arXiv:2303.07018 · Physical Review Applied

Readout of quantum devices with a sideband microwave interferometer immune to systematic noise

N. Crescini, Eoin G. Kelly, Gian Salis, Andreas Fuhrer

Published Oct 27, 2023• 0 citations
arXivHTMLPDF

Abstract

The accuracy of microwave measurements is not only critical for applications in telecommunication and radar but also for future quantum computers. Qubit technologies such as superconducting qubits or spin qubits require the detection of minuscule signals, typically achieved by reflecting a microwave tone off a resonator that is coupled to the qubit. Noise from cabling and amplification, e.g., from temperature variations, can be detrimental to readout fidelity. We present an approach to detect phase and amplitude changes of a device under test based on the differential measurement of microwave tones generated by two first-order sidebands of a carrier signal. The two microwave tones are sent through the same cable to the measured device that exhibits a narrow-band response for one sideband and leaves the other unaffected. The reflected sidebands are interfered by down-conversion with the carrier. By choosing the amplitude and phases of the sidebands, suppression of either common-amplitude or common-phase noise can be achieved, allowing for fast, stable measurements of frequency shifts and quality factors of resonators. Test measurements were performed on $\mathrm{NbN}$ superconducting resonators at 25 mK to calibrate and characterize the experimental setup and to study time-dependent fluctuations of their resonance frequency.

DOI
10.1103/physrevapplied.20.044072

Related papers

Single-sideband modulator for frequency domain multiplexing of superconducting qubit readout

Benjamin J. Chapman, Eric I. Rosenthal, Joseph Kerckhoff +3 more

We introduce and experimentally characterize a superconducting single-sideband modulator compatible with cryogenic microwave circuits and propose its use for frequency domain multiplexing of superconducting qubit readout. The monolithic double-balanced modulators that comprise the device are formed with purely reactive elements (capacitors and Josephson junction inductors) and require no microwave-frequency control tones. Microwave signals in the 4 to 8 GHz band, with power up to −85 dBm, are converted up or down in frequency by as much as 120 MHz. Spurious harmonics in the device can be suppressed by up to 25 dB for select probe and modulation frequencies.

arXiv:1703.01693•Applied Physics Letters•Apr 17, 2017•15 citations

Frequency Up-Conversion Schemes for Controlling Superconducting Qubits

J. Herrmann, Christoph Hellings, Stefania Lazar +8 more

High-fidelity control of superconducting qubits requires the generation of microwave-frequency pulses precisely tailored on nanosecond timescales. These pulses are most commonly synthesized by up-converting and superimposing two narrow-band intermediate-frequency signals referred to as the in-phase (I) and quadrature (Q) components. While the calibration of their DC-offsets, relative amplitude and phase allows one to cancel unwanted sideband and carrier leakage, this IQ mixing approach suffers from the presence of additional spurious frequency components. Here, we experimentally study an alternative approach based on double frequency conversion, which overcomes this challenge and circumvents the need for IQ-calibration. We find a spurious-free dynamic range of more than 70$\,$dB and compare the quality of pulse generation against a state-of-the-art IQ mixing scheme by performing repeated single-qubit randomized benchmarking on a superconducting qubit.

arXiv:2210.02513•Oct 5, 2022•14 citations

Superconducting Qubit Network as a Single Microwave Photon Detector for Galactic Axion Search

Emanuele Enrico, C. Bonavolontà, G. Brida +13 more

Experimental search of galactic axions requires detection of single photons in the microwave range. We work on a novel approach to detect single microwave photons based on a coherent collective response of quantum states occurring in a superconducting qubit network (SQN) embedded in a lowdissipative superconducting resonator. We propose a two resonators detector configuration with two parallel resonators without common part and with separated input and output terminals. The device consists of a low-dissipative resonator with embedded SQN in which microwave photons arrive (“signal resonator”), and a transmission line for measuring the frequency dependent transmission coefficient demonstrating resonant drops at the qubit frequencies (“readout resonator”). In comparison with T-type three terminal device recently proposed and investigated by us, the device with two resonators with separated input and output terminals doesn't contain common part of both resonators and exclude an unwanted noise from measurement readout circuits to the signal resonator. A layout of two resonators four terminal SQN detectors containing 5 flux qubits weakly coupled to a low-dissipative signal and readout resonator was developed and optimized. The samples were fabricated by Manhattan Al-based technology with Nb resonator circuits. The SQN detector was experimentally tested in terms of microwave measurements of scattering parameters of both resonators, and crosstalk properties. Comparison of experimental data with results of the simulations permits one to conclude that the electromagnetic conditions of the fundamental resonant peak of 8.5 GHz of both resonators aren't affected by the crosstalk phenomenon and their performances provided by the design remain not altered for correct device operation

