We report on an evaluation of an optical clock that uses the ^{2}S_{1/2}→^{2}D_{5/2} transition of a single ^{88}Sr^{+} ion as the reference. In contrast to previous work, we estimate the effective temperature of the blackbody radiation that shifts the reference transition directly during operation from the corresponding frequency shift and the well-characterized sensitivity to thermal radiation. We measure the clock output frequency against an independent ^{171}Yb^{+} ion clock, based on the ^{2}S_{1/2}(F=0)→^{2}F_{7/2}(F=3) electric octupole (E3) transition, and determine the frequency ratio with a total fractional uncertainty of 2.3×10^{-17}. Relying on a previous measurement of the ^{171}Yb^{+} (E3) clock frequency, we find the absolute frequency of the ^{88}Sr^{+} clock transition to be 444 779 044 095 485.277(59) Hz. Our result reduces the uncertainty by a factor of 3 compared with the previously most accurate measurement and may help to resolve so far inconsistent determinations of this value. We also show that for three simultaneously interrogated ^{88}Sr^{+} ions, the increased number causes the expected improvement of the short-term frequency instability of the optical clock without degrading its systematic uncertainty.
We report on an evaluation of an optical clock that uses the ^{2}S_{1/2}→^{2}D_{5/2} transition of a single ^{88}Sr^{+} ion as the reference. In contrast to previous work, we estimate the effective temperature of the blackbody radiation that shifts the reference transition directly during operation from the corresponding frequency shift and the well-characterized sensitivity to thermal radiation. We measure the clock output frequency against an independent ^{171}Yb^{+} ion clock, based on the ^{2}S_{1/2}(F=0)→^{2}F_{7/2}(F=3) electric octupole (E3) transition, and determine the frequency ratio with a total fractional uncertainty of 2.3×10^{-17}. Relying on a previous measurement of the ^{171}Yb^{+} (E3) clock frequency, we find the absolute frequency of the ^{88}Sr^{+} clock transition to be 444 779 044 095 485.277(59) Hz. Our result reduces the uncertainty by a factor of 3 compared with the previously most accurate measurement and may help to resolve so far inconsistent determinations of this value. We also show that for three simultaneously interrogated ^{88}Sr^{+} ions, the increased number causes the expected improvement of the short-term frequency instability of the optical clock without degrading its systematic uncertainty.
We report the first direct frequency comparison between two multi-ion optical clocks based on the S1/2 to D5/2 transition in \Ca and \Sr ions. Using linear chains of up to nine \Ca ions and six \Sr ions, we demonstrate improved stability as a function of the number of ions that are contributing to the laser frequency stabilization servo. The measured joint fractional frequency stability of the two clocks reaches 1.37(12)×10−15 at one second, placing an upper bound on the same stability of one of the clocks at 9.6(8)×10−16 in one second. We measured the frequency ratio of the two clocks to be RSr/Ca=1.082076536381896986(18), where the systematic uncertainty is primarily limited by the room temperature blackbody radiation. Our direct measurement represents an order of magnitude improvement compared to existing indirect frequency ratio measurements. Furthermore, by combining our results with recent absolute frequency measurements of the \Sr transition, referenced to a primary frequency standard, we refined the absolute frequency of the \Ca transition to νCa+=411042129776400.21(4) Hz, reducing its uncertainty by a factor of three. This study presents the first direct comparison between two multi-ion optical clocks, highlighting their significant potential for future applications in fundamental physics tests, geodesy, and precision metrology.
Frequency standards based on optical transitions between electronic states of trapped ions have reached uncertainties below 10−18 [1]. The Stark shift caused by room-temperature blackbody radiation (BBR) causes the largest correction for most high-performance optical clock. The systematic uncertainty of 171Yb+ clocks based on the 2S1/2 (F = 0) → 2D3/2 (F = 2) electric quadrupole (E2) and 2S1/2 (F = 0) → 2F7/2 (F = 3) electric octupole (E3) transitions is currently limited to 28×10−18 and 1.5×10−18, respectively, by the fractional accuracy of the differential polarizability Δαdc of approximately 2% [2]. In the scope of this thesis, a dual species clock based on 171Yb+ and 88Sr+ ions was set up, operated and evaluated, to overcome this barrier. Since Δαdc is known with a smaller fractional uncertainty of 0.04% for the 2S1/2 → 2D5/2 E2 transition of 88Sr+ [3], this allows for a transfer of Δαdc from 88Sr+ to 171Yb+ following a method proposed in [4]. The optical intensity of a laser is calibrated with the Stark shift it causes on the 88Sr+ clock transition, allowing for the determination of Δαdc of the 171Yb+ clock transitions. This allows for a reduction of the fractional uncertainty of Δαdc for both 171Yb+ clock transitions below 0.4% and clock operation on the E2 and E3 transition with a fractional BBR shift uncertainty of 0.84×10−18 and 0.24×10−18 is enabled, respectively. However the value of Δαdc determined in this thesis does not agree with [2], a fractional offset of approximately 14% is observed. To investigate this discrepancy further, Δαdc is measured in the same manner as in [2] for the 88Sr+ clock transition. The same offset of approximately 14% is found, calling the accuracy of at least one of these methods into question. Finally, the first optical frequency ratio ℛ between the 88Sr+ clock transition and the 171Yb+ E3 transition is measured. The fractional uncertainty of ℛ is 23×10−18. ℛ in combination with the absolute frequency of the E3 transition allows for the determination of the 88Sr+ absolute frequency νSr+ with an uncertainty limited by the caesium references. The value of νSr+ falls outside of the recommended range, but is corroborated by measurements of the same quantity by other institutes [5, 6]. [1] M. Marshall et al., Phys. Rev. Lett. 135, 033201 (2025) [2] N. Huntemann et al., Phys. Rev. Lett. 116, 063001 (2016) [3] T. Lindvall et al., Phys. Rev. Lett. 135, 043402 (2025) [4] M. D. Barrett et al., Phys. Rev. A 100, 043418 (2019) [5] C. Marceau et al., Metrologia 62.4, 045001 (2025) [6] T. Lindvall et al., Phys. Rev. Appl. 24, 044082 (2025)
