Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2106.15310 · Applied Physics Letters

Submillimeter-resolution magnetic field imaging with digital micromirror device and atomic vapor cell

Chen Liu, Haifeng Dong, Junjun Sang

Published Sep 13, 2021• 17 citations
arXivHTMLPDF

Abstract

Magnetic field source localization and imaging happen at different scales. The sensing baseline ranges from meter scale, such as magnetic anomaly detection, to centimeter scale, such as brain field imaging, to nanometer scale, such as the imaging of a magnetic skyrmion and single cell. Here, we show how an atomic vapor cell can be used to realize a baseline of 109.6 μm with a magnetic sensitivity of 10 pT/Hz1/2 @0.6–100 Hz and a dynamic range of 2062–4124 nT. We used a free induction decay (FID) scheme to suppress low-frequency noise and avoid scale factor variation for different domains due to light non-uniformity. The measurement domains are scanned by a digital micromirror device. The currents of 22, 30, 38, and 44 mA are applied in the coils to generate different fields along the pumping axis, which are measured respectively by fitting the FID signals of the probe light. The residual fields of every domain are obtained from the intercept of linearly fitting of the measurement data corresponding to these four currents. The coil-generated fields are calculated by deducting the residual fields from the total fields. The results demonstrate that the hole of shield affects both the residual and the coil-generated field distribution. The potential impact of field distribution measurement with outstanding comprehensive properties of spatial resolution, sensitivity, and dynamic range is far-reaching. It could lead to capability of 3D magnetography for small things and/or organs in millimeter or even smaller scale.

DOI
10.1063/5.0061364

Related papers

Free-induction-decay magnetic field imaging with a microfabricated Cs vapor cell

Dominic Hunter, Christopher Perrella, Allan McWilliam +7 more

Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusion of Cs atoms in the presence of a nitrogen (N 2 ) buffer gas enables spatially independent measurements to be made within the same vapor cell by translating a 175 μ m diameter probe beam over the sensing area. For example, the OPM was used to record temporal and spatial information to reconstruct magnetic field distributions in one and two dimensions. The optimal magnetometer sensitivity was estimated to be 0.43 pT/Hz within a Nyquist limited bandwidth of 500 Hz. Furthermore, the sensor’s dynamic range exceeds the Earth’s field of approximately 50 μ T, which provides a framework for magnetic field imaging in unshielded environments.

arXiv:2303.10915•Optics Express•Sep 11, 2023•19 citations

Microscopic magnetic field imaging with hot atoms via single-pixel imaging

Cyril Torre, Jordan Brass, Sebastien Bisdee +3 more

In recent years, sensors based on hot atomic vapor cells have emerged as a compact and highly sensitive means of measuring magnetic fields. Such sensors have been deployed in the field for the measurement of, e.g., biological systems, representing a promising practical application of quantum technologies. However, it remains challenging to obtain high-resolution magnetic field images from these sensors, and in most cases, the spatial resolution of the system is limited by the sensor size. Here, we demonstrate the combination of single-pixel imaging (SPI) techniques with an atom vapor Faraday magnetometer to achieve microscopic magnetic field imaging. We demonstrate magnetic field imaging with a spatial resolution of ≈ 62.5 μm, limited only by the resolution of our digital micromirror device projection system and the absence of magnetic shielding in our experimental setup.

arXiv:2508.13869•Optics Express•Oct 27, 2025•1 citation

High spatial resolution multi-channel optically pumped atomic magnetometer based on a spatial light modulator

Xiujie Fang, Kai Wei, Tian Zhao +5 more

Ultra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz 1/2 with a spatial resolution of 216µm. Then, we measured the magnetic field distribution generated by a gradient coil and compared the experimentally obtained distributions with those calculated via finite element simulation. The obtained g value of 99.2% indicated good agreement between our experimental results and the theoretical calculations, thereby confirming that our proposed multi-channel SERF magnetometer was effective at measuring magnetic field distributions with an ultra-high spatial resolution.