IEEE Transactions on Applied Superconductivity•Dec 8, 2023•1 citation

Fast Microwave-free State Preparation and Measurement of Superconducting Qubits

R. Abraham, F. Amet, P. Anderson +212 more

Fast, high-fidelity, scalable state preparation and measurement is critical to the realization of a quantum computing system. The state-of-the-art methods for preparation and readout of superconducting qubits require finely tuned microwave signals and ~100 ns of measurement time, which are major obstacles to the scalability and performance of superconducting quantum computers. Here, we have demonstrated novel, microwave-free methods for both preparation and readout of superconducting qubits with >99% fidelity in only 10 ns for either operation while maintaining qubit coherence. This technology is compatible with scalable superconducting digital control systems, and using quantum flux parametrons for amplification, we demonstrated full quantum-to-digital conversion in only 15 ns, which is an order of magnitude faster than state-of-the-art microwave-based techniques.

quant-pharXiv:2609.01334•Sep 2, 2026•0 citations

Microwave readout scheme for a Josephson phase qubit

Tobias Wirth, Jürgen Lisenfeld, Alexander V. Lukashenko +1 more

We present experimental results on a microwave scheme for reading out a Josephson phase qubit. A capacitively shunted superconducting quantum interference device (SQUID) is used as a nonlinear resonator which is inductively coupled to the qubit. The flux state of the qubit is detected by measuring the amplitude and phase of a microwave pulse reflected from the SQUID resonator. By this low-dissipative method, the qubit state measurement time is reduced to 25 μs, which is much faster than the conventional readout performed by switching the SQUID to its nonzero dc voltage state. The readout scheme presented here allows for reading out multiple qubits using a single microwave line by employing frequency-division multiplexing.

arXiv:1010.0954•Applied Physics Letters•Dec 27, 2010•14 citations

System characterization of dispersive readout in superconducting qubits

D. Sank, Alex Opremcak, Andreas Bengtsson +4 more

Designing quantum systems with the measurement speed and accuracy needed for quantum error correction using superconducting qubits requires iterative design and testing informed by accurate models and characterization tools. We introduce a single protocol, with few prerequisite calibrations, to measure the dispersive shift, resonator linewidth, and drive power used in the dispersive readout of superconducting qubits. We find that the resonator linewidth is poorly controlled, with a factor of 2 variation between the maximum and minimum measured values, and this variation is likely to require focused attention in future quantum error correction experiments. We also introduce a protocol for measuring the efficiency of the readout system using the same power levels as are used in typical qubit readout, and without the need to measure the qubit dephasing. We routinely run these protocols on chips with tens of qubits to a hundred qubits, driven by automation software with little human interaction. Using the extracted system parameters, we find that a model based on these parameters predicts the readout signal-to-noise ratio to within 10% over a device with 54 qubits.

