Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1906.09969 · Optics Express

Superconducting nanowire single photon detectors operating at temperature from 4 to 7 K

Ronan Gourgues, Johannes W. N. Los, Julien Zichi, Jin Chang, Nima Kalhor, Gabriele Bulgarini, Sander N. Dorenbos, Val Zwiller, Iman Esmaeil Zadeh

Published Aug 14, 2019• 38 citations
arXivHTMLPDF

Abstract

We experimentally investigate the performance of NbTiN superconducting nanowire single photon detectors above the base temperature of a conventional Gifford-McMahon cryocooler (2.5 K). By tailoring design and thickness (8 - 13 nm) of the detectors, high performance, high operating temperature, single-photon detection from the visible to telecom wavelengths are demonstrated. At 4.3 K, a detection efficiency of 82 % at 785 nm wavelength and a timing jitter of 30 ± 0.3 ps are achieved. In addition, for 1550 nm and similar operating temperature we measured a detection efficiency as high as 64 %. Finally, we show that at temperatures up to 7 K, unity internal efficiency is maintained for the visible spectrum. Our work is particularly important to allow for the large scale implementation of superconducting single photon detectors in combination with heat sources such as free-space optical windows, cryogenic electronics, microwave sources and active optical components for complex quantum optical experiments and bio-imaging.

DOI
10.1364/oe.27.024601

Related papers

Performances of NbTiN superconducting nanowire single photon detector

Shigehito Miki, Taro Yamashita, Hirotaka Terai +1 more

We present high performance fiber-coupled niobium titanium nitride superconducting nanowire single photon detectors fabricated on thermally oxidized silicon substrates. By applying a double sided cavity structure, simulated absorptance in the nanowire meander reached 97% at 1550 nm wavelength. The fabricated device showed a system detection efficiency (DE) of 74% at 1550 nm, dark count rate of 100 c/s, and a full width at half maximum timing jitter of 68 ps under a bias current of 18.0 μA with a practical Gifford-McMahon cryocooler system.

IEEE International Superconductive Electronics Conference (ISEC)•Jul 1, 2013•1 citation

High performance fiber-coupled NbTiN superconducting nanowire single photon detectors with Gifford-McMahon cryocooler

Shigehito Miki, Taro Yamashita, Hirotaka Terai +1 more

We present high performance fiber-coupled niobium titanium nitride superconducting nanowire single photon detectors fabricated on thermally oxidized silicon substrates. The best device showed a system detection efficiency (DE) of 74%, dark count rate of 100 c/s, and full width at half maximum timing jitter of 68 ps under a bias current of 18.0 μA with a practical Gifford-McMahon cryocooler system. We also introduced six detectors into the cryocooler and confirmed that the system DE of all detectors was higher than 67% at the dark count rate of 100 c/s.

arXiv:1303.6381•Optics Express•Apr 17, 2013•185 citations

Single-photon detectors combining high efficiency, high detection rates, and ultra-high timing resolution

Iman Esmaeil Zadeh, Johannes W. N. Los, Ronan Gourgues +5 more

Single-photon detection with high efficiency, high time resolution, low dark counts, and high photon detection rates is crucial for a wide range of optical measurements. Although efficient detectors have been reported before, combining all performance parameters in a single device remains a challenge. Here, we show a broadband NbTiN superconducting nanowire detector with an efficiency exceeding 92%, over 150 MHz photon detection rate, and a dark count rate below 130 Hz operated in a Gifford-McMahon cryostat. Furthermore, with careful optimization of the detector design and readout electronics, we reach an ultra-low system timing jitter of 14.80 ps (13.95 ps decoupled) while maintaining high detection efficiencies (>75%).

arXiv:1611.02726•APL Photonics•Nov 1, 2017•189 citations

Single-photon detectors combining near unity efficiency, ultra-high detection-rates, and ultra-high time resolution

Iman Esmaeil Zadeh, Johannes W. N. Los, Ronan Gourgues +4 more

Single-photon detection with high efficiency, high time resolution, low dark counts and high photon detection-rates is required for a wide range of optical measurements. Although efficient detectors have been reported, combining all performances in a single device remains a challenge. Here, we show a broadband NbTiN superconducting nanowire detector with an efficiency over 92%, over 150MHz photon detection-rate and dark counts below 130Hz operated in a conventional Gifford-McMahon cryostat. Furthermore, with an optimized detector and readout electronics, we reach a record low jitter of 14.80ps while maintaining high efficiency.

•Nov 7, 2016•6 citations

Efficient mid-infrared single-photon detection using superconducting NbTiN nanowires with high time resolution in a Gifford-McMahon cryocooler

Jin Chang, Johannes W. N. Los, Ronan Gourgues +6 more

Shortly after their inception, superconducting nanowire single-photon detectors (SNSPDs) became the leading quantum light detection technology. With the capability of detecting single-photons with near-unity efficiency, high time resolution, low dark count rate, and fast recovery time, SNSPDs outperform conventional single-photon detection techniques. However, detecting lower energy single photons ( < 0.8 eV ) with high efficiency and low timing jitter has remained a challenge. To achieve unity internal efficiency at mid-infrared wavelengths, previous works used amorphous superconducting materials with low energy gaps at the expense of reduced time resolution (close to a nanosecond), and by operating them in complex milliKelvin (mK) dilution refrigerators. In this work, we provide an alternative approach with SNSPDs fabricated from 5 to 9.5 nm thick NbTiN superconducting films and devices operated in conventional Gifford-McMahon cryocoolers. By optimizing the superconducting film deposition process, film thickness, and nanowire design, our fiber-coupled devices achieved > 70 % system detection efficiency (SDE) at 2 μm and sub-15 ps timing jitter. Furthermore, detectors from the same batch demonstrated unity internal detection efficiency at 3 μm and 80% internal efficiency at 4 μm, paving the road for an efficient mid-infrared single-photon detection technology with unparalleled time resolution and without mK cooling requirements. We also systematically studied the dark count rates (DCRs) of our detectors coupled to different types of mid-infrared optical fibers and blackbody radiation filters. This offers insight into the trade-off between bandwidth and DCRs for mid-infrared SNSPDs. To conclude, this paper significantly extends the working wavelength range for SNSPDs made from polycrystalline NbTiN to 1.5–4 μm, and we expect quantum optics experiments and applications in the mid-infrared range to benefit from this far-reaching technology.

arXiv:2107.06354•Photonics Research•Jan 25, 2022•57 citations

High-efficiency superconducting nanowire single-photon detectors fabricated from MoSi thin-films

V. B. Verma, B. Korzh, F. Bussières +9 more

We report on MoSi SNSPDs which achieved high system detection efficiency (87.1 ± 0.5% at 1542 nm) at 0.7 K and we demonstrate that these detectors can also be operated with saturated internal efficiency at a temperature of 2.3 K in a Gifford-McMahon cryocooler. We measured a minimum system jitter of 76 ps, maximum count rate approaching 10 MHz, and polarization dependence as low as 3.3 ± 0.1%. The performance of MoSi SNSPDs at 2.3 K is similar to the performance of WSi SNSPDs at < 1 K. The higher operating temperature of MoSi SNSPDs makes these devices promising for widespread use due to the simpler and less expensive cryogenics required for their operation.

