Abstract Quantum imaging is an advanced method for microscopy or investigating the optical properties of materials or bio-medical inspections with high accuracy, low noise, and extremely low photo-damage. In previous work, we proposed a quantum imaging technique, in which variations in polarization angle due to reflection or transmission at the sample enhance image contrast in the second-order autocorrelation function at zero delay g 2(0). However, the image resolution observed was not satisfactory. In this report, to improve the image quality, the parameters such as coincidence window was optimized to distinguish photon statistics effectively due to change in polarization angle and the objective lens was utilized to focus the entangled photon beams. These modifications enabled optical imaging by accurately detecting slight polarization variations in different media. Although this method is effective for various samples, it has certain limitations for samples that exhibit polarization disturbances, such as those involving photon scattering. Nevertheless, the proposed approach demonstrates superior imaging performance under noisy conditions and low illumination, offering promising possibilities for high-quality quantum imaging applications.
Abstract Quantum imaging is an advanced method for microscopy or investigating the optical properties of materials or bio-medical inspections with high accuracy, low noise, and extremely low photo-damage. In previous work, we proposed a quantum imaging technique, in which variations in polarization angle due to reflection or transmission at the sample enhance image contrast in the second-order autocorrelation function at zero delay g 2(0). However, the image resolution observed was not satisfactory. In this report, to improve the image quality, the parameters such as coincidence window was optimized to distinguish photon statistics effectively due to change in polarization angle and the objective lens was utilized to focus the entangled photon beams. These modifications enabled optical imaging by accurately detecting slight polarization variations in different media. Although this method is effective for various samples, it has certain limitations for samples that exhibit polarization disturbances, such as those involving photon scattering. Nevertheless, the proposed approach demonstrates superior imaging performance under noisy conditions and low illumination, offering promising possibilities for high-quality quantum imaging applications.
With the advancement of non-classical light sources such as single-photon and entangled-photon sources, innovative microscopy based on quantum principles has been proposed for traditional microscopy. This paper introduces the experimental demonstration of a quantum polarization microscopic technique that incorporates a quantum-entangled photon source. Although the point that employs the variation in polarization angle due to reflection or transmission at the sample is similar to classical polarization microscopy, the method for constructing the image contrast is significantly different. The image contrast is constructed by the coincidence count of signal and idler photons. In the case that the coincidence count is recorded from both the signal and idler photons, the photon statistics resemble a thermal state, similar to the blackbody radiation, but with a significantly higher peak intensity in the second-order autocorrelation function at zero delay that is derived from the coincidence count, while, when the coincidence count is taken from either the signal or idler photon only, although the photon state exhibits a thermal state again, the photon statistics become more dispersive and result in a lower peak intensity of the autocorrelation function. These different thermal states can be switched by slightly changing the photon polarization, which is suddenly aroused within a narrow range of the analyzer angle. The autocorrelation function g2(0) at the thermal state exhibits a sensitivity that is three times higher compared to the classical coincidence count rate, and this concept can be effectively utilized to enhance the contrast of the image. One of the key achievements of our proposed method is ensuring a low power of illumination (in the order of Pico-joules) for constructing the image. In addition, the robustness without any precise setup is also favorable for practical use. This polarization microscopic technique can provide a superior imaging technique compared to the classical method, opening a new frontier for research in material sciences, biology, and other fields requiring high-resolution imaging.
Polarimetric imaging, a technique that captures the invisible polarization-related properties of given materials, has broad applications from fundamental physics to advanced fields such as target recognition, stress detection, biomedical diagnosis and remote sensing. The introduction of quantum sources into classical imaging systems has demonstrated distinct advantages, yet few studies have explored their combination with polarimetric imaging. In this study, we present a quantum polarimetric imaging system that integrates polarization-entangled photon pairs into a polarizer-sample-compensator-analyzer-typed polarimeter. Our system visualizes the birefringence properties of a periodical-distributed anisotropic material under decreasing illumination levels and diverse disturbing light sources. Compared to the classical system, the quantum approach reveals the superior sensitivity and robustness in low-light conditions, particularly useful in biomedical studies where the low illumination and non-destructive detection are urgently needed. The study also highlights the nonlocality of entangled photons in birefringence measurement, indicating the potential of quantum polarimetric system in the remote sensing domain.
We use entangled photons as the light source in a normal microscope. Using this quantum illumination improves both the resolution and noise rejection in the image. The resolution of any classical imaging system is limited by the diffraction created by the finite size of the imaging lens. By using a light source that emits pairs of entangled photons and carefully controlling a camera that is capable of detecting single photons it is possible to observe these photons arriving two-by-two. Applying camera analysis software to log only these two-by-two events one can form an image from the mid-point (bisector) of each of these pair events. The image formed from the sum of all these bisectors has an improved resolution that surpasses the classical limit. Another advantage of using a quantum illumination is that it allows the two-by-two events from entangled photon pairs to be distinguished from background (classical) light and sensor noise. When processed in this way the resulting image is free of camera noise and any background light may be eliminated. The use of a quantum illumination protocol such as that used here results in the elimination of background light and therefore allows the development of the optical equivalent of quantum radar – a quantum enhanced LIDAR scheme. Using quantum illumination, combined with commercially available cameras that are sensitive to single photons creates a new approach to super-resolution and low noise microscopy. Imaging through noise with quantum illumination, T Gregory, P-A Moreau, E Toninelli, and M J Padgett, Science Advances 6, eaay2652 (2020) Resolution-enhanced quantum imaging by centroid estimation of biphotons, E Toninelli, P-A Moreau, T Gregory, A Mihalyi, M Edgar, N Radwell, and M J Padgett, Optica 6, 347-353 (2019)
Two-photon interference in a Hong-Ou-Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples.
Quantum imaging is emerging as a transformative approach for biomedical applications, applying nonclassical properties of light, such as entanglement, squeezing, and quantum correlations, to overcome fundamental limits of conventional techniques. These methods promise superior spatial resolution, enhanced signal-to-noise ratios, improved phase sensitivity, and reduced radiation dose, for potentially safer and more precise imaging for delicate biological samples. Here, we present an overview of quantum optical biomedical imaging technologies as well as quantum-inspired imaging methods, including quantum optical coherence tomography, quantum optical microscopy, ghost imaging, multi-parameter quantum imaging, and imaging with quantum-grade cameras. We describe the operating principles, biomedical applications, and unique advantages of each approach, along with the specific challenges for their translation into real-life practice. This review aims to guide future research toward advancing quantum imaging from experimental demonstrations to impactful biomedical tools.
Entangled photons enable quantum imaging to surpass classical limits in resolution and noise. To address long-standing challenges in quantum imaging (such as low signal-to-noise, limited resolvable pixels, and difficulty imaging biological samples), we present imaging by coincidence from entanglement (ICE). ICE leverages spatial and polarization entanglement to enhance resolution, support biological imaging, and quantify birefringence properties. Polarization entanglement enables remote, quantitative measurement of both phase retardation and principal axis orientation without changing input polarization. ICE achieves up to 25-fold stray light suppression relative to classical imaging. We further introduce wide-field quantum microscopy by coincidence (QMC) using symmetric, balanced paths to achieve Heisenberg-limited super-resolution, with up to 155-fold suppression of stray light and improved speed and contrast-to-noise ratio. Together, QMC and ICE represent significant advances in quantum bioimaging, offering low-light, high-resolution, and noninvasive imaging capabilities with potential impact in life sciences and remote sensing.