Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2004.01108 · Physical Review A

Weak-value-amplification analysis beyond the Aharonov-Albert-Vaidman limit

Jianhua Ren, Lupei Qin, Wei Feng, Xin-Qi Li

Published Oct 1, 2020• 30 citations
arXivHTMLPDF

Abstract

The weak-value (WV) measurement proposed by Aharonov, Albert, and Vaidman (AAV) has attracted a great deal of interest in connection with quantum metrology. In this paper, we extend the analysis beyond the AAV limit and obtain a few main results. (i) We obtain a nonperturbative result for the signal-to-noise ratio (SNR). In contrast to the AAV prediction, we find that the SNR asymptotically gets worse when the AAV WV ${A}_{w}$ becomes large, i.e., in the case $g|{A}_{w}{|}^{2}\ensuremath{\gg}1$, where $g$ is the measurement strength. (ii) With the increase of $g$ (but also small), we find that the SNR is comparable to the result under the AAV limit, while both can reach---actually the former can slightly exceed---the SNR of the standard measurement. However, with a further increase of $g$, the WV technique will become less efficient than the standard measurement, despite the fact that the postselection probability is increased. (iii) We find that the Fisher information can characterize the estimate precision qualitatively well as the SNR, yet the difference will become more prominent with the increase of $g$. (iv) We carry out analytic expressions of the SNR in the presence of technical noises and illustrate the particular advantage of the imaginary WV measurement. The nonperturbative result of the SNR manifests a favorable range of the noise strength and allows an optimal determination.

DOI
10.1103/physreva.102.042601

Related papers

Limits on amplification by Aharonov-Albert-Vaidman weak measurement

Tatsuhiko Koike, Saki Tanaka

We analyze the amplification by the Aharonov-Albert-Vaidman weak quantum measurement on a Sagnac interferometer [Dixon et al., Phys. Rev. Lett. 102, 173601 (2009)] up to all orders of the coupling strength between the measured system and the measuring device. The amplifier transforms a small tilt of a mirror into a large transverse displacement of the laser beam. The conventional analysis has shown that the measured value is proportional to the weak value, so that the amplification can be made arbitrarily large in the cost of decreasing output laser intensity. It is shown that the measured displacement and the amplification factor are in fact not proportional to the weak value and rather vanish in the limit of infinitesimal output intensity. We derive the optimal overlap of the pre- and postselected states with which the amplification become maximum. We also show that the nonlinear effects begin to arise in the performed experiments so that any improvements in the experiment, typically with an amplification greater than 100, should require the nonlinear theory in translating the observed value to the original displacement.

arXiv:1108.2050•Physical Review A•Dec 5, 2011•60 citations

Weak values in continuous weak measurements of qubits

Lupei Qin, Pengfei Liang, Xin-Qi Li

For continuous weak measurements of qubits, we obtain exact expressions for weak values (WVs) from the postselection restricted average of measurement outputs, by using both the quantum-trajectory equation (QTE) and the quantum Bayesian approach. The former is applicable to short-time weak measurement, while the latter can relax the measurement strength to finite. We find that even in the ``very'' weak limit the result can be essentially different from the one originally proposed by Aharonov, Albert, and Vaidman (AAV), in the sense that our result incorporates nonperturbative correction which could be important when the AAV WV is large. Within the Bayesian framework, we obtain also elegant expressions for finite measurement strength and find that the amplifier's noise in quantum measurement has no effect on the WVs. In particular, we obtain very useful results for homodyne measurement in a circuit-QED system, which allows for measuring the real and imaginary parts of the AAV WV by simply tuning the phase of the local oscillator. This advantage can be exploited as an efficient state-tomography technique.

arXiv:1502.02396•Physical Review A•Jul 23, 2015•8 citations

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

An optical Aharonov-Albert-Vaidman effect

Allen Parks, David W. Cullin, D.C. Stoudt +1 more

The notion of the weak value of a quantum mechanical observable has recently been introduced by Aharonov et al. (Phys. Rev A 41,11 (1990)), hereafter referred to as AAV. We have performed an experiment similar to one proposed by Knight et al. (1990) and demonstrated that weak values can be observed and that they exhibit the properties described by AAV within the regime of validity. We suggest that preselection and postselection measurement techniques could be useful for study of physical phenomena that might be otherwise unobservable.

Southeastern Symposium on System Theory (SSST)•Nov 27, 2002•0 citations

Autocorrelative weak-value amplification and simulating the protocol under strong Gaussian noise

Jing-Hui Huang, Xiangyun Hu, Adetunmise C. Dada +4 more

By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.

arXiv:2203.15231•Physical Review A•Nov 3, 2022•9 citations

Observation and measurement of an optical Aharonov–Albert–Vaidman effect

Allen Parks, David W. Cullin, D.C. Stoudt

The notion of the weak value of a quantum mechanical observable has recently been introduced by Aharonov et al., hereafter referred to as AAV. Their analysis led to the controversial result that the weak values for an observable can lie well outside its associated eigenvalue spectrum. We have performed an experiment similar to one proposed by Knight et al. and demonstrated that weak values can be observed and that they exhibit the properties described by AAV within the regime of validity defined by Duck et al. It is shown that these properties are produced by interference phenomena that result from the loss of ‘welcher Weg’ information. We have also identified an intrinsic ‘weak energy’ which appears in the equation of motion for the weak value of an observable and have shown that it can be non–vanishing only for systems which are both preselected and postselected. It is noted that such a ‘weak spin–rotation coupling energy’ can be associated with our experiment and that it is manifested in our experimental data. We suggest that preselection and postselection measurement techniques could be useful for the creation and study of physical phenomena that might be otherwise unobservable.

Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences•Nov 8, 1998•73 citations
The weak-value (WV) measurement proposed by Aharonov, Albert, and Vaidman (AAV) has attracted a great deal of interest in connection with quantum metrology. In this paper, we extend the analysis beyond the AAV limit and obtain a few main results. (i) We obtain a nonperturbative result for the signal-to-noise ratio (SNR). In contrast to the AAV prediction, we find that the SNR asymptotically gets worse when the AAV WV Aw{A}_{w}Aw​ becomes large, i.e., in the case g∣Aw∣2\ensuremath≫1g|{A}_{w}{|}^{2}\ensuremath{\gg}1g∣Aw​∣2\ensuremath≫1, where ggg is the measurement strength. (ii) With the increase of ggg (but also small), we find that the SNR is comparable to the result under the AAV limit, while both can reach---actually the former can slightly exceed---the SNR of the standard measurement. However, with a further increase of ggg, the WV technique will become less efficient than the standard measurement, despite the fact that the postselection probability is increased. (iii) We find that the Fisher information can characterize the estimate precision qualitatively well as the SNR, yet the difference will become more prominent with the increase of ggg. (iv) We carry out analytic expressions of the SNR in the presence of technical noises and illustrate the particular advantage of the imaginary WV measurement. The nonperturbative result of the SNR manifests a favorable range of the noise strength and allows an optimal determination.
We analyze the amplification by the Aharonov-Albert-Vaidman weak quantum measurement on a Sagnac interferometer [Dixon et al., Phys. Rev. Lett. 102, 173601 (2009)] up to all orders of the coupling strength between the measured system and the measuring device. The amplifier transforms a small tilt of a mirror into a large transverse displacement of the laser beam. The conventional analysis has shown that the measured value is proportional to the weak value, so that the amplification can be made arbitrarily large in the cost of decreasing output laser intensity. It is shown that the measured displacement and the amplification factor are in fact not proportional to the weak value and rather vanish in the limit of infinitesimal output intensity. We derive the optimal overlap of the pre- and postselected states with which the amplification become maximum. We also show that the nonlinear effects begin to arise in the performed experiments so that any improvements in the experiment, typically with an amplification greater than 100, should require the nonlinear theory in translating the observed value to the original displacement.
For continuous weak measurements of qubits, we obtain exact expressions for weak values (WVs) from the postselection restricted average of measurement outputs, by using both the quantum-trajectory equation (QTE) and the quantum Bayesian approach. The former is applicable to short-time weak measurement, while the latter can relax the measurement strength to finite. We find that even in the ``very'' weak limit the result can be essentially different from the one originally proposed by Aharonov, Albert, and Vaidman (AAV), in the sense that our result incorporates nonperturbative correction which could be important when the AAV WV is large. Within the Bayesian framework, we obtain also elegant expressions for finite measurement strength and find that the amplifier's noise in quantum measurement has no effect on the WVs. In particular, we obtain very useful results for homodyne measurement in a circuit-QED system, which allows for measuring the real and imaginary parts of the AAV WV by simply tuning the phase of the local oscillator. This advantage can be exploited as an efficient state-tomography technique.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
The notion of the weak value of a quantum mechanical observable has recently been introduced by Aharonov et al. (Phys. Rev A 41,11 (1990)), hereafter referred to as AAV. We have performed an experiment similar to one proposed by Knight et al. (1990) and demonstrated that weak values can be observed and that they exhibit the properties described by AAV within the regime of validity. We suggest that preselection and postselection measurement techniques could be useful for study of physical phenomena that might be otherwise unobservable.
By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.
The notion of the weak value of a quantum mechanical observable has recently been introduced by Aharonov et al., hereafter referred to as AAV. Their analysis led to the controversial result that the weak values for an observable can lie well outside its associated eigenvalue spectrum. We have performed an experiment similar to one proposed by Knight et al. and demonstrated that weak values can be observed and that they exhibit the properties described by AAV within the regime of validity defined by Duck et al. It is shown that these properties are produced by interference phenomena that result from the loss of ‘welcher Weg’ information. We have also identified an intrinsic ‘weak energy’ which appears in the equation of motion for the weak value of an observable and have shown that it can be non–vanishing only for systems which are both preselected and postselected. It is noted that such a ‘weak spin–rotation coupling energy’ can be associated with our experiment and that it is manifested in our experimental data. We suggest that preselection and postselection measurement techniques could be useful for the creation and study of physical phenomena that might be otherwise unobservable.