Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2406.19178 · Physical Review Applied

Optimizing longitudinal spin relaxation in miniaturized optically pumped magnetometers

A. McWilliam, S. Dyer, Dominic Hunter, Marcin S. Mrozowski, Stuart J. Ingleby, O. Sharp, David P. Burt, Paul F. Griffin, J. P. McGilligan, Erling Riis

Published Dec 5, 2024• 9 citations
arXivHTMLPDF

Abstract

The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micropill dispenser. We characterize the variation in the intrinsic longitudinal relaxation rate, γ 10 , and magnetic sensitivity, as a function of the resulting nitrogen buffer gas pressure. Measurements are conducted by employing an optically pumped magnetometer operating in a free-induction-decay configuration. γ 10 is extracted across a range of nitrogen pressures between 60 and 700 torr, measuring a minimum of 140 Hz at 115 torr. In addition, we achieve sensitivities as low as 130 fT / Hz at a bias field amplitude of about 50 μ T . With the optimal nitrogen buffer gas pressure now quantified and achievable post-fabrication, these mass-producible cells can be tailored to suit a variety of sensing applications, ensuring peak magnetometer performance. Published by the American Physical Society 2024

DOI
10.1103/physrevapplied.22.064024

Related papers

Buffer Gas Pressure Optimization for Atomic Spin Relaxation Suppression in Ultra-High-Sensitivity SERF Magnetometers

Siran Li, X.-G. Lu, Yinghui Zhang +3 more

Optically pumped magnetometers (OPM) are core quantum payloads for geomagnetic remote sensing. Among them, the spin-exchange relaxation-free (SERF) OPM with aT-level ultimate sensitivity stands as mainstream. While enlarging the alkali-metal vapor cell of the SERF OPM enhances sensitivity, it triggers complex atomic spin relaxation, notably intensified magnetic field gradient relaxation. To address the dilemma of atomic spin relaxation regulation and the engineering requirements of ultra-high-sensitivity SERF magnetometers, this paper constructs an analytical model of the total relaxation rate that comprehensively considers wall-collision relaxation, spin-destruction collision relaxation, and longitudinal/transverse magnetic field gradient relaxation, etc. The analytical relationship between buffer gas pressure and total relaxation rate for a commonly used spherical vapor cell is derived, revealing the intrinsic correlation among cell size, atomic spin relaxation, and optimal pressure. Based on the theoretical model, the filling parameters of the vapor cell are optimized, and experimental measurements are carried out. The theoretical relaxation results are highly consistent with the experimental ones, realizing the precise optimization of buffer gas pressure. The optimization method proposed in this paper provides a theoretical basis and parameter guidance for the engineering preparation of alkali-metal vapor cells for high-sensitivity SERF magnetometers in remote sensing applications.

Photonics•Jun 1, 2026•0 citations

Probe-assisted depopulation pumping in low-pressure alkali-metal vapor cells for magnetometry

Mark E. Limes, J. Smoot, J. Perez +4 more

For precision atomic magnetometry, inert buffer gas is included in alkali-metal vapor cells to significantly broaden hyperfine transitions, which facilitates optical pumping and reduces diffusive relaxation, while also providing non-radiative excited state quenching. We show low-buffer gas pressure (below 50 Torr) alkali vapor cells with resolved hyperfine manifolds can also yield high-performance magnetometers. For high polarization in $^{87}$Rb, we optically pump $F=2$ states with narrow linewidth $σ_+$ light, while tuning a probe beam to depopulate $F=1$ states ($Δν= 6.8$ GHz from $F=2$). The probe tuning then also provides $F=2$ detection with high optical rotation and low probe broadening; we demonstrate top-bottom gradiometry, within a single 25 Torr, 0.5 cc cell, that yields an Earth's field free-precession magnetometer sensitivity of 18 fT/$\sqrt{\text{Hz}}$ with a 1 kHz bandwidth, as well as RF magnetometer sensitivity of 12 fT/$\sqrt{\text{Hz}}$ in a small band about 110 kHz.

arXiv:2602.10931•Physical Review A•Feb 9, 2026•0 citations

Collaborative Suppression of Spin Relaxation by Inner-Wall Coating and Buffer Gas in Millimeter-Scale Cells for Miniaturized SERF Magnetometers

Bowen Liu, Xiangyang Zhou, Zhen Li +3 more

Ultrahigh sensitivity is essential for magnetometers used to detect extremely weak human magnetic fields in applications such as magnetoencephalography (MEG) and magnetocardiography (MCG), where device miniaturization is required to achieve high spatial resolution. Among ultraweak magnetic-field sensing technologies, spin-exchange relaxation-free (SERF) magnetometers offer the highest sensitivity, but their performance is strongly influenced by spin relaxation within the alkali-metal vapor cell. In millimeter-scale cells, the optimal buffer-gas pressure for suppressing spin relaxation usually lies in a relatively high-pressure regime, which causes pressure broadening, weakens light–atom interaction, and ultimately limits magnetometer performance. In this article, a collaborative method combining an inner-wall antirelaxation coating with buffer gas is proposed to suppress spin relaxation and optimize SERF magnetometer performance. The coating reduces depolarization during atom–wall collisions, while the buffer gas suppresses atomic diffusion to the wall. Their combined effect not only suppresses spin relaxation but also lowers the optimal buffer-gas pressure. Experiments using 4-mm cubic nitrogen-buffer-gas vapor cells, including coated and uncoated cells, show that the coating shifts the optimal pressure from approximately 1100 Torr for the uncoated cell to 700 Torr for the coated cell. The averaged sensitivity over the 10–100-Hz band is$13.82~\mathrm {fT}/\mathrm {Hz}^{1/2}$for the 700 Torr coated cell, comparable to$14.61~\mathrm {fT}/\mathrm {Hz}^{1/2}$for the 1100 Torr uncoated cell. These results provide a practical route toward high-performance miniaturized SERF magnetometers at reduced operating pressure and with reduced pump-power demand.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

A Compact Single-Beam Optically Pumped Magnetometer Based on Absorption Detection

Jia-You Liou, Yi‐Hsuan Chen, Hsiang-An Chuang +5 more

We demonstrate a compact single-beam optically pumped magnetometer (OPM) employing a pure 87Rb microfabricated vapor cell with 500 Torr buffer gas. The residual magnetic field is actively minimized to below 400 pT through a combination of mu-metal magnetic shielding and internal compensation coils. We systematically characterize the OPM response as a function of laser detuning and optical intensity, and derive the magnetic-field sensitivity from the signal slope and noise amplitude spectral density. A best sensitivity of 11 fT/Hz^1/2 is achieved near the resonance transition at an optimal optical intensity, using a small cell volume of only 0.027 cm^3. Furthermore, a miniaturized OPM prototype was developed using a folded flexible printed circuit board (FPCB) to integrate the vapor cell, a compact heater, and magnetic-field coils into a cubic sensing head. Two coil configurations patterned directly on the FPCB were investigated. Under optimized operating conditions, the OPM prototype achieved a sensitivity of 66 fT/Hz^1/2. These results demonstrate that high-buffer-pressure single-beam OPMs can achieve excellent sensitivity, establishing a pathway toward compact and scalable arrays.

arXiv:2610.32795•Oct 23, 2026•0 citations

Free-induction-decay magnetic field imaging with a microfabricated Cs vapor cell

Dominic Hunter, Christopher Perrella, Allan McWilliam +7 more

Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusion of Cs atoms in the presence of a nitrogen (N 2 ) buffer gas enables spatially independent measurements to be made within the same vapor cell by translating a 175 μ m diameter probe beam over the sensing area. For example, the OPM was used to record temporal and spatial information to reconstruct magnetic field distributions in one and two dimensions. The optimal magnetometer sensitivity was estimated to be 0.43 pT/Hz within a Nyquist limited bandwidth of 500 Hz. Furthermore, the sensor’s dynamic range exceeds the Earth’s field of approximately 50 μ T, which provides a framework for magnetic field imaging in unshielded environments.

arXiv:2303.10915•Optics Express•Sep 11, 2023•19 citations

Influence of Buffer-Gas Pressure Inside Micro Alkali Vapor Cells on the Performance of Chip-Scale SERF Magnetometers

Lei Wu, Jintang Shang, Yu Ji +2 more

Spin-exchange-relaxation-free (SERF) optical atomic magnetometers are facing the challenges of dramatic decrease of sensitivity when the alkali vapor cells become small. This paper focuses on the sensitivity improvement of the chip-scale atomic magnetometer (CSAM) by changing buffer-gas pressures inside the microfabricated vapor cells. The rubidium vapor cells with three different buffer-gas pressures were tested in the SERF magnetometer. The influences of vapor cell temperature and pumping laser power on the device sensitivity are also characterized for further optimization. Results show that the three atomic vapor cells, with N2buffer-gas pressure of 0.20, 0.88, and 2.35 amg, have sensitivities of 900, 500, and 150 fT/Hz1/2, respectively. Results indicated that when the alkali vapor cells continue to be smaller, high buffer-gas pressure would provide an effective way to reduce the wall collision and improve the performance of CSAMs.

IEEE Transactions on Components Packaging and Manufacturing Technology•Dec 21, 2017•18 citations
The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micropill dispenser. We characterize the variation in the intrinsic longitudinal relaxation rate, γ 10 , and magnetic sensitivity, as a function of the resulting nitrogen buffer gas pressure. Measurements are conducted by employing an optically pumped magnetometer operating in a free-induction-decay configuration. γ 10 is extracted across a range of nitrogen pressures between 60 and 700 torr, measuring a minimum of 140 Hz at 115 torr. In addition, we achieve sensitivities as low as 130 fT / Hz at a bias field amplitude of about 50 μ T . With the optimal nitrogen buffer gas pressure now quantified and achievable post-fabrication, these mass-producible cells can be tailored to suit a variety of sensing applications, ensuring peak magnetometer performance. Published by the American Physical Society 2024
Optically pumped magnetometers (OPM) are core quantum payloads for geomagnetic remote sensing. Among them, the spin-exchange relaxation-free (SERF) OPM with aT-level ultimate sensitivity stands as mainstream. While enlarging the alkali-metal vapor cell of the SERF OPM enhances sensitivity, it triggers complex atomic spin relaxation, notably intensified magnetic field gradient relaxation. To address the dilemma of atomic spin relaxation regulation and the engineering requirements of ultra-high-sensitivity SERF magnetometers, this paper constructs an analytical model of the total relaxation rate that comprehensively considers wall-collision relaxation, spin-destruction collision relaxation, and longitudinal/transverse magnetic field gradient relaxation, etc. The analytical relationship between buffer gas pressure and total relaxation rate for a commonly used spherical vapor cell is derived, revealing the intrinsic correlation among cell size, atomic spin relaxation, and optimal pressure. Based on the theoretical model, the filling parameters of the vapor cell are optimized, and experimental measurements are carried out. The theoretical relaxation results are highly consistent with the experimental ones, realizing the precise optimization of buffer gas pressure. The optimization method proposed in this paper provides a theoretical basis and parameter guidance for the engineering preparation of alkali-metal vapor cells for high-sensitivity SERF magnetometers in remote sensing applications.
For precision atomic magnetometry, inert buffer gas is included in alkali-metal vapor cells to significantly broaden hyperfine transitions, which facilitates optical pumping and reduces diffusive relaxation, while also providing non-radiative excited state quenching. We show low-buffer gas pressure (below 50 Torr) alkali vapor cells with resolved hyperfine manifolds can also yield high-performance magnetometers. For high polarization in 87^{87}87Rb, we optically pump F=2F=2F=2 states with narrow linewidth σ+σ_+σ+​ light, while tuning a probe beam to depopulate F=1F=1F=1 states (Δν=6.8Δν= 6.8Δν=6.8 GHz from F=2F=2F=2). The probe tuning then also provides F=2F=2F=2 detection with high optical rotation and low probe broadening; we demonstrate top-bottom gradiometry, within a single 25 Torr, 0.5 cc cell, that yields an Earth's field free-precession magnetometer sensitivity of 18 fT/Hz\sqrt{\text{Hz}}Hz​ with a 1 kHz bandwidth, as well as RF magnetometer sensitivity of 12 fT/Hz\sqrt{\text{Hz}}Hz​ in a small band about 110 kHz.
Ultrahigh sensitivity is essential for magnetometers used to detect extremely weak human magnetic fields in applications such as magnetoencephalography (MEG) and magnetocardiography (MCG), where device miniaturization is required to achieve high spatial resolution. Among ultraweak magnetic-field sensing technologies, spin-exchange relaxation-free (SERF) magnetometers offer the highest sensitivity, but their performance is strongly influenced by spin relaxation within the alkali-metal vapor cell. In millimeter-scale cells, the optimal buffer-gas pressure for suppressing spin relaxation usually lies in a relatively high-pressure regime, which causes pressure broadening, weakens light–atom interaction, and ultimately limits magnetometer performance. In this article, a collaborative method combining an inner-wall antirelaxation coating with buffer gas is proposed to suppress spin relaxation and optimize SERF magnetometer performance. The coating reduces depolarization during atom–wall collisions, while the buffer gas suppresses atomic diffusion to the wall. Their combined effect not only suppresses spin relaxation but also lowers the optimal buffer-gas pressure. Experiments using 4-mm cubic nitrogen-buffer-gas vapor cells, including coated and uncoated cells, show that the coating shifts the optimal pressure from approximately 1100 Torr for the uncoated cell to 700 Torr for the coated cell. The averaged sensitivity over the 10–100-Hz band is13.82 fT/Hz1/213.82~\mathrm {fT}/\mathrm {Hz}^{1/2}13.82 fT/Hz1/2for the 700 Torr coated cell, comparable to14.61 fT/Hz1/214.61~\mathrm {fT}/\mathrm {Hz}^{1/2}14.61 fT/Hz1/2for the 1100 Torr uncoated cell. These results provide a practical route toward high-performance miniaturized SERF magnetometers at reduced operating pressure and with reduced pump-power demand.
We demonstrate a compact single-beam optically pumped magnetometer (OPM) employing a pure 87Rb microfabricated vapor cell with 500 Torr buffer gas. The residual magnetic field is actively minimized to below 400 pT through a combination of mu-metal magnetic shielding and internal compensation coils. We systematically characterize the OPM response as a function of laser detuning and optical intensity, and derive the magnetic-field sensitivity from the signal slope and noise amplitude spectral density. A best sensitivity of 11 fT/Hz^1/2 is achieved near the resonance transition at an optimal optical intensity, using a small cell volume of only 0.027 cm^3. Furthermore, a miniaturized OPM prototype was developed using a folded flexible printed circuit board (FPCB) to integrate the vapor cell, a compact heater, and magnetic-field coils into a cubic sensing head. Two coil configurations patterned directly on the FPCB were investigated. Under optimized operating conditions, the OPM prototype achieved a sensitivity of 66 fT/Hz^1/2. These results demonstrate that high-buffer-pressure single-beam OPMs can achieve excellent sensitivity, establishing a pathway toward compact and scalable arrays.
Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusion of Cs atoms in the presence of a nitrogen (N 2 ) buffer gas enables spatially independent measurements to be made within the same vapor cell by translating a 175 μ m diameter probe beam over the sensing area. For example, the OPM was used to record temporal and spatial information to reconstruct magnetic field distributions in one and two dimensions. The optimal magnetometer sensitivity was estimated to be 0.43 pT/Hz within a Nyquist limited bandwidth of 500 Hz. Furthermore, the sensor’s dynamic range exceeds the Earth’s field of approximately 50 μ T, which provides a framework for magnetic field imaging in unshielded environments.
Spin-exchange-relaxation-free (SERF) optical atomic magnetometers are facing the challenges of dramatic decrease of sensitivity when the alkali vapor cells become small. This paper focuses on the sensitivity improvement of the chip-scale atomic magnetometer (CSAM) by changing buffer-gas pressures inside the microfabricated vapor cells. The rubidium vapor cells with three different buffer-gas pressures were tested in the SERF magnetometer. The influences of vapor cell temperature and pumping laser power on the device sensitivity are also characterized for further optimization. Results show that the three atomic vapor cells, with N2buffer-gas pressure of 0.20, 0.88, and 2.35 amg, have sensitivities of 900, 500, and 150 fT/Hz1/2, respectively. Results indicated that when the alkali vapor cells continue to be smaller, high buffer-gas pressure would provide an effective way to reduce the wall collision and improve the performance of CSAMs.