Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2112.09004 · Physical Review Applied

Femtotesla Nearly-Quantum-Noise-Limited Pulsed Gradiometer at Earth-Scale Fields

Vito Giovanni Lucivero, Wonjae Lee, Mark E. Limes, Elizabeth L. Foley, Thomas W. Kornack, Michael V. Romalis

Published Aug 12, 2022• 57 citations
arXivHTMLPDF

Abstract

Applications of optical magnetometers in demanding environments require a high common-mode rejection ratio (CMRR) to effectively suppress ambient noise, but challenges still remain to achieve experimental sensitivity at the quantum noise level. The authors develop a compact magnetic gradiometer featuring a high CMRR and a differential sensitivity of tens of femtoteslas over a broad dynamic range, including Earth's field magnitude. This gradiometer is also nearly quantum-noise-limited, which is compatible with quantum enhancement techniques in geomagnetic fields and can be used in unshielded environments such as space science, navigation, and biomedicine.

DOI
10.1103/physrevapplied.18.l021001

Related papers

Entangled Light Enabled Quantum Magnetic Gradiometer

Shuhe Wu, Guzhi Bao, L. Q. Chen +1 more

We present a quantum magnetic gradiometer that achieves sub-shot-noise sensitivity through the use of entangled twin beams and differential detection. Benefiting from large quantum enhancement, high common-mode rejection ratio, and best sensitivity ever observed in magnetometry with squeezed light, the developed quantum gradiometer opens up new possibilities for utilizing quantum-enhanced technology in the development of sensitive magnetometry for practical applications in noisy and physically demanding environments.

Photonics & Electromagnetics Research Symposium (PIERS)•Apr 21, 2024•0 citations

Spin-Feedback-Enhanced Atomic Magnetic Gradiometer

Yujian Ma, Shudong Lin, Ziqi Yuan +2 more

Feedback-based spin control has recently attracted increasing attention, with initial implementations in systems such as spin masers and comagnetometers. Here, we demonstrate the first implementation of spin feedback in dual-cell spin-exchange relaxation-free (SERF) gradiometers, achieving a significant enhancement in overall performance. We analyze the stability boundary for spin feedback theoretically, which enables the amplification of spin response while ensuring self-oscillation-free operation. The differential magnetic signal experimentally benefits from the enhanced response and shows a significant improvement in the time domain. Moreover, introducing the feedback factor as an additional parameter enables delicate control of the phase response between two channels, facilitating broadband phase matching across gradiometer channels with different intrinsic parameters and magnetic-field environments. The engineered spin feedback control enhances differential sensitivity and suppresses common-mode noise, improving the average common-mode rejection ratio (CMRR) across 1–100 Hz by an order of magnitude to nearly 3000, with a noise floor of 10 fT/Hz${}^{\text {1/2}}$.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•1 citation

Quantum magnetic gradiometer with entangled twin light beams

Shuhe Wu, Guzhi Bao, Jinxian Guo +6 more

In the past few decades, optical magnetometry has experienced remarkable development and reached to an outstanding sensitivity. For magnetometry based on optical readout of atomic ensemble, the fundamental limitation of sensitivity is restricted by spin projection noise and photon shot noise. Meanwhile, in practical applications, ambient magnetic noise also greatly limits the sensitivity. To achieve the best sensitivity, it is essential to find an efficacious way to eliminate the noises from different sources, simultaneously. Here, we demonstrate a quantum magnetic gradiometer with sub-shot-noise sensitivity using entangled twin beams with differential detection. The quantum enhancement spans a frequency range from 7 Hz to 6 MHz with maximum squeezing of 5.5 dB below the quantum noise limit. The sensitivity of gradiometer reaches 18 fT/cm Hz at 20 Hz. Our study inspires future possibilities to use quantum-enhanced technology in developing sensitive magnetometry for practical applications in noisy and physically demanding environments.

Science Advances•Apr 12, 2023•51 citations

A femtotesla quantum-noise-limited pulsed gradiometer at finite fields

Vito Giovanni Lucivero, Wonjae Lee, Mark E. Limes +3 more

We describe an optically pumped atomic gradiometer operating at finite fields, including Earth’s field, with 14 fT / Hz Hz sensitivity. We demonstrate its quantum-noise-limited behaviour in the presence of quantum spin noise and atomic diffusion.

Quantum Information and Measurement (QIM)•Jan 1, 2019•8 citations

Magnetometry with a space-based differential atom interferometer

Matthias Meister, Gabriel Müller, Patrick Boegel +16 more

Atom interferometers deployed in space are excellent tools for high precision measurements, navigation, or Earth observation. In particular, differential interferometric setups feature common-mode noise suppression and enable reliable measurements in the presence of ambient platform noise. Here we report on orbital magnetometry campaigns performed with differential single- and double-loop interferometers in NASA's Cold Atom Lab aboard the International Space Station. By comparing measurements with atoms in magnetically sensitive and insensitive states, we have realized atomic magnetometers mapping magnetic field curvatures. Our results pave the way towards precision quantum sensing missions in space.

arXiv:2505.23532•Nature Communications•Jul 11, 2026•5 citations

All-optical intrinsic atomic gradiometer with sub-20 fT/cm/√Hz sensitivity in a 22 µT earth-scale magnetic field

Abigail R. Perry, Michael Bulatowicz, M. Larsen +2 more

In this work we demonstrate a high sensitivity atomic gradiometer capable of operation in earth-field level environments. We apply a light-pulse sequence at four times the Larmor frequency to achieve gradiometer sensitivity <20 fT/cm/ H z at the finite field strength of 22 µT. The experimental timing sequence can be tuned to the field magnitude of interest. Our all-optical scalar gradiometer performs a differential measurement between two regions of a single vapor cell on a 4 cm baseline. Our results pave the way for extensions to operation in higher dimensions, vector sensitivity, and more advanced gradiometers.

arXiv:2008.13234•Optics Express•Nov 10, 2020•42 citations
Applications of optical magnetometers in demanding environments require a high common-mode rejection ratio (CMRR) to effectively suppress ambient noise, but challenges still remain to achieve experimental sensitivity at the quantum noise level. The authors develop a compact magnetic gradiometer featuring a high CMRR and a differential sensitivity of tens of femtoteslas over a broad dynamic range, including Earth's field magnitude. This gradiometer is also nearly quantum-noise-limited, which is compatible with quantum enhancement techniques in geomagnetic fields and can be used in unshielded environments such as space science, navigation, and biomedicine.
We present a quantum magnetic gradiometer that achieves sub-shot-noise sensitivity through the use of entangled twin beams and differential detection. Benefiting from large quantum enhancement, high common-mode rejection ratio, and best sensitivity ever observed in magnetometry with squeezed light, the developed quantum gradiometer opens up new possibilities for utilizing quantum-enhanced technology in the development of sensitive magnetometry for practical applications in noisy and physically demanding environments.
Feedback-based spin control has recently attracted increasing attention, with initial implementations in systems such as spin masers and comagnetometers. Here, we demonstrate the first implementation of spin feedback in dual-cell spin-exchange relaxation-free (SERF) gradiometers, achieving a significant enhancement in overall performance. We analyze the stability boundary for spin feedback theoretically, which enables the amplification of spin response while ensuring self-oscillation-free operation. The differential magnetic signal experimentally benefits from the enhanced response and shows a significant improvement in the time domain. Moreover, introducing the feedback factor as an additional parameter enables delicate control of the phase response between two channels, facilitating broadband phase matching across gradiometer channels with different intrinsic parameters and magnetic-field environments. The engineered spin feedback control enhances differential sensitivity and suppresses common-mode noise, improving the average common-mode rejection ratio (CMRR) across 1–100 Hz by an order of magnitude to nearly 3000, with a noise floor of 10 fT/Hz1/2{}^{\text {1/2}}1/2.
In the past few decades, optical magnetometry has experienced remarkable development and reached to an outstanding sensitivity. For magnetometry based on optical readout of atomic ensemble, the fundamental limitation of sensitivity is restricted by spin projection noise and photon shot noise. Meanwhile, in practical applications, ambient magnetic noise also greatly limits the sensitivity. To achieve the best sensitivity, it is essential to find an efficacious way to eliminate the noises from different sources, simultaneously. Here, we demonstrate a quantum magnetic gradiometer with sub-shot-noise sensitivity using entangled twin beams with differential detection. The quantum enhancement spans a frequency range from 7 Hz to 6 MHz with maximum squeezing of 5.5 dB below the quantum noise limit. The sensitivity of gradiometer reaches 18 fT/cm Hz at 20 Hz. Our study inspires future possibilities to use quantum-enhanced technology in developing sensitive magnetometry for practical applications in noisy and physically demanding environments.
Atom interferometers deployed in space are excellent tools for high precision measurements, navigation, or Earth observation. In particular, differential interferometric setups feature common-mode noise suppression and enable reliable measurements in the presence of ambient platform noise. Here we report on orbital magnetometry campaigns performed with differential single- and double-loop interferometers in NASA's Cold Atom Lab aboard the International Space Station. By comparing measurements with atoms in magnetically sensitive and insensitive states, we have realized atomic magnetometers mapping magnetic field curvatures. Our results pave the way towards precision quantum sensing missions in space.
In this work we demonstrate a high sensitivity atomic gradiometer capable of operation in earth-field level environments. We apply a light-pulse sequence at four times the Larmor frequency to achieve gradiometer sensitivity <20 fT/cm/ H z at the finite field strength of 22 µT. The experimental timing sequence can be tuned to the field magnitude of interest. Our all-optical scalar gradiometer performs a differential measurement between two regions of a single vapor cell on a 4 cm baseline. Our results pave the way for extensions to operation in higher dimensions, vector sensitivity, and more advanced gradiometers.