Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2410.04284 · Optical Trapping and Optical Micromanipulation

Quantum fluctuations and noise in interferometry and photodetection: applications in optical sensing and micromanipulation

Masud Mansuripur

Published Oct 2, 2024• 0 citations
arXivHTMLPDF

Abstract

Accurate optical sensing and micromanipulation requires sensitive measurements of the position, orientation, and dynamics of small particles—and sometimes even large objects—under consideration. The signals acquired in the process, including those needed for the feedback control of these particles and objects, are inevitably contaminated by quantum fluctuations and noise that accompany the physical processes of optical interference and photodetection (or photon counting). This paper explores the origins of signal fluctuation and quantum noise that are inevitably associated with such sensitive measurements.

DOI
10.1117/12.3028580

Related papers

Quantum-mechanical noise in an interferometer

Carlton M. Caves

The interferometers now being developed to detect gravitational waves work by measuring the relative positions of widely separated masses. Two fundamental sources of quantum-mechanical noise determine the sensitivity of such an interferometer: (i) fluctuations in number of output photons (photon-counting error) and (ii) fluctuations in radiation pressure on the masses (radiation-pressure error). Because of the low power of available continuous-wave lasers, the sensitivity of currently planned interferometers will be limited by photon-counting error. This paper presents an analysis of the two types of quantum-mechanical noise, and it proposes a new technique---the "squeezed-state" technique---that allows one to decrease the photon-counting error while increasing the radiation-pressure error, or vice versa. The key requirement of the squeezed-state technique is that the state of the light entering the interferometer's normally unused input port must be not the vacuum, as in a standard interferometer, but rather a "squeezed state"---a state whose uncertainties in the two quadrature phases are unequal. Squeezed states can be generated by a variety of nonlinear optical processes, including degenerate parametric amplification.

Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Apr 15, 1981•3,277 citations

Coherent Optical Frequency Transfer over 100 km Fiber Link Using Bidirectional Active Optics

Hanxu Wu, Xiaoming Zhang, Weinan Zhao +7 more

SummaryPrecise and stable coherent optical frequency transfer over long-haul fiber link is required by diverse scientific applications, such as large-scale optical clock networks, global positioning and timing, very-long baseline interferometry, and high-sensitivity tests of fundamental physics. To meet the needs of the above applications, active compensation schemes for cancelling fiber-induced phase noise has developed considerably over the past ten years. However, optical signal severely reduces across distant fiber-optic networks, which degrades optical beat signal and feedback control.Here, we adopt active phase compensation and bidirectional optical frequency locking to achieve ultra-stable optical carrier transfer. The phase noise of the fiber link is effectively suppressed, meanwhile, the ultra-stable optical frequency signal is regenerated accurately at the remote site.Preliminary experiment over 100 km fiber link indicates that the additional frequency stability exhibits 1.9×10-16and 2.5×10-17at an averaging time of 1 s and 100 s, respectively. This approach has a capacity of extending to the parallel transfer of microwave and optical frequency, and free-space optical frequency transfer.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 15, 2023•0 citations

Fluctuations and noise in photonics and quantum optics: a special issue in memory of Hermann Haus

Derek Abbott, Jeffrey H. Shapiro, Y. Yamamoto

This Special Issue of Journal of Optics B: Quantum and Semiclassical Optics brings together the contributions of various researchers working on theoretical and experimental aspects of fluctuational phenomena in photonics and quantum optics. The topics discussed in this issue extend from fundamental physics to applications of noise and fluctuational methods from quantum to classical systems, and include: • Quantum measurement • Quantum squeezing • Solitons and fibres • Gravitational wave inferometers • Fluorescence phenomena • Cavity QED • Photon statistics • Noise in lasers and laser systems • Quantum computing and information • Quantum lithography • Teleportation.

Journal of Optics B Quantum and Semiclassical Optics•Jul 28, 2004•0 citations

The Future: From Q‐demonstrations to Q‐technologies

Hans‐A. Bachor, Timothy C. Ralph

A significant consequence of the quantum nature of light in optical instruments is the presence of quantum noise in optical measurements. This noise limits the range of signals that can be used and signal-to-noise ratios that can be achieved. In addition, the performance of the system is different for very large signals, or modulations, and for small signals close to the quantum noise level. Some of the limitations introduced by quantum noise can be avoided by using non-classical, or squeezed, states of light. Technology has now advanced to the point where fundamental quantum effects such as the fluctuations of the vacuum field and the discreteness of light can be demonstrated in undergraduate teaching laboratories, and there are a growing number of applications for quantum light, in particular in precision metrology and applications ranging from large-scale gravitational-wave detectors to imaging and precision clocks.

