Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1907.12601 · Bulletin of the American Physical Society

Imaging Nematic Transitions in Iron-Pnictide Superconductors with a Quantum Gas

Fan Yang, Stephen Taylor, Stephen D. Edkins, Johanna C. Palmstrom, I. R. Fisher, Benjamin Lev

Published Jul 29, 2019• 1 citation
arXivHTMLPDF

Abstract

The SQCRAMscope is a recently realized Scanning Quantum CRyogenic Atom Microscope that utilizes an atomic Bose-Einstein condensate to measure magnetic fields emanating from solid-state samples. The quantum sensor does so with unprecedented DC sensitivity at micron resolution from room-to-cryogenic temperatures. An additional advantage of the SQCRAMscope is the preservation of optical access to the sample: Magnetometry imaging of, e.g., electron transport may be performed in concert with other imaging techniques. This multimodal imaging capability can be brought to bear with great effect in the study of nematicity in iron-pnictide high-temperature superconductors, where the relationship between electronic and structural symmetry-breaking resulting in a nematic phase is under debate. Here, we combine the SQCRAMscope with an in situ microscope that measures optical birefringence near the surface. This enables simultaneous and spatially resolved detection of both bulk and near-surface manifestations of nematicity via transport and structural deformation channels, respectively. By performing the first local measurement of emergent resistivity anisotropy in iron pnictides, we observe sharp, nearly concurrent transport and structural transitions. More broadly, these measurements demonstrate the SQCRAMscope's ability to reveal important insights into the physics of complex quantum materials.

DOI
10.48550/arxiv.1907.12601

Related papers

Sensing Magnetic Fields with a Giant Quantum Wave

József Fortágh, Andreas Günther

Microscopic imaging of local magnetic fields provides a window into the organizing principles of complex and technologically relevant condensed-matter materials.However, a wide variety of intriguing strongly correlated and topologically nontrivial materials exhibit poorly understood phenomena outside the detection capability of state-of-the-art high-sensitivity high-resolution scanning probe magnetometers.We introduce a quantum-noise-limited scanning probe magnetometer that can operate from room-to-cryogenic temperatures with unprecedented dc-field sensitivity and micron-scale resolution.The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) employs a magnetically levitated atomic Bose-Einstein condensate (BEC), thereby providing immunity to conductive and blackbody radiative heating.The SQCRAMscope has a field sensitivity of 1.4 nT per resolution-limited point (approximately 2 μm) or 6 nT= ffiffiffiffiffiffi Hz p per point at its duty cycle.Compared to point-by-point sensors, the long length of the BEC provides a naturally parallel measurement, allowing one to measure nearly 100 points with an effective field sensitivity of 600 pT= ffiffiffiffiffiffi Hz p for each point during the same time as a point-by-point scanner measures these points sequentially.Moreover, it has a noise floor of 300 pT and provides nearly 2 orders of magnitude improvement in magnetic flux sensitivity (down to 10 -6 Φ 0 = ffiffiffiffiffiffi Hz p ) over previous atomic probe magnetometers capable of scanning near samples.These capabilities are carefully benchmarked by imaging magnetic fields arising from microfabricated wire patterns in a system where samples may be scanned, cryogenically cooled, and easily exchanged.We anticipate the SQCRAMscope will provide charge-transport images at temperatures from room temperature to 4 K in unconventional superconductors and topologically nontrivial materials.

Physics•Mar 27, 2017•0 citations

Scanning Quantum Cryogenic Atom Microscope

Fan Yang, Alicia J. Kollár, Stephen Taylor +2 more

Microscopic imaging of local magnetic fields provides a window into the inner workings of complex and technologically relevant materials. The authors present an extremely sensitive scanning-probe microscope for imaging charge transport in strongly correlated and topologically nontrivial systems, from ambient down to liquid-helium temperature. This scanning quantum cryogenic atom microscope (SQCRAMscope) will change research spanning disciplines from basic condensed matter physics to the engineering of hybrid quantum systems.

arXiv:1608.06922•Physical Review Applied•Mar 27, 2017•39 citations

A scanning quantum cryogenic atom microscope at 6 K

Stephen Taylor, Fan Yang, Brandon A. Freudenstein +1 more

The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) is a quantum sensor in which a quasi-1D quantum gas images electromagnetic fields emitted from a nearby sample. We report improvements to the microscope. Cryogen usage is reduced by replacing the liquid cryostat with a closed-cycle system and modified cold finger, and cryogenic cooling is enhanced by adding a radiation shield. The minimum accessible sample temperature is reduced from 35~K to 5.7~K while maintaining low sample vibrations. A new sample mount is easier to exchange, and quantum gas preparation is streamlined.

