arXiv:2203.15527 · Applied Physics Letters

Scanning nitrogen-vacancy magnetometry down to 350 mK

Patrick Scheidegger, S. Diesch, Marius L. Palm, Christian L. Degen

Published May 30, 2022• 39 citations
arXivHTMLPDF

Abstract

We report on the implementation of a scanning nitrogen-vacancy (NV) magnetometer in a dry dilution refrigerator. Using pulsed optically detected magnetic resonance combined with efficient microwave delivery through a co-planar waveguide, we reach a base temperature of 350 mK, limited by experimental heat load and thermalization of the probe. We demonstrate scanning NV magnetometry by imaging superconducting vortices in a 50-nm-thin aluminum microstructure. The sensitivity of our measurements is approximately 3 μT per square root Hz. Our work demonstrates the feasibility for performing noninvasive magnetic field imaging with scanning NV centers at sub-Kelvin temperatures.

DOI
10.1063/5.0093548

Related papers

Wideband microwave resonator for NV center vector magnetometry

S. V. Bolshedvorskii, E. A. Koreshin, V. V. Soshenko +10 more

The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about \[{1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;\]. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.

quant-pharXiv:2610.13379•Oct 12, 2026

Wide-field NV magnetometry under simultaneous high-pressure and high-temperature conditions

Masahiro Ohkuma, Eikichi Kimura, Shumpei Ohyama +7 more

We demonstrate wide-field optically detected magnetic resonance (ODMR) under simultaneous high-pressure and high-temperature conditions using nitrogen-vacancy (NV) centers. Although NV-center magnetometry has been widely used for spatially resolved magnetic-field imaging, its application to extreme environments combining pressure and temperature remains challenging. In this work, we show that ODMR can be observed at 5 GPa and 500 K, demonstrating the feasibility of NV spin readout under such combined extreme conditions. We further perform wide-field ODMR of iron at 7 GPa and 500 K, where the stray magnetic field from the sample is spatially visualized through the pressure cell. These results establish NV-center magnetometry as a promising platform for imaging magnetic phenomena in materials under high-pressure and high-temperature environments.

physics.app-phCross-listedarXiv:2606.25378•Jun 25, 2026

High-contrast absorption magnetometry in the visible to near-infrared range with nitrogen-vacancy ensembles

Florian Schall, Felix A. Hahl, Lukas Lindner +6 more

Magnetometry with nitrogen-vacancy (NV) centers in diamond has so far been measured via emission of light from NV centers or via absorption at the singlet transition at 1042 nm. Here, we demonstrate a phenomenon of broadband optical absorption by the NV centers starting in the emission wavelength and reaching up to 1000 nm. The measurements are enabled by a high-finesse cavity, which is used for room-temperature continuous wave pump-probe experiments. The red to infrared probe beam shows the typical optically detected magnetic resonance (ODMR) signal of the NV spin with contrasts up to 42 %. This broadband optical absorption has not yet been reported in terms of NV magnetometry. We argue that the lower level of the absorbing transition could be the energetically lower NV singlet state, based on the increased optical absorption for a resonant microwave field and the spectral behavior. Investigations of the photon-shot-noise-limited sensitivity show improvements with increasing probe wavelength, reaching an optimum of 7.5pT/Hz. The results show significantly improved ODMR contrast compared to emission-based magnetometry. This opens a new detection wavelength regime with coherent laser signal detection for high-sensitivity NV magnetometry.

arXiv:2412.07798•Optics Express•Jan 23, 2025•4 citations

High-resolution magnetic field imaging with a nitrogen-vacancy diamond sensor integrated with a photonic-crystal fiber

И. В. Федотов, Sean M. Blakley, Evgenii E. Serebryannikov +3 more

We demonstrate high-resolution magnetic field imaging with a scanning fiber-optic probe which couples nitrogen-vacancy (NV) centers in diamond to a high-numerical-aperture photonic-crystal fiber integrated with a two-wire microwave transmission line. Magnetic resonance excitation of NV centers driven by the microwave field is read out through optical interrogation through the photonic-crystal fiber to enable high-speed, high-sensitivity magnetic field imaging with sub 30 μm spatial resolution.

Optics Letters•Jan 22, 2016•51 citations

Quantitative imaging of Abrikosov vortices by scanning quantum magnetometry

Clemens Schäfermeier, Ankit Sharma, Christopher Kelvin von Grundherr +5 more

Understanding vortex matter in type-II superconductors is central to controlling dissipation and flux pinning in superconducting materials and devices. Here, we use cryogenic scanning nitrogen vacancy magnetometry (NVM) to image Abrikosov vortices in the cuprate superconductors BSCCO-2212 and YBCO under controlled field-cooled conditions. Measurements, which are performed using continuous-wave optically detected magnetic resonance (cw-ODMR) in a closed-cycle cryostat, yield quantitative magnetic-field maps with nanoscale spatial resolution. In BSCCO-2212 at 71 K, we resolve a well-ordered triangular vortex lattice, whose symmetry and spacing are confirmed through 2D Fourier analysis and are consistent with flux quantization. YBCO thin films imaged at 3 K exhibit a more disordered vortex arrangement reflecting stronger pinning, while maintaining quantitative agreement between measured vortex density and the applied magnetic field. These results render our cryogenic scanning NVM a reliable quantitative tool for real-space studies of vortices in high-$T_c$ superconductors, in particular since such a remarkable magnetic resolution has been achieved within relatively short acquisition times of 2 to 4 h.

cond-mat.supr-conCross-listedarXiv:2602.13060•Feb 16, 2026

Microwave-free magnetometry based on cross-relaxation resonances in diamond nitrogen-vacancy centers

Р. А. Ахмеджанов, Л. А. Гущин, Н. А. Низов +4 more

We study cross-relaxation resonances between differently oriented groups of nitrogen-vacancy (NV) centers at small external magnetic fields. These resonances are observed using resonant optical pumping on the NV-center zero phonon line. We suggest a magnetometry protocol that is based on measuring the positions of cross-relaxation resonances on the fluorescence scan. This protocol does not require microwave radiation and can be used to find all components of the unknown magnetic field vector. A room-temperature variant of the protocol with off-resonant optical pumping is also briefly discussed.

Physical Review A•Jul 6, 2017•36 citations
We report on the implementation of a scanning nitrogen-vacancy (NV) magnetometer in a dry dilution refrigerator. Using pulsed optically detected magnetic resonance combined with efficient microwave delivery through a co-planar waveguide, we reach a base temperature of 350 mK, limited by experimental heat load and thermalization of the probe. We demonstrate scanning NV magnetometry by imaging superconducting vortices in a 50-nm-thin aluminum microstructure. The sensitivity of our measurements is approximately 3 μT per square root Hz. Our work demonstrates the feasibility for performing noninvasive magnetic field imaging with scanning NV centers at sub-Kelvin temperatures.
The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about 1.2 nT/Hz  {1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;1.2 nT/Hz​. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.
We demonstrate wide-field optically detected magnetic resonance (ODMR) under simultaneous high-pressure and high-temperature conditions using nitrogen-vacancy (NV) centers. Although NV-center magnetometry has been widely used for spatially resolved magnetic-field imaging, its application to extreme environments combining pressure and temperature remains challenging. In this work, we show that ODMR can be observed at 5 GPa and 500 K, demonstrating the feasibility of NV spin readout under such combined extreme conditions. We further perform wide-field ODMR of iron at 7 GPa and 500 K, where the stray magnetic field from the sample is spatially visualized through the pressure cell. These results establish NV-center magnetometry as a promising platform for imaging magnetic phenomena in materials under high-pressure and high-temperature environments.
Magnetometry with nitrogen-vacancy (NV) centers in diamond has so far been measured via emission of light from NV centers or via absorption at the singlet transition at 1042 nm. Here, we demonstrate a phenomenon of broadband optical absorption by the NV centers starting in the emission wavelength and reaching up to 1000 nm. The measurements are enabled by a high-finesse cavity, which is used for room-temperature continuous wave pump-probe experiments. The red to infrared probe beam shows the typical optically detected magnetic resonance (ODMR) signal of the NV spin with contrasts up to 42 %. This broadband optical absorption has not yet been reported in terms of NV magnetometry. We argue that the lower level of the absorbing transition could be the energetically lower NV singlet state, based on the increased optical absorption for a resonant microwave field and the spectral behavior. Investigations of the photon-shot-noise-limited sensitivity show improvements with increasing probe wavelength, reaching an optimum of 7.5pT/Hz. The results show significantly improved ODMR contrast compared to emission-based magnetometry. This opens a new detection wavelength regime with coherent laser signal detection for high-sensitivity NV magnetometry.
Understanding vortex matter in type-II superconductors is central to controlling dissipation and flux pinning in superconducting materials and devices. Here, we use cryogenic scanning nitrogen vacancy magnetometry (NVM) to image Abrikosov vortices in the cuprate superconductors BSCCO-2212 and YBCO under controlled field-cooled conditions. Measurements, which are performed using continuous-wave optically detected magnetic resonance (cw-ODMR) in a closed-cycle cryostat, yield quantitative magnetic-field maps with nanoscale spatial resolution. In BSCCO-2212 at 71 K, we resolve a well-ordered triangular vortex lattice, whose symmetry and spacing are confirmed through 2D Fourier analysis and are consistent with flux quantization. YBCO thin films imaged at 3 K exhibit a more disordered vortex arrangement reflecting stronger pinning, while maintaining quantitative agreement between measured vortex density and the applied magnetic field. These results render our cryogenic scanning NVM a reliable quantitative tool for real-space studies of vortices in high-TcT_cTc​ superconductors, in particular since such a remarkable magnetic resolution has been achieved within relatively short acquisition times of 2 to 4 h.
We study cross-relaxation resonances between differently oriented groups of nitrogen-vacancy (NV) centers at small external magnetic fields. These resonances are observed using resonant optical pumping on the NV-center zero phonon line. We suggest a magnetometry protocol that is based on measuring the positions of cross-relaxation resonances on the fluorescence scan. This protocol does not require microwave radiation and can be used to find all components of the unknown magnetic field vector. A room-temperature variant of the protocol with off-resonant optical pumping is also briefly discussed.