arXiv:1905.00618 · Reviews of Modern Physics

Colloquium : Quantum limits to the energy resolution of magnetic field sensors

Morgan W. Mitchell, Silvana Palacios

Published Apr 28, 2020• 137 citations
arXivHTMLPDF

Abstract

Magnetometry, that is, the measurement of magnetic fields, has applications that range from brain imaging to exploration of the outer Solar System. The best magnetometry technologies achieve a sensitivity close to Planck's constant, the number that appears in the Heisenberg uncertainty relation. This Colloquium reviews what is known about quantum mechanical limits on field sensing, and identifies new sensing approaches that may break the current impasse in magnetic sensitivity.

DOI
10.1103/revmodphys.92.021001

Related papers

Quantum Thermodynamic Derivation of the Energy Resolution Limit in Magnetometry

Iannis K. Kominis

It was recently demonstrated that a multitude of realizations of several magnetic sensing technologies satisfy the energy resolution limit, which connects a quantity composed by the variance of the magnetic field estimate, the sensor volume and the measurement time, and having units of action, with ℏ. A first-principles derivation of this limit is still elusive. We here present such a derivation based on quantum thermodynamic arguments. We show that the energy resolution limit is a result of quantum thermodynamic work necessarily associated with quantum measurement and Landauer erasure, the work being exchanged with the magnetic field. We apply these considerations to atomic magnetometers, diamond magnetometers, and SQUIDs, spanning an energy resolution from 10^{0}ℏ to 10^{7}ℏ. This connection between quantum thermodynamics and magnetometry can help advance quantum sensing technologies towards even more sensitive devices.

arXiv:2405.14687•Physical Review Letters•Dec 26, 2024•10 citations

Quantum magnetometry for space

Cameron Deans, T. Valenzuela, Mark G. Bason

The ability to measure the magnetic fields around celestial bodies enables various insights into processes and phenomena deep within such bodies.The use of magnetometry in space missions dates back to the 1950s, and a number of different technologies have been used to measure these fields, ranging from fluxgates to Anisotropic Magneto Resistance (AMR) sensors.Optically-pumped magnetometers (OPMs) represent the state-of-the-art in magnetic field sensitivity. 1 Such sensors rely upon the interaction of laser light to spin polarise a warm vapour of neutral atoms.Detecting the precession of these spins, again with laser light, is a direct way to measure a magnetic field and is relatable to fundamental constants.Improvements in quantum technology within the last decade have led to the miniaturisation of these sensors.We have now reached the point where compact, lightweight, and low power devices offer greater sensitivity to magnetic fields than any other technology.In this work, we identify the following four key space application areas in which OPMs may offer significant advantages over existing technologies: Environments in which high sensitivity is needed at low magnetic fields (10s of nT), full vector read-out with high directional sensitivity and reduced SWaP compared to helium magnetometers, miniaturised and lightweight scalar magnetometers to complement vector fluxgate measurements, vector or scalar sensors that need high (40 dB) gradiometer performance.This work identifies OPM configurations for each area and makes a first estimate of size, weight and power requirements for each.By enabling improvements in magnetic field sensitivity, this represents an exciting prospect for precision magnetic field measurements while also saving mass and reducing complexity.

International Conference on Space Optics (ICSO)•Jul 12, 2023•6 citations

Metabolic quantum limit to the information capacity of magnetoencephalography

E. Gkoudinakis, S. Li, I. K. Kominis

Magnetoencephalography measures the magnetic fields generated by neural currents using quantum sensors such as superconducting quantum interference devices and atomic magnetometers. Here we combine the energy resolution limit of magnetic sensing with the metabolic power available to neural currents to derive a technology-independent bound on the information capacity of MEG. The bound factorizes into geometry, metabolism, and Planck's constant, and gives an estimated maximum information rate of 2.2~Mbit/s for representative human-brain parameters. Further, we show that the externally measurable magnetic field has a finite angular bandwidth, with high multipole components being geometrically attenuated and falling below the quantum-limited noise floor. This yields an information-limited spatial scale of order $1~{\rm cm}$ and renders the accessible measurement space effectively finite-dimensional. The energy resolution limit therefore defines an information-theoretic Nyquist scale for magnetoencephalography, beyond which denser spatial sampling provides redundant measurements rather than additional recoverable information. Since the energy resolution limit also makes the noise variance grow linearly with measurement bandwidth, temporal and spatial bandwidths compete, producing a fundamental spatio-temporal trade-off. These results show how quantum-limited measurements constrain the observable complexity and information content of noninvasive brain imaging, providing a quantitative link between fundamental physics and neuroscience.

