Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2501.03478 · Photonics

Demonstration of Quantum Polarized Microscopy Using an Entangled-Photon Source

Mousume Samad, Maki Shimizu, Yasuto Hijikata

Published Jan 31, 2025• 6 citations
arXivHTMLPDF

Abstract

With the advancement of non-classical light sources such as single-photon and entangled-photon sources, innovative microscopy based on quantum principles has been proposed for traditional microscopy. This paper introduces the experimental demonstration of a quantum polarization microscopic technique that incorporates a quantum-entangled photon source. Although the point that employs the variation in polarization angle due to reflection or transmission at the sample is similar to classical polarization microscopy, the method for constructing the image contrast is significantly different. The image contrast is constructed by the coincidence count of signal and idler photons. In the case that the coincidence count is recorded from both the signal and idler photons, the photon statistics resemble a thermal state, similar to the blackbody radiation, but with a significantly higher peak intensity in the second-order autocorrelation function at zero delay that is derived from the coincidence count, while, when the coincidence count is taken from either the signal or idler photon only, although the photon state exhibits a thermal state again, the photon statistics become more dispersive and result in a lower peak intensity of the autocorrelation function. These different thermal states can be switched by slightly changing the photon polarization, which is suddenly aroused within a narrow range of the analyzer angle. The autocorrelation function g2(0) at the thermal state exhibits a sensitivity that is three times higher compared to the classical coincidence count rate, and this concept can be effectively utilized to enhance the contrast of the image. One of the key achievements of our proposed method is ensuring a low power of illumination (in the order of Pico-joules) for constructing the image. In addition, the robustness without any precise setup is also favorable for practical use. This polarization microscopic technique can provide a superior imaging technique compared to the classical method, opening a new frontier for research in material sciences, biology, and other fields requiring high-resolution imaging.

DOI
10.3390/photonics12020127

Related papers

A study on the improvements and limitations of image quality in quantum polarization microscopy using an entangled-photon source

Mousume Samad, Maki Shimizu, Yasuto Hijikata

Abstract Quantum imaging is an advanced method for microscopy or investigating the optical properties of materials or bio-medical inspections with high accuracy, low noise, and extremely low photo-damage. In previous work, we proposed a quantum imaging technique, in which variations in polarization angle due to reflection or transmission at the sample enhance image contrast in the second-order autocorrelation function at zero delay g 2(0). However, the image resolution observed was not satisfactory. In this report, to improve the image quality, the parameters such as coincidence window was optimized to distinguish photon statistics effectively due to change in polarization angle and the objective lens was utilized to focus the entangled photon beams. These modifications enabled optical imaging by accurately detecting slight polarization variations in different media. Although this method is effective for various samples, it has certain limitations for samples that exhibit polarization disturbances, such as those involving photon scattering. Nevertheless, the proposed approach demonstrates superior imaging performance under noisy conditions and low illumination, offering promising possibilities for high-quality quantum imaging applications.

arXiv:2505.05457•Japanese Journal of Applied Physics•Jul 29, 2025•1 citation

Quantum image scanning microscopy: concept and considerations towards applicability

Ron Tenne, Yonatan Israel, Alexander Krupiński‐Ptaszek +5 more

Technological advancements in the creation, manipulation and detection of quantum states of light have motivated the application of such states to overcome classical limits in sensing and imaging. In particular, there has been a surge of recent interest in super-resolution imaging based on principles of quantum optics. However, the application of such schemes for practical imaging of biological samples is demanding in terms of signal-to-noise ratio, speed of acquisition and robustness with respect to sample labeling. Here, we re-introduce the concept of quantum image scanning microscopy (Q-ISM), a super-resolution method that enhances the classical image scanning microscopy (ISM) method by measuring photon correlations. Q-ISM was already utilized to achieve super-resolved images of a biological sample labeled with fluorescent nanoscrystals whose contrast is based entirely on a quantum optical phenomenon, photon antibunching. We present here an experimental demonstration of the method and discuss with further details its prospects for application in life science microscopy.

Optical and Quantum Sensing and Precision Metrology II•Mar 1, 2019•0 citations

Quantum Imaging of Birefringent Samples using Hong-Ou-Mandel Interference

Carolina Gonçalves, Tiago D. Ferreira, Catarina S. Monteiro +1 more

Two-photon interference in a Hong-Ou-Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples.