We experimentally investigate an optical frequency standard based on the (2)S1/2(F=0)→(2)F7/2(F=3) electric octupole (E3) transition of a single trapped (171)Yb+ ion. For the spectroscopy of this strongly forbidden transition, we utilize a Ramsey-type excitation scheme that provides immunity to probe-induced frequency shifts. The cancellation of these shifts is controlled by interleaved single-pulse Rabi spectroscopy, which reduces the related relative frequency uncertainty to 1.1×10(-18). To determine the frequency shift due to thermal radiation emitted by the ion's environment, we measure the static scalar differential polarizability of the E3 transition as 0.888(16)×10(-40) J m(2)/V(2) and a dynamic correction η(300 K)=-0.0015(7). This reduces the uncertainty due to thermal radiation to 1.8×10(-18). The residual motion of the ion yields the largest contribution (2.1×10(-18)) to the total systematic relative uncertainty of the clock of 3.2×10(-18).
We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .
Optical clocks have the potential to be 100 times more accurate than current best cesium atomic clocks within a fraction of the averaging time.This corresponds to a fractional uncertainty of the clock frequency on the level of 10 -18 and requires highaccuracy knowledge of systematic frequency shifts, such that they can be avoided or corrected for.In strontium optical lattice clocks an ensemble of ultracold strontium atoms is conned in an optical lattice, to allow for spectroscopy of the reference transition 5s 2 1 S 0 5s5p 3 P 0 in the Lamb-Dicke regime.The by far largest systematic frequency shift of the strontium clock transition is caused by its high sensitivity to blackbody radiation (BBR).The knowledge of the resulting frequency shift limited the achievable clock uncertainty to about 1 × 10 -16 .In this thesis for the rst time an experimental approach was followed, to determine the sensitivity of the strontium clock transition to blackbody radiation.At an environmental temperature of 300 K the resulting frequency shift corresponds to 2.277 8(23) Hz.The achieved uncertainty contributes with 5 × 10 -18 to the fractional systematic uncertainty of the clock frequency.The determination is based on a precision measurement of the dierence of static polarizabilities of the two clock states ∆α dc = α(5s5p 3 P 0 ) -α(5s 2 1 S 0 ) = 4.078 73(11) × 10 -39 Cm 2 /V.For this the dc Stark shift of the clock transition has been measured in the accurately known electric eld of a precision plate capacitor, which has been developed in this work.The attained static polarizability dierence ∆α dc corresponds to the rst term of a power series of the sensitivity to BBR.Higher orders are accumulated as dynamic part of the BBR shift.Which has been modelled using ∆α dc and experimental data for other atomic properties.To interrogate the ultracold atoms in the electric eld a novel transport technique has been developed, which uses the magic wavelength (813 nm) optical lattice to convey the atoms.For this, the interference pattern is translated together with the foci of the far-detuned lattice beams, by simultaneous translation of the lattice optics.In this way ultracold atoms have been transported within 250 ms over 5 cm, or several Rayleigh ranges respectively without signicant atom loss or heating.In the course of this work the rst frequency measurement with the strontium lattice clock of Physikalisch-Technischen Bundesanstalt (PTB) has been performed.The frequency of the 87 Sr clock transition was measured to be 429 228 004 229 872.9(5)Hz.The strontium lattice clock itself contributed with 1.5 × 10 -16 to the overall fractional uncertainty.Furthermore the thermal radiation eld in a cryogenic blackbody environment was modelled and a draft of a corresponding environment of the atoms was designed, which is suitable to be implemented in the strontium lattice clock of PTB.
Interspecies clock comparison below 5×10−18 uncertainty with a transportable clock
We report a measurement of the optical frequency ratio between the 2S1/2(F=0)--2F7/2(F=3) electric-octupole (E3) transition of 171Yb+ and the 1S0--3P0 transition of 87Sr, νYb+/νSr=1.4959916185449005881(65). Reaching a fractional uncertainty of 4.3×10−18, this result improves upon the previous best by more than a factor of three and is among the few that meet the requirements for interspecies clock comparisons specified by the roadmap towards the redefinition of the SI second. The comparison is between a transportable optical lattice clock and a stationary single-ion clock. It spans a period of nearly two years, during which the transportable clock was intermittently operated off-campus. The ratio was reproducibly measured during four separate campaigns, which are consistent within their statistical uncertainties. The results demonstrate reproducible 10−18 level operation of the transportable clock and thus validate its application for chronometric geodesy and as a transfer standard for inter-institute clock comparisons, e.g., in the absence of optical fiber links.