogen termination of the diamond surface induces a two dimensional hole gas (2DHG), while an ensemble of near surface NV centers located $ \sim 1~μm$ below the surface enables noninvasive magnetic imaging of current flow with micrometer scale spatial resolution. The FETs were electrically characterized over a range of drain source biases $V_{ds}= 0$ to $-15V$ and gate voltages,$V_{gs}= +3$ to $-9V$ followed by in situ widefield NV magnetometry during device operation. Magnetic field maps and reconstructed current density distributions directly visualize current injection at the source drain contacts and transport beneath the hBN gated channel. Magnetic field maps reveal current density variations in the channel region owing to non-uniformities or defects in the gate dielectric. In addition, we observe a pronounced enhancement of the drain current ($\sim 600-900 μA$) and a shift in the apparent threshold voltage during laser illumination, reflecting photo induced changes in channel electrostatics. By correlating gate dependent magnetic images with simultaneous electrical measurements, we directly link spatial current distributions to FET transfer characteristics, providing new insight into buried interface transport and non-uniform gating effects in the transistor channel. As the methodology is compatible with top gated FETs, it can be used to map channel current distributions with micrometer resolution in emerging channel materials, such as 2D materials and wide bandgap channels, and establish widefield NV magnetometry as a powerful platform for probing charge transport in transistors and Van der Waals dielectric heterostructures.

cond-mat.mes-hallCross-listedarXiv:2601.15355•Jan 22, 2026

Quantitative imaging of Abrikosov vortices by scanning quantum magnetometry

Clemens Schäfermeier, Ankit Sharma, Christopher Kelvin von Grundherr +5 more

Understanding vortex matter in type-II superconductors is central to controlling dissipation and flux pinning in superconducting materials and devices. Here, we use cryogenic scanning nitrogen vacancy magnetometry (NVM) to image Abrikosov vortices in the cuprate superconductors BSCCO-2212 and YBCO under controlled field-cooled conditions. Measurements, which are performed using continuous-wave optically detected magnetic resonance (cw-ODMR) in a closed-cycle cryostat, yield quantitative magnetic-field maps with nanoscale spatial resolution. In BSCCO-2212 at 71 K, we resolve a well-ordered triangular vortex lattice, whose symmetry and spacing are confirmed through 2D Fourier analysis and are consistent with flux quantization. YBCO thin films imaged at 3 K exhibit a more disordered vortex arrangement reflecting stronger pinning, while maintaining quantitative agreement between measured vortex density and the applied magnetic field. These results render our cryogenic scanning NVM a reliable quantitative tool for real-space studies of vortices in high-$T_c$ superconductors, in particular since such a remarkable magnetic resolution has been achieved within relatively short acquisition times of 2 to 4 h.

cond-mat.supr-conCross-listedarXiv:2602.13060•Feb 16, 2026

Widefield Quantum Sensor for Vector Magnetic Field Imaging of Micromagnetic Structures

Orlando D. Cunha, Filipe Camarneiro, João P. Silva +4 more

Many spintronic, magnetic-memory, and neuromorphic devices rely on spatially varying magnetic fields. Quantitatively imaging these fields with full vector information over extended areas remains a major challenge. Existing probes either offer nanoscale resolution at the cost of slow scanning, or widefield imaging with limited vector sensitivity or material constraints. Quantum sensing with nitrogen-vacancy (NV) centers in diamond promises to bridge this gap, but a practical camera-based vector magnetometry implementation on relevant microstructures has not been demonstrated. Here we adapt a commercial widefield microscope to implement a camera-compatible pulsed optically detected magnetic resonance protocol to reconstruct stray-field vectors from microscale devices. By resolving the Zeeman shifts of the four NV orientations, we reconstruct the stray-field vector generated by microfabricated permalloy structures that host multiple stable remanent states. Our implementation achieves a spatial resolution of $\approx 0.52 ~μ\mathrm{m}$ across an $83~μ\mathrm{m} \times 83~μ\mathrm{m}$ field of view and a peak sensitivity of $ (828 \pm 142)~\mathrm{nT\,Hz^{-1}}$, with acquisition times of only a few minutes. These results establish pulsed widefield NV magnetometry on standard microscopes as a practical and scalable tool for routine vector-resolved imaging of complex magnetic devices.

