Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1808.01373 · Physical Review Applied

Two-photon Optical Frequency Reference with Active ac Stark Shift Cancellation

Vladislav P. Gerginov, K. Beloy

Published Jul 30, 2018• 37 citations
arXivHTMLPDF

Abstract

The two-photon optical transition in rubidium offers a means to a simple, stable optical frequency reference. Here accuracy is limited by frequency drift due to fluctuations in light intensity, while stability is limited by the signal-to-noise ratio of detection. In its traditional implementation there is a tradeoff between accuracy and stability, set by the technical ability to control light intensity. This study uses a two-color excitation scheme for cancellation of light-induced frequency drifts, and replaces fluorescence with absorption in detection, allowing significant improvement of the standard's stability and accuracy.

DOI
10.1103/physrevapplied.10.014031

Related papers

Suppressing the light shift in a two-photon rubidium optical frequency reference

Yorick Andeweg, John E. Kitching, Matthew T. Hummon

The two-photon transition in rubidium is an attractive candidate for use in the next generation of field-deployable atomic clocks and frequency references. However, this transition is known to suffer from a large AC Stark shift, through which fluctuations in the intensity of the interrogation laser cause fluctuations of the clock frequency, often limiting long-term stability. We implement an interrogation protocol known as the auto-compensated shift (ACS) in a two-photon rubidium optical frequency reference, reducing its sensitivity to optical intensity fluctuations by a factor of 1000. ACS alleviates the tradeoff between short-term and long-term stability imposed by the light shift and enables us to simultaneously achieve a fractional instability of 3 x 10^-14 at an integration time of 1 s and 2 x 10^-14 at an integration time of 10,000 s. We also examine a stability limit imposed on clocks using ACS by frequency noise on the laser.

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

Active compensation of the ac Stark shift in a two-photon rubidium optical frequency reference using power modulation

Yorick Andeweg, John E. Kitching, Matthew T. Hummon

We implement a feedback protocol to suppress the ac Stark shift in a two-photon rubidium optical frequency reference, reducing its sensitivity to optical power variations by a factor of 1000. This method alleviates the tradeoff between short-term and long-term stability imposed by the ac Stark shift, enabling us to simultaneously achieve instabilities of 3 × 10 − 14 at 1 s and 2 × 10 − 14 at 10 4 s. We also quantitatively describe, and experimentally explore, a stability limit imposed on clocks using this method by frequency noise on the local oscillator.

arXiv:2511.19702•Physical Review Applied•Feb 6, 2026•2 citations

Light shift mitigation for the 5S-5D two-photon transition in rubidium

Roman Blum, Stefan Kundermann, Thibaud Ruelle +2 more

The rubidium two-photon optical atomic clock is a promising technology for applications that require a compact yet stable timekeeping device. However, its long-term frequency stability is often limited by the light shift (or AC Stark effect). In a rubidium two-photon frequency standard, we demonstrate in experiment that the light shift of the 778.1 nm wavelength probe beam can be mitigated with another, 1556.2 nm wavelength beam.

SPIE Quantum Technologies•Apr 5, 2024•0 citations

Tailoring the stability of a two-color, two-photon rubidium frequency standard

Emily J. Ahern, Sarah K. Scholten, Clayton R. Locke +4 more

Rubidium two-photon frequency standards are emerging as powerful contenders for compact, durable devices with exceptional stability. To date, the field has focused on single-color excitation; here, we demonstrate the key advantages of a two-color excitation of a two-photon optical frequency standard based on the $5{S}_{1/2}\ensuremath{\rightarrow}5{D}_{5/2}$ transition of rubidium-87 using driving fields at 780 and 776 nm. Using the $5{P}_{3/2}$ intermediate state to resonantly enhance the transition, we show that frequency stabilities comparable to rubidium single-color two-photon frequency standards can be attained, notably with approximately tenfold lower optical power and tenfold lower rubidium vapor density. Optimization of the detuning from the $5{P}_{3/2}$ intermediate state and of the optical powers of the driving lasers has a dramatic effect on the frequency stability, achieving the best short-term stability of any two-photon rubidium frequency standard to date: $6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ at $\ensuremath{\tau}=1$ s. We demonstrate that this level of performance is compatible with a compact geometry by fully self-referencing the frequency standard using an integrated fiber frequency comb to simultaneously stabilize the 780-nm laser's detuning from the $5{P}_{3/2}$ intermediate state, producing a frequency-stable microwave output. A comprehensive noise characterization underpins our observations of this two-color frequency standard, explaining the measured stability and showing that this frequency standard is initially shot-noise limited before becoming limited by light shifts in the long term. This work represents a major advance toward a low size, weight, and power frequency standard based on two-color excitation.

