Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2307.11600 · Journal of the Optical Society of America B

Optical pumping enhancement of a free-induction-decay magnetometer

Dominic Hunter, Marcin S. Mrozowski, Allan McWilliam, Stuart J. Ingleby, T. Dyer, Paul F. Griffin, Erling Riis

Published Sep 18, 2023• 25 citations
arXivHTMLPDF

Abstract

Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pumping with a magnetic field pulse that supersedes any transverse fields by over two orders of magnitude. The pulsed magnetic field is generated along the optical pumping axis using a compact electromagnetic coil pair encompassing a micro-electromechanical systems (MEMS) vapor cell. The coils also resistively heat the cesium vapor to the optimal atomic density without spurious magnetic field contributions as they are rapidly demagnetized to approximately zero field during spin readout. The demagnetization process is analyzed electronically, and directly with a FID measurement, to confirm that the residual magnetic field is minimal during detection. The sensitivity performance of this technique is compared to existing optical pumping modalities across a wide magnetic field range. A noise floor sensitivity of 238fT/Hz was achieved in a field of approximately 50 µT, in close agreement with the Cramér–Rao lower bound predicted noise density of 258fT/Hz.

DOI
10.1364/josab.501086

Related papers

Free-induction-decay magnetometer based on synchronous optical pumping and RF pulse modulation

Jinghong Xu, Liwei Jiang, Junhao Liu +7 more

Free-induction-decay (FID) magnetometer is highly suitable for precise magnetic field sensing in unshielded environments with the benefit of exceptional accuracy and large dynamic range. The sensitivity of the FID magnetometer is directly influenced by the signal-to-noise ratio, making it critical to enhance the amplitude of the FID signal. In this study, we propose a FID magnetometer based on synchronous optical pumping and RF pulse modulation. A comprehensive theoretical description of the magnetometer is introduced, followed by simulation and experiment that compare the proposed modulation method with the synchronous optical pumping modulation method and the RF pulse modulation method. The results show that the synchronous optical pumping and RF pulse modulation achieves the enhancement of the FID signal and improves the magnetometer sensitivity. Furthermore, the dead zone of the magnetometer is reduced to the direction of the probe beam. This work is significant for further development of optically pumped magnetometers and provides a new scheme for their applications in unshielded environments.

EPJ Quantum Technology•May 30, 2025•11 citations

Dead-zone-free orientation-based pulsed atomic magnetometer

Jinghong Xu, Liwei Jiang, Yuntian Zou +6 more

The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.

Physical Review Research•Apr 6, 2026•1 citation

Free-induction-decay magnetic field imaging with a microfabricated Cs vapor cell

Dominic Hunter, Christopher Perrella, Allan McWilliam +7 more

Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusion of Cs atoms in the presence of a nitrogen (N 2 ) buffer gas enables spatially independent measurements to be made within the same vapor cell by translating a 175 μ m diameter probe beam over the sensing area. For example, the OPM was used to record temporal and spatial information to reconstruct magnetic field distributions in one and two dimensions. The optimal magnetometer sensitivity was estimated to be 0.43 pT/Hz within a Nyquist limited bandwidth of 500 Hz. Furthermore, the sensor’s dynamic range exceeds the Earth’s field of approximately 50 μ T, which provides a framework for magnetic field imaging in unshielded environments.

arXiv:2303.10915•Optics Express•Sep 11, 2023•19 citations

Free-induction-decay 4 He magnetometer using a multipass cell

Kaiwen Yi, Yang Liu, Bowen Wang +4 more

Optically pumped magnetometers (OPMs) based on the free-induction-decay (FID) configuration have recently attracted interest owing to their advantages, such as being calibration-free, easy to operate, and showing reduced light shifts induced by the pump light. Currently, alkali-metal vapor cells have been employed in most of the FID magnetometers. However, the relatively narrow linewidth of the magnetic resonance signal and nonlinear Zeeman (NLZ) effects generate bandwidth limitation and heading errors of these magnetometers in the Earth's field, respectively. In this work, we propose a ${}^{4}\mathrm{He}$-based FID magnetometer, which not only has the advantages of being NLZ-free and showing a high bandwidth, but also maintains an enhanced sensitivity assisted by a multipass cell. This magnetometer demonstrates a magnetic field noise floor of $0.34\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/{\mathrm{Hz}}^{1/2}$ with a Nyquist-limited bandwidth of $5$ kHz, which opens another route for atomic magnetometry using FID signals, and exhibits potential for applications in high-frequency magnetic field detection, such as biomagnetic measurements and magnetic communications in the geomagnetic field.

