Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2512.19174 · Physical Review Applied

Real-time phase control methods for cold-atom interferometry

Mohamed Guessoum, Nathan Marliere, Charbel Cherfan, Rémi Geiger, Arnaud Landragin

Published Jan 14, 2026• 1 citation
arXivHTMLPDF

Abstract

We present two methods to achieve real-time inertial phase compensation in atom interferometers. Both methods, based on jumps of the position of the retroreflection mirror or frequencies of Raman lasers, demonstrate similar state-of-the-art performance on our cold atom gyroscope, comparable to that of the reference method based on optical phase jumps. These alternative approaches broaden the scope of applications for real-time inertial phase compensation methods in atomic interferometers, particularly for space applications.

DOI
10.1103/4fts-8fp8

Related papers

Atom interferometry at arbitrary orientations and rotation rates

Quentin d’Armagnac de Castanet, Cyrille Des Cognets, Romain Arguel +6 more

The exquisite precision of atom interferometers has sparked the interest of a large community for uses ranging from fundamental physics to geodesy and inertial navigation. However, their implementation for onboard applications is still limited, not least because rotation and acceleration are intertwined in a single phase shift, which makes the extraction of a useful signal more challenging. Moreover, the spatial separation of the wave packets due to rotations leads to a loss of signal. We present an atom interferometer operating over a large range of random angles, rotation rates and accelerations. A model of the expected phase shift allows us to untangle the rotation and acceleration signals. We also implement a real-time compensation system using fiber-optic gyroscopes and a rotating reference mirror to maintain the full contrast of the interferometer. We demonstrate a single-shot sensitivity to acceleration of 24 μg for rotation rates reaching 14° s−1. Cold atoms inertial sensors offer great precision and sensitivity, yet their use in mobile applications has been hindered by the effects of rotations on their measurements. Here, authors demonstrate an atom interferometer operating over a wide range of orientations and rotation rates, thanks to hybridisation with accelerometers and gyroscopes.

arXiv:2402.18988•Nature Communications•Jul 30, 2024•35 citations

New Generation Inertial Navigation Technology:Cold Atom Gyroscope

Mingsheng Zhan

In this paper,we described the progress of cold atom gyroscope.We launched the atoms along the same trajectory accurately and the opposite direction by controlling the frequency of directed digital system circuit.Using stimulated Raman beams,we operated the cold atoms and realized the atom interferometer fringes.With this configuration,it will greatly eliminate the common mode noise caused by uncertainty factor,such as the phase of the Raman laser beams,the gravity acceleration.It will significantly improve the precision in our experiment.The atom gyroscope will give a new way for the inertial navigation technology in the future.

Gnss World of China•Jan 1, 2010•1 citation

High-sensitivity cold-atom gyroscope with real-time vibration compensation

Denis Savoie, Matteo Altorio, Bess Fang +2 more

Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations

High-sensitivity cold-atom gyroscope with real-time vibration compensation

Matteo Altorio, Denis Savoie, Bess Fang +2 more

Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.

•Sep 26, 2017•0 citations

CLEO®/Europe-EQEC 2017 active control of laser wavefronts in atom interferometers

Azer Trimeche, Mehdi Langlois, Sébastien Merlet +1 more

Wavefront aberrations are today the main contribution in the inaccuracy budget of best cold atom interferometers [1, 2], based on laser beam splitters, and constitute an important limit for their long-term stability [1]. They prevent from exploiting the full potential of these atom interferometers. In this work, we report on the active control of laser wavefronts for atom interferometry and demonstrate in a proof-of-principle experiment the compensation of their aberrations using, for the first time, a deformable mirror in a cold atom inertial sensor.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations

Real-time compensation scheme for the accurate measurement of the differential phase in a dual-atom-interferometer gyroscope

