Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2010.05828 · Entropy

Shortcut-to-Adiabaticity-Like Techniques for Parameter Estimation in Quantum Metrology

Marina Cabedo-Olaya, Juan Gonzalo Muga, Sofía Martínez-Garaot

Published Nov 3, 2020• 9 citations
arXivHTMLPDF

Abstract

Quantum metrology makes use of quantum mechanics to improve precision measurements and measurement sensitivities. It is usually formulated for time-independent Hamiltonians, but time-dependent Hamiltonians may offer advantages, such as a T4 time dependence of the Fisher information which cannot be reached with a time-independent Hamiltonian. In Optimal adaptive control for quantum metrology with time-dependent Hamiltonians (Nature Communications 8, 2017), Shengshi Pang and Andrew N. Jordan put forward a Shortcut-to-adiabaticity (STA)-like method, specifically an approach formally similar to the “counterdiabatic approach”, adding a control term to the original Hamiltonian to reach the upper bound of the Fisher information. We revisit this work from the point of view of STA to set the relations and differences between STA-like methods in metrology and ordinary STA. This analysis paves the way for the application of other STA-like techniques in parameter estimation. In particular we explore the use of physical unitary transformations to propose alternative time-dependent Hamiltonians which may be easier to implement in the laboratory.

DOI
10.3390/e22111251

Related papers

Optimal adaptive control for quantum metrology with time-dependent Hamiltonians

Shengshi Pang, Andrew N. Jordan

Abstract Quantum metrology has been studied for a wide range of systems with time-independent Hamiltonians. For systems with time-dependent Hamiltonians, however, due to the complexity of dynamics, little has been known about quantum metrology. Here we investigate quantum metrology with time-dependent Hamiltonians to bridge this gap. We obtain the optimal quantum Fisher information for parameters in time-dependent Hamiltonians, and show proper Hamiltonian control is generally necessary to optimize the Fisher information. We derive the optimal Hamiltonian control, which is generally adaptive, and the measurement scheme to attain the optimal Fisher information. In a minimal example of a qubit in a rotating magnetic field, we find a surprising result that the fundamental limit of T2 time scaling of quantum Fisher information can be broken with time-dependent Hamiltonians, which reaches T4 in estimating the rotation frequency of the field. We conclude by considering level crossings in the derivatives of the Hamiltonians, and point out additional control is necessary for that case.

arXiv:1606.02166•Nature Communications•Mar 9, 2017•205 citations

Adiabatic critical quantum metrology cannot reach the Heisenberg limit even when shortcuts to adiabaticity are applied

Karol Gietka, Friederike Metz, Tim Keller +1 more

We show that the quantum Fisher information attained in an adiabatic approach to critical quantum metrology cannot lead to the Heisenberg limit of precision and therefore regular quantum metrology under optimal settings is always superior. Furthermore, we argue that even though shortcuts to adiabaticity can arbitrarily decrease the time of preparing critical ground states, they cannot be used to achieve or overcome the Heisenberg limit for quantum parameter estimation in adiabatic critical quantum metrology. As case studies, we explore the application of counter-diabatic driving to the Landau-Zener model and the quantum Rabi model.

arXiv:2103.12939•Quantum•Jul 1, 2021•48 citations

Enhancing sensitivity in quantum metrology by Hamiltonian extensions

Julien Mathieu Elias Fraïsse, Daniel Braun

A well-studied scenario in quantum parameter estimation theory arises when the parameter to be estimated is imprinted on the initial state by a Hamiltonian of the form $\ensuremath{\theta}G$. For such ``phase-shift Hamiltonians'' it has been shown that one cannot improve the channel quantum Fisher information by adding ancillas and letting the system interact with them. Here we investigate the general case, where the Hamiltonian is not necessarily a phase shift, and show that in this case in general it $\mathit{is}$ possible to increase the quantum channel information and to reach an upper bound. This can be done by adding a term proportional to the derivative of the Hamiltonian, or by subtracting a term from the original Hamiltonian. Neither method makes use of any ancillas, which shows that, for quantum channel estimation with an arbitrary parameter-dependent Hamiltonian, entanglement with an ancillary system is not necessary to reach the best possible sensitivity. By adding an operator to the Hamiltonian we can also modify the time scaling of the channel quantum Fisher information. We illustrate our techniques with nitrogen vacancy center magnetometry and the estimation of the direction of a magnetic field in a given plane using a single spin-1 as probe.

