arXiv:2510.27398 · Physical Review Applied

Complete characterization of beam deflection based on a double weak-value-amplification system

Yu Wang, Rongguo Yang, Jing Zhang, Chenzhen Luo, Xiaomin Liu, Kui Liu, Jiangrui Gao

Published May 28, 2026• 0 citations
arXivHTMLPDF

Abstract

The precise measurement of spatial attitude parameters is critical for applications in inertial navigation, industrial monitoring, instrument calibration, quantum metrology, etc. In this work, we theoretically investigate and experimentally realize the simultaneous measurement of the yaw and pitch angles using a Hermite-Gaussian-postselected double weak value system integrated with two sets of high-order-mode balanced homodyne detections, thereby achieving a complete characterization of the beam deflection. Signals of the yaw and pitch angles that are involved in TEM$_{10}$ and TEM$_{01}$ modes output from two dark ports of the system can be measured independently. As a result, the obtained minimum measurable yaw and pitch angles of beam deflection are 83 prad and 89 prad, respectively. Meanwhile, the corresponding displacements are 0.79 pm and 0.85 pm, respectively. This work expands the beam deflection measurement to two dimensions, which provides a new insight for future high-precision multi-parameter spatial precise detection.

DOI
10.1103/symq-cg3s

Related papers

High-Precision Multiparameter Weak Measurement with Hermite-Gaussian Pointer

Binke Xia, Jingzheng Huang, Chen Fang +2 more

The weak-value amplification technique has been proved to be useful for precision metrology in both theory and experiment. To explore the ultimate performance of weak-value amplification for multiparameter estimation, we investigate a general weak-measurement formalism with the assistance of the high-order Hermite-Gaussian (H-G) pointer and the quantum Fisher information matrix. Theoretical analysis shows that the ultimate precision of our scheme is improved by a factor of the square root of $2n+1$, where $n$ is the order of the Hermite-Gaussian mode. Moreover, the parameters' estimation precision can approach the precision limit with the maximum-likelihood estimation method and the homodyne method. We also present a proof-of-principle experimental setup to validate the H-G--pointer theory and explore its potential applications in precision metrology.

arXiv:2310.06605•Physical Review Applied•Mar 9, 2020•25 citations

Small-tilt measurement based on weak-value-amplification with balanced homodyne detection

ChaoXia Zhang, YongLang Lai, Rongguo Yang +4 more

We experimentally realize a great precision enhancement in the small-tilt measurement by using a Sagnac interferometer and balanced homodyne detection (BHD) of high-order optical modes, together with the weak-value amplification (WVA) technique. Smaller minimum measurable tilt and higher signal-to-noise ratio can be obtained by using BHD, compared with the split detection. The precision of 3.8 nrad can be obtained under our present experimental condition. It is shown that combining WVA technique and BHD can strengthen each other's advantages and can behave better for some special application scenarios, such as extremely weak output, wider measurement bandwidth, etc. Moreover, the precision can be further enhanced by experimental parameter optimization.

arXiv:2210.14553•Applied Physics Letters•Jan 16, 2023•10 citations

Tilt Measurement at the Quantum Cramer–Rao Bound Using a Higher-Order Hermite–Gaussian Mode

Li Zhi, Yijian Wang, Hengxin Sun +2 more

The quantum Cramer–Rao bound (QCRB) provides an ultimate precision limit in parameter estimation. The sensitivity of spatial measurements can be improved by using the higher-order Hermite–Gaussian mode. However, to date, the QCRB-saturating tilt measurement has not been realized. Here, we experimentally demonstrate tilt measurements using a higher-order HG40 mode as the probe beam. Using the balanced homodyne detection with an optimal local beam, which involves the superposition of high-order HG30 and HG50 modes, we demonstrate the precision of the tilt measurement approaching the QCRB. The signal-to-noise ratio of the tilt measurement is enhanced by 9.2 dB compared with the traditional method using HG00 as the probe beam. This scheme is more practical and robust to losses, which has potential applications in areas such as laser interferometer gravitational-wave observatories and high-sensitivity atomic force microscopes.

Photonics•May 17, 2023•6 citations

Experimentally quantifying the advantages of weak-value-based metrology

Gerardo I. Viza, Julián Martínez-Rincón, G. B. Alves +2 more

We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By introducing controlled external transverse detector modulations and transverse beam deflection momentum modulations, we quantify the mitigation of these sources in the weak-value-based experiment versus the standard focusing experiment. The experiments are compared using a combination of deterministic and stochastic methods. In all cases, the weak-value technique performs the same or better than the standard technique by up to two orders of magnitude in precision for our parameters. We further measure the statistical efficiency of the weak-value-based technique. By postselecting on $1%$ of the photons, we obtain $99%$ of the available Fisher information of the beam deflection parameter.

arXiv:1410.8461•Physical Review A•Sep 22, 2015•127 citations

Precise modulation of beam deflection via weak measurement

Xu Han

Weak measurement technology can be used to achieve ultra-precision modulation of variables. Based on this, to achieve precise modulation of beam deflection, we establish a model of beam propagation using weak measurement, theoretically deduce the general formula of the deflection angle, and illustrate the general process of precise modulation of the angular shift of the beam. By controlling the post-selection state of the weak measurement, the angular shift of the beam can be precisely regulated. The deflection angle is proportional to the imaginary part of the weak value. We describe a simulation and discuss how precise angle tuning can be achieved by controlling experimental parameters.

