Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1906.07386 · Physical Review A

Architecture to achieve nuclear magnetic resonance spectroscopy with a superconducting flux qubit

Koichiro Miyanishi, Yuichiro Matsuzaki, Hiraku Toida, Kosuke Kakuyanagi, Makoto Negoro, Masahiro Kitagawa, Shiro Saito

Published May 1, 2020• 5 citations
arXivHTMLPDF

Abstract

We theoretically analyze the performance of the nuclear magnetic resonance (NMR) spectroscopy with a superconducting flux qubit (FQ). Such NMR with the FQ is attractive because of the possibility to detect the relatively small number of nuclear spins in a local region ($\ensuremath{\approx}\ensuremath{\mu}\mathrm{m}$) with low temperatures ($\ensuremath{\approx}\mathrm{mK}$) and low magnetic fields ($\ensuremath{\approx}\mathrm{mT}$), in which other types of quantum sensing schemes cannot easily be accessed. A sample containing nuclear spins is directly attached on the FQ, and the FQ is used as a magnetometer to detect magnetic fields from the nuclear spins. Especially, we consider two types of approaches to NMR with the FQ. One of them is to use spatially inhomogeneous excitations of the nuclear spins, which are induced by a spatially asymmetric driving with radio-frequency (rf) pulses. Such an inhomogeneity causes a change in the dc magnetic flux penetrating a loop of the FQ, which can be detected by a standard Ramsey measurement on the FQ. The other approach is to use a dynamical decoupling on the FQ to measure ac magnetic fields induced by Larmor precession of the nuclear spins. In this case, neither a spin excitation nor a spin polarization is required since the signal comes from fluctuating magnetic fields of the nuclear spins. We calculate the minimum detectable density (number) of the nuclear spins for the FQ with experimentally feasible parameters. We show that the minimum detectable density (number) of the nuclear spins with these approaches is around ${10}^{21}/{\mathrm{cm}}^{3}$ (${10}^{8}$) with an accumulation time of 1 s.

DOI
10.1103/physreva.101.052303

Related papers

Electron Spin Resonance Spectroscopy Using a Superconducting Flux Qubit

Hiraku Toida, Kosuke Kakuyanagi, William J. Munro +2 more

We use a superconducting flux qubit for the sensing application of electron spin resonance (ESR) spectroscopy.The superconducting flux qubit is a highly sensitive magnetometer with micrometer-scale spatial resolution.The sensitivity of our spectrometer is 400 spins/√Hz, and the sensing volume is 0.05 pL.This high sensitivity and high spatial resolution enable us to investigate a small number of electron spins in a microscale area.The spectrometer also obtains a wider ESR spectrum range with twoparameter (frequency and magnetic field) scanning.This enables us to refine the material parameters.

NTT technical review•Aug 1, 2019•1 citation

NMR imaging analogue of the individual qubit operations in superconducting flux-qubit chains

Toshiyuki Fujii, Shigemasa Matsuo, Noriyuki Hatakenaka

A solid-state quantum computer conventionally requires the control lines for each qubit to operate individually. This makes quantum circuits complicated, especially in multi-qubit systems. Here we propose a simple single-qubit operation in a superconducting flux-qubit chain without control lines in an analogy of the Nuclear Magnetic Resonance (NMR) imaging technique. A superconducting flux qubit can be regarded as an artificial atom with spin 1/2 that can be manipulated by an external magnetic field. To identify the location of each qubit in the qubit chain, a static field gradient is introduced along the qubit chain. This magnetic field gradient causes differences in the Zeeman frequencies of each separate qubit. This allows a large number of distinct qubits to be individually addressed. Single-qubit operations are then possible when the external electromagnetic frequency is adjusted to the resulting energy-level separation of the target qubit.

Journal of Physics Conference Series•Feb 1, 2009•0 citations

Nuclear magnetic resonance with dc SQUID (Super-conducting QUantum Interference Device) preamplifiers

N. Q. Fan, Michael B. Heaney, J.E. Clark +5 more

Sensitive radio-frequency (rf) amplifiers based on dc Superconducting QUantum Interface Devices (SQUIDS) are available for frequencies up to 200 MHz. At 4.2 K, the gain and noise temperature of a typical tuned amplifier are 18.6 +- 0.5 dB and 1.7 +- 0.5 K at 93 MHz. These amplifiers are being applied to a series of novel experiments on nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR). The high sensitivity of these amplifiers was demonstrated in the observation of ''nuclear spin noise'', the emission of photons by /sup 35/Cl nuclei in a state of zero polarization. In the more conventional experiments in which one applies a large rf pulse to the spins, a Q-spoiler, consisting of a series array of Josephson junctions, is used to reduce the Q of the input circuit to a very low value during the pulse. The Q-spoiler enables the circuit to recover quickly after the pulse, and has been used in an NQR experiment to achieve a sensitivity of about 2 /times/ 10/sup 16/ nuclear Bohr magnetons in a single free precession signal with a bandwidth of 10 kHz. In a third experiment, a sample containing /sup 35/Cl nuclei was placed in a capacitor and the signal detected electrically using a tuned SQUID amplifier and Q-spoiler. In this way, the electrical polarization induced by the precessing Cl nuclear quadrupole moments was detected: this is the inverse of the Stark effect in NQR. Two experiments involving NMR have been carried out. In the first, the 30 MHz resonance in /sup 119/Sn nuclei is detected with a tuned amplifier and Q-spoiler, and a single pulse resolution of 10/sup 18/ nuclear Bohr magnetons in a bandwidth of 25 kHz has been achieved. For the second, a low frequency NMR system has been developed that uses an untuned input circuit coupled to the SQUID. The resonance in /sup 195/Pt nuclei has been observed at 55 kHz in a field of 60 gauss. 23 refs., 11 figs.

•Aug 1, 1988•0 citations

Electron Spin Resonance Detected by Superconducting Circuits

Rangga P. Budoyo, Hiraku Toida, Shiro Saito

Superconducting circuits are promising components for future quantum information technologies such as quantum computing, quantum simulation, and quantum sensing. Superconducting quantum interference devices (SQUIDs) and superconducting flux qubits can be used as a sensitive magnetic field sensor to detect local electron spin resonance (ESR). These types of sensor are characterized by good sensitivity and high spatial resolution for electron spins. In fact, we have achieved a sensitivity of 20 spins/\(\sqrt{\text {Hz}}\) with a sensing volume of 6 fl combining a flux qubit and qubit readout using a Josephson bifurcation amplifier. As a demonstration, we measured the ESR spectrum of erbium electron spins in a Y\(_{2}\)SiO\(_{5}\) crystal and nitrogen vacancy centers in diamond. In both cases, we obtained reasonable electron spin parameters by fitting a simulation to the spectrum. In this way, we proved superconducting circuits to be promising magnetic field sensors for evaluating the properties of solid materials.

Quantum science and technology•Jan 1, 2021•1 citation

Quadrature-detected zero-to-ultralow-field nuclear magnetic resonance

Anne M. Fabricant, Florin Teleanu, Adam Ortmeier +6 more

We present the concept of quadrature-detected zero-to-ultralow-field nuclear magnetic resonance (QD ZULF NMR). Two orthogonal sensors, atomic optically pumped magnetometers, are used to separately detect components of oscillating sample magnetization, which are then combined into a quadrature signal. This approach enables the distinction of positive and negative resonance frequencies with respect to the laboratory frame---such that absolute signs of gyromagnetic ratios can be determined. In addition, QD ZULF NMR reduces peak density and overlap compared to ZULF NMR with single-axis detection, while providing richer information about nuclear-spin dynamics. As an illustration, we present experimental $J$-spectra for thermally polarized [$^{13}$C]-formic acid and [$^{13}$C]-methanol, compounds commonly used in ZULF NMR which represent XA and XA$_3$ spin systems, respectively. A theoretical framework describing QD ZULF NMR signals is provided.