arXiv:2410.16654•Physical Review Applied•Apr 9, 2025•17 citations

Temperature-shift-suppression scheme for two-photon two-color rubidium vapor clocks

Tin Nghia Nguyen, T. R. Schibli

We propose a scheme for interrogating a warm rubidium vapor using two different clock lasers. Performance wise, this approach is distinctly different from the recently proposed two-color two-photon rubidium clocks as our scheme does not trade off the ac Stark suppression against an increased sensitivity to the cell temperature or pressure. Instead, our approach compensates both the ac Stark shift and the temperature and pressure-induced frequency shifts. The proposed scheme also makes use of the modulation transfer technique, which enables a two orders of magnitude increase in the signal-to-noise ratio compared to traditional clocks that rely on fluorescence measurements.

arXiv:2207.05222•Physical Review A•Nov 3, 2022•5 citations

Characterization of a Two-Photon Rubidium-87 Optical Clock

Sophia Rojas

Atomic clocks are based on highly stable and well-characterized atomic transitions, mak-ing precise control and understanding of systematic frequency shifts essential for improved timekeeping performance. This thesis presents an experimental study of light-induced Stark shifts in rubidium and their impact on precision laser spectroscopy relevant to atomic frequency standards, as well as the effects of residual amplitude modulation on the laser lock point and the resulting sensitivity of both short- and long-term stability. A laser-based spectroscopy system was developed to probe rubidium transitions while enabling controlled variation of optical intensity. The optical beam was experimentally characterized through calculations of beam waist and measurements of power to accurately determine the intensity at the interaction region. Frequency shifts arising from the AC Stark effect were measured as a function of optical power, allowing extraction of the differential polarizability between atomic energy levels using a theoretical model relating energy shifts to electric-field intensity. Uncertainty analysis was performed through systematic propagation of experimental errors associated with beam geometry, optical power calibration, and frequency measurements. In addition, residual amplitude modulation generated by electro-optic phase modulation was investigated as a significant source of systematic error in frequency stabilization systems used in atomic clocks. The magnitude and behavior of RAM were experimentally characterized, and its impact on frequency stability was quantified by measuring the sensitivity of the laser lock point to controlled variations in RAM. Potential mitigation strategies were then explored through active pre-compensation of RAM using an amplitude electro-optic modulator in a closed-loop feedback system.

•Jan 1, 2026•0 citations
The two-photon optical transition in rubidium offers a means to a simple, stable optical frequency reference. Here accuracy is limited by frequency drift due to fluctuations in light intensity, while stability is limited by the signal-to-noise ratio of detection. In its traditional implementation there is a tradeoff between accuracy and stability, set by the technical ability to control light intensity. This study uses a two-color excitation scheme for cancellation of light-induced frequency drifts, and replaces fluorescence with absorption in detection, allowing significant improvement of the standard's stability and accuracy.
The two-photon transition in rubidium is an attractive candidate for use in the next generation of field-deployable atomic clocks and frequency references. However, this transition is known to suffer from a large AC Stark shift, through which fluctuations in the intensity of the interrogation laser cause fluctuations of the clock frequency, often limiting long-term stability. We implement an interrogation protocol known as the auto-compensated shift (ACS) in a two-photon rubidium optical frequency reference, reducing its sensitivity to optical intensity fluctuations by a factor of 1000. ACS alleviates the tradeoff between short-term and long-term stability imposed by the light shift and enables us to simultaneously achieve a fractional instability of 3 x 10^-14 at an integration time of 1 s and 2 x 10^-14 at an integration time of 10,000 s. We also examine a stability limit imposed on clocks using ACS by frequency noise on the laser.
We implement a feedback protocol to suppress the ac Stark shift in a two-photon rubidium optical frequency reference, reducing its sensitivity to optical power variations by a factor of 1000. This method alleviates the tradeoff between short-term and long-term stability imposed by the ac Stark shift, enabling us to simultaneously achieve instabilities of 3 × 10 − 14 at 1 s and 2 × 10 − 14 at 10 4 s. We also quantitatively describe, and experimentally explore, a stability limit imposed on clocks using this method by frequency noise on the local oscillator.
Rubidium two-photon frequency standards are emerging as powerful contenders for compact, durable devices with exceptional stability. To date, the field has focused on single-color excitation; here, we demonstrate the key advantages of a two-color excitation of a two-photon optical frequency standard based on the $5{S}_{1/2}\ensuremath{\rightarrow}5{D}_{5/2}$ transition of rubidium-87 using driving fields at 780 and 776 nm. Using the 5P3/25{P}_{3/2}5P3/2​ intermediate state to resonantly enhance the transition, we show that frequency stabilities comparable to rubidium single-color two-photon frequency standards can be attained, notably with approximately tenfold lower optical power and tenfold lower rubidium vapor density. Optimization of the detuning from the 5P3/25{P}_{3/2}5P3/2​ intermediate state and of the optical powers of the driving lasers has a dramatic effect on the frequency stability, achieving the best short-term stability of any two-photon rubidium frequency standard to date: $6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ at $\ensuremath{\tau}=1$ s. We demonstrate that this level of performance is compatible with a compact geometry by fully self-referencing the frequency standard using an integrated fiber frequency comb to simultaneously stabilize the 780-nm laser's detuning from the 5P3/25{P}_{3/2}5P3/2​ intermediate state, producing a frequency-stable microwave output. A comprehensive noise characterization underpins our observations of this two-color frequency standard, explaining the measured stability and showing that this frequency standard is initially shot-noise limited before becoming limited by light shifts in the long term. This work represents a major advance toward a low size, weight, and power frequency standard based on two-color excitation.
We propose a scheme for interrogating a warm rubidium vapor using two different clock lasers. Performance wise, this approach is distinctly different from the recently proposed two-color two-photon rubidium clocks as our scheme does not trade off the ac Stark suppression against an increased sensitivity to the cell temperature or pressure. Instead, our approach compensates both the ac Stark shift and the temperature and pressure-induced frequency shifts. The proposed scheme also makes use of the modulation transfer technique, which enables a two orders of magnitude increase in the signal-to-noise ratio compared to traditional clocks that rely on fluorescence measurements.
Atomic clocks are based on highly stable and well-characterized atomic transitions, mak-ing precise control and understanding of systematic frequency shifts essential for improved timekeeping performance. This thesis presents an experimental study of light-induced Stark shifts in rubidium and their impact on precision laser spectroscopy relevant to atomic frequency standards, as well as the effects of residual amplitude modulation on the laser lock point and the resulting sensitivity of both short- and long-term stability. A laser-based spectroscopy system was developed to probe rubidium transitions while enabling controlled variation of optical intensity. The optical beam was experimentally characterized through calculations of beam waist and measurements of power to accurately determine the intensity at the interaction region. Frequency shifts arising from the AC Stark effect were measured as a function of optical power, allowing extraction of the differential polarizability between atomic energy levels using a theoretical model relating energy shifts to electric-field intensity. Uncertainty analysis was performed through systematic propagation of experimental errors associated with beam geometry, optical power calibration, and frequency measurements. In addition, residual amplitude modulation generated by electro-optic phase modulation was investigated as a significant source of systematic error in frequency stabilization systems used in atomic clocks. The magnitude and behavior of RAM were experimentally characterized, and its impact on frequency stability was quantified by measuring the sensitivity of the laser lock point to controlled variations in RAM. Potential mitigation strategies were then explored through active pre-compensation of RAM using an amplitude electro-optic modulator in a closed-loop feedback system.