Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2011.07560 · Physical review. D/Physical review. D.

Weak value amplification in high energy physics: A case study for precision measurement of CP violation in B meson decays

S. Higashino, Yuichiro Mori, Y. Takubo, T. Higuchi, A. Ishikawa, Izumi Tsutsui

Published Aug 9, 2021• 3 citations
arXivHTMLPDF

Abstract

The technique of weak value amplification, proposed by Aharonov et al. in 1988, has been applied for various fields of physics for the purpose of precision measurement, which is made possible by exploiting the freedom of ``postselection'' specifying actively the final state in the physical process. Here we report the feasibility of utilizing the technique of weak value amplification in high-energy particle physics, especially in measuring the $CP$-violating parameters in $B$ meson decays, where the effective lifetime of the decay mode is expected to be prolonged statistically due to the postselection. Our analysis shows that, when adopted in the Belle II experiment at the SuperKEKB collider, the effective lifetime may be prolonged up to 2.6 times, and that the measurement precision of the $CP$-violating parameters will also be improved by its effect.

DOI
10.1103/physrevd.104.033001

Related papers

Weak-value amplification and the lifetime of a decaying particle

Yuichiro Mori, Izumi Tsutsui

We study the possibility of varying the measured lifetime of a decaying particle based on the technique of weak value amplification in which an additional filtering process called postselection is performed. Our analysis made in a direct measurement scheme presented here shows that, for simple two-level systems, the lifetime may be prolonged more than three times compared to the original one, while it can also be shortened arbitrarily by a proper choice of postselection. This result is consistent with our previous analysis on the possible prolongation of the lifetime of $B$ mesons that may be observed in laboratories, and suggests room for novel applications of weak-value amplification beyond precision measurement conventionally considered.

arXiv:2105.12349•Physical Review A•Sep 1, 2021•3 citations

Optimization of parameter measurement precision with precoupling-assisted weak-value amplification

Manchao Zhang, Jie Zhang, Chun-Wang Wu +4 more

The weak-value amplification is extensively considered in precision metrology in order to achieve a higher sensitivity. Despite the practical benefits in amplifying small physical quantities, its metrological advantage still arouses a broad debate due to the low postselection probability of success. In this paper, by employing the quantum Fisher information metric, we show that the precision of estimating an unknown parameter can be improved by introducing a precoupling process with properly chosen interaction operators. We point out this result is credible for both real and imaginary weak values. By tracking the meter wave functions, we find this enhancement of estimation precision comes from a precoupling induced modulation of the meter wave function, thus the most sensitive regime with respect to the parameter is reached. In addition, the estimation error is investigated by considering the difference between the theoretical and estimated value. The analysis suggests that this kind of error can be effectively suppressed by averaging the estimations resulted from different initial meter states. These results are finally illustrated by an exact numerical simulation where the advantages of our proposal are displayed by the comparison to the standard weak-value amplification scheme.

Physical Review A•Apr 3, 2023•5 citations

On the validity of weak measurement applied for precision measurement

Yuichiro Mori, Jaeha Lee, Izumi Tsutsui

Abstract We present a general framework of examining the validity of weak measurement—the standard procedure to acquire Aharonov’s weak value—which has been used intensively in recent years for precision measurement, exploiting the amplification mechanism available for the weak value. Our framework allows one to deal systematically with various causes of uncertainties intrinsic to the actual measurement process as well as those found in the theoretical analysis employed to describe the system. Using our framework, we examine in detail the two seminal experiments, Hosten’s detection measurement of the spin Hall effect of light [Hosten and Kwiat 2008 Science 319 787] and Dixon’s ultra sensitive beam deflection measurement [Dixon et al 2009 Phys. Rev. Lett. 102 173601]. Our analysis shows that their results are well within the range of amplification (actually in the vicinity of the optimal point) where the weak measurements are valid. This suggests that our framework is both practical and sound, and may be useful to determine beforehand the possible extent of amplification in the future weak measurement experiments.

arXiv:1901.06831•Journal of Physics B Atomic Molecular and Optical Physics•Oct 28, 2019•10 citations