Ze-Xi Lu, Zhan-Wei Yao, Honghui Chen +10 more

A dual-atom-interferometer gyroscope has high sensitivity for accurate rotation measurements because of its immunity to common-mode noise. However, a measurement error is induced as the common phase noise, e.g., vibration noise, increases. In this work, we demonstrated a real-time compensation (RTC) scheme to improve the accuracy of measurements of the differential phase in dual atom interferometers. The vibration noise was measured by two seismometers and its induced phase shift was fed back to the Raman lasers after this shift was calculated based on the sensitivity function of the atom interferometers. After the RTC module was applied, the interference signals obtained via the square modulation method were stabilized at their midfringe points, which caused the vibration-induced phase noise for each of the atom interferometers to decrease from 495 mrad to 165 mrad. The differential phase error obtained by the dual atom interferometers and two seismometers was reduced from 114.8 mrad to 49.6 mrad, which implies that the rotation measurement error was improved by a factor of 2.3. This work paves the way to accurately measuring the rotation signal and has promising applications in fields of precision measurements.

Physical Review A•Mar 10, 2025•3 citations
We present two methods to achieve real-time inertial phase compensation in atom interferometers. Both methods, based on jumps of the position of the retroreflection mirror or frequencies of Raman lasers, demonstrate similar state-of-the-art performance on our cold atom gyroscope, comparable to that of the reference method based on optical phase jumps. These alternative approaches broaden the scope of applications for real-time inertial phase compensation methods in atomic interferometers, particularly for space applications.
The exquisite precision of atom interferometers has sparked the interest of a large community for uses ranging from fundamental physics to geodesy and inertial navigation. However, their implementation for onboard applications is still limited, not least because rotation and acceleration are intertwined in a single phase shift, which makes the extraction of a useful signal more challenging. Moreover, the spatial separation of the wave packets due to rotations leads to a loss of signal. We present an atom interferometer operating over a large range of random angles, rotation rates and accelerations. A model of the expected phase shift allows us to untangle the rotation and acceleration signals. We also implement a real-time compensation system using fiber-optic gyroscopes and a rotating reference mirror to maintain the full contrast of the interferometer. We demonstrate a single-shot sensitivity to acceleration of 24 μg for rotation rates reaching 14° s−1. Cold atoms inertial sensors offer great precision and sensitivity, yet their use in mobile applications has been hindered by the effects of rotations on their measurements. Here, authors demonstrate an atom interferometer operating over a wide range of orientations and rotation rates, thanks to hybridisation with accelerometers and gyroscopes.
In this paper,we described the progress of cold atom gyroscope.We launched the atoms along the same trajectory accurately and the opposite direction by controlling the frequency of directed digital system circuit.Using stimulated Raman beams,we operated the cold atoms and realized the atom interferometer fringes.With this configuration,it will greatly eliminate the common mode noise caused by uncertainty factor,such as the phase of the Raman laser beams,the gravity acceleration.It will significantly improve the precision in our experiment.The atom gyroscope will give a new way for the inertial navigation technology in the future.
Wavefront aberrations are today the main contribution in the inaccuracy budget of best cold atom interferometers [1, 2], based on laser beam splitters, and constitute an important limit for their long-term stability [1]. They prevent from exploiting the full potential of these atom interferometers. In this work, we report on the active control of laser wavefronts for atom interferometry and demonstrate in a proof-of-principle experiment the compensation of their aberrations using, for the first time, a deformable mirror in a cold atom inertial sensor.
A dual-atom-interferometer gyroscope has high sensitivity for accurate rotation measurements because of its immunity to common-mode noise. However, a measurement error is induced as the common phase noise, e.g., vibration noise, increases. In this work, we demonstrated a real-time compensation (RTC) scheme to improve the accuracy of measurements of the differential phase in dual atom interferometers. The vibration noise was measured by two seismometers and its induced phase shift was fed back to the Raman lasers after this shift was calculated based on the sensitivity function of the atom interferometers. After the RTC module was applied, the interference signals obtained via the square modulation method were stabilized at their midfringe points, which caused the vibration-induced phase noise for each of the atom interferometers to decrease from 495 mrad to 165 mrad. The differential phase error obtained by the dual atom interferometers and two seismometers was reduced from 114.8 mrad to 49.6 mrad, which implies that the rotation measurement error was improved by a factor of 2.3. This work paves the way to accurately measuring the rotation signal and has promising applications in fields of precision measurements.