arXiv:2005.05674 · Optics Express

Single-shot reconstruction of the density profile of a dense atomic gas

Carmelo Mordini, Dimitrios Trypogeorgos, L. Wolswijk, Giacomo Lamporesi, G. Ferrari

Published Jul 14, 2020• 6 citations
arXivHTMLPDF

Abstract

Partial transfer absorption imaging (PTAI) of ultracold atoms allows for repeated and minimally-destructive measurements of an atomic ensemble. Here, we present a reconstruction technique based on PTAI that can be used to piece together the non-uniform spatial profile of high-density atomic samples using multiple measurements. We achieved a thirty-fold increase of the effective dynamic range of our imaging, and were able to image otherwise saturated samples with unprecedented accuracy of both low- and high-density features.

DOI
10.1364/oe.397567

Related papers

Partial-transfer absorption imaging: A versatile technique for optimal imaging of ultracold gases

Anand K. Ramanathan, Sérgio Ricardo Muniz, Kevin Wright +4 more

Partial-transfer absorption imaging is a tool that enables optimal imaging of atomic clouds for a wide range of optical depths. In contrast to standard absorption imaging, the technique can be minimally destructive and can be used to obtain multiple successive images of the same sample. The technique involves transferring a small fraction of the sample from an initial internal atomic state to an auxiliary state and subsequently imaging that fraction absorptively on a cycling transition. The atoms remaining in the initial state are essentially unaffected. We demonstrate the technique, discuss its applicability, and compare its performance as a minimally destructive technique to that of phase-contrast imaging.

arXiv:1206.7048•Review of Scientific Instruments•Aug 1, 2012•56 citations

Repeated measurements with minimally destructive partial-transfer absorption imaging

Erin Marshall Seroka, Ana Valdés Curiel, Dimitrios Trypogeorgos +2 more

We demonstrate partial-transfer absorption imaging as a technique for repeatedly imaging an ultracold atomic ensemble with minimal perturbation. We prepare an atomic cloud in a state that is dark to the imaging light. We then use a microwave pulse to coherently transfer a small fraction of the ensemble to a bright state, which we image using in situ absorption imaging. The amplitude or duration of the microwave pulse controls the fractional transfer from the dark to the bright state. For small transfer fractions, we can image the atomic cloud up to 50 times before it is depleted. As a sample application, we repeatedly image an atomic cloud oscillating in a dipole trap to measure the trap frequency.

arXiv:1907.05372•Optics Express•Dec 2, 2019•13 citations

Phase-contrast imaging of a dense atomic cloud

Marcia Frómeta Fernández, Pablo Gabriel Santos Dias, P. H. N. Magnani +5 more

We demonstrate that phase-contrast imaging (PCI) can reliably reconstruct the in situ density profile even for highly spatially and optically dense samples. In our experiment, we achieve high spatial densities of up to 7.9 × 1013 atoms/cm3 and optical depths up to 64 in a dense cold atomic cloud of 88Sr atoms. The use of a spatial light modulator instead of a fixed phase plate in the PCI setup provides enhanced flexibility and control of imaging parameters, making this imaging technique robust against imaging artifacts and adaptable to varying experimental conditions. Moreover, we quantify the conditions under which the standard single-atom polarizability model remains accurate for PCI in a density regime where collective effects should modify the atomic response of the system. We experimentally validate our statements by showing excellent agreement with time-of-flight measurements even at the highest densities. Our results establish PCI as a reliable and versatile method for characterizing spatially dense atomic clouds.

arXiv:2501.03158•Review of Scientific Instruments•Aug 1, 2025•3 citations

Strong saturation absorption imaging of dense clouds of ultracold atoms

Gael Reinaudi, Thierry Lahaye, Z. Wang +1 more

We report on a far above saturation absorption imaging technique to investigate the characteristics of dense packets of ultracold atoms. The transparency of the cloud is controlled by the incident light intensity as a result of the nonlinear response of the atoms to the probe beam. We detail our experimental procedure to calibrate the imaging system for reliable quantitative measurements and demonstrate the use of this technique to extract the profile and its spatial extent of an optically thick atomic cloud.

arXiv:0707.2930•Optics Letters•Oct 23, 2007•246 citations

Calibration of saturation absorption imaging of ultracold atom clouds

Woo Jin Kwon, Jae-yoon Choi, Yong-il Shin

We describe an experimental method to calibrate an absorption imaging system for ultracold atom clouds. Optical density profiles of an atom cloud are obtained for various probe beam intensities and are analyzed to determine the correction factor for the effective probe beam intensity directly from saturation effects. We find that the temporal shape of the probe-beam pulse needs to be taken into account for a quantitative analysis of the optical density measured in saturation absorption imaging. We show that this pulse-shape effect can lead to distortion of the density profile due to its nonlinear dependence on the optical depth.

Journal of the Korean Physical Society•Dec 1, 2012•8 citations

Superresolving atomic densities

Jelena Stajic

Atomic Physics Quantum gas microscopes provide information about the occupancy of individual optical lattice sites. However, the resolution is limited by the wavelength of the imaging light. Two related superresolution schemes now enable researchers to glean even finer details of the atomic density distribution. McDonald et al. and Subhankar et al. studied one-dimensional arrays of ultracold atoms. A well-chosen perturbation provided a narrow window onto a specific position; when information from different positions was pieced together, the researchers were able to reconstruct the atomic density with a resolution of a fraction of the optical wavelength. The schemes were effective in capturing atomic dynamics and are expected to be applicable to a wide range of atomic and molecular species. Phys. Rev. X 9 , 021001, 021002 (2019).

Science•May 16, 2019•0 citations
Partial transfer absorption imaging (PTAI) of ultracold atoms allows for repeated and minimally-destructive measurements of an atomic ensemble. Here, we present a reconstruction technique based on PTAI that can be used to piece together the non-uniform spatial profile of high-density atomic samples using multiple measurements. We achieved a thirty-fold increase of the effective dynamic range of our imaging, and were able to image otherwise saturated samples with unprecedented accuracy of both low- and high-density features.
Partial-transfer absorption imaging is a tool that enables optimal imaging of atomic clouds for a wide range of optical depths. In contrast to standard absorption imaging, the technique can be minimally destructive and can be used to obtain multiple successive images of the same sample. The technique involves transferring a small fraction of the sample from an initial internal atomic state to an auxiliary state and subsequently imaging that fraction absorptively on a cycling transition. The atoms remaining in the initial state are essentially unaffected. We demonstrate the technique, discuss its applicability, and compare its performance as a minimally destructive technique to that of phase-contrast imaging.
We demonstrate partial-transfer absorption imaging as a technique for repeatedly imaging an ultracold atomic ensemble with minimal perturbation. We prepare an atomic cloud in a state that is dark to the imaging light. We then use a microwave pulse to coherently transfer a small fraction of the ensemble to a bright state, which we image using in situ absorption imaging. The amplitude or duration of the microwave pulse controls the fractional transfer from the dark to the bright state. For small transfer fractions, we can image the atomic cloud up to 50 times before it is depleted. As a sample application, we repeatedly image an atomic cloud oscillating in a dipole trap to measure the trap frequency.
We demonstrate that phase-contrast imaging (PCI) can reliably reconstruct the in situ density profile even for highly spatially and optically dense samples. In our experiment, we achieve high spatial densities of up to 7.9 × 1013 atoms/cm3 and optical depths up to 64 in a dense cold atomic cloud of 88Sr atoms. The use of a spatial light modulator instead of a fixed phase plate in the PCI setup provides enhanced flexibility and control of imaging parameters, making this imaging technique robust against imaging artifacts and adaptable to varying experimental conditions. Moreover, we quantify the conditions under which the standard single-atom polarizability model remains accurate for PCI in a density regime where collective effects should modify the atomic response of the system. We experimentally validate our statements by showing excellent agreement with time-of-flight measurements even at the highest densities. Our results establish PCI as a reliable and versatile method for characterizing spatially dense atomic clouds.
We report on a far above saturation absorption imaging technique to investigate the characteristics of dense packets of ultracold atoms. The transparency of the cloud is controlled by the incident light intensity as a result of the nonlinear response of the atoms to the probe beam. We detail our experimental procedure to calibrate the imaging system for reliable quantitative measurements and demonstrate the use of this technique to extract the profile and its spatial extent of an optically thick atomic cloud.
We describe an experimental method to calibrate an absorption imaging system for ultracold atom clouds. Optical density profiles of an atom cloud are obtained for various probe beam intensities and are analyzed to determine the correction factor for the effective probe beam intensity directly from saturation effects. We find that the temporal shape of the probe-beam pulse needs to be taken into account for a quantitative analysis of the optical density measured in saturation absorption imaging. We show that this pulse-shape effect can lead to distortion of the density profile due to its nonlinear dependence on the optical depth.
Atomic Physics Quantum gas microscopes provide information about the occupancy of individual optical lattice sites. However, the resolution is limited by the wavelength of the imaging light. Two related superresolution schemes now enable researchers to glean even finer details of the atomic density distribution. McDonald et al. and Subhankar et al. studied one-dimensional arrays of ultracold atoms. A well-chosen perturbation provided a narrow window onto a specific position; when information from different positions was pieced together, the researchers were able to reconstruct the atomic density with a resolution of a fraction of the optical wavelength. The schemes were effective in capturing atomic dynamics and are expected to be applicable to a wide range of atomic and molecular species. Phys. Rev. X 9 , 021001, 021002 (2019).