精密測定への弱値増幅の応用可能性について

Yuichiro Mori

The novel notion of a physical quantity called 'weak value', which was proposed by Aharonov et al. in 1988, has attracted much attention in the fields of quantum foundations and quantum measurement.In particular, the fact that through proper state selections the weak value can be made arbitrarily large, exceeding the conventional bound set by the maximum eigenvalue of the physical observable, has been widely regarded as a promising source for precision measurement.Indeed, in recent years we have seen increasingly many reports of successful applications of the weak value in photonic systems with various instances of observables amplified effectively.However, it has also been recognized that there are two major obstacles in realizing this weak value amplification (WVA).First, it is unclear under what conditions the WVA becomes effective due to the conflict between the ambiguity caused by the state selections and the amplification effect.Second, the required state selections may not be available depending on the systems one is dealing with.In order to expand the applicability of the WVA, one must solve these problems properly.In this dissertation, we first review the basics of precision measurement and the WVA and then present our method of evaluation for the WVA considering the measurement uncertainty including the ambiguity of the WVA.We applied our method of evaluation for the two celebrated experiments to confirm the basic validity of the results of the two experiments.In addition, as a new application of the WVA, we consider the time evolution of unstable particles to find that the decay time distribution is generally characterized by the weak value of the Hamiltonian and that the state selections can indeed be performed by measuring the particles produced during the decay.Our result indicates that the WVA may also be applicable to the system of unstable particles.

•Mar 19, 2021•0 citations

Toward ultrahigh sensitivity in weak-value amplification

Jingzheng Huang, Yanjia Li, Chen Fang +2 more

Achieving higher sensitivity is an earnest purpose for precision metrology. As a response to this goal, the weak-value amplification approach has been developed for measuring ultrasmall physical effects, realizing sensitivity that had never been reached before. Encouraged by the successes, many efforts have been devoted to obtain ultimate sensitivity of weak-value amplification. However, the benefit would be easily compromised in practice, because the cost of significant reduction on signal intensity leads to an ultralow signal-to-noise ratio. In this work, we bridge this gap by proposing an alternative weak-value amplification approach, which provides sensitivity several orders of magnitude higher than the standard approach while being compatible with practical imperfections. In the proof-of-principle experiment of measuring longitudinal phase change in time domain, sensitivity up to $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ attosecond is exemplified. Our approach can be applied to measure other small parameters with extremely high sensitivity, providing a method for future precision metrology.

arXiv:1907.02168•Physical Review A•Jul 11, 2019•40 citations

Weak value and measurement in precision sensing

Junfan Zhu, Ling Ye, Yifan Wang +5 more

Weak measurement refers to a type of quantum measurement that disturbs the system very little. In the framework of weak measurement, Aharonov, Albert, and Vaidman introduced the concept of postselection and thereby defined the weak value. In recent research, weak-value measurement (WVM) has offered a novel perspective for studying intricate problems in quantum mechanics, leading to many conceptual breakthroughs. More importantly in practice, WVM has shown an unprecedented impact on precision sensing. In this review, we begin by presenting the fundamental theory of WVM based on quantum parameter estimation, from which the effects of weak-value amplification and weak-coupling amplification can be derived. The two effects can significantly improve the precision in various sensing schemes based on WVM. We point out the technical advantages that enable the WVM schemes to outperform the conventional ones under the same measurement conditions. Notably, the capability of information compression is underscored, which is garnering increasing attention in the field of quantum metrology. This review aims to show the possibility for broadening the application of WVM to address more critical problems, and on the other hand, for leveraging its advantages to accomplish tasks that are currently unattainable, such that WVM could play a more important role in the future of precision sensing.