arXiv:2010.03559•SciPost Physics•Mar 9, 2021•4 citations

Quantum gas microscopy for magnetic field imaging and current density mapping of nanostructures

Poppy Joshi (11375517)

People have been measuring magnetic fields since 200 BC, giving rise to the field of magnetometry. Recently there has been a drive to measure smaller fields with better resolution, resulting in the production of many different types of magnetometers, each with their own unique features. These magnetometers can have a diverse range of applications such as, GNSS free navigation, biomedical sensing, space and weather measurements, and material physics. When designing a magnetomoter there is a trade off between high sensitivity to magnetic fields and high spatial resolution. Currently, there is a unoccupied niche in direct current (DC) magnetometry, that requires a magnetic field sensitivity in the picotesla range and micron scale spatial resolution. Here, I introduce the Bose-Einstein condensate (BEC), which is a macroscopic quantum object, ideal for probing magnetic fields on the nanotesla to picotesla range, with micron scale resolution. This thesis discusses the use of a BEC microscope (BEC-M) to characterise mate- rials with novel applications in nanotechnology by producing 2D current density maps. To produce the atomic probe for microscopy, a BEC in the quasi-1D regime is carefully prepared, requiring an ultra high vacuum (UHV) environment along with custom designed trapping structures, to optically and magnetically confine the atoms. The sensitivity and resolution of the BEC-M makes it an ideal tool for characterising electrical properties of structures on the micron scale such as carbon nanotube (CNT) bundles and biological samples. Current network configuration in samples such as these, can be mapped via a raster scanning procedure. A measurement was made to identify current pathways in CNTs by measuring the atomic distribution of the ultra cold cloud and converting these images to magnetic field and current density maps.

•Jun 6, 2025•0 citations

New Quantum Sensing Modalities of Nitrogen-Vacancy Centers

Qiu, Ziwei

The recent decade has witnessed exciting developments in quantum science and technology. Quantum sensing is a rapidly growing branch, which exploits the fragility of quantum systems to detect small external signals. The extreme control at the single-atom level and the remarkably long coherence time of engineered quantum systems enable unprecedented sensitivity and precision, beating the performance of classical techniques. The nitrogen-vacancy (NV) center in diamond is one of the most promising quantum sensors. Its unique advantages have attracted considerable attention, including a long spin coherence time throughout a broad temperature range, nanoscale resolution limited by the sensor-sample distance, convenient optical control of its spin states and remarkably versatile sensing capabilities. Its properties are well studied under a bias magnetic field oriented along its quantization axis. However, its sensing capabilities in the presence of an off-axis magnetic field are much less explored. My research aims to unlock the full potential of NV quantum sensor by developing new sensing modalities under a magnetic field acting perpendicular to the NV axis, and furthermore, integrating them into a scanning probe microscope. In this dissertation, I will report our progress toward building a scanning NV multimodal quantum imaging platform, which will open up exciting opportunities in measuring nanoscale phenomena. The first chapter provides an introduction to the background of quantum sensing with NV centers, followed by a discussion on its basic properties and established sensing techniques. The second and third chapters are dedicated to two experiments performed under a perpendicular magnetic field where traditional NV magnetometry based on the Zeeman effect fails. In the second chapter, I will introduce a new sensing strategy that uses the entanglement between the electron and nuclear spins to restore the magnetic field sensitivity under this unfavored condition. This allows us to sense small changes in the magnetic field angle relative to the NV axis, and to detect anisotropic magnetic noise in the local environment. In the third chapter, I will present our latest development of scanning NV electrometry, where a single NV at the apex of a diamond scanning probe images external alternating (AC) and direct (DC) electric fields with sub-100 nm resolution. In the last chapter, I will discuss our efforts on four experiments that were left unfinished. I will present the results we have achieved, analyze the challenges that we faced and propose potential solutions to overcome them.