quant-pharXiv:2610.14451•Oct 13, 2026

QUANTUM COMPUTATION WITH NUCLEAR MAGNETIC RESONANCE

Isaac L. Chuang

Nuclear spins have long coherence times and are easily manipulated using radio-frequency pulses. Single molecules, with spin-spin couplings provided by electronic bonds, are thus attractive physical systems for performing quantum computation. However, observation of small nuclear induction signals typically requires a large number, , of molecules. This presents fundamental problems for quantum computation, which traditionally requires pure state inputs, and strong measurements. Quantum computation with nuclear magnetic resonance was made possible by the invention of techniques which create effective pure states from thermal mixtures, and algorithmic steps which make strong measurements unnecessary. The theoretical basis for quantum computation with bulk materials, and experimental results demonstrating implementation of simple quantum gates and circuits are described.

WORLD SCIENTIFIC eBooks•Oct 1, 1998•4 citations
We theoretically analyze the performance of the nuclear magnetic resonance (NMR) spectroscopy with a superconducting flux qubit (FQ). Such NMR with the FQ is attractive because of the possibility to detect the relatively small number of nuclear spins in a local region (\ensuremath≈\ensuremathμm\ensuremath{\approx}\ensuremath{\mu}\mathrm{m}\ensuremath≈\ensuremathμm) with low temperatures (\ensuremath≈mK\ensuremath{\approx}\mathrm{mK}\ensuremath≈mK) and low magnetic fields (\ensuremath≈mT\ensuremath{\approx}\mathrm{mT}\ensuremath≈mT), in which other types of quantum sensing schemes cannot easily be accessed. A sample containing nuclear spins is directly attached on the FQ, and the FQ is used as a magnetometer to detect magnetic fields from the nuclear spins. Especially, we consider two types of approaches to NMR with the FQ. One of them is to use spatially inhomogeneous excitations of the nuclear spins, which are induced by a spatially asymmetric driving with radio-frequency (rf) pulses. Such an inhomogeneity causes a change in the dc magnetic flux penetrating a loop of the FQ, which can be detected by a standard Ramsey measurement on the FQ. The other approach is to use a dynamical decoupling on the FQ to measure ac magnetic fields induced by Larmor precession of the nuclear spins. In this case, neither a spin excitation nor a spin polarization is required since the signal comes from fluctuating magnetic fields of the nuclear spins. We calculate the minimum detectable density (number) of the nuclear spins for the FQ with experimentally feasible parameters. We show that the minimum detectable density (number) of the nuclear spins with these approaches is around 1021/cm3{10}^{21}/{\mathrm{cm}}^{3}1021/cm3 (108{10}^{8}108) with an accumulation time of 1 s.
We use a superconducting flux qubit for the sensing application of electron spin resonance (ESR) spectroscopy.The superconducting flux qubit is a highly sensitive magnetometer with micrometer-scale spatial resolution.The sensitivity of our spectrometer is 400 spins/√Hz, and the sensing volume is 0.05 pL.This high sensitivity and high spatial resolution enable us to investigate a small number of electron spins in a microscale area.The spectrometer also obtains a wider ESR spectrum range with twoparameter (frequency and magnetic field) scanning.This enables us to refine the material parameters.
A solid-state quantum computer conventionally requires the control lines for each qubit to operate individually. This makes quantum circuits complicated, especially in multi-qubit systems. Here we propose a simple single-qubit operation in a superconducting flux-qubit chain without control lines in an analogy of the Nuclear Magnetic Resonance (NMR) imaging technique. A superconducting flux qubit can be regarded as an artificial atom with spin 1/2 that can be manipulated by an external magnetic field. To identify the location of each qubit in the qubit chain, a static field gradient is introduced along the qubit chain. This magnetic field gradient causes differences in the Zeeman frequencies of each separate qubit. This allows a large number of distinct qubits to be individually addressed. Single-qubit operations are then possible when the external electromagnetic frequency is adjusted to the resulting energy-level separation of the target qubit.
Sensitive radio-frequency (rf) amplifiers based on dc Superconducting QUantum Interface Devices (SQUIDS) are available for frequencies up to 200 MHz. At 4.2 K, the gain and noise temperature of a typical tuned amplifier are 18.6 +- 0.5 dB and 1.7 +- 0.5 K at 93 MHz. These amplifiers are being applied to a series of novel experiments on nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR). The high sensitivity of these amplifiers was demonstrated in the observation of ''nuclear spin noise'', the emission of photons by /sup 35/Cl nuclei in a state of zero polarization. In the more conventional experiments in which one applies a large rf pulse to the spins, a Q-spoiler, consisting of a series array of Josephson junctions, is used to reduce the Q of the input circuit to a very low value during the pulse. The Q-spoiler enables the circuit to recover quickly after the pulse, and has been used in an NQR experiment to achieve a sensitivity of about 2 /times/ 10/sup 16/ nuclear Bohr magnetons in a single free precession signal with a bandwidth of 10 kHz. In a third experiment, a sample containing /sup 35/Cl nuclei was placed in a capacitor and the signal detected electrically using a tuned SQUID amplifier and Q-spoiler. In this way, the electrical polarization induced by the precessing Cl nuclear quadrupole moments was detected: this is the inverse of the Stark effect in NQR. Two experiments involving NMR have been carried out. In the first, the 30 MHz resonance in /sup 119/Sn nuclei is detected with a tuned amplifier and Q-spoiler, and a single pulse resolution of 10/sup 18/ nuclear Bohr magnetons in a bandwidth of 25 kHz has been achieved. For the second, a low frequency NMR system has been developed that uses an untuned input circuit coupled to the SQUID. The resonance in /sup 195/Pt nuclei has been observed at 55 kHz in a field of 60 gauss. 23 refs., 11 figs.
Superconducting circuits are promising components for future quantum information technologies such as quantum computing, quantum simulation, and quantum sensing. Superconducting quantum interference devices (SQUIDs) and superconducting flux qubits can be used as a sensitive magnetic field sensor to detect local electron spin resonance (ESR). These types of sensor are characterized by good sensitivity and high spatial resolution for electron spins. In fact, we have achieved a sensitivity of 20 spins/Hz\sqrt{\text {Hz}}Hz​ with a sensing volume of 6 fl combining a flux qubit and qubit readout using a Josephson bifurcation amplifier. As a demonstration, we measured the ESR spectrum of erbium electron spins in a Y2_{2}2​SiO5_{5}5​ crystal and nitrogen vacancy centers in diamond. In both cases, we obtained reasonable electron spin parameters by fitting a simulation to the spectrum. In this way, we proved superconducting circuits to be promising magnetic field sensors for evaluating the properties of solid materials.
We present the concept of quadrature-detected zero-to-ultralow-field nuclear magnetic resonance (QD ZULF NMR). Two orthogonal sensors, atomic optically pumped magnetometers, are used to separately detect components of oscillating sample magnetization, which are then combined into a quadrature signal. This approach enables the distinction of positive and negative resonance frequencies with respect to the laboratory frame---such that absolute signs of gyromagnetic ratios can be determined. In addition, QD ZULF NMR reduces peak density and overlap compared to ZULF NMR with single-axis detection, while providing richer information about nuclear-spin dynamics. As an illustration, we present experimental JJJ-spectra for thermally polarized [13^{13}13C]-formic acid and [13^{13}13C]-methanol, compounds commonly used in ZULF NMR which represent XA and XA3_33​ spin systems, respectively. A theoretical framework describing QD ZULF NMR signals is provided.
Nuclear spins have long coherence times and are easily manipulated using radio-frequency pulses. Single molecules, with spin-spin couplings provided by electronic bonds, are thus attractive physical systems for performing quantum computation. However, observation of small nuclear induction signals typically requires a large number, , of molecules. This presents fundamental problems for quantum computation, which traditionally requires pure state inputs, and strong measurements. Quantum computation with nuclear magnetic resonance was made possible by the invention of techniques which create effective pure states from thermal mixtures, and algorithmic steps which make strong measurements unnecessary. The theoretical basis for quantum computation with bulk materials, and experimental results demonstrating implementation of simple quantum gates and circuits are described.