arXiv:2207.05222 · Physical Review A

Temperature-shift-suppression scheme for two-photon two-color rubidium vapor clocks

Tin Nghia Nguyen, T. R. Schibli

Published Nov 3, 2022• 5 citations
arXivHTMLPDF

Abstract

We propose a scheme for interrogating a warm rubidium vapor using two different clock lasers. Performance wise, this approach is distinctly different from the recently proposed two-color two-photon rubidium clocks as our scheme does not trade off the ac Stark suppression against an increased sensitivity to the cell temperature or pressure. Instead, our approach compensates both the ac Stark shift and the temperature and pressure-induced frequency shifts. The proposed scheme also makes use of the modulation transfer technique, which enables a two orders of magnitude increase in the signal-to-noise ratio compared to traditional clocks that rely on fluorescence measurements.

DOI
10.1103/physreva.106.053104

Related papers

Suppressing the light shift in a two-photon rubidium optical frequency reference

Yorick Andeweg, John E. Kitching, Matthew T. Hummon

The two-photon transition in rubidium is an attractive candidate for use in the next generation of field-deployable atomic clocks and frequency references. However, this transition is known to suffer from a large AC Stark shift, through which fluctuations in the intensity of the interrogation laser cause fluctuations of the clock frequency, often limiting long-term stability. We implement an interrogation protocol known as the auto-compensated shift (ACS) in a two-photon rubidium optical frequency reference, reducing its sensitivity to optical intensity fluctuations by a factor of 1000. ACS alleviates the tradeoff between short-term and long-term stability imposed by the light shift and enables us to simultaneously achieve a fractional instability of 3 x 10^-14 at an integration time of 1 s and 2 x 10^-14 at an integration time of 10,000 s. We also examine a stability limit imposed on clocks using ACS by frequency noise on the laser.

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

A frequency shift compensation method for light shift and vapor-cell temperature shift in atomic clocks

Dou Li, Kangqi Liu, Linzhen Zhao +1 more

Light shift and vapor-cell temperature shift are the two most significant factors dominating the long-term instability of compact atomic clocks. Due to the different physical mechanisms, there is not yet a solution that can effectively suppress the frequency shifts induced by these two effects. Here, we propose a 'resonance-offset' locking approach that compensates for the two physical frequency shifts. In this approach, the additional offset locking shift can effectively counteract the atomic resonance shifts arising from changes in vapor-cell temperature and light power, reducing the net impact on the clock's frequency to nearly zero. We have demonstrated this strategy on the 778 nm Rubidium two-photon optical frequency standard, successfully compensating for light shift and cell-temperature shift, respectively. This general method is particularly appealing for compact vapor-cell microwave and optical atomic clocks designed for the excellent stability rather than accuracy.

arXiv:2405.14281•May 23, 2024•1 citation

Active compensation of the ac Stark shift in a two-photon rubidium optical frequency reference using power modulation

Yorick Andeweg, John E. Kitching, Matthew T. Hummon

We implement a feedback protocol to suppress the ac Stark shift in a two-photon rubidium optical frequency reference, reducing its sensitivity to optical power variations by a factor of 1000. This method alleviates the tradeoff between short-term and long-term stability imposed by the ac Stark shift, enabling us to simultaneously achieve instabilities of 3 × 10 − 14 at 1 s and 2 × 10 − 14 at 10 4 s. We also quantitatively describe, and experimentally explore, a stability limit imposed on clocks using this method by frequency noise on the local oscillator.

arXiv:2511.19702•Physical Review Applied•Feb 6, 2026•2 citations

A Comprehensive Review of Rubidium Two-Photon Vapor Cell Optical Clock: Long-Term Performance Limitations and Potential Improvements

Asagwegbe C. Obaze-Adeleke, Bryan Semon, Thejesh Bandi

Two-photon vapor cell-based optical clocks are strong candidates for next-generation portable atomic standards, offering simplicity, compactness, and high performance. Their narrow clock transitions with counter-propagating beams enable first-order Doppler-free operation. However, systematic perturbations such as the AC Stark shift, temperature-induced shift, and drifts resulting from the laser system pose challenges cause instabilities to medium- to long-term performance. This paper provides a comprehensive overview of Rb two-photon vapor cell optical standards, focusing on the long-term performance-limiting effects and potential mitigation strategies, aiming for clock stabilities better than 1 × 10−15 over the averaging time of a day and beyond.

Photonics•May 20, 2025•11 citations

Two-photon Optical Frequency Reference with Active ac Stark Shift Cancellation

Vladislav P. Gerginov, K. Beloy

The two-photon optical transition in rubidium offers a means to a simple, stable optical frequency reference. Here accuracy is limited by frequency drift due to fluctuations in light intensity, while stability is limited by the signal-to-noise ratio of detection. In its traditional implementation there is a tradeoff between accuracy and stability, set by the technical ability to control light intensity. This study uses a two-color excitation scheme for cancellation of light-induced frequency drifts, and replaces fluorescence with absorption in detection, allowing significant improvement of the standard's stability and accuracy.