Physical Review Applied•Jul 31, 2024•26 citations

Free Induction Decay Optically Pumped Magnetometers: A Review

Jiarui Liu, Xiao Liu, Yuantian Lu +4 more

Free induction decay (FID) optically pumped magnetometers are among the most sensitive quantum sensors available for high-precision magnetic field measurements. This review summarizes recent advances in FID magnetometers, which represent a critical technological route that suppresses systematic errors by temporally separating atomic polarization from magnetic field detection. This review covers light-modulated optical pumping schemes (such as the Bell-Bloom mode), radio-frequency excitation schemes, and magnetic-field-enhanced pumping schemes. Key technological developments, including chip-scale MEMS fabrication, optical multipass architectures, advanced frequency estimation algorithms, and error suppression methods, are also discussed. Finally, emerging trends toward higher integration, environmental robustness, and intelligent signal demodulation are highlighted. These trends provide insights into the development of next-generation high-performance quantum sensors and their growing role in biomedical and geophysical applications, as well as in fundamental scientific research.

Sensors•Sep 26, 2026•0 citations

Laser mode-hopping assisted all-optical single beam pulsed atomic magnetometer

Yoon, Ji Hoon, Sang Hyuk Hong, Taek Jeong +3 more

We demonstrate an all-optical single beam pulsed atomic magnetometer assisted by laser mode-hopping in a distributed Bragg reflector (DBR) laser. We implement a temporal sequence of the laser current, with sinusoidal current modulation including the laser mode-hop current for synchronous optical pumping, and a following constant current for paramagnetic Faraday rotation measurements, to probe the free induction decay (FID) of transverse $^{87}$Rb spin polarization. Repetitive sudden frequency shifts of 20 GHz around the pressure-broadened $^{87}$Rb spectra, originating from laser mode-hopping, enable discontinuous optical pumping modulation with a large depth, which enhances transverse spin polarization. We achieved a sensitivity of 0.6 pT/Hz$^{1/2}$ in a magnetic field of 27 $μ$T, mainly limited by the photon-shot-noise and the magnetic field noise induced by the current noise in the current supply for driving the bias magnetic field coil. The Cramer-Rao lower bound (CRLB) of the sensitivity due to the non-magnetic noise such as photon shot-noise is 131 fT/Hz$^{1/2}$. Our approach based on laser mode-hopping can be applied for the miniaturization of all-optical atomic magnetometers with sub-pT/Hz$^{1/2}$ sensitivities.