Optics Express•Aug 14, 2020•48 citations

Magnetic Gradient Measurement Using Micro-Fabricated Shaped Rubidium Vapor Cell

Yu Ji, Jintang Shang, Jin Zhang +1 more

This paper presents a novel method to measure the magnetic gradient by an Mz atomic magnetometer using a micro-fabricated shaped rubidium vapor cell. The shaped vapor cell is fabricated by a chemical foaming process. Four micro radio frequency (RF) coils are mounted on the shaped rubidium vapor cell. Magnetic fields at the four points corresponding to the RF coils along the laser beam propagation are obtained by measuring Larmor frequency of the rubidium atoms inside the vapor cell. The magnetic gradients are also acquired with the measured magnetic fields. The measurement is performed in a magnetic shield environment. A dc electrical coil is taken to produce an existed magnetic field for the measurement and the theoretical magnetic field distribution is calculated. It is demonstrated that the measured magnetic fields and magnetic gradients correspond well with the calculated ones. Results show that the absolute error of the magnetic field is less than 0.1 μT, the relative error of the magnetic field is below 0.8%, and the relative error of the magnetic gradient is below 5.5%. Results also indicate that the atomic magnetometer has a sensitivity of 5 pT/Hz1/2from 1 to 2 Hz. The Mz atomic magnetometer is potentially useful for applications requiring gradient field information.

IEEE Transactions on Magnetics•May 30, 2019•13 citations

Optical pumping enhancement of a free-induction-decay magnetometer

Dominic Hunter, Marcin S. Mrozowski, Allan McWilliam +4 more

Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pumping with a magnetic field pulse that supersedes any transverse fields by over two orders of magnitude. The pulsed magnetic field is generated along the optical pumping axis using a compact electromagnetic coil pair encompassing a micro-electromechanical systems (MEMS) vapor cell. The coils also resistively heat the cesium vapor to the optimal atomic density without spurious magnetic field contributions as they are rapidly demagnetized to approximately zero field during spin readout. The demagnetization process is analyzed electronically, and directly with a FID measurement, to confirm that the residual magnetic field is minimal during detection. The sensitivity performance of this technique is compared to existing optical pumping modalities across a wide magnetic field range. A noise floor sensitivity of 238fT/Hz was achieved in a field of approximately 50 µT, in close agreement with the Cramér–Rao lower bound predicted noise density of 258fT/Hz.

arXiv:2307.11600•Journal of the Optical Society of America B•Sep 18, 2023•25 citations

Free-Induction-Decay Magnetometer Based on a Microfabricated Cs Vapor Cell

Dominic Hunter, S. Piccolomo, Jonathan D. Pritchard +3 more

Microfabricated atomic magnetometers are important for fundamental research and numerous applications, including geophysical surveying and biological imaging, as they provide a sensitive, accurate, and portable alternative to standard magnetic sensing. The strong scalability and all-optical nature of the free-induction-decay (FID) magnetometer also benefit applications requiring sensor networks. This study shows the advantages of applying synchronous modulation and differential polarimetric detection in an FID setting, for measuring picotesla-level fields using a miniaturized Cs vapor cell.