arXiv:1808.01373•Physical Review Applied•Jul 30, 2018•37 citations

An optical atomic clock using 4 D J states of rubidium

Alisher Duspayev, C Owens, Bineet Dash +1 more

Abstract We analyze an optical atomic clock using two-photon 5 S 1 / 2 → 4 D J transitions in rubidium. Four one- and two-color excitation schemes to probe the 4 D 3 / 2 and 4 D 5 / 2 fine-structure states are considered in detail. We compare key characteristics of Rb 4 D J and 5 D 5 / 2 two-photon clocks. The 4 D J clock features a high signal-to-noise ratio due to two-photon decay at favorable wavelengths, low dc electric and magnetic susceptibilities, and minimal black-body shifts. Ac Stark shifts from the clock interrogation lasers are compensated by two-color Rabi-frequency matching. We identify a ‘magic’ wavelength near 1060 nm, which allows for in-trap, Doppler-free clock-transition interrogation with lattice-trapped cold atoms. From our analysis of clock statistics and systematics, we project a quantum-noise-limited relative clock stability at the 10 − 13 / τ ( s ) -level, with integration time τ in seconds, and a relative accuracy of ∼ 10 − 13 . We describe a potential architecture for implementing the proposed clock using a single telecom clock laser at 1550 nm, which is conducive to optical communication and long-distance clock comparisons. Our work could be of interest in efforts to realize small and portable Rb clocks and in high-precision measurements of atomic properties of Rb 4 D J -states.

arXiv:2406.09352•Quantum Science and Technology•Sep 6, 2024•7 citations
We propose a scheme for interrogating a warm rubidium vapor using two different clock lasers. Performance wise, this approach is distinctly different from the recently proposed two-color two-photon rubidium clocks as our scheme does not trade off the ac Stark suppression against an increased sensitivity to the cell temperature or pressure. Instead, our approach compensates both the ac Stark shift and the temperature and pressure-induced frequency shifts. The proposed scheme also makes use of the modulation transfer technique, which enables a two orders of magnitude increase in the signal-to-noise ratio compared to traditional clocks that rely on fluorescence measurements.
The two-photon transition in rubidium is an attractive candidate for use in the next generation of field-deployable atomic clocks and frequency references. However, this transition is known to suffer from a large AC Stark shift, through which fluctuations in the intensity of the interrogation laser cause fluctuations of the clock frequency, often limiting long-term stability. We implement an interrogation protocol known as the auto-compensated shift (ACS) in a two-photon rubidium optical frequency reference, reducing its sensitivity to optical intensity fluctuations by a factor of 1000. ACS alleviates the tradeoff between short-term and long-term stability imposed by the light shift and enables us to simultaneously achieve a fractional instability of 3 x 10^-14 at an integration time of 1 s and 2 x 10^-14 at an integration time of 10,000 s. We also examine a stability limit imposed on clocks using ACS by frequency noise on the laser.
Light shift and vapor-cell temperature shift are the two most significant factors dominating the long-term instability of compact atomic clocks. Due to the different physical mechanisms, there is not yet a solution that can effectively suppress the frequency shifts induced by these two effects. Here, we propose a 'resonance-offset' locking approach that compensates for the two physical frequency shifts. In this approach, the additional offset locking shift can effectively counteract the atomic resonance shifts arising from changes in vapor-cell temperature and light power, reducing the net impact on the clock's frequency to nearly zero. We have demonstrated this strategy on the 778 nm Rubidium two-photon optical frequency standard, successfully compensating for light shift and cell-temperature shift, respectively. This general method is particularly appealing for compact vapor-cell microwave and optical atomic clocks designed for the excellent stability rather than accuracy.
We implement a feedback protocol to suppress the ac Stark shift in a two-photon rubidium optical frequency reference, reducing its sensitivity to optical power variations by a factor of 1000. This method alleviates the tradeoff between short-term and long-term stability imposed by the ac Stark shift, enabling us to simultaneously achieve instabilities of 3 × 10 − 14 at 1 s and 2 × 10 − 14 at 10 4 s. We also quantitatively describe, and experimentally explore, a stability limit imposed on clocks using this method by frequency noise on the local oscillator.
Two-photon vapor cell-based optical clocks are strong candidates for next-generation portable atomic standards, offering simplicity, compactness, and high performance. Their narrow clock transitions with counter-propagating beams enable first-order Doppler-free operation. However, systematic perturbations such as the AC Stark shift, temperature-induced shift, and drifts resulting from the laser system pose challenges cause instabilities to medium- to long-term performance. This paper provides a comprehensive overview of Rb two-photon vapor cell optical standards, focusing on the long-term performance-limiting effects and potential mitigation strategies, aiming for clock stabilities better than 1 × 10−15 over the averaging time of a day and beyond.
The two-photon optical transition in rubidium offers a means to a simple, stable optical frequency reference. Here accuracy is limited by frequency drift due to fluctuations in light intensity, while stability is limited by the signal-to-noise ratio of detection. In its traditional implementation there is a tradeoff between accuracy and stability, set by the technical ability to control light intensity. This study uses a two-color excitation scheme for cancellation of light-induced frequency drifts, and replaces fluorescence with absorption in detection, allowing significant improvement of the standard's stability and accuracy.
Abstract We analyze an optical atomic clock using two-photon 5 S 1 / 2 → 4 D J transitions in rubidium. Four one- and two-color excitation schemes to probe the 4 D 3 / 2 and 4 D 5 / 2 fine-structure states are considered in detail. We compare key characteristics of Rb 4 D J and 5 D 5 / 2 two-photon clocks. The 4 D J clock features a high signal-to-noise ratio due to two-photon decay at favorable wavelengths, low dc electric and magnetic susceptibilities, and minimal black-body shifts. Ac Stark shifts from the clock interrogation lasers are compensated by two-color Rabi-frequency matching. We identify a ‘magic’ wavelength near 1060 nm, which allows for in-trap, Doppler-free clock-transition interrogation with lattice-trapped cold atoms. From our analysis of clock statistics and systematics, we project a quantum-noise-limited relative clock stability at the 10 − 13 / τ ( s ) -level, with integration time τ in seconds, and a relative accuracy of ∼ 10 − 13 . We describe a potential architecture for implementing the proposed clock using a single telecom clock laser at 1550 nm, which is conducive to optical communication and long-distance clock comparisons. Our work could be of interest in efforts to realize small and portable Rb clocks and in high-precision measurements of atomic properties of Rb 4 D J -states.