International Conference on Laser, Optics and Optoelectronic Technology (LOPET)•Oct 14, 2022•0 citations

Accurately identifying mode indices of Laguerre–Gaussian beams via weak measurements

Bo Wang, Pengyun Li, Tian Chen +1 more

Abstract We propose an efficient method to accurately identify two mode indices ( p and l ) of Laguerre–Gaussian (LG) beams simultaneously with weak value measurement (WVM). Concise relations between the spatial displacements from the WVM and two mode indices of LG beams have been obtained. Compared with the traditional measurements, the advantage of using our method is that LG beams with large p and l can be identified precisely. A joint spatial WVM with a looser approximate condition has been presented, which realizes better identification than the individual spatial WVM with correction terms or strict approximation. Furthermore, the signal-to-noise ratio (SNR) of the spatial WVM is also discussed.

Journal of Optics•Mar 28, 2017•5 citations
The precise measurement of spatial attitude parameters is critical for applications in inertial navigation, industrial monitoring, instrument calibration, quantum metrology, etc. In this work, we theoretically investigate and experimentally realize the simultaneous measurement of the yaw and pitch angles using a Hermite-Gaussian-postselected double weak value system integrated with two sets of high-order-mode balanced homodyne detections, thereby achieving a complete characterization of the beam deflection. Signals of the yaw and pitch angles that are involved in TEM10_{10}10​ and TEM01_{01}01​ modes output from two dark ports of the system can be measured independently. As a result, the obtained minimum measurable yaw and pitch angles of beam deflection are 83 prad and 89 prad, respectively. Meanwhile, the corresponding displacements are 0.79 pm and 0.85 pm, respectively. This work expands the beam deflection measurement to two dimensions, which provides a new insight for future high-precision multi-parameter spatial precise detection.
The weak-value amplification technique has been proved to be useful for precision metrology in both theory and experiment. To explore the ultimate performance of weak-value amplification for multiparameter estimation, we investigate a general weak-measurement formalism with the assistance of the high-order Hermite-Gaussian (H-G) pointer and the quantum Fisher information matrix. Theoretical analysis shows that the ultimate precision of our scheme is improved by a factor of the square root of 2n+12n+12n+1, where nnn is the order of the Hermite-Gaussian mode. Moreover, the parameters' estimation precision can approach the precision limit with the maximum-likelihood estimation method and the homodyne method. We also present a proof-of-principle experimental setup to validate the H-G--pointer theory and explore its potential applications in precision metrology.
We experimentally realize a great precision enhancement in the small-tilt measurement by using a Sagnac interferometer and balanced homodyne detection (BHD) of high-order optical modes, together with the weak-value amplification (WVA) technique. Smaller minimum measurable tilt and higher signal-to-noise ratio can be obtained by using BHD, compared with the split detection. The precision of 3.8 nrad can be obtained under our present experimental condition. It is shown that combining WVA technique and BHD can strengthen each other's advantages and can behave better for some special application scenarios, such as extremely weak output, wider measurement bandwidth, etc. Moreover, the precision can be further enhanced by experimental parameter optimization.
The quantum Cramer–Rao bound (QCRB) provides an ultimate precision limit in parameter estimation. The sensitivity of spatial measurements can be improved by using the higher-order Hermite–Gaussian mode. However, to date, the QCRB-saturating tilt measurement has not been realized. Here, we experimentally demonstrate tilt measurements using a higher-order HG40 mode as the probe beam. Using the balanced homodyne detection with an optimal local beam, which involves the superposition of high-order HG30 and HG50 modes, we demonstrate the precision of the tilt measurement approaching the QCRB. The signal-to-noise ratio of the tilt measurement is enhanced by 9.2 dB compared with the traditional method using HG00 as the probe beam. This scheme is more practical and robust to losses, which has potential applications in areas such as laser interferometer gravitational-wave observatories and high-sensitivity atomic force microscopes.
We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By introducing controlled external transverse detector modulations and transverse beam deflection momentum modulations, we quantify the mitigation of these sources in the weak-value-based experiment versus the standard focusing experiment. The experiments are compared using a combination of deterministic and stochastic methods. In all cases, the weak-value technique performs the same or better than the standard technique by up to two orders of magnitude in precision for our parameters. We further measure the statistical efficiency of the weak-value-based technique. By postselecting on 11%1 of the photons, we obtain 9999%99 of the available Fisher information of the beam deflection parameter.
Weak measurement technology can be used to achieve ultra-precision modulation of variables. Based on this, to achieve precise modulation of beam deflection, we establish a model of beam propagation using weak measurement, theoretically deduce the general formula of the deflection angle, and illustrate the general process of precise modulation of the angular shift of the beam. By controlling the post-selection state of the weak measurement, the angular shift of the beam can be precisely regulated. The deflection angle is proportional to the imaginary part of the weak value. We describe a simulation and discuss how precise angle tuning can be achieved by controlling experimental parameters.
Abstract We propose an efficient method to accurately identify two mode indices ( p and l ) of Laguerre–Gaussian (LG) beams simultaneously with weak value measurement (WVM). Concise relations between the spatial displacements from the WVM and two mode indices of LG beams have been obtained. Compared with the traditional measurements, the advantage of using our method is that LG beams with large p and l can be identified precisely. A joint spatial WVM with a looser approximate condition has been presented, which realizes better identification than the individual spatial WVM with correction terms or strict approximation. Furthermore, the signal-to-noise ratio (SNR) of the spatial WVM is also discussed.