arXiv:1504.02793•Optics Express•Dec 22, 2015•140 citations
We experimentally investigate the performance of NbTiN superconducting nanowire single photon detectors above the base temperature of a conventional Gifford-McMahon cryocooler (2.5 K). By tailoring design and thickness (8 - 13 nm) of the detectors, high performance, high operating temperature, single-photon detection from the visible to telecom wavelengths are demonstrated. At 4.3 K, a detection efficiency of 82 % at 785 nm wavelength and a timing jitter of 30 ± 0.3 ps are achieved. In addition, for 1550 nm and similar operating temperature we measured a detection efficiency as high as 64 %. Finally, we show that at temperatures up to 7 K, unity internal efficiency is maintained for the visible spectrum. Our work is particularly important to allow for the large scale implementation of superconducting single photon detectors in combination with heat sources such as free-space optical windows, cryogenic electronics, microwave sources and active optical components for complex quantum optical experiments and bio-imaging.
We present high performance fiber-coupled niobium titanium nitride superconducting nanowire single photon detectors fabricated on thermally oxidized silicon substrates. By applying a double sided cavity structure, simulated absorptance in the nanowire meander reached 97% at 1550 nm wavelength. The fabricated device showed a system detection efficiency (DE) of 74% at 1550 nm, dark count rate of 100 c/s, and a full width at half maximum timing jitter of 68 ps under a bias current of 18.0 μA with a practical Gifford-McMahon cryocooler system.
We present high performance fiber-coupled niobium titanium nitride superconducting nanowire single photon detectors fabricated on thermally oxidized silicon substrates. The best device showed a system detection efficiency (DE) of 74%, dark count rate of 100 c/s, and full width at half maximum timing jitter of 68 ps under a bias current of 18.0 μA with a practical Gifford-McMahon cryocooler system. We also introduced six detectors into the cryocooler and confirmed that the system DE of all detectors was higher than 67% at the dark count rate of 100 c/s.
Single-photon detection with high efficiency, high time resolution, low dark counts, and high photon detection rates is crucial for a wide range of optical measurements. Although efficient detectors have been reported before, combining all performance parameters in a single device remains a challenge. Here, we show a broadband NbTiN superconducting nanowire detector with an efficiency exceeding 92%, over 150 MHz photon detection rate, and a dark count rate below 130 Hz operated in a Gifford-McMahon cryostat. Furthermore, with careful optimization of the detector design and readout electronics, we reach an ultra-low system timing jitter of 14.80 ps (13.95 ps decoupled) while maintaining high detection efficiencies (>75%).
Single-photon detection with high efficiency, high time resolution, low dark counts and high photon detection-rates is required for a wide range of optical measurements. Although efficient detectors have been reported, combining all performances in a single device remains a challenge. Here, we show a broadband NbTiN superconducting nanowire detector with an efficiency over 92%, over 150MHz photon detection-rate and dark counts below 130Hz operated in a conventional Gifford-McMahon cryostat. Furthermore, with an optimized detector and readout electronics, we reach a record low jitter of 14.80ps while maintaining high efficiency.
Shortly after their inception, superconducting nanowire single-photon detectors (SNSPDs) became the leading quantum light detection technology. With the capability of detecting single-photons with near-unity efficiency, high time resolution, low dark count rate, and fast recovery time, SNSPDs outperform conventional single-photon detection techniques. However, detecting lower energy single photons ( < 0.8 eV ) with high efficiency and low timing jitter has remained a challenge. To achieve unity internal efficiency at mid-infrared wavelengths, previous works used amorphous superconducting materials with low energy gaps at the expense of reduced time resolution (close to a nanosecond), and by operating them in complex milliKelvin (mK) dilution refrigerators. In this work, we provide an alternative approach with SNSPDs fabricated from 5 to 9.5 nm thick NbTiN superconducting films and devices operated in conventional Gifford-McMahon cryocoolers. By optimizing the superconducting film deposition process, film thickness, and nanowire design, our fiber-coupled devices achieved > 70 % system detection efficiency (SDE) at 2 μm and sub-15 ps timing jitter. Furthermore, detectors from the same batch demonstrated unity internal detection efficiency at 3 μm and 80% internal efficiency at 4 μm, paving the road for an efficient mid-infrared single-photon detection technology with unparalleled time resolution and without mK cooling requirements. We also systematically studied the dark count rates (DCRs) of our detectors coupled to different types of mid-infrared optical fibers and blackbody radiation filters. This offers insight into the trade-off between bandwidth and DCRs for mid-infrared SNSPDs. To conclude, this paper significantly extends the working wavelength range for SNSPDs made from polycrystalline NbTiN to 1.5–4 μm, and we expect quantum optics experiments and applications in the mid-infrared range to benefit from this far-reaching technology.
We report on MoSi SNSPDs which achieved high system detection efficiency (87.1 ± 0.5% at 1542 nm) at 0.7 K and we demonstrate that these detectors can also be operated with saturated internal efficiency at a temperature of 2.3 K in a Gifford-McMahon cryocooler. We measured a minimum system jitter of 76 ps, maximum count rate approaching 10 MHz, and polarization dependence as low as 3.3 ± 0.1%. The performance of MoSi SNSPDs at 2.3 K is similar to the performance of WSi SNSPDs at < 1 K. The higher operating temperature of MoSi SNSPDs makes these devices promising for widespread use due to the simpler and less expensive cryogenics required for their operation.