Solid-state color centers embedded in diamond, silicon carbide (SiC) and other host-matrices offer a promising platform for nanoscale quantum sensing. Sometimes a relatively strong transverse zero-field splitting (ZFS) is introduced in a color center due to its local strain and low symmetry of the host structure. While clock transitions induced by transverse zero-field splitting (ZFS) serve as a method to prolong the coherence time, the Zeeman sub-levels of solid-state color centers become insensitive to first-order magnetic field signals, thereby limiting their utility as magnetometers. In this work, we address this challenge and achieve wide band AC field detection spanning from hundreds of kHz to hundreds of MHz by utilizing a combination of orthogonal microwaves and phase modulation at different frequencies. Our control method effectively suppresses the system noise and the amplitude fluctuation of the driving field, which extends the coherence time of the quantum system.
Solid-state color centers embedded in diamond, silicon carbide (SiC) and other host-matrices offer a promising platform for nanoscale quantum sensing. Sometimes a relatively strong transverse zero-field splitting (ZFS) is introduced in a color center due to its local strain and low symmetry of the host structure. While clock transitions induced by transverse zero-field splitting (ZFS) serve as a method to prolong the coherence time, the Zeeman sub-levels of solid-state color centers become insensitive to first-order magnetic field signals, thereby limiting their utility as magnetometers. In this work, we address this challenge and achieve wide band AC field detection spanning from hundreds of kHz to hundreds of MHz by utilizing a combination of orthogonal microwaves and phase modulation at different frequencies. Our control method effectively suppresses the system noise and the amplitude fluctuation of the driving field, which extends the coherence time of the quantum system.
Color centers in diamond and silicon carbide, and molecular spins through a host matrix control are promising for nanoscale quantum sensing because they can be optically addressable, coherently controllable, and placed proximate to the targets. However, large transverse zero-field splitting (ZFS) is often inevitable due to their intrinsic symmetry and/or the high local strains of the host matrix. Although spin coherence can be extended due to magnetic noise-insensitive clock transitions at a vanishing magnetic field, the eigenstates of these sensors are not sensitive to weak magnetic signals in the linear order. We address this challenge by employing a combination of radio-frequency (rf) field driving along the NV orientation and microwave dynamic decoupling pulse sequences. Radio-frequency driving can effectively mitigate the transverse ZFS effect and enhance the NV center's sensitivity to ac magnetic field signals. This combination not only suppresses environmental noise but also enables quantum frequency mixing between the transverse ZFS and the signal. It also offers the potential to detect weak ac signals at intermediate and high frequencies with high resolution, a task difficult to achieve using conventional methods.
Nitrogen-vacancy (NV) centers in diamond are promising quantum sensors for AC magnetic fields. However, conventional dynamical-decoupling-based magnetometry becomes technically demanding at high frequencies because of the requirement for increasingly short and high-power microwave pulses. This paper describes an AC magnetometry technique based on continuous-wave optically detected magnetic resonance (CW-ODMR) measurements, which enables the detection of signals in the hundred-MHz range. By applying a strong static magnetic field transverse to the NV axis, the energy separation between the relevant electron-spin states was tuned and resonantly coupled with the target radiofrequency (RF) magnetic field, thereby forming RF-dressed states. Unlike pulsed dynamical-decoupling schemes, this approach does not require high-power microwave pulse sequences. The key feature of our method is that the detectable frequency can be tuned by controlling the bias magnetic field strength. Using this methodology, we have experimentally achieved the frequency-tunable detection of AC magnetic fields from 14.4-632 MHz. The sensitivity was 0.558 uT/Hz^(0.5) at 14.4 MHz and 24.4 uT/Hz^(0.5) at 632 MHz. We characterized the field-dependent ODMR contrast and linewidth, and found that their degradation at large transverse fields is a important factor limiting the high-frequency sensitivity. These results establish a simple CW-ODMR approach for widely tunable RF magnetic-field sensing without high-power pulsed spin control.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.
Silicon carbide is an emerging platform for quantum technologies that provides wafer scale and low-cost industrial fabrication. The material also hosts high-quality defects with long coherence times that can be used for quantum computation and sensing applications. Using an ensemble of nitrogen-vacancy centers and an XY8-2 correlation spectroscopy approach, we demonstrate a room-temperature quantum sensing of an artificial AC field centered at ~900 kHz with a spectral resolution of 10 kHz. Implementing the synchronized readout technique, we further extend the frequency resolution of our sensor to 0.01 kHz. These results pave the first steps for silicon carbide quantum sensors toward low-cost nuclear magnetic resonance spectrometers with a wide range of practical applications in medical, chemical, and biological analysis.
Nitrogen—Vacancy (NV) center in diamond can detect tiny magnetic field due to relative long coherence time even at room temperature. Its optical accessibility and capability of thin-film formation provide us an interesting sensing modality such as wide field imaging. We have reported phase sensitive protocol for ac magnetic field designed for wide field setup.[1] In this study we demonstrate an application of phase sensitive protocol; measuring distribution of ac magnetic field strength by phase sensing. Previous methods of multi-pulse quantum sensing such as XY8 realize quite high sensitivity of ac magnetic field. Since XY8 has dependencies on strength and phase of ac magnetic field, it is necessary to adjust ac phase to an optimal point in order to obtain a best sensitivity, and we cannot distinguish the effect of amplitude and phase. Recent studies have showed utilizing time-domain information is effective for improving frequency resolution of quantum sensing,[2,3] and we found same technique is also effective for simultaneous measurement of strength and phase. Here we propose a robust method for amplitude estimation by phase sensing. We added another signal for reference, then sensing phase difference between target signal and reference can be converted into amplitude. Conventional XY8 sensing is based upon fluorescence measurement which can be affected easily by many obstacles such as stray light, autofluorescence, and fringes of excitation laser. In the other hand, our method can be more robust because it is based on phase measurement. Nothing can change the phase except absorption of ac signal. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Mizuno et al., AIP advances 2018 [2][3] Boss, Schmitt
The work presented in this thesis revolves around quantum enhanced magnetic field sensing. The core of the study is the nitrogen-vacancy (NV) center, a point defect in the diamond lattice with atomic like properties and magnetic field susceptibility. The central task was to develop control schemes and protocols to enhance the lifetime and the coherences of the NV center with the overall goal of enhancing the capabilities of this sensor in the field of magnetometry. In order to realize complex protocols, a sophisticated software control of the measurement setup is required. A general software framework, termed Qudi, was designed and developed from scratch to improve drastically the measurement abilities and to facilitate the transfer of knowledge between the measurement protocols and the underlying physical idea. The transparent character of the core code, fully open to the scientific community, is serving as rigorous framework to reduce the complexity of the setup configuration by a fundamental separation of tasks. As a consequence, the general idea of this framework is not limited to experiments with color centers in diamond, but can find application in any laboratory environment. The measurement of magnetic fields in the high-frequency GHz regimes is challenging. In this thesis, a continuous dynamical decoupling protocol is developed and implemented, which extends the capabilities of the NV sensor to probe GHz signals with a narrow bandwidth. Moreover, the protocol protects the system from noise, attributed to the drive, and from external magnetic noise thereby prolonging the coherence time and reaching the lifetime limitation of the quantum states. We measured a coherence time of 1.43 ms at room temperature in a diamond crystal with a natural abundance of 13C atoms, resulting in a smallest detectable magnetic field strength of 4 nT at 1.6 GHz. Creating a protected qubit from a three-level system requires multiple drive fields addressing different transition frequencies. Continuous dynamical decoupling can protect the system from external magnetic noise, but typically introduces large drive noise to the system. The combination of on-resonant and off-resonant driving fields serves an approach to circumvent the challenges associated with drive noise. While on-resonant drive maintains a large energy gap in order to protect the sensor from external magnetic noise, the off-resonant drive creates AC-Stark shifted energy levels, thereby significantly reducing the amount of drive noise on the three-level system. We experimentally demonstrate an improvement in coherence time, which is only limited by the second order contributions of the magnetic field noise while suppressing entirely the drive noise contributions. Further improvement can be achieved by a mere increase of the drive field as its noise is efficiently decoupled from the sensor.