arXiv:2009.03010 · Review of Scientific Instruments

Characterizing cryogenic amplifiers with a matched temperature-variable noise source

Slawomir Simbierowicz, Visa Vesterinen, Joshua Milem, Aleksi Lintunen, Mika Oksanen, Leif Roschier, Leif Grönberg, Juha Hassel, David Gunnarsson, Russell E. Lake

Published Mar 1, 2021• 47 citations
arXivHTMLPDF

Abstract

We present a cryogenic microwave noise source with a characteristic impedance of 50 Ω, which can be installed in a coaxial line of a cryostat. The bath temperature of the noise source is continuously variable between 0.1 K and 5 K without causing significant back-action heating on the sample space. As a proof-of-concept experiment, we perform Y-factor measurements of an amplifier cascade that includes a traveling wave parametric amplifier and a commercial high electron mobility transistor amplifier. We observe system noise temperatures as low as 680−200+20 mK at 5.7 GHz corresponding to 1.5−0.7+0.1 excess photons. The system we present has immediate applications in the validation of solid-state qubit readout lines.

DOI
10.1063/5.0028951

Related papers

Low-noise cryogenic microwave amplifier characterization with a calibrated noise source

M. Malnou, Trevyn F. Q. Larson, John D. Teufel +2 more

Parametric amplifiers have become a workhorse in superconducting quantum computing; however, research and development of these devices has been hampered by inconsistent and, sometimes, misleading noise performance characterization methodologies. The concepts behind noise characterization are deceptively simple, and there are many places where one can make mistakes, either in measurement or in interpretation and analysis. In this article, we cover the basics of noise performance characterization and the special problems it presents in parametric amplifiers with limited power handling capability. We illustrate the issues with three specific examples: a high-electron mobility transistor amplifier, a Josephson traveling-wave parametric amplifier, and a Josephson parametric amplifier. We emphasize the use of a 50-Ω shot noise tunnel junction (SNTJ) as a broadband noise source, demonstrating its utility for cryogenic amplifier amplifications. These practical examples highlight the role of loss as well as the additional parametric amplifier "idler" input mode.

arXiv:2312.14900•Review of Scientific Instruments•Mar 1, 2024•21 citations

In situ calibration of microwave attenuation and gain using a cryogenic on-chip attenuator

Thomas Descamps, Linus Andersson, Vittorio Buccheri +3 more

Accurate in situ calibration of microwave attenuation and amplification-chain noise is essential for superconducting quantum circuits. We demonstrate a compact, self-calibrating cryogenic noise source based on an on-chip chromium attenuator that can be resistively heated with nanowatt-level power and directly integrated into a coaxial microwave line at the mixing-chamber stage. By comparing Johnson-Nyquist noise generated by Joule and microwave heating, measured through the amplification chain, the attenuation of the input line, and hence the gain of the chain, is determined without requiring knowledge of the attenuator temperature. The device exhibits millisecond-scale response times and negligible heating of the cryostat base plate. Using this approach, we determine the gain and added noise of a cryogenic amplification chain over the 4-8 GHz band. Our results provide a simple and accurate method to characterize near-quantum-limited parametric amplifiers used in superconducting-qubit readout.

quant-pharXiv:2602.16889•Feb 20, 2026•1 citation

A wideband cryogenic microwave low-noise amplifier

Boris I Ivanov, Dmitry I. Volkhin, Ilya L. Novikov +5 more

A broadband low-noise four-stage high-electron-mobility transistor amplifier was designed and characterized in a cryogen-free dilution refrigerator at the 3.8 K temperature stage. The obtained power dissipation of the amplifier is below 20 mW. In the frequency range from 6 to 12 GHz its gain exceeds 30 dB. The equivalent noise temperature of the amplifier is below 6 K for the presented frequency range. The amplifier is applicable for any type of cryogenic microwave measurements. As an example we demonstrate here the characterization of the superconducting X-mon qubit coupled to an on-chip coplanar waveguide resonator.

Beilstein Journal of Nanotechnology•Sep 30, 2020•8 citations

A microwave cryogenic low-noise amplifier based on sige heterostructures

Boris I. Ivanov, M. Grajcar, Ilya L. Novikov +2 more

A low-noise cryogenic amplifier for the measurement of weak microwave signals at sub-Kelvin temperatures is constructed. The amplifier has five stages based on SiGe bipolar heterostructure transistors and has a gain factor of 35 dB in the frequency band from 100 MHz to 4 GHz at an operating temperature of 800 mK. The parameters of a superconducting quantum bit measured with this amplifier in the ultralow-power mode are presented as an application example. The amplitude–frequency response of the “supercon-ducting qubit–coplanar cavity” structure is demonstrated. The ground state of the qubit is characterized in the quasi-dispersive measurement mode.

Technical Physics Letters•Apr 1, 2016•19 citations

Quantum noise squeezing at microwave frequencies

R. Movshovich, B. Yurke, P. G. Kaminsky +3 more

We report the observation of zero-point noise squeezing by means of a Josephson- junction parametric amplifier, which has been used previously to squeeze 4.2 K thermal noise1. To observe quantum noise squeezing, a number of improvements were made on the apparatus; these include the in stallation of two low-noise cryogenic high- electron-mobility-transistor (HEMT) amplifiers, which boosted the detector sensitivity an order of magnitude to 215 K. The Josephson- junction parametric amplifier was cooled to 30 mK and was operated in the degenerate mode with the signal carrier frequency at 19.16 GHz. At this frequency the vacuum noise floor is hv/2k = 0.46 K. In the deamplified quadrature a drop in the noise of 0.223 K was observed relative to the pump-off noise floor. The pump-off noise floor was established to be within 3.4 + 2.0% of the vacuum noise floor by varying the temperature of the cold termination at the parametric amplifier's input from 30 mK to 1K. A probe signal at the input of the first HEMT amplifier was used to establish that the detector system saturation was less than 7 × 10−4 dB. We have thus observed squeezing 47% ± 8% below the vacuum noise floor.

Annual Meeting Optical Society of America•Jan 1, 1990•0 citations

Four-channel System for Characterization of Josephson Parametric Amplifiers

Boris I. Ivanov, Jinmyeong Kim, Çağlar Kutlu +8 more

The axion search experiments based on haloscopes at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) in South Korea are performed in the frequency range from 1 GHz to 6 GHz.In order to perform the experiments in a strong magnetic field of 12 T and a large-volume cavity of close to 40 liters, we use He wet dilution refrigerators with immersed superconducting magnets.The measurements require continuous operation for months without interruptions for microwave component replacements.This is achieved by using different cryogenic engineering approaches including microwave RF-switching.The critical components, defining the scanning rate and the sensitivity of the setup, are the Josephson parametric amplifiers (JPA) and cryogenic low noise amplifiers (cLNA) based on high-electron-mobility-transistor (HEMT) technology.It is desirable for both devices to have a wide frequency range and low noise close to the quantum limit for the JPA.In this paper, we show a recent design of a 4-channel measurement setup for JPA and HEMT measurements.The setup is based on a 4-channel wideband noise source (NS) and is used for both JPA and HEMT gain and noise measurements.The setup is placed at 20 mK inside the dry dilution refrigerator.The NS is thermally decoupled from the environment using plastic spacers, superconducting wires and superconducting coaxial cables.We show the gain and noise temperature curves measured for 4 HEMT amplifiers and 2 JPAs in one cool-down.