quant-pharXiv:2512.03748•Dec 4, 2025
The spatial distribution of a magnetic field can be determined with micrometer resolution using widefield nitrogen vacancy (NV) center magnetic imaging. Nevertheless, reconstructing the magnetic field from the raw data can be challenging due to the degeneracy of the four possible NV axes and the tremendous amount of data. While a qualitative approach is sufficient for most analyses, a quantitative analysis offers deeper insight into the physical system. Here, we apply NV widefield magnetic imaging to a HgBa2_{2}2​Ca2_{2}2​Cu3_{3}3​O8+δ_{8+δ}8+δ​ (Hg-1223) superconducting microcrystal at a pressure of 4 GPa. We fit the results with solutions from the Hamiltonian describing the NV center ground state and take into account the relative intensities of the resonances to determine the local magnetic field magnitude and angle. Thus, we reconstruct the temperature-dependent expulsion of the magnetic field due to the Meissner effect around the superconductor. By comparing the resulting parameters to Brandt's model, which describes the magnetic behavior of a type-II superconductor, we extract the critical current density jcj_cjc​. Overall, this work showcases the first widefield quantitative reconstruction of the Meissner effect under pressure and an optical method to study critical current density. Thus, it provides new insights into the application of NV magnetometry to superconductivity research at high pressures.
Recently, superconductivity under high pressure in hydrogen-rich compounds, such as H3S (Tc=203K at 150 GPa) and LaH10 (Tc=253K at 200 GPa), has attracted extensive research interest due to their high superconducting transition temperatures (Tc). However, magnetic measurements of these materials are significantly challenging in terms of sensitivity and spatial resolution. Consequently, magnetometry under high pressure using nitrogen-vacancy (NV) centers has recently begun to be implemented. The NV center is a promising sensor and is expected to overcome this problem because of its properties, including its size and measurement principles. In this article, we conducted wide-field magnetic imaging using NV centers at low temperatures and pressures of several GPa. The details of the developed measurement system and its application to a cuprate superconductor are demonstrated. By employing our method, the visualization of the Meissner effect in hydride superconductors is anticipated.
Microscopic studies on thin film superconductors play an important role for probing non-equilibrium phase transitions and revealing dynamics at the nanoscale. However, magnetic sensors with nanometer scale spatial and picosecond temporal resolution are essential for exploring these. Here, we present an all-optical, microwave-free method that utilizes the negatively charged nitrogen-vacancy (NV) center in diamond as a non-invasive quantum sensor and enables the spatial detection of the Meissner state in a superconducting thin film. We place an NV implanted diamond membrane on a 20nm thick superconducting La2−xSrxCuO4 (LSCO) thin film with Tc of 34K. The strong B-field dependence of the NV photoluminescence allows us to investigate the Meissner screening in LSCO under an externally applied magnetic field of 4.2mT in a non-resonant manner. The magnetic field profile along the LSCO thin film can be reproduced using Brandt’s analytical model, revealing a critical current density jc of 1.4×108A/cm2. Our work can be potentially extended further with a combination of optical pump probe spectroscopy for the local detection of time-resolved dynamical phenomena in nanomagnetic materials.
We demonstrate wide-field optically detected magnetic resonance (ODMR) under simultaneous high-pressure and high-temperature conditions using nitrogen-vacancy (NV) centers. Although NV-center magnetometry has been widely used for spatially resolved magnetic-field imaging, its application to extreme environments combining pressure and temperature remains challenging. In this work, we show that ODMR can be observed at 5 GPa and 500 K, demonstrating the feasibility of NV spin readout under such combined extreme conditions. We further perform wide-field ODMR of iron at 7 GPa and 500 K, where the stray magnetic field from the sample is spatially visualized through the pressure cell. These results establish NV-center magnetometry as a promising platform for imaging magnetic phenomena in materials under high-pressure and high-temperature environments.