Physical Review Applied•Jul 5, 2018•70 citations
Magnetic field source localization and imaging happen at different scales. The sensing baseline ranges from meter scale, such as magnetic anomaly detection, to centimeter scale, such as brain field imaging, to nanometer scale, such as the imaging of a magnetic skyrmion and single cell. Here, we show how an atomic vapor cell can be used to realize a baseline of 109.6 μm with a magnetic sensitivity of 10 pT/Hz1/2 @0.6–100 Hz and a dynamic range of 2062–4124 nT. We used a free induction decay (FID) scheme to suppress low-frequency noise and avoid scale factor variation for different domains due to light non-uniformity. The measurement domains are scanned by a digital micromirror device. The currents of 22, 30, 38, and 44 mA are applied in the coils to generate different fields along the pumping axis, which are measured respectively by fitting the FID signals of the probe light. The residual fields of every domain are obtained from the intercept of linearly fitting of the measurement data corresponding to these four currents. The coil-generated fields are calculated by deducting the residual fields from the total fields. The results demonstrate that the hole of shield affects both the residual and the coil-generated field distribution. The potential impact of field distribution measurement with outstanding comprehensive properties of spatial resolution, sensitivity, and dynamic range is far-reaching. It could lead to capability of 3D magnetography for small things and/or organs in millimeter or even smaller scale.
Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusion of Cs atoms in the presence of a nitrogen (N 2 ) buffer gas enables spatially independent measurements to be made within the same vapor cell by translating a 175 μ m diameter probe beam over the sensing area. For example, the OPM was used to record temporal and spatial information to reconstruct magnetic field distributions in one and two dimensions. The optimal magnetometer sensitivity was estimated to be 0.43 pT/Hz within a Nyquist limited bandwidth of 500 Hz. Furthermore, the sensor’s dynamic range exceeds the Earth’s field of approximately 50 μ T, which provides a framework for magnetic field imaging in unshielded environments.
In recent years, sensors based on hot atomic vapor cells have emerged as a compact and highly sensitive means of measuring magnetic fields. Such sensors have been deployed in the field for the measurement of, e.g., biological systems, representing a promising practical application of quantum technologies. However, it remains challenging to obtain high-resolution magnetic field images from these sensors, and in most cases, the spatial resolution of the system is limited by the sensor size. Here, we demonstrate the combination of single-pixel imaging (SPI) techniques with an atom vapor Faraday magnetometer to achieve microscopic magnetic field imaging. We demonstrate magnetic field imaging with a spatial resolution of ≈ 62.5 μm, limited only by the resolution of our digital micromirror device projection system and the absence of magnetic shielding in our experimental setup.
Ultra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz 1/2 with a spatial resolution of 216µm. Then, we measured the magnetic field distribution generated by a gradient coil and compared the experimentally obtained distributions with those calculated via finite element simulation. The obtained g value of 99.2% indicated good agreement between our experimental results and the theoretical calculations, thereby confirming that our proposed multi-channel SERF magnetometer was effective at measuring magnetic field distributions with an ultra-high spatial resolution.
This paper presents a novel method to measure the magnetic gradient by an Mz atomic magnetometer using a micro-fabricated shaped rubidium vapor cell. The shaped vapor cell is fabricated by a chemical foaming process. Four micro radio frequency (RF) coils are mounted on the shaped rubidium vapor cell. Magnetic fields at the four points corresponding to the RF coils along the laser beam propagation are obtained by measuring Larmor frequency of the rubidium atoms inside the vapor cell. The magnetic gradients are also acquired with the measured magnetic fields. The measurement is performed in a magnetic shield environment. A dc electrical coil is taken to produce an existed magnetic field for the measurement and the theoretical magnetic field distribution is calculated. It is demonstrated that the measured magnetic fields and magnetic gradients correspond well with the calculated ones. Results show that the absolute error of the magnetic field is less than 0.1 μT, the relative error of the magnetic field is below 0.8%, and the relative error of the magnetic gradient is below 5.5%. Results also indicate that the atomic magnetometer has a sensitivity of 5 pT/Hz1/2from 1 to 2 Hz. The Mz atomic magnetometer is potentially useful for applications requiring gradient field information.
Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pumping with a magnetic field pulse that supersedes any transverse fields by over two orders of magnitude. The pulsed magnetic field is generated along the optical pumping axis using a compact electromagnetic coil pair encompassing a micro-electromechanical systems (MEMS) vapor cell. The coils also resistively heat the cesium vapor to the optimal atomic density without spurious magnetic field contributions as they are rapidly demagnetized to approximately zero field during spin readout. The demagnetization process is analyzed electronically, and directly with a FID measurement, to confirm that the residual magnetic field is minimal during detection. The sensitivity performance of this technique is compared to existing optical pumping modalities across a wide magnetic field range. A noise floor sensitivity of 238fT/Hz was achieved in a field of approximately 50 µT, in close agreement with the Cramér–Rao lower bound predicted noise density of 258fT/Hz.
Microfabricated atomic magnetometers are important for fundamental research and numerous applications, including geophysical surveying and biological imaging, as they provide a sensitive, accurate, and portable alternative to standard magnetic sensing. The strong scalability and all-optical nature of the free-induction-decay (FID) magnetometer also benefit applications requiring sensor networks. This study shows the advantages of applying synchronous modulation and differential polarimetric detection in an FID setting, for measuring picotesla-level fields using a miniaturized Cs vapor cell.