•Jan 1, 2022•0 citations

Direct imaging of magnetotransport at graphene-metal interfaces with a single-spin quantum sensor

C. Ding, M. L. Palm, K. Kohli +3 more

Magnetotransport underlines many important phenomena in condensed matter physics, such as the Hall effect and magnetoresistance (MR) effect. Thus far, most magnetotransport studies are based on bulk resistance measurements without direct access to microscopic details of the spatial transport pattern. Here, we report nanoscale imaging of magnetotransport using a scanning single-spin quantum magnetometer, which is demonstrated in a graphene-metal hybrid device at room temperature. By visualizing the current flow at elevated magnetic fields (~0.5 T), we directly observe the Lorentz deflection of current near the graphene-metal interface, which is a hallmark of magnetotransport. Combining the local current distribution with global resistance measurements, we reveal that transport properties of the hybrid are governed by a complex interplay of intrinsic MR around the Dirac cone, carrier hydrodynamics, interface resistance, and the nanoscale device geometry. Furthermore, accessing the local transport pattern across the interface enables quantitative mapping of spatial variations in contact resistance, which is commonly present in electronic devices made from two-dimensional materials yet non-trivial to characterize. Our work demonstrates the potential of nanoscale current imaging techniques for studying complex electronic transport phenomena that are difficult to probe by resistance-based measurements.

cond-mat.mes-hallCross-listedarXiv:2511.07181•Nov 11, 2025
The SQCRAMscope is a recently realized Scanning Quantum CRyogenic Atom Microscope that utilizes an atomic Bose-Einstein condensate to measure magnetic fields emanating from solid-state samples. The quantum sensor does so with unprecedented DC sensitivity at micron resolution from room-to-cryogenic temperatures. An additional advantage of the SQCRAMscope is the preservation of optical access to the sample: Magnetometry imaging of, e.g., electron transport may be performed in concert with other imaging techniques. This multimodal imaging capability can be brought to bear with great effect in the study of nematicity in iron-pnictide high-temperature superconductors, where the relationship between electronic and structural symmetry-breaking resulting in a nematic phase is under debate. Here, we combine the SQCRAMscope with an in situ microscope that measures optical birefringence near the surface. This enables simultaneous and spatially resolved detection of both bulk and near-surface manifestations of nematicity via transport and structural deformation channels, respectively. By performing the first local measurement of emergent resistivity anisotropy in iron pnictides, we observe sharp, nearly concurrent transport and structural transitions. More broadly, these measurements demonstrate the SQCRAMscope's ability to reveal important insights into the physics of complex quantum materials.
Microscopic imaging of local magnetic fields provides a window into the organizing principles of complex and technologically relevant condensed-matter materials.However, a wide variety of intriguing strongly correlated and topologically nontrivial materials exhibit poorly understood phenomena outside the detection capability of state-of-the-art high-sensitivity high-resolution scanning probe magnetometers.We introduce a quantum-noise-limited scanning probe magnetometer that can operate from room-to-cryogenic temperatures with unprecedented dc-field sensitivity and micron-scale resolution.The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) employs a magnetically levitated atomic Bose-Einstein condensate (BEC), thereby providing immunity to conductive and blackbody radiative heating.The SQCRAMscope has a field sensitivity of 1.4 nT per resolution-limited point (approximately 2 μm) or 6 nT= ffiffiffiffiffiffi Hz p per point at its duty cycle.Compared to point-by-point sensors, the long length of the BEC provides a naturally parallel measurement, allowing one to measure nearly 100 points with an effective field sensitivity of 600 pT= ffiffiffiffiffiffi Hz p for each point during the same time as a point-by-point scanner measures these points sequentially.Moreover, it has a noise floor of 300 pT and provides nearly 2 orders of magnitude improvement in magnetic flux sensitivity (down to 10 -6 Φ 0 = ffiffiffiffiffiffi Hz p ) over previous atomic probe magnetometers capable of scanning near samples.These capabilities are carefully benchmarked by imaging magnetic fields arising from microfabricated wire patterns in a system where samples may be scanned, cryogenically cooled, and easily exchanged.We anticipate the SQCRAMscope will provide charge-transport images at temperatures from room temperature to 4 K in unconventional superconductors and topologically nontrivial materials.
Microscopic imaging of local magnetic fields provides a window into the inner workings of complex and technologically relevant materials. The authors present an extremely sensitive scanning-probe microscope for imaging charge transport in strongly correlated and topologically nontrivial systems, from ambient down to liquid-helium temperature. This scanning quantum cryogenic atom microscope (SQCRAMscope) will change research spanning disciplines from basic condensed matter physics to the engineering of hybrid quantum systems.
The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) is a quantum sensor in which a quasi-1D quantum gas images electromagnetic fields emitted from a nearby sample. We report improvements to the microscope. Cryogen usage is reduced by replacing the liquid cryostat with a closed-cycle system and modified cold finger, and cryogenic cooling is enhanced by adding a radiation shield. The minimum accessible sample temperature is reduced from 35~K to 5.7~K while maintaining low sample vibrations. A new sample mount is easier to exchange, and quantum gas preparation is streamlined.
People have been measuring magnetic fields since 200 BC, giving rise to the field of magnetometry. Recently there has been a drive to measure smaller fields with better resolution, resulting in the production of many different types of magnetometers, each with their own unique features. These magnetometers can have a diverse range of applications such as, GNSS free navigation, biomedical sensing, space and weather measurements, and material physics. When designing a magnetomoter there is a trade off between high sensitivity to magnetic fields and high spatial resolution. Currently, there is a unoccupied niche in direct current (DC) magnetometry, that requires a magnetic field sensitivity in the picotesla range and micron scale spatial resolution. Here, I introduce the Bose-Einstein condensate (BEC), which is a macroscopic quantum object, ideal for probing magnetic fields on the nanotesla to picotesla range, with micron scale resolution. This thesis discusses the use of a BEC microscope (BEC-M) to characterise mate- rials with novel applications in nanotechnology by producing 2D current density maps. To produce the atomic probe for microscopy, a BEC in the quasi-1D regime is carefully prepared, requiring an ultra high vacuum (UHV) environment along with custom designed trapping structures, to optically and magnetically confine the atoms. The sensitivity and resolution of the BEC-M makes it an ideal tool for characterising electrical properties of structures on the micron scale such as carbon nanotube (CNT) bundles and biological samples. Current network configuration in samples such as these, can be mapped via a raster scanning procedure. A measurement was made to identify current pathways in CNTs by measuring the atomic distribution of the ultra cold cloud and converting these images to magnetic field and current density maps.
The recent decade has witnessed exciting developments in quantum science and technology. Quantum sensing is a rapidly growing branch, which exploits the fragility of quantum systems to detect small external signals. The extreme control at the single-atom level and the remarkably long coherence time of engineered quantum systems enable unprecedented sensitivity and precision, beating the performance of classical techniques. The nitrogen-vacancy (NV) center in diamond is one of the most promising quantum sensors. Its unique advantages have attracted considerable attention, including a long spin coherence time throughout a broad temperature range, nanoscale resolution limited by the sensor-sample distance, convenient optical control of its spin states and remarkably versatile sensing capabilities. Its properties are well studied under a bias magnetic field oriented along its quantization axis. However, its sensing capabilities in the presence of an off-axis magnetic field are much less explored. My research aims to unlock the full potential of NV quantum sensor by developing new sensing modalities under a magnetic field acting perpendicular to the NV axis, and furthermore, integrating them into a scanning probe microscope. In this dissertation, I will report our progress toward building a scanning NV multimodal quantum imaging platform, which will open up exciting opportunities in measuring nanoscale phenomena. The first chapter provides an introduction to the background of quantum sensing with NV centers, followed by a discussion on its basic properties and established sensing techniques. The second and third chapters are dedicated to two experiments performed under a perpendicular magnetic field where traditional NV magnetometry based on the Zeeman effect fails. In the second chapter, I will introduce a new sensing strategy that uses the entanglement between the electron and nuclear spins to restore the magnetic field sensitivity under this unfavored condition. This allows us to sense small changes in the magnetic field angle relative to the NV axis, and to detect anisotropic magnetic noise in the local environment. In the third chapter, I will present our latest development of scanning NV electrometry, where a single NV at the apex of a diamond scanning probe images external alternating (AC) and direct (DC) electric fields with sub-100 nm resolution. In the last chapter, I will discuss our efforts on four experiments that were left unfinished. I will present the results we have achieved, analyze the challenges that we faced and propose potential solutions to overcome them.
Magnetotransport underlines many important phenomena in condensed matter physics, such as the Hall effect and magnetoresistance (MR) effect. Thus far, most magnetotransport studies are based on bulk resistance measurements without direct access to microscopic details of the spatial transport pattern. Here, we report nanoscale imaging of magnetotransport using a scanning single-spin quantum magnetometer, which is demonstrated in a graphene-metal hybrid device at room temperature. By visualizing the current flow at elevated magnetic fields (~0.5 T), we directly observe the Lorentz deflection of current near the graphene-metal interface, which is a hallmark of magnetotransport. Combining the local current distribution with global resistance measurements, we reveal that transport properties of the hybrid are governed by a complex interplay of intrinsic MR around the Dirac cone, carrier hydrodynamics, interface resistance, and the nanoscale device geometry. Furthermore, accessing the local transport pattern across the interface enables quantitative mapping of spatial variations in contact resistance, which is commonly present in electronic devices made from two-dimensional materials yet non-trivial to characterize. Our work demonstrates the potential of nanoscale current imaging techniques for studying complex electronic transport phenomena that are difficult to probe by resistance-based measurements.