By performing two local displacement operations (LDOs) inside an SU(1,1) interferometer, called as the displacement-assisted SU(1,1) [DSU(1,1)], both the phase sensitivity based on homodyne detection and quantum Fisher information (QFI) with and without photon losses are investigated in this paper. In this DSU(1,1) interferometer, we focus our attention on the extent to which the introduced LDO affects the phase sensitivity and the QFI, even in the realistic scenario. Our analyses show that the estimation performance of DSU(1,1) interferometer is always better than that of SU(1,1) interferometer without the LDO, especially for the phase precision of the former in the ideal scenario closer to the Heisenberg limit via the increase of the LDO strength. Different from the latter, the robustness of the former can be also enhanced markedly by regulating and controlling the LDO. Our findings would open an useful view for quantum-improved phase estimation of optical interferometers.
By performing two local displacement operations (LDOs) inside an SU(1,1) interferometer, called as the displacement-assisted SU(1,1) [DSU(1,1)], both the phase sensitivity based on homodyne detection and quantum Fisher information (QFI) with and without photon losses are investigated in this paper. In this DSU(1,1) interferometer, we focus our attention on the extent to which the introduced LDO affects the phase sensitivity and the QFI, even in the realistic scenario. Our analyses show that the estimation performance of DSU(1,1) interferometer is always better than that of SU(1,1) interferometer without the LDO, especially for the phase precision of the former in the ideal scenario closer to the Heisenberg limit via the increase of the LDO strength. Different from the latter, the robustness of the former can be also enhanced markedly by regulating and controlling the LDO. Our findings would open an useful view for quantum-improved phase estimation of optical interferometers.
Abstract To improve the phase sensitivity, multi-photon subtraction schemes (multi-PSS) within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of multi-photon subtraction on phase sensitivity, quantum Fisher information (QFI), and quantum Cramér-Rao bound (QCRB) are analyzed under both ideal and photon losses situations. It is shown that the internal subtraction operation can improve the phase sensitivity, which becomes better performance by increasing subtraction number. It can also efficiently improve the robustness of the SU(1,1) interferometer against internal photon losses. By comparing separatively arbitrary photon subtraction on the two-mode inside SU(1,1) interferometer, the performance differences under different conditions are analyzed, including the asymmetric properties of non-Gaussian operations on the phase precision and the QFI. Our proposed scheme represents a valuable method for achieving quantum precision measurements.
We propose a novel method for enhancing phase estimation in the displacement-assisted SU(1,1) [DSU(1,1)] interferometer by incorporating the photon recycling technique, evaluated under both single-intensity detection (SID) and homodyne detection (HD) schemes. Our analysis shows that utilizing the photon recycling technique, the photon-recycled DSU(1,1) interferometer performs better than the conventional DSU(1,1) interferometer under certain conditions. We also demonstrate that this improvement is achievable in both SID and HD schemes. In addition, to discuss the maximum sensitivity achieved by our proposed model, we have calculated the quantum Cramér–Rao bound (QCRB) within the framework and found that our proposed model approaches the QCRB. Therefore, we believe that our findings offer a promising new approach to improving phase sensitivity through photon recycling.
Compared with passive interferometers, SU(1,1) interferometers demonstrate superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. Nevertheless, the measurement precision of these interferometers is considerably impacted by photon losses, particularly internal losses, thereby restricting the overall accuracy of measurements. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the available resources in quantum metrology, squeezing stands out as one of the most practical and efficient approaches. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the impact of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can significantly enhance the phase sensitivity and QFI by strengthening intramode correlations while weakening intermode correlations, thereby effectively improving the robustness of the SU(1,1) interferometer against photon losses.
Utilizing nonlinear elements, SU(1,1) interferometers demonstrate superior phase sensitivity compared to passive interferometers. However, the precision is significantly impacted by photon losses, particularly internal losses. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing a number-conserving operation (NCO), i.e., $a{a}^{\ifmmode\dagger\else\textdagger\fi{}}$ and ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$, inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We analyze the effects of the NCO on the phase sensitivity, the quantum Fisher information (QFI), and the quantum Cram\'er-Rao bound under both ideal and photon-loss scenarios. Our findings reveal that the internal non-Gaussian operations can enhance the phase sensitivity and the QFI and effectively improve the robustness of the SU(1,1) interferometer against internal photon losses. Notably, the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme exhibits superior improvement in both the ideal and photon-loss cases in terms of phase sensitivity. Moreover, in the ideal case, the $a{a}^{\ifmmode\dagger\else\textdagger\fi{}}$ scheme slightly outperforms the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme in terms of the QFI. However, in the presence of high photon losses, the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme demonstrates a greater advantage.
Abstract We derive a general phase-matching condition (PMC) for enhancement of sensitivity in SU(1,1) interferometers. Under this condition, the quantum Fisher information (QFI) of two-mode SU(1,1) interferometry becomes maximal with respect to the relative phase of two modes, for the case of an arbitrary state in one input port and an even (odd) state in the other port, and the phase sensitivity is enhanced. We also find that optimal parameters can let the QFI in some areas achieve the Heisenberg limit for both pure and mixed initial states. As examples, we consider several input states: coherent and even coherent states, squeezed vacuum and even coherent states, squeezed thermal and even coherent states. Furthermore, in the realistic scenario of the photon loss channel, we investigate the effect of photon losses on QFI with numerical studies. We find the PMC remains unchanged and is not affected by the transmission coefficients for the above input states. Our results suggest that the PMC can exist in various kinds of interferometers and the phase-matching is robust to even strong photon losses.
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.