Wiley eBooks•Jul 5, 2019•0 citations

Photon-pairing-enhanced distributed spectroscopy sensing over 400 km optical fiber

Jinping Lin, Lai Zhou, Minxue Zhuang +4 more

Single-photon detection enables sensitive measurements at ultra-low photon fluxes, supporting long-range sensing and imaging tasks. Photon-counting schemes reconstruct spectra by coherently accumulating interferograms, but phase fluctuations between interfering beams pose challenges for distributed spectroscopy. Here, we introduce a photon-pairing scheme that exploits second-order correlations rather than relying on first-order interference, thereby removing the need for phase alignment of interferograms while enabling long integration times. Our approach enhances the signal-to-noise ratio (SNR) of reconstructed spectra, with SNR increasing linearly with photon count rate, in contrast to the square-root dependence of photon-counting techniques. We accurately reconstruct intensity spectra at an average receiving power of only 5.5 × 10−15 W per comb line over a 400 km fiber link in a distributed configuration, achieving an SNR of over 23.5 dB and demonstrating strong resilience to fiber-induced fluctuations. Our photon-pairing scheme holds strong potential for long-haul dual-comb spectroscopy and opens new avenues for frequency metrology, remote sensing, and quantum networking. Photon-pairing spectroscopy overcomes phase fluctuations to enable sensitive spectral measurements over 400 km of fibre. The study achieves spectral reconstruction at an ultra-low power of 5.5 × 10-15 W per comb line, advancing long-range sensing.

Nature Communications•Oct 31, 2026•0 citations

SSP-QST: Spectral Subspace Purification for Photonic Quantum State Tomography

Anuvab Sen, Saibal Mukhopadhyay

Photonic quantum sensing often uses low-rank entangled probes such as Greenberger-Horne-Zeilinger (GHZ), Bell, and NOON states. Although these probes are ideally rank-1, practical quantum state tomography (QST) can produce density-matrix estimates with many small finite-shot and noise-induced eigenmodes. This eigenvalue contamination can increase the estimated entropy of the reconstruction and reduce the quantum Fisher information (QFI) available for downstream sensing, while fixed rank-1 purification can discard valid signal modes when real probes acquire additional signal modes. We introduce Spectral Subspace Purification for Quantum State Tomography (SSP-QST), a rank-adaptive post-processing layer for least-squares quantum state tomography (LS-QST). SSP-QST eigendecomposes the least-squares estimate, computes a Weyl-motivated noise floor from the measured spectrum and shot count, removes eigenmodes below this floor, and renormalises the retained subspace. It requires no rank prior, no iterative optimisation, and only one eigendecomposition. In Qiskit Aer simulations, SSP-QST achieves the highest fidelity among the tested non-iterative baselines across the evaluated probe ranks, with a maximum fidelity gain of $+0.584$. It also improves shot efficiency by at least $8\times$ within the tested range. These results show that SSP-QST can make photonic QST more reliable under finite-shot noise while providing a lightweight reconstruction primitive for feedback-oriented quantum sensing pipelines.

quant-pharXiv:2607.21836•Jul 27, 2026•0 citations
Accurate optical sensing and micromanipulation requires sensitive measurements of the position, orientation, and dynamics of small particles—and sometimes even large objects—under consideration. The signals acquired in the process, including those needed for the feedback control of these particles and objects, are inevitably contaminated by quantum fluctuations and noise that accompany the physical processes of optical interference and photodetection (or photon counting). This paper explores the origins of signal fluctuation and quantum noise that are inevitably associated with such sensitive measurements.
The interferometers now being developed to detect gravitational waves work by measuring the relative positions of widely separated masses. Two fundamental sources of quantum-mechanical noise determine the sensitivity of such an interferometer: (i) fluctuations in number of output photons (photon-counting error) and (ii) fluctuations in radiation pressure on the masses (radiation-pressure error). Because of the low power of available continuous-wave lasers, the sensitivity of currently planned interferometers will be limited by photon-counting error. This paper presents an analysis of the two types of quantum-mechanical noise, and it proposes a new technique---the "squeezed-state" technique---that allows one to decrease the photon-counting error while increasing the radiation-pressure error, or vice versa. The key requirement of the squeezed-state technique is that the state of the light entering the interferometer's normally unused input port must be not the vacuum, as in a standard interferometer, but rather a "squeezed state"---a state whose uncertainties in the two quadrature phases are unequal. Squeezed states can be generated by a variety of nonlinear optical processes, including degenerate parametric amplification.
SummaryPrecise and stable coherent optical frequency transfer over long-haul fiber link is required by diverse scientific applications, such as large-scale optical clock networks, global positioning and timing, very-long baseline interferometry, and high-sensitivity tests of fundamental physics. To meet the needs of the above applications, active compensation schemes for cancelling fiber-induced phase noise has developed considerably over the past ten years. However, optical signal severely reduces across distant fiber-optic networks, which degrades optical beat signal and feedback control.Here, we adopt active phase compensation and bidirectional optical frequency locking to achieve ultra-stable optical carrier transfer. The phase noise of the fiber link is effectively suppressed, meanwhile, the ultra-stable optical frequency signal is regenerated accurately at the remote site.Preliminary experiment over 100 km fiber link indicates that the additional frequency stability exhibits 1.9×10-16and 2.5×10-17at an averaging time of 1 s and 100 s, respectively. This approach has a capacity of extending to the parallel transfer of microwave and optical frequency, and free-space optical frequency transfer.
This Special Issue of Journal of Optics B: Quantum and Semiclassical Optics brings together the contributions of various researchers working on theoretical and experimental aspects of fluctuational phenomena in photonics and quantum optics. The topics discussed in this issue extend from fundamental physics to applications of noise and fluctuational methods from quantum to classical systems, and include: • Quantum measurement • Quantum squeezing • Solitons and fibres • Gravitational wave inferometers • Fluorescence phenomena • Cavity QED • Photon statistics • Noise in lasers and laser systems • Quantum computing and information • Quantum lithography • Teleportation.
A significant consequence of the quantum nature of light in optical instruments is the presence of quantum noise in optical measurements. This noise limits the range of signals that can be used and signal-to-noise ratios that can be achieved. In addition, the performance of the system is different for very large signals, or modulations, and for small signals close to the quantum noise level. Some of the limitations introduced by quantum noise can be avoided by using non-classical, or squeezed, states of light. Technology has now advanced to the point where fundamental quantum effects such as the fluctuations of the vacuum field and the discreteness of light can be demonstrated in undergraduate teaching laboratories, and there are a growing number of applications for quantum light, in particular in precision metrology and applications ranging from large-scale gravitational-wave detectors to imaging and precision clocks.
Single-photon detection enables sensitive measurements at ultra-low photon fluxes, supporting long-range sensing and imaging tasks. Photon-counting schemes reconstruct spectra by coherently accumulating interferograms, but phase fluctuations between interfering beams pose challenges for distributed spectroscopy. Here, we introduce a photon-pairing scheme that exploits second-order correlations rather than relying on first-order interference, thereby removing the need for phase alignment of interferograms while enabling long integration times. Our approach enhances the signal-to-noise ratio (SNR) of reconstructed spectra, with SNR increasing linearly with photon count rate, in contrast to the square-root dependence of photon-counting techniques. We accurately reconstruct intensity spectra at an average receiving power of only 5.5 × 10−15 W per comb line over a 400 km fiber link in a distributed configuration, achieving an SNR of over 23.5 dB and demonstrating strong resilience to fiber-induced fluctuations. Our photon-pairing scheme holds strong potential for long-haul dual-comb spectroscopy and opens new avenues for frequency metrology, remote sensing, and quantum networking. Photon-pairing spectroscopy overcomes phase fluctuations to enable sensitive spectral measurements over 400 km of fibre. The study achieves spectral reconstruction at an ultra-low power of 5.5 × 10-15 W per comb line, advancing long-range sensing.
Photonic quantum sensing often uses low-rank entangled probes such as Greenberger-Horne-Zeilinger (GHZ), Bell, and NOON states. Although these probes are ideally rank-1, practical quantum state tomography (QST) can produce density-matrix estimates with many small finite-shot and noise-induced eigenmodes. This eigenvalue contamination can increase the estimated entropy of the reconstruction and reduce the quantum Fisher information (QFI) available for downstream sensing, while fixed rank-1 purification can discard valid signal modes when real probes acquire additional signal modes. We introduce Spectral Subspace Purification for Quantum State Tomography (SSP-QST), a rank-adaptive post-processing layer for least-squares quantum state tomography (LS-QST). SSP-QST eigendecomposes the least-squares estimate, computes a Weyl-motivated noise floor from the measured spectrum and shot count, removes eigenmodes below this floor, and renormalises the retained subspace. It requires no rank prior, no iterative optimisation, and only one eigendecomposition. In Qiskit Aer simulations, SSP-QST achieves the highest fidelity among the tested non-iterative baselines across the evaluated probe ranks, with a maximum fidelity gain of +0.584+0.584+0.584. It also improves shot efficiency by at least 8×8\times8× within the tested range. These results show that SSP-QST can make photonic QST more reliable under finite-shot noise while providing a lightweight reconstruction primitive for feedback-oriented quantum sensing pipelines.