arXiv:2402.00413•Physical Review Applied•Feb 21, 2025•25 citations
The accuracy of microwave measurements is not only critical for applications in telecommunication and radar but also for future quantum computers. Qubit technologies such as superconducting qubits or spin qubits require the detection of minuscule signals, typically achieved by reflecting a microwave tone off a resonator that is coupled to the qubit. Noise from cabling and amplification, e.g., from temperature variations, can be detrimental to readout fidelity. We present an approach to detect phase and amplitude changes of a device under test based on the differential measurement of microwave tones generated by two first-order sidebands of a carrier signal. The two microwave tones are sent through the same cable to the measured device that exhibits a narrow-band response for one sideband and leaves the other unaffected. The reflected sidebands are interfered by down-conversion with the carrier. By choosing the amplitude and phases of the sidebands, suppression of either common-amplitude or common-phase noise can be achieved, allowing for fast, stable measurements of frequency shifts and quality factors of resonators. Test measurements were performed on NbN\mathrm{NbN}NbN superconducting resonators at 25 mK to calibrate and characterize the experimental setup and to study time-dependent fluctuations of their resonance frequency.
We introduce and experimentally characterize a superconducting single-sideband modulator compatible with cryogenic microwave circuits and propose its use for frequency domain multiplexing of superconducting qubit readout. The monolithic double-balanced modulators that comprise the device are formed with purely reactive elements (capacitors and Josephson junction inductors) and require no microwave-frequency control tones. Microwave signals in the 4 to 8 GHz band, with power up to −85 dBm, are converted up or down in frequency by as much as 120 MHz. Spurious harmonics in the device can be suppressed by up to 25 dB for select probe and modulation frequencies.
High-fidelity control of superconducting qubits requires the generation of microwave-frequency pulses precisely tailored on nanosecond timescales. These pulses are most commonly synthesized by up-converting and superimposing two narrow-band intermediate-frequency signals referred to as the in-phase (I) and quadrature (Q) components. While the calibration of their DC-offsets, relative amplitude and phase allows one to cancel unwanted sideband and carrier leakage, this IQ mixing approach suffers from the presence of additional spurious frequency components. Here, we experimentally study an alternative approach based on double frequency conversion, which overcomes this challenge and circumvents the need for IQ-calibration. We find a spurious-free dynamic range of more than 70 \,dB and compare the quality of pulse generation against a state-of-the-art IQ mixing scheme by performing repeated single-qubit randomized benchmarking on a superconducting qubit.
Experimental search of galactic axions requires detection of single photons in the microwave range. We work on a novel approach to detect single microwave photons based on a coherent collective response of quantum states occurring in a superconducting qubit network (SQN) embedded in a lowdissipative superconducting resonator. We propose a two resonators detector configuration with two parallel resonators without common part and with separated input and output terminals. The device consists of a low-dissipative resonator with embedded SQN in which microwave photons arrive (“signal resonator”), and a transmission line for measuring the frequency dependent transmission coefficient demonstrating resonant drops at the qubit frequencies (“readout resonator”). In comparison with T-type three terminal device recently proposed and investigated by us, the device with two resonators with separated input and output terminals doesn't contain common part of both resonators and exclude an unwanted noise from measurement readout circuits to the signal resonator. A layout of two resonators four terminal SQN detectors containing 5 flux qubits weakly coupled to a low-dissipative signal and readout resonator was developed and optimized. The samples were fabricated by Manhattan Al-based technology with Nb resonator circuits. The SQN detector was experimentally tested in terms of microwave measurements of scattering parameters of both resonators, and crosstalk properties. Comparison of experimental data with results of the simulations permits one to conclude that the electromagnetic conditions of the fundamental resonant peak of 8.5 GHz of both resonators aren't affected by the crosstalk phenomenon and their performances provided by the design remain not altered for correct device operation
Fast, high-fidelity, scalable state preparation and measurement is critical to the realization of a quantum computing system. The state-of-the-art methods for preparation and readout of superconducting qubits require finely tuned microwave signals and ~100 ns of measurement time, which are major obstacles to the scalability and performance of superconducting quantum computers. Here, we have demonstrated novel, microwave-free methods for both preparation and readout of superconducting qubits with >99% fidelity in only 10 ns for either operation while maintaining qubit coherence. This technology is compatible with scalable superconducting digital control systems, and using quantum flux parametrons for amplification, we demonstrated full quantum-to-digital conversion in only 15 ns, which is an order of magnitude faster than state-of-the-art microwave-based techniques.
We present experimental results on a microwave scheme for reading out a Josephson phase qubit. A capacitively shunted superconducting quantum interference device (SQUID) is used as a nonlinear resonator which is inductively coupled to the qubit. The flux state of the qubit is detected by measuring the amplitude and phase of a microwave pulse reflected from the SQUID resonator. By this low-dissipative method, the qubit state measurement time is reduced to 25 μs, which is much faster than the conventional readout performed by switching the SQUID to its nonzero dc voltage state. The readout scheme presented here allows for reading out multiple qubits using a single microwave line by employing frequency-division multiplexing.
Designing quantum systems with the measurement speed and accuracy needed for quantum error correction using superconducting qubits requires iterative design and testing informed by accurate models and characterization tools. We introduce a single protocol, with few prerequisite calibrations, to measure the dispersive shift, resonator linewidth, and drive power used in the dispersive readout of superconducting qubits. We find that the resonator linewidth is poorly controlled, with a factor of 2 variation between the maximum and minimum measured values, and this variation is likely to require focused attention in future quantum error correction experiments. We also introduce a protocol for measuring the efficiency of the readout system using the same power levels as are used in typical qubit readout, and without the need to measure the qubit dephasing. We routinely run these protocols on chips with tens of qubits to a hundred qubits, driven by automation software with little human interaction. Using the extracted system parameters, we find that a model based on these parameters predicts the readout signal-to-noise ratio to within 10% over a device with 54 qubits.