physics.bio-phCross-listedarXiv:2511.06401•Physical Review Research•Nov 11, 2025•0 citations

The hunt for mineral resources with quantum magnetometers

Ronny Stolz, M. Schiffler, Michael Becken +2 more

Abstract Quantum sensing provides advanced technologies which significantly improve sensitivity and accuracy for sensing changes of motion, gravity, electric and magnetic field. Therein, quantum sensors for the detection of magnetic fields, so-called quantum magnetometers, are one of the most promising technological realizations. We firstly will provide a brief overview on methods in geophysical exploration benefitting from quantum magnetometers with resolution at the physical and technical limit. We will introduce recent developments on SQUID and OPM based sensors as specific implementations of a quantum magnetometer systems and application examples.

tm - Technisches Messen•Dec 14, 2023•10 citations

Quantum Sensing

Because of their extreme sensitivity to external fields, Rydberg atoms provide an excellent platform for detecting and measuring electric (and magnetic) fields. Quantum sensing exploits quantum properties, such as quantized energy levels, quantum coherence, and entanglement, to push the precision and sensitivity of measurements below classical limits. Interest in quantum sensing for electrometry and magnetometry has grown rapidly in recent years and is now an active area of research. Such sensors have the advantage that their response can be linked to fundamental constants that can be readily calculated to high precision and thus can themselves serve as calibration standards.

WORLD SCIENTIFIC (EUROPE) eBooks•May 5, 2026•0 citations

Ultrasensitive Magnetometer using a Single Atom

I. Baumgart, Jianming Cai, Alex Retzker +2 more

Precision sensing, and in particular high precision magnetometry, is a central goal of research into quantum technologies. For magnetometers, often trade-offs exist between sensitivity, spatial resolution, and frequency range. The precision, and thus the sensitivity of magnetometry, scales as 1/sqrt[T_{2}] with the phase coherence time T_{2} of the sensing system playing the role of a key determinant. Adapting a dynamical decoupling scheme that allows for extending T_{2} by orders of magnitude and merging it with a magnetic sensing protocol, we achieve a measurement sensitivity even for high frequency fields close to the standard quantum limit. Using a single atomic ion as a sensor, we experimentally attain a sensitivity of 4.6 pT/sqrt[Hz] for an alternating-current magnetic field near 14 MHz. Based on the principle demonstrated here, this unprecedented sensitivity combined with spatial resolution in the nanometer range and tunability from direct current to the gigahertz range could be used for magnetic imaging in as of yet inaccessible parameter regimes.