quant-pharXiv:2512.19637•APL Photonics•Dec 23, 2025•2 citations

Radial polarization imaging of entangled biphoton state

Jiung Kim, Jeeseong Hwang, Martin Y. Sohn

Polarization entanglement of single photons is a key element to enable quantum 2.0 applications, such as quantum computing, quantum networks, and quantum sensing. Verification and fidelity assessment of the entanglement state are typically performed by sequential coincidence measurements with single-pixel photon detectors. Quantum imaging techniques that use single-photon imaging cameras for visualizing an entangled biphoton state and calculating Bell's inequality have been reported. Their performances are limited for practical use due to low photon flux and low speed. Here, we introduce a new approach to image polarization-entangled biphoton states using radial polarizations, which enables rapid high-performance entanglement measurement. An intensified single-photon counting camera (SPCC) captures a single image with multiple polarizations imposed by a radial wave plate, which converts a linear polarization of single photons to radial polarizations. The coincidence photon image is rapidly taken with the SPCC in the integrate-on-chip mode, which is triggered by the idler photons set at a specific polarization angle. Bell's inequality is calculated directly from four coincidence images that show polarization correlation. Our technique not only visualizes the entangled polarization state but also enables fast full Bell-type evaluation of photonic polarization entanglement. We envision that our approach may be instrumental for developing advanced polarization-entangled photon sources and polarization-entangled quantum systems, which in turn would advance fundamental research involving dynamic photon-matter interactions.

APL Photonics•Jun 1, 2025•2 citations

Two-Photon Fluorescence Microscopy at Extremely Low Excitation Intensity: The Power of Quantum Correlations

Oleg P. Varnavski, Theodore G. Goodson III

Quantum entanglement has been shown to imply correlations stronger than those allowed by classical models. The possibility of performing tasks that are classically impossible has made quantum entanglement a powerful resource for the development of novel methods and applications in various fields of research such as quantum computing, quantum cryptography, and quantum metrology. There is a great need for the development of next generation instrumentation and technologies utilizing entangled quantum light. Among the many applications of nonclassical states of light, nonlinear microscopy has the potential to make an impact in broad areas of science from physics to biology. Here, the microscopic image created by the fluorescence selectively excited by the process of the entangled two-photon absorption is reported. Entangled two-photon microscopy offers nonlinear imaging capabilities at an unprecedented low excitation intensity 10 7, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. The nonmonotonic dependence of the image on the femtosecond delay between the components of the entangled photon pair is demonstrated. This delay dependence is a result of specific quantum interference effects associated with the entanglement and this is not observable with classical excitation light. In combination with novel spectroscopic capabilities provided by a nonclassical light excitation, this is of critical importance for sensing and biological applications.

Journal of the American Chemical Society•Jul 9, 2020•93 citations

Quantum-enhanced super-resolution bioimaging: breaking the diffraction barrier with entangled photons

Lihong V. Wang

Entangled photons enable quantum imaging to surpass classical limits in resolution and noise. To address long-standing challenges in quantum imaging (such as low signal-to-noise, limited resolvable pixels, and difficulty imaging biological samples), we present imaging by coincidence from entanglement (ICE). ICE leverages spatial and polarization entanglement to enhance resolution, support biological imaging, and quantify birefringence properties. Polarization entanglement enables remote, quantitative measurement of both phase retardation and principal axis orientation without changing input polarization. ICE achieves up to 25-fold stray light suppression relative to classical imaging. We further introduce wide-field quantum microscopy by coincidence (QMC) using symmetric, balanced paths to achieve Heisenberg-limited super-resolution, with up to 155-fold suppression of stray light and improved speed and contrast-to-noise ratio. Together, QMC and ICE represent significant advances in quantum bioimaging, offering low-light, high-resolution, and noninvasive imaging capabilities with potential impact in life sciences and remote sensing.

Quantum Effects and Measurement Techniques in Biology and Biophotonics•Mar 4, 2026•0 citations
With the advancement of non-classical light sources such as single-photon and entangled-photon sources, innovative microscopy based on quantum principles has been proposed for traditional microscopy. This paper introduces the experimental demonstration of a quantum polarization microscopic technique that incorporates a quantum-entangled photon source. Although the point that employs the variation in polarization angle due to reflection or transmission at the sample is similar to classical polarization microscopy, the method for constructing the image contrast is significantly different. The image contrast is constructed by the coincidence count of signal and idler photons. In the case that the coincidence count is recorded from both the signal and idler photons, the photon statistics resemble a thermal state, similar to the blackbody radiation, but with a significantly higher peak intensity in the second-order autocorrelation function at zero delay that is derived from the coincidence count, while, when the coincidence count is taken from either the signal or idler photon only, although the photon state exhibits a thermal state again, the photon statistics become more dispersive and result in a lower peak intensity of the autocorrelation function. These different thermal states can be switched by slightly changing the photon polarization, which is suddenly aroused within a narrow range of the analyzer angle. The autocorrelation function g2(0) at the thermal state exhibits a sensitivity that is three times higher compared to the classical coincidence count rate, and this concept can be effectively utilized to enhance the contrast of the image. One of the key achievements of our proposed method is ensuring a low power of illumination (in the order of Pico-joules) for constructing the image. In addition, the robustness without any precise setup is also favorable for practical use. This polarization microscopic technique can provide a superior imaging technique compared to the classical method, opening a new frontier for research in material sciences, biology, and other fields requiring high-resolution imaging.
Abstract Quantum imaging is an advanced method for microscopy or investigating the optical properties of materials or bio-medical inspections with high accuracy, low noise, and extremely low photo-damage. In previous work, we proposed a quantum imaging technique, in which variations in polarization angle due to reflection or transmission at the sample enhance image contrast in the second-order autocorrelation function at zero delay g 2(0). However, the image resolution observed was not satisfactory. In this report, to improve the image quality, the parameters such as coincidence window was optimized to distinguish photon statistics effectively due to change in polarization angle and the objective lens was utilized to focus the entangled photon beams. These modifications enabled optical imaging by accurately detecting slight polarization variations in different media. Although this method is effective for various samples, it has certain limitations for samples that exhibit polarization disturbances, such as those involving photon scattering. Nevertheless, the proposed approach demonstrates superior imaging performance under noisy conditions and low illumination, offering promising possibilities for high-quality quantum imaging applications.
Technological advancements in the creation, manipulation and detection of quantum states of light have motivated the application of such states to overcome classical limits in sensing and imaging. In particular, there has been a surge of recent interest in super-resolution imaging based on principles of quantum optics. However, the application of such schemes for practical imaging of biological samples is demanding in terms of signal-to-noise ratio, speed of acquisition and robustness with respect to sample labeling. Here, we re-introduce the concept of quantum image scanning microscopy (Q-ISM), a super-resolution method that enhances the classical image scanning microscopy (ISM) method by measuring photon correlations. Q-ISM was already utilized to achieve super-resolved images of a biological sample labeled with fluorescent nanoscrystals whose contrast is based entirely on a quantum optical phenomenon, photon antibunching. We present here an experimental demonstration of the method and discuss with further details its prospects for application in life science microscopy.
Two-photon interference in a Hong-Ou-Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples.
Polarization entanglement of single photons is a key element to enable quantum 2.0 applications, such as quantum computing, quantum networks, and quantum sensing. Verification and fidelity assessment of the entanglement state are typically performed by sequential coincidence measurements with single-pixel photon detectors. Quantum imaging techniques that use single-photon imaging cameras for visualizing an entangled biphoton state and calculating Bell's inequality have been reported. Their performances are limited for practical use due to low photon flux and low speed. Here, we introduce a new approach to image polarization-entangled biphoton states using radial polarizations, which enables rapid high-performance entanglement measurement. An intensified single-photon counting camera (SPCC) captures a single image with multiple polarizations imposed by a radial wave plate, which converts a linear polarization of single photons to radial polarizations. The coincidence photon image is rapidly taken with the SPCC in the integrate-on-chip mode, which is triggered by the idler photons set at a specific polarization angle. Bell's inequality is calculated directly from four coincidence images that show polarization correlation. Our technique not only visualizes the entangled polarization state but also enables fast full Bell-type evaluation of photonic polarization entanglement. We envision that our approach may be instrumental for developing advanced polarization-entangled photon sources and polarization-entangled quantum systems, which in turn would advance fundamental research involving dynamic photon-matter interactions.
Quantum entanglement has been shown to imply correlations stronger than those allowed by classical models. The possibility of performing tasks that are classically impossible has made quantum entanglement a powerful resource for the development of novel methods and applications in various fields of research such as quantum computing, quantum cryptography, and quantum metrology. There is a great need for the development of next generation instrumentation and technologies utilizing entangled quantum light. Among the many applications of nonclassical states of light, nonlinear microscopy has the potential to make an impact in broad areas of science from physics to biology. Here, the microscopic image created by the fluorescence selectively excited by the process of the entangled two-photon absorption is reported. Entangled two-photon microscopy offers nonlinear imaging capabilities at an unprecedented low excitation intensity 10 7, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. The nonmonotonic dependence of the image on the femtosecond delay between the components of the entangled photon pair is demonstrated. This delay dependence is a result of specific quantum interference effects associated with the entanglement and this is not observable with classical excitation light. In combination with novel spectroscopic capabilities provided by a nonclassical light excitation, this is of critical importance for sensing and biological applications.
Entangled photons enable quantum imaging to surpass classical limits in resolution and noise. To address long-standing challenges in quantum imaging (such as low signal-to-noise, limited resolvable pixels, and difficulty imaging biological samples), we present imaging by coincidence from entanglement (ICE). ICE leverages spatial and polarization entanglement to enhance resolution, support biological imaging, and quantify birefringence properties. Polarization entanglement enables remote, quantitative measurement of both phase retardation and principal axis orientation without changing input polarization. ICE achieves up to 25-fold stray light suppression relative to classical imaging. We further introduce wide-field quantum microscopy by coincidence (QMC) using symmetric, balanced paths to achieve Heisenberg-limited super-resolution, with up to 155-fold suppression of stray light and improved speed and contrast-to-noise ratio. Together, QMC and ICE represent significant advances in quantum bioimaging, offering low-light, high-resolution, and noninvasive imaging capabilities with potential impact in life sciences and remote sensing.