arXiv:2404.01874•Apr 2, 2024•3 citations
Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pumping with a magnetic field pulse that supersedes any transverse fields by over two orders of magnitude. The pulsed magnetic field is generated along the optical pumping axis using a compact electromagnetic coil pair encompassing a micro-electromechanical systems (MEMS) vapor cell. The coils also resistively heat the cesium vapor to the optimal atomic density without spurious magnetic field contributions as they are rapidly demagnetized to approximately zero field during spin readout. The demagnetization process is analyzed electronically, and directly with a FID measurement, to confirm that the residual magnetic field is minimal during detection. The sensitivity performance of this technique is compared to existing optical pumping modalities across a wide magnetic field range. A noise floor sensitivity of 238fT/Hz was achieved in a field of approximately 50 µT, in close agreement with the Cramér–Rao lower bound predicted noise density of 258fT/Hz.
Free-induction-decay (FID) magnetometer is highly suitable for precise magnetic field sensing in unshielded environments with the benefit of exceptional accuracy and large dynamic range. The sensitivity of the FID magnetometer is directly influenced by the signal-to-noise ratio, making it critical to enhance the amplitude of the FID signal. In this study, we propose a FID magnetometer based on synchronous optical pumping and RF pulse modulation. A comprehensive theoretical description of the magnetometer is introduced, followed by simulation and experiment that compare the proposed modulation method with the synchronous optical pumping modulation method and the RF pulse modulation method. The results show that the synchronous optical pumping and RF pulse modulation achieves the enhancement of the FID signal and improves the magnetometer sensitivity. Furthermore, the dead zone of the magnetometer is reduced to the direction of the probe beam. This work is significant for further development of optically pumped magnetometers and provides a new scheme for their applications in unshielded environments.
The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.
Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusion of Cs atoms in the presence of a nitrogen (N 2 ) buffer gas enables spatially independent measurements to be made within the same vapor cell by translating a 175 μ m diameter probe beam over the sensing area. For example, the OPM was used to record temporal and spatial information to reconstruct magnetic field distributions in one and two dimensions. The optimal magnetometer sensitivity was estimated to be 0.43 pT/Hz within a Nyquist limited bandwidth of 500 Hz. Furthermore, the sensor’s dynamic range exceeds the Earth’s field of approximately 50 μ T, which provides a framework for magnetic field imaging in unshielded environments.
Optically pumped magnetometers (OPMs) based on the free-induction-decay (FID) configuration have recently attracted interest owing to their advantages, such as being calibration-free, easy to operate, and showing reduced light shifts induced by the pump light. Currently, alkali-metal vapor cells have been employed in most of the FID magnetometers. However, the relatively narrow linewidth of the magnetic resonance signal and nonlinear Zeeman (NLZ) effects generate bandwidth limitation and heading errors of these magnetometers in the Earth's field, respectively. In this work, we propose a 4He{}^{4}\mathrm{He}4He-based FID magnetometer, which not only has the advantages of being NLZ-free and showing a high bandwidth, but also maintains an enhanced sensitivity assisted by a multipass cell. This magnetometer demonstrates a magnetic field noise floor of 0.34pT/Hz1/20.34\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/{\mathrm{Hz}}^{1/2}0.34pT/Hz1/2 with a Nyquist-limited bandwidth of 555 kHz, which opens another route for atomic magnetometry using FID signals, and exhibits potential for applications in high-frequency magnetic field detection, such as biomagnetic measurements and magnetic communications in the geomagnetic field.
Free induction decay (FID) optically pumped magnetometers are among the most sensitive quantum sensors available for high-precision magnetic field measurements. This review summarizes recent advances in FID magnetometers, which represent a critical technological route that suppresses systematic errors by temporally separating atomic polarization from magnetic field detection. This review covers light-modulated optical pumping schemes (such as the Bell-Bloom mode), radio-frequency excitation schemes, and magnetic-field-enhanced pumping schemes. Key technological developments, including chip-scale MEMS fabrication, optical multipass architectures, advanced frequency estimation algorithms, and error suppression methods, are also discussed. Finally, emerging trends toward higher integration, environmental robustness, and intelligent signal demodulation are highlighted. These trends provide insights into the development of next-generation high-performance quantum sensors and their growing role in biomedical and geophysical applications, as well as in fundamental scientific research.
We demonstrate an all-optical single beam pulsed atomic magnetometer assisted by laser mode-hopping in a distributed Bragg reflector (DBR) laser. We implement a temporal sequence of the laser current, with sinusoidal current modulation including the laser mode-hop current for synchronous optical pumping, and a following constant current for paramagnetic Faraday rotation measurements, to probe the free induction decay (FID) of transverse 87^{87}87Rb spin polarization. Repetitive sudden frequency shifts of 20 GHz around the pressure-broadened 87^{87}87Rb spectra, originating from laser mode-hopping, enable discontinuous optical pumping modulation with a large depth, which enhances transverse spin polarization. We achieved a sensitivity of 0.6 pT/Hz1/2^{1/2}1/2 in a magnetic field of 27 μμμT, mainly limited by the photon-shot-noise and the magnetic field noise induced by the current noise in the current supply for driving the bias magnetic field coil. The Cramer-Rao lower bound (CRLB) of the sensitivity due to the non-magnetic noise such as photon shot-noise is 131 fT/Hz1/2^{1/2}1/2. Our approach based on laser mode-hopping can be applied for the miniaturization of all-optical atomic magnetometers with sub-pT/Hz1/2^{1/2}1/2 sensitivities.