arXiv:1411.7893•Physical Review Letters•Jun 17, 2016•103 citations
Magnetometry, that is, the measurement of magnetic fields, has applications that range from brain imaging to exploration of the outer Solar System. The best magnetometry technologies achieve a sensitivity close to Planck's constant, the number that appears in the Heisenberg uncertainty relation. This Colloquium reviews what is known about quantum mechanical limits on field sensing, and identifies new sensing approaches that may break the current impasse in magnetic sensitivity.
It was recently demonstrated that a multitude of realizations of several magnetic sensing technologies satisfy the energy resolution limit, which connects a quantity composed by the variance of the magnetic field estimate, the sensor volume and the measurement time, and having units of action, with ℏ. A first-principles derivation of this limit is still elusive. We here present such a derivation based on quantum thermodynamic arguments. We show that the energy resolution limit is a result of quantum thermodynamic work necessarily associated with quantum measurement and Landauer erasure, the work being exchanged with the magnetic field. We apply these considerations to atomic magnetometers, diamond magnetometers, and SQUIDs, spanning an energy resolution from 10^{0}ℏ to 10^{7}ℏ. This connection between quantum thermodynamics and magnetometry can help advance quantum sensing technologies towards even more sensitive devices.
The ability to measure the magnetic fields around celestial bodies enables various insights into processes and phenomena deep within such bodies.The use of magnetometry in space missions dates back to the 1950s, and a number of different technologies have been used to measure these fields, ranging from fluxgates to Anisotropic Magneto Resistance (AMR) sensors.Optically-pumped magnetometers (OPMs) represent the state-of-the-art in magnetic field sensitivity. 1 Such sensors rely upon the interaction of laser light to spin polarise a warm vapour of neutral atoms.Detecting the precession of these spins, again with laser light, is a direct way to measure a magnetic field and is relatable to fundamental constants.Improvements in quantum technology within the last decade have led to the miniaturisation of these sensors.We have now reached the point where compact, lightweight, and low power devices offer greater sensitivity to magnetic fields than any other technology.In this work, we identify the following four key space application areas in which OPMs may offer significant advantages over existing technologies: Environments in which high sensitivity is needed at low magnetic fields (10s of nT), full vector read-out with high directional sensitivity and reduced SWaP compared to helium magnetometers, miniaturised and lightweight scalar magnetometers to complement vector fluxgate measurements, vector or scalar sensors that need high (40 dB) gradiometer performance.This work identifies OPM configurations for each area and makes a first estimate of size, weight and power requirements for each.By enabling improvements in magnetic field sensitivity, this represents an exciting prospect for precision magnetic field measurements while also saving mass and reducing complexity.
Magnetoencephalography measures the magnetic fields generated by neural currents using quantum sensors such as superconducting quantum interference devices and atomic magnetometers. Here we combine the energy resolution limit of magnetic sensing with the metabolic power available to neural currents to derive a technology-independent bound on the information capacity of MEG. The bound factorizes into geometry, metabolism, and Planck's constant, and gives an estimated maximum information rate of 2.2~Mbit/s for representative human-brain parameters. Further, we show that the externally measurable magnetic field has a finite angular bandwidth, with high multipole components being geometrically attenuated and falling below the quantum-limited noise floor. This yields an information-limited spatial scale of order 1 cm1~{\rm cm}1 cm and renders the accessible measurement space effectively finite-dimensional. The energy resolution limit therefore defines an information-theoretic Nyquist scale for magnetoencephalography, beyond which denser spatial sampling provides redundant measurements rather than additional recoverable information. Since the energy resolution limit also makes the noise variance grow linearly with measurement bandwidth, temporal and spatial bandwidths compete, producing a fundamental spatio-temporal trade-off. These results show how quantum-limited measurements constrain the observable complexity and information content of noninvasive brain imaging, providing a quantitative link between fundamental physics and neuroscience.
Abstract Quantum sensing provides advanced technologies which significantly improve sensitivity and accuracy for sensing changes of motion, gravity, electric and magnetic field. Therein, quantum sensors for the detection of magnetic fields, so-called quantum magnetometers, are one of the most promising technological realizations. We firstly will provide a brief overview on methods in geophysical exploration benefitting from quantum magnetometers with resolution at the physical and technical limit. We will introduce recent developments on SQUID and OPM based sensors as specific implementations of a quantum magnetometer systems and application examples.
Because of their extreme sensitivity to external fields, Rydberg atoms provide an excellent platform for detecting and measuring electric (and magnetic) fields. Quantum sensing exploits quantum properties, such as quantized energy levels, quantum coherence, and entanglement, to push the precision and sensitivity of measurements below classical limits. Interest in quantum sensing for electrometry and magnetometry has grown rapidly in recent years and is now an active area of research. Such sensors have the advantage that their response can be linked to fundamental constants that can be readily calculated to high precision and thus can themselves serve as calibration standards.
Precision sensing, and in particular high precision magnetometry, is a central goal of research into quantum technologies. For magnetometers, often trade-offs exist between sensitivity, spatial resolution, and frequency range. The precision, and thus the sensitivity of magnetometry, scales as 1/sqrt[T_{2}] with the phase coherence time T_{2} of the sensing system playing the role of a key determinant. Adapting a dynamical decoupling scheme that allows for extending T_{2} by orders of magnitude and merging it with a magnetic sensing protocol, we achieve a measurement sensitivity even for high frequency fields close to the standard quantum limit. Using a single atomic ion as a sensor, we experimentally attain a sensitivity of 4.6 pT/sqrt[Hz] for an alternating-current magnetic field near 14 MHz. Based on the principle demonstrated here, this unprecedented sensitivity combined with spatial resolution in the nanometer range and tunability from direct current to the gigahertz range could be used for magnetic imaging in as of yet inaccessible parameter regimes.