We demonstrate widefield magnetic imaging of current flow in hydrogen terminated diamond field effect transistors (FETs) through in-substrate nitrogen vacancy (NV) centers. Hydrogen termination of the diamond surface induces a two dimensional hole gas (2DHG), while an ensemble of near surface NV centers located $ \sim 1~μm$ below the surface enables noninvasive magnetic imaging of current flow with micrometer scale spatial resolution. The FETs were electrically characterized over a range of drain source biases Vds=0V_{ds}= 0Vds​=0 to −15V-15V−15V and gate voltages,Vgs=+3V_{gs}= +3Vgs​=+3 to −9V-9V−9V followed by in situ widefield NV magnetometry during device operation. Magnetic field maps and reconstructed current density distributions directly visualize current injection at the source drain contacts and transport beneath the hBN gated channel. Magnetic field maps reveal current density variations in the channel region owing to non-uniformities or defects in the gate dielectric. In addition, we observe a pronounced enhancement of the drain current (∼600−900μA\sim 600-900 μA∼600−900μA) and a shift in the apparent threshold voltage during laser illumination, reflecting photo induced changes in channel electrostatics. By correlating gate dependent magnetic images with simultaneous electrical measurements, we directly link spatial current distributions to FET transfer characteristics, providing new insight into buried interface transport and non-uniform gating effects in the transistor channel. As the methodology is compatible with top gated FETs, it can be used to map channel current distributions with micrometer resolution in emerging channel materials, such as 2D materials and wide bandgap channels, and establish widefield NV magnetometry as a powerful platform for probing charge transport in transistors and Van der Waals dielectric heterostructures.
Understanding vortex matter in type-II superconductors is central to controlling dissipation and flux pinning in superconducting materials and devices. Here, we use cryogenic scanning nitrogen vacancy magnetometry (NVM) to image Abrikosov vortices in the cuprate superconductors BSCCO-2212 and YBCO under controlled field-cooled conditions. Measurements, which are performed using continuous-wave optically detected magnetic resonance (cw-ODMR) in a closed-cycle cryostat, yield quantitative magnetic-field maps with nanoscale spatial resolution. In BSCCO-2212 at 71 K, we resolve a well-ordered triangular vortex lattice, whose symmetry and spacing are confirmed through 2D Fourier analysis and are consistent with flux quantization. YBCO thin films imaged at 3 K exhibit a more disordered vortex arrangement reflecting stronger pinning, while maintaining quantitative agreement between measured vortex density and the applied magnetic field. These results render our cryogenic scanning NVM a reliable quantitative tool for real-space studies of vortices in high-TcT_cTc​ superconductors, in particular since such a remarkable magnetic resolution has been achieved within relatively short acquisition times of 2 to 4 h.
Many spintronic, magnetic-memory, and neuromorphic devices rely on spatially varying magnetic fields. Quantitatively imaging these fields with full vector information over extended areas remains a major challenge. Existing probes either offer nanoscale resolution at the cost of slow scanning, or widefield imaging with limited vector sensitivity or material constraints. Quantum sensing with nitrogen-vacancy (NV) centers in diamond promises to bridge this gap, but a practical camera-based vector magnetometry implementation on relevant microstructures has not been demonstrated. Here we adapt a commercial widefield microscope to implement a camera-compatible pulsed optically detected magnetic resonance protocol to reconstruct stray-field vectors from microscale devices. By resolving the Zeeman shifts of the four NV orientations, we reconstruct the stray-field vector generated by microfabricated permalloy structures that host multiple stable remanent states. Our implementation achieves a spatial resolution of ≈0.52 μm\approx 0.52 ~μ\mathrm{m}≈0.52 μm across an 83 μm×83 μm83~μ\mathrm{m} \times 83~μ\mathrm{m}83 μm×83 μm field of view and a peak sensitivity of $ (828 \pm 142)~\mathrm{nT\,Hz^{-1}}$, with acquisition times of only a few minutes. These results establish pulsed widefield NV magnetometry on standard microscopes as a practical and scalable tool for routine vector-resolved imaging of complex magnetic devices.