Applied Physics Reviews•May 6, 2025•16 citations
The technique of weak value amplification, proposed by Aharonov et al. in 1988, has been applied for various fields of physics for the purpose of precision measurement, which is made possible by exploiting the freedom of ``postselection'' specifying actively the final state in the physical process. Here we report the feasibility of utilizing the technique of weak value amplification in high-energy particle physics, especially in measuring the CPCPCP-violating parameters in BBB meson decays, where the effective lifetime of the decay mode is expected to be prolonged statistically due to the postselection. Our analysis shows that, when adopted in the Belle II experiment at the SuperKEKB collider, the effective lifetime may be prolonged up to 2.6 times, and that the measurement precision of the CPCPCP-violating parameters will also be improved by its effect.
We study the possibility of varying the measured lifetime of a decaying particle based on the technique of weak value amplification in which an additional filtering process called postselection is performed. Our analysis made in a direct measurement scheme presented here shows that, for simple two-level systems, the lifetime may be prolonged more than three times compared to the original one, while it can also be shortened arbitrarily by a proper choice of postselection. This result is consistent with our previous analysis on the possible prolongation of the lifetime of BBB mesons that may be observed in laboratories, and suggests room for novel applications of weak-value amplification beyond precision measurement conventionally considered.
The weak-value amplification is extensively considered in precision metrology in order to achieve a higher sensitivity. Despite the practical benefits in amplifying small physical quantities, its metrological advantage still arouses a broad debate due to the low postselection probability of success. In this paper, by employing the quantum Fisher information metric, we show that the precision of estimating an unknown parameter can be improved by introducing a precoupling process with properly chosen interaction operators. We point out this result is credible for both real and imaginary weak values. By tracking the meter wave functions, we find this enhancement of estimation precision comes from a precoupling induced modulation of the meter wave function, thus the most sensitive regime with respect to the parameter is reached. In addition, the estimation error is investigated by considering the difference between the theoretical and estimated value. The analysis suggests that this kind of error can be effectively suppressed by averaging the estimations resulted from different initial meter states. These results are finally illustrated by an exact numerical simulation where the advantages of our proposal are displayed by the comparison to the standard weak-value amplification scheme.
Abstract We present a general framework of examining the validity of weak measurement—the standard procedure to acquire Aharonov’s weak value—which has been used intensively in recent years for precision measurement, exploiting the amplification mechanism available for the weak value. Our framework allows one to deal systematically with various causes of uncertainties intrinsic to the actual measurement process as well as those found in the theoretical analysis employed to describe the system. Using our framework, we examine in detail the two seminal experiments, Hosten’s detection measurement of the spin Hall effect of light [Hosten and Kwiat 2008 Science 319 787] and Dixon’s ultra sensitive beam deflection measurement [Dixon et al 2009 Phys. Rev. Lett. 102 173601]. Our analysis shows that their results are well within the range of amplification (actually in the vicinity of the optimal point) where the weak measurements are valid. This suggests that our framework is both practical and sound, and may be useful to determine beforehand the possible extent of amplification in the future weak measurement experiments.
The novel notion of a physical quantity called 'weak value', which was proposed by Aharonov et al. in 1988, has attracted much attention in the fields of quantum foundations and quantum measurement.In particular, the fact that through proper state selections the weak value can be made arbitrarily large, exceeding the conventional bound set by the maximum eigenvalue of the physical observable, has been widely regarded as a promising source for precision measurement.Indeed, in recent years we have seen increasingly many reports of successful applications of the weak value in photonic systems with various instances of observables amplified effectively.However, it has also been recognized that there are two major obstacles in realizing this weak value amplification (WVA).First, it is unclear under what conditions the WVA becomes effective due to the conflict between the ambiguity caused by the state selections and the amplification effect.Second, the required state selections may not be available depending on the systems one is dealing with.In order to expand the applicability of the WVA, one must solve these problems properly.In this dissertation, we first review the basics of precision measurement and the WVA and then present our method of evaluation for the WVA considering the measurement uncertainty including the ambiguity of the WVA.We applied our method of evaluation for the two celebrated experiments to confirm the basic validity of the results of the two experiments.In addition, as a new application of the WVA, we consider the time evolution of unstable particles to find that the decay time distribution is generally characterized by the weak value of the Hamiltonian and that the state selections can indeed be performed by measuring the particles produced during the decay.Our result indicates that the WVA may also be applicable to the system of unstable particles.
Achieving higher sensitivity is an earnest purpose for precision metrology. As a response to this goal, the weak-value amplification approach has been developed for measuring ultrasmall physical effects, realizing sensitivity that had never been reached before. Encouraged by the successes, many efforts have been devoted to obtain ultimate sensitivity of weak-value amplification. However, the benefit would be easily compromised in practice, because the cost of significant reduction on signal intensity leads to an ultralow signal-to-noise ratio. In this work, we bridge this gap by proposing an alternative weak-value amplification approach, which provides sensitivity several orders of magnitude higher than the standard approach while being compatible with practical imperfections. In the proof-of-principle experiment of measuring longitudinal phase change in time domain, sensitivity up to $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ attosecond is exemplified. Our approach can be applied to measure other small parameters with extremely high sensitivity, providing a method for future precision metrology.
Weak measurement refers to a type of quantum measurement that disturbs the system very little. In the framework of weak measurement, Aharonov, Albert, and Vaidman introduced the concept of postselection and thereby defined the weak value. In recent research, weak-value measurement (WVM) has offered a novel perspective for studying intricate problems in quantum mechanics, leading to many conceptual breakthroughs. More importantly in practice, WVM has shown an unprecedented impact on precision sensing. In this review, we begin by presenting the fundamental theory of WVM based on quantum parameter estimation, from which the effects of weak-value amplification and weak-coupling amplification can be derived. The two effects can significantly improve the precision in various sensing schemes based on WVM. We point out the technical advantages that enable the WVM schemes to outperform the conventional ones under the same measurement conditions. Notably, the capability of information compression is underscored, which is garnering increasing attention in the field of quantum metrology. This review aims to show the possibility for broadening the application of WVM to address more critical problems, and on the other hand, for leveraging its advantages to accomplish tasks that are currently unattainable, such that WVM could play a more important role in the future of precision sensing.