arXiv:1703.03476•Physical Review A•Jun 29, 2017•16 citations

Shortcuts to adiabaticity: Concepts, methods, and applications

David Guéry-Odelin, A. Ruschhaupt, Anthony Kiely +3 more

Adiabatic evolution along the instantaneous eigenstate of a time-dependent Hamiltonian is used for robust and high fidelity state transfer in atomic and molecular physics. Shortcuts to adiabaticity (STA) are systematic approaches to accomplish the same final state transfer in a faster manner. This article presents an introduction to STA and reviews different theoretical approaches and applications of STA to a range of scientific and engineering tasks in quantum physics and beyond.

arXiv:1904.08448•Reviews of Modern Physics•Oct 24, 2019•1,106 citations

Quantum metrology for a general Hamiltonian parameter

Shengshi Pang, Todd A. Brun

Quantum metrology enhances the sensitivity of parameter estimation using the distinctive resources of quantum mechanics such as entanglement. It has been shown that the precision of estimating an overall multiplicative factor of a Hamiltonian can be increased to exceed the classical limit, yet little is known about estimating a general Hamiltonian parameter. In this paper, we study this problem in detail. We find that the scaling of the estimation precision with the number of systems can always be optimized to the Heisenberg limit, while the time scaling can be quite different from that of estimating an overall multiplicative factor. We derive the generator of local parameter translation on the unitary evolution operator of the Hamiltonian, and use it to evaluate the estimation precision of the parameter and establish a general upper bound on the quantum Fisher information. The results indicate that the quantum Fisher information generally can be divided into two parts: one is quadratic in time, while the other oscillates with time. When the eigenvalues of the Hamiltonian do not depend on the parameter, the quadratic term vanishes, and the quantum Fisher information will be bounded in this case. To illustrate the results, we give an example of estimating a parameter of a magnetic field by measuring a spin-$\frac{1}{2}$ particle and compare the results for estimating the amplitude and the direction of the magnetic field.

arXiv:1407.6091•Physical Review A•Aug 25, 2014•181 citations

A First-Principles Thermodynamic Uncertainty Relation for Shortcuts to Adiabaticity

Guillermo Perna, Federico Centrone, Esteban Calzetta

We study the fundamental limitations of implementing time-dependent Hamiltonian protocols when ''time'' is provided by a quantum clock rather than an external classical parameter. For a parametric harmonic oscillator controlled through a shortcut-to-adiabaticity (STA) schedule and coupled to a minimal clock degree of freedom, tracing out the clock yields an effective reduced dynamics that is a mixture of unitary Gaussian trajectories. Within a noise-dominated regime, we compute the energetic deviation from the target STA outcome and its fluctuations, together with the fidelity to the target evolution and the purity loss of the reduced state, for vacuum and coherent initial states. Combining these observables produces a thermodynamic-uncertainty-type tradeoff that links achievable precision to an irreducible loss of purity set by the clock precision and the protocol sensitivity.

quant-pharXiv:2603.11236•Entropy•Mar 13, 2026•0 citations
Quantum metrology makes use of quantum mechanics to improve precision measurements and measurement sensitivities. It is usually formulated for time-independent Hamiltonians, but time-dependent Hamiltonians may offer advantages, such as a T4 time dependence of the Fisher information which cannot be reached with a time-independent Hamiltonian. In Optimal adaptive control for quantum metrology with time-dependent Hamiltonians (Nature Communications 8, 2017), Shengshi Pang and Andrew N. Jordan put forward a Shortcut-to-adiabaticity (STA)-like method, specifically an approach formally similar to the “counterdiabatic approach”, adding a control term to the original Hamiltonian to reach the upper bound of the Fisher information. We revisit this work from the point of view of STA to set the relations and differences between STA-like methods in metrology and ordinary STA. This analysis paves the way for the application of other STA-like techniques in parameter estimation. In particular we explore the use of physical unitary transformations to propose alternative time-dependent Hamiltonians which may be easier to implement in the laboratory.
Abstract Quantum metrology has been studied for a wide range of systems with time-independent Hamiltonians. For systems with time-dependent Hamiltonians, however, due to the complexity of dynamics, little has been known about quantum metrology. Here we investigate quantum metrology with time-dependent Hamiltonians to bridge this gap. We obtain the optimal quantum Fisher information for parameters in time-dependent Hamiltonians, and show proper Hamiltonian control is generally necessary to optimize the Fisher information. We derive the optimal Hamiltonian control, which is generally adaptive, and the measurement scheme to attain the optimal Fisher information. In a minimal example of a qubit in a rotating magnetic field, we find a surprising result that the fundamental limit of T2 time scaling of quantum Fisher information can be broken with time-dependent Hamiltonians, which reaches T4 in estimating the rotation frequency of the field. We conclude by considering level crossings in the derivatives of the Hamiltonians, and point out additional control is necessary for that case.
We show that the quantum Fisher information attained in an adiabatic approach to critical quantum metrology cannot lead to the Heisenberg limit of precision and therefore regular quantum metrology under optimal settings is always superior. Furthermore, we argue that even though shortcuts to adiabaticity can arbitrarily decrease the time of preparing critical ground states, they cannot be used to achieve or overcome the Heisenberg limit for quantum parameter estimation in adiabatic critical quantum metrology. As case studies, we explore the application of counter-diabatic driving to the Landau-Zener model and the quantum Rabi model.
A well-studied scenario in quantum parameter estimation theory arises when the parameter to be estimated is imprinted on the initial state by a Hamiltonian of the form $\ensuremath{\theta}G$. For such ``phase-shift Hamiltonians'' it has been shown that one cannot improve the channel quantum Fisher information by adding ancillas and letting the system interact with them. Here we investigate the general case, where the Hamiltonian is not necessarily a phase shift, and show that in this case in general it is\mathit{is}is possible to increase the quantum channel information and to reach an upper bound. This can be done by adding a term proportional to the derivative of the Hamiltonian, or by subtracting a term from the original Hamiltonian. Neither method makes use of any ancillas, which shows that, for quantum channel estimation with an arbitrary parameter-dependent Hamiltonian, entanglement with an ancillary system is not necessary to reach the best possible sensitivity. By adding an operator to the Hamiltonian we can also modify the time scaling of the channel quantum Fisher information. We illustrate our techniques with nitrogen vacancy center magnetometry and the estimation of the direction of a magnetic field in a given plane using a single spin-1 as probe.
Quantum metrology enhances the sensitivity of parameter estimation using the distinctive resources of quantum mechanics such as entanglement. It has been shown that the precision of estimating an overall multiplicative factor of a Hamiltonian can be increased to exceed the classical limit, yet little is known about estimating a general Hamiltonian parameter. In this paper, we study this problem in detail. We find that the scaling of the estimation precision with the number of systems can always be optimized to the Heisenberg limit, while the time scaling can be quite different from that of estimating an overall multiplicative factor. We derive the generator of local parameter translation on the unitary evolution operator of the Hamiltonian, and use it to evaluate the estimation precision of the parameter and establish a general upper bound on the quantum Fisher information. The results indicate that the quantum Fisher information generally can be divided into two parts: one is quadratic in time, while the other oscillates with time. When the eigenvalues of the Hamiltonian do not depend on the parameter, the quadratic term vanishes, and the quantum Fisher information will be bounded in this case. To illustrate the results, we give an example of estimating a parameter of a magnetic field by measuring a spin-12\frac{1}{2}21​ particle and compare the results for estimating the amplitude and the direction of the magnetic field.
We study the fundamental limitations of implementing time-dependent Hamiltonian protocols when ''time'' is provided by a quantum clock rather than an external classical parameter. For a parametric harmonic oscillator controlled through a shortcut-to-adiabaticity (STA) schedule and coupled to a minimal clock degree of freedom, tracing out the clock yields an effective reduced dynamics that is a mixture of unitary Gaussian trajectories. Within a noise-dominated regime, we compute the energetic deviation from the target STA outcome and its fluctuations, together with the fidelity to the target evolution and the purity loss of the reduced state, for vacuum and coherent initial states. Combining these observables produces a thermodynamic-uncertainty-type tradeoff that links achievable precision to an irreducible loss of purity set by the clock precision and the protocol sensitivity.