Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1903.02498 · Physical Review Letters

Engineering Quantum States of Matter for Atomic Clocks in Shallow Optical Lattices

Ross B. Hutson, Akihisa Goban, G. Edward Marti, Lindsay Sonderhouse, Christian Sanner, Jun Ye

Published Sep 17, 2019• 51 citations
arXivHTMLPDF

Abstract

We investigate the effects of stimulated scattering of optical lattice photons on atomic coherence times in a state-of-the art ^{87}Sr optical lattice clock. Such scattering processes are found to limit the achievable coherence times to less than 12 s (corresponding to a quality factor of 1×10^{16}), significantly shorter than the predicted 145(40) s lifetime of ^{87}Sr's excited clock state. We suggest that shallow, state-independent optical lattices with increased lattice constants can give rise to sufficiently small lattice photon scattering and motional dephasing rates as to enable coherence times on the order of the clock transition's natural lifetime. Not only should this scheme be compatible with the relatively high atomic density associated with Fermi-degenerate gases in three-dimensional optical lattices, but we anticipate that certain properties of various quantum states of matter-such as the localization of atoms in a Mott insulator-can be used to suppress dephasing due to tunneling.

DOI
10.1103/physrevlett.123.123401

Related papers

Atomic Coherence of 2 Minutes and Instability of 1.5 × 10 − 18 at 1 s in a Wannier-Stark Lattice Clock

Kyungtae Kim, Alexander Aeppli, William Warfield +3 more

We explore the limits of atomic coherence and measurement precision in a ^{87}Sr optical lattice clock. We perform a detailed characterization of key effects, including lattice Raman scattering and atomic collisions in a shallow lattice configuration, determining a 174(28) s ^{3}P_{0} clock state lifetime. Investigation of atomic coherence across a range of lattice depths and atomic densities reveals decoherence mechanisms related to photon scattering and atomic interaction. At a reduced density, we observe a coherence time of 118(9) s, approaching the fundamental limit set by spontaneous emission. Guided by this coherence understanding, we demonstrate a clock instability for an atomic ensemble of 1.5×10^{-18} at 1 s in fractional frequency units. Our results are important for further advancing the state of the art of an optical lattice clock for fundamental physics applications.

arXiv:2505.06444•Physical Review Letters•Aug 1, 2025•16 citations

Floquet Engineering Hz-Level Rabi Spectra in Shallow Optical Lattice Clock

Mo-Juan Yin, Xiaotong Lu, Ting Li +4 more

Quantum metrology with ultrahigh precision usually requires atoms prepared in an ultrastable environment with well-defined quantum states. Thus, in optical lattice clock systems deep lattice potentials are used to trap ultracold atoms. However, decoherence, induced by Raman scattering and higher order light shifts, can significantly be reduced if atomic clocks are realized in shallow optical lattices. On the other hand, in such lