Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Instrumentation and Measurement

Spin-Feedback-Enhanced Atomic Magnetic Gradiometer

Yujian Ma, Shudong Lin, Ziqi Yuan, Yueyang Zhai, Junjian Tang

Published Jan 1, 2026• 1 citation
Publisher

Abstract

Feedback-based spin control has recently attracted increasing attention, with initial implementations in systems such as spin masers and comagnetometers. Here, we demonstrate the first implementation of spin feedback in dual-cell spin-exchange relaxation-free (SERF) gradiometers, achieving a significant enhancement in overall performance. We analyze the stability boundary for spin feedback theoretically, which enables the amplification of spin response while ensuring self-oscillation-free operation. The differential magnetic signal experimentally benefits from the enhanced response and shows a significant improvement in the time domain. Moreover, introducing the feedback factor as an additional parameter enables delicate control of the phase response between two channels, facilitating broadband phase matching across gradiometer channels with different intrinsic parameters and magnetic-field environments. The engineered spin feedback control enhances differential sensitivity and suppresses common-mode noise, improving the average common-mode rejection ratio (CMRR) across 1–100 Hz by an order of magnitude to nearly 3000, with a noise floor of 10 fT/Hz${}^{\text {1/2}}$.

DOI
10.1109/tim.2026.3704257

Related papers

Spin-exchange relaxation-free magnetic gradiometer with dual-beam and closed-loop Faraday modulation

Jiancheng Fang, Shuangai Wan, Jie Qin +2 more

Spin-exchange relaxation-free (SERF) atomic magnetometers usually adopt Faraday modulation to achieve better performance but suffer from laser intensity noise, thermal noise generated by the Faraday modulator, and nonmagnetic technical noise. These noises limit the sensitivity of the SERF magnetometer. We demonstrate a SERF magnetic gradiometer with dual-beam and closed-loop Faraday modulation. Operating in the SERF regime, the gradiometer utilizes an additional Faraday modulator rotation feedback to suppress probe laser intensity noise and thermal noise associated with the Faraday modulator, and it simultaneously uses dual-beam difference to cancel common-mode nonmagnetic technical noises. A gradient sensitivity of 14 fT/Hz1/2 per 1 cm gradiometer base length was achieved using Cs atoms.

Journal of the Optical Society of America B•Feb 12, 2014•24 citations

Spin-amplification SERF atomic magnetometer based on direct feedback

Yong Ma, Ziqi Yuan, Shudong Lin +2 more

We demonstrate that atomic spin trajectories on the Bloch sphere can be manipulated through direct feedback, achieving spin amplification. This method is applied to Spin-Exchange Relaxation-Free (SERF) magnetometers where a feedback loop introduces a magnetic field positively proportional to the transverse spin polarization, which significantly amplifies the low-frequency response signal by an order of magnitude. Experimental results show that the feedback mechanism improves the signal-to-noise ratio and effectively strengthens the system’s ability to suppress technical noise. In addition, this feedback-enabled magnetometer exhibits superior sensitivity at lower spin polarization, reducing reliance on optical power and thereby facilitating scalability in multi-channel systems. This approach can be extended to various physical systems utilizing atomic spins, such as quantum memory and quantum metrology.

EPJ Quantum Technology•Jun 11, 2025•7 citations

Effects of system parameters on a single-beam synthetic gradiometer with a dual-cell structure

Zinan Wu, Jialong Zhang, Wei Chen +4 more

We report a single-beam synthetic gradiometer operated in the spin-exchange-relaxation free (SERF) regime, using the structure of two separate atomic vapor cells spaced 2 cm apart. To improve the capability of the gradiometer in suppressing the common-mode magnetic field noise, we are aiming at investigating the effects of the system parameters on the gradiometer common-mode rejection ratio (CMRR). The mathematical expression for the relationship between the gradiometer CMRR and the two variables including the linewidth ratio and the pumping factor ratio is constructed for the first time, to our knowledge. This means that the CMRR can be optimized by controlling the linewidth and the pumping factor, which is easy to implement in the operation process. As a result, a CMRR of 246 is achieved and a gradiometer sensitivity of 4.5 fT/cm/Hz 1/2 is also measured. This method provides a theoretical and experimental basis for the automated operation of gradiometers, and the gradiometer system performance can be tuned to a desired state by simply controlling the linewidth and the incident light intensity.

Optics Letters•Apr 18, 2024•8 citations

A Performance-Enhanced Closed-Loop SERF Atomic Magnetometer

Ziao Liu, Jianli Li, Xiaoyu Li +3 more

The spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) exhibit ultrahigh sensitivity in ultraweak magnetic field measurement, but their narrow bandwidth constrains the scope of their applications. To increase the bandwidth, magnetic field closed-loop control technology has been introduced into AMs with demonstrated efficacy. However, previous research on closed-loop AMs resulted in signal distortion problems, primarily due to imprecise closed-loop models and control parameters selection without theoretical support. This problem is specifically characterized by the unexpected amplification or reduction of signals at certain frequencies, directly leading to the degradation of the frequency performance of the closed-loop AM, making it unsuitable for applications requiring full-bandwidth measurement. In this study, we proposed a performance-enhanced closed-loop SERF AM, maximizing the bandwidth while ensuring consistent performance across the entire bandwidth. An accurate closed-loop system model was first established. Subsequently, an optimal relationship between the control parameters was proposed according to the eigenvalues of the closed-loop system, and the particle swarm optimization (PSO) algorithm was introduced to determine the optimal control parameters. The improved closed-loop system was constructed in a triaxial SERF AM, achieving an average bandwidth of 410 Hz and a sensitivity of 10 fT/Hz$^{{1}/{2}}$in three axes, while ensuring consistent performance across the entire bandwidth. With the proposed method, the optimized control parameters can be obtained only by requiring the frequency response of the open-loop AM, which is convenient and useful for closed-loop AM applications.

IEEE Sensors Journal•Oct 1, 2024•5 citations

Dual-Axis Closed Loop of a Single-Beam Atomic Magnetometer: Toward High Bandwidth and High Sensitivity

Junjian Tang, Yueyang Zhai, Binquan Zhou +2 more

Atomic magnetometers operated in spin-exchange relaxation-free (SERF) have the potential to replace superconducting quantum interference devices (SQUIDs) in the field of biomagnetism. Here, we demonstrate the dual-axis closed-loop control of a single-beam SERF magnetometer that allows sensing of two orthogonal magnetic fields simultaneously and independently with suppressed cross-talk effect, achieved by applying a rotating modulation field and using of the negative feedback. Operating in the dual-axis closed-loop mode with a miniature 4 × 4 × 4 mm 87Rb cell, we achieve magnetic field sensitivity of 20 fT/Hz1/2 and a bandwidth of 1.8 kHz. In addition to the experimental study of the sensitivity and bandwidth, we perform a theoretical analysis to the dual-axis response and develop an effective decoupling method. The implementation of closed-loop control enables the magnetometer to be robust against the disturbance of the ambient field, which could enlarge the dynamic range, enhance the systematic stability, and suppress the cross-talk effect. Such a simple, yet high-performance SERF magnetometer could be suitable as a promising candidate in the field of biomagnetism, allowing for a denser sensor array and opening up new possibilities for the noninvasive biomagnetic imaging.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2021•95 citations

Dynamically polarized atomic comagnetometer

Xiaofei Huang, Kai Wei, Yang Rui +4 more

Atomic spin sensors are essential for beyond-the-standard-model exploration, biomagnetic measurement, and quantum navigation. While the traditional DC mode spin-exchange relaxation-free (SERF) comagnetometer achieves ultrahigh sensitivity, further improvements require suppressing technical noise and surpassing standard quantum limit. In this work, we develop a K-Rb- 21 Ne SERF atomic comagnetometer that dynamically polarizes the electron and nuclear spins, shielding signals from direct interference by pump light. We establish a three-phase evolutionary model for hybrid spin ensemble dynamics, yielding a complete analytical solution, and analyze the responses to various spin perturbations. Additionally, we achieve an average 39% suppression of the polarization noise and identify the key factors that limit sensitivity improvements. The dynamically polarized comagnetometer exhibits effective suppression of technical noise and holds the potential to overcome quantum noise limit while offering promising applications in exploring new physics and precise magnetic field measurements.

arXiv:2505.18462•Cell Reports Physical Science•Nov 1, 2025•2 citations
Feedback-based spin control has recently attracted increasing attention, with initial implementations in systems such as spin masers and comagnetometers. Here, we demonstrate the first implementation of spin feedback in dual-cell spin-exchange relaxation-free (SERF) gradiometers, achieving a significant enhancement in overall performance. We analyze the stability boundary for spin feedback theoretically, which enables the amplification of spin response while ensuring self-oscillation-free operation. The differential magnetic signal experimentally benefits from the enhanced response and shows a significant improvement in the time domain. Moreover, introducing the feedback factor as an additional parameter enables delicate control of the phase response between two channels, facilitating broadband phase matching across gradiometer channels with different intrinsic parameters and magnetic-field environments. The engineered spin feedback control enhances differential sensitivity and suppresses common-mode noise, improving the average common-mode rejection ratio (CMRR) across 1–100 Hz by an order of magnitude to nearly 3000, with a noise floor of 10 fT/Hz1/2{}^{\text {1/2}}1/2.
Spin-exchange relaxation-free (SERF) atomic magnetometers usually adopt Faraday modulation to achieve better performance but suffer from laser intensity noise, thermal noise generated by the Faraday modulator, and nonmagnetic technical noise. These noises limit the sensitivity of the SERF magnetometer. We demonstrate a SERF magnetic gradiometer with dual-beam and closed-loop Faraday modulation. Operating in the SERF regime, the gradiometer utilizes an additional Faraday modulator rotation feedback to suppress probe laser intensity noise and thermal noise associated with the Faraday modulator, and it simultaneously uses dual-beam difference to cancel common-mode nonmagnetic technical noises. A gradient sensitivity of 14 fT/Hz1/2 per 1 cm gradiometer base length was achieved using Cs atoms.
We demonstrate that atomic spin trajectories on the Bloch sphere can be manipulated through direct feedback, achieving spin amplification. This method is applied to Spin-Exchange Relaxation-Free (SERF) magnetometers where a feedback loop introduces a magnetic field positively proportional to the transverse spin polarization, which significantly amplifies the low-frequency response signal by an order of magnitude. Experimental results show that the feedback mechanism improves the signal-to-noise ratio and effectively strengthens the system’s ability to suppress technical noise. In addition, this feedback-enabled magnetometer exhibits superior sensitivity at lower spin polarization, reducing reliance on optical power and thereby facilitating scalability in multi-channel systems. This approach can be extended to various physical systems utilizing atomic spins, such as quantum memory and quantum metrology.
We report a single-beam synthetic gradiometer operated in the spin-exchange-relaxation free (SERF) regime, using the structure of two separate atomic vapor cells spaced 2 cm apart. To improve the capability of the gradiometer in suppressing the common-mode magnetic field noise, we are aiming at investigating the effects of the system parameters on the gradiometer common-mode rejection ratio (CMRR). The mathematical expression for the relationship between the gradiometer CMRR and the two variables including the linewidth ratio and the pumping factor ratio is constructed for the first time, to our knowledge. This means that the CMRR can be optimized by controlling the linewidth and the pumping factor, which is easy to implement in the operation process. As a result, a CMRR of 246 is achieved and a gradiometer sensitivity of 4.5 fT/cm/Hz 1/2 is also measured. This method provides a theoretical and experimental basis for the automated operation of gradiometers, and the gradiometer system performance can be tuned to a desired state by simply controlling the linewidth and the incident light intensity.
The spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) exhibit ultrahigh sensitivity in ultraweak magnetic field measurement, but their narrow bandwidth constrains the scope of their applications. To increase the bandwidth, magnetic field closed-loop control technology has been introduced into AMs with demonstrated efficacy. However, previous research on closed-loop AMs resulted in signal distortion problems, primarily due to imprecise closed-loop models and control parameters selection without theoretical support. This problem is specifically characterized by the unexpected amplification or reduction of signals at certain frequencies, directly leading to the degradation of the frequency performance of the closed-loop AM, making it unsuitable for applications requiring full-bandwidth measurement. In this study, we proposed a performance-enhanced closed-loop SERF AM, maximizing the bandwidth while ensuring consistent performance across the entire bandwidth. An accurate closed-loop system model was first established. Subsequently, an optimal relationship between the control parameters was proposed according to the eigenvalues of the closed-loop system, and the particle swarm optimization (PSO) algorithm was introduced to determine the optimal control parameters. The improved closed-loop system was constructed in a triaxial SERF AM, achieving an average bandwidth of 410 Hz and a sensitivity of 10 fT/Hz1/2^{{1}/{2}}1/2in three axes, while ensuring consistent performance across the entire bandwidth. With the proposed method, the optimized control parameters can be obtained only by requiring the frequency response of the open-loop AM, which is convenient and useful for closed-loop AM applications.
Atomic magnetometers operated in spin-exchange relaxation-free (SERF) have the potential to replace superconducting quantum interference devices (SQUIDs) in the field of biomagnetism. Here, we demonstrate the dual-axis closed-loop control of a single-beam SERF magnetometer that allows sensing of two orthogonal magnetic fields simultaneously and independently with suppressed cross-talk effect, achieved by applying a rotating modulation field and using of the negative feedback. Operating in the dual-axis closed-loop mode with a miniature 4 × 4 × 4 mm 87Rb cell, we achieve magnetic field sensitivity of 20 fT/Hz1/2 and a bandwidth of 1.8 kHz. In addition to the experimental study of the sensitivity and bandwidth, we perform a theoretical analysis to the dual-axis response and develop an effective decoupling method. The implementation of closed-loop control enables the magnetometer to be robust against the disturbance of the ambient field, which could enlarge the dynamic range, enhance the systematic stability, and suppress the cross-talk effect. Such a simple, yet high-performance SERF magnetometer could be suitable as a promising candidate in the field of biomagnetism, allowing for a denser sensor array and opening up new possibilities for the noninvasive biomagnetic imaging.
Atomic spin sensors are essential for beyond-the-standard-model exploration, biomagnetic measurement, and quantum navigation. While the traditional DC mode spin-exchange relaxation-free (SERF) comagnetometer achieves ultrahigh sensitivity, further improvements require suppressing technical noise and surpassing standard quantum limit. In this work, we develop a K-Rb- 21 Ne SERF atomic comagnetometer that dynamically polarizes the electron and nuclear spins, shielding signals from direct interference by pump light. We establish a three-phase evolutionary model for hybrid spin ensemble dynamics, yielding a complete analytical solution, and analyze the responses to various spin perturbations. Additionally, we achieve an average 39% suppression of the polarization noise and identify the key factors that limit sensitivity improvements. The dynamically polarized comagnetometer exhibits effective suppression of technical noise and holds the potential to overcome quantum noise limit while offering promising applications in exploring new physics and precise magnetic field measurements.