arXiv:2304.13367•International Conference on Low Temperature Physics (LT)•May 22, 2023•4 citations
We present a cryogenic microwave noise source with a characteristic impedance of 50 Ω, which can be installed in a coaxial line of a cryostat. The bath temperature of the noise source is continuously variable between 0.1 K and 5 K without causing significant back-action heating on the sample space. As a proof-of-concept experiment, we perform Y-factor measurements of an amplifier cascade that includes a traveling wave parametric amplifier and a commercial high electron mobility transistor amplifier. We observe system noise temperatures as low as 680−200+20 mK at 5.7 GHz corresponding to 1.5−0.7+0.1 excess photons. The system we present has immediate applications in the validation of solid-state qubit readout lines.
Parametric amplifiers have become a workhorse in superconducting quantum computing; however, research and development of these devices has been hampered by inconsistent and, sometimes, misleading noise performance characterization methodologies. The concepts behind noise characterization are deceptively simple, and there are many places where one can make mistakes, either in measurement or in interpretation and analysis. In this article, we cover the basics of noise performance characterization and the special problems it presents in parametric amplifiers with limited power handling capability. We illustrate the issues with three specific examples: a high-electron mobility transistor amplifier, a Josephson traveling-wave parametric amplifier, and a Josephson parametric amplifier. We emphasize the use of a 50-Ω shot noise tunnel junction (SNTJ) as a broadband noise source, demonstrating its utility for cryogenic amplifier amplifications. These practical examples highlight the role of loss as well as the additional parametric amplifier "idler" input mode.
Accurate in situ calibration of microwave attenuation and amplification-chain noise is essential for superconducting quantum circuits. We demonstrate a compact, self-calibrating cryogenic noise source based on an on-chip chromium attenuator that can be resistively heated with nanowatt-level power and directly integrated into a coaxial microwave line at the mixing-chamber stage. By comparing Johnson-Nyquist noise generated by Joule and microwave heating, measured through the amplification chain, the attenuation of the input line, and hence the gain of the chain, is determined without requiring knowledge of the attenuator temperature. The device exhibits millisecond-scale response times and negligible heating of the cryostat base plate. Using this approach, we determine the gain and added noise of a cryogenic amplification chain over the 4-8 GHz band. Our results provide a simple and accurate method to characterize near-quantum-limited parametric amplifiers used in superconducting-qubit readout.
A broadband low-noise four-stage high-electron-mobility transistor amplifier was designed and characterized in a cryogen-free dilution refrigerator at the 3.8 K temperature stage. The obtained power dissipation of the amplifier is below 20 mW. In the frequency range from 6 to 12 GHz its gain exceeds 30 dB. The equivalent noise temperature of the amplifier is below 6 K for the presented frequency range. The amplifier is applicable for any type of cryogenic microwave measurements. As an example we demonstrate here the characterization of the superconducting X-mon qubit coupled to an on-chip coplanar waveguide resonator.
A low-noise cryogenic amplifier for the measurement of weak microwave signals at sub-Kelvin temperatures is constructed. The amplifier has five stages based on SiGe bipolar heterostructure transistors and has a gain factor of 35 dB in the frequency band from 100 MHz to 4 GHz at an operating temperature of 800 mK. The parameters of a superconducting quantum bit measured with this amplifier in the ultralow-power mode are presented as an application example. The amplitude–frequency response of the “supercon-ducting qubit–coplanar cavity” structure is demonstrated. The ground state of the qubit is characterized in the quasi-dispersive measurement mode.
We report the observation of zero-point noise squeezing by means of a Josephson- junction parametric amplifier, which has been used previously to squeeze 4.2 K thermal noise1. To observe quantum noise squeezing, a number of improvements were made on the apparatus; these include the in stallation of two low-noise cryogenic high- electron-mobility-transistor (HEMT) amplifiers, which boosted the detector sensitivity an order of magnitude to 215 K. The Josephson- junction parametric amplifier was cooled to 30 mK and was operated in the degenerate mode with the signal carrier frequency at 19.16 GHz. At this frequency the vacuum noise floor is hv/2k = 0.46 K. In the deamplified quadrature a drop in the noise of 0.223 K was observed relative to the pump-off noise floor. The pump-off noise floor was established to be within 3.4 + 2.0% of the vacuum noise floor by varying the temperature of the cold termination at the parametric amplifier's input from 30 mK to 1K. A probe signal at the input of the first HEMT amplifier was used to establish that the detector system saturation was less than 7 × 10−4 dB. We have thus observed squeezing 47% ± 8% below the vacuum noise floor.
The axion search experiments based on haloscopes at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) in South Korea are performed in the frequency range from 1 GHz to 6 GHz.In order to perform the experiments in a strong magnetic field of 12 T and a large-volume cavity of close to 40 liters, we use He wet dilution refrigerators with immersed superconducting magnets.The measurements require continuous operation for months without interruptions for microwave component replacements.This is achieved by using different cryogenic engineering approaches including microwave RF-switching.The critical components, defining the scanning rate and the sensitivity of the setup, are the Josephson parametric amplifiers (JPA) and cryogenic low noise amplifiers (cLNA) based on high-electron-mobility-transistor (HEMT) technology.It is desirable for both devices to have a wide frequency range and low noise close to the quantum limit for the JPA.In this paper, we show a recent design of a 4-channel measurement setup for JPA and HEMT measurements.The setup is based on a 4-channel wideband noise source (NS) and is used for both JPA and HEMT gain and noise measurements.The setup is placed at 20 mK inside the dry dilution refrigerator.The NS is thermally decoupled from the environment using plastic spacers, superconducting wires and superconducting coaxial cables.We show the gain and noise temperature curves measured for 4 HEMT amplifiers and 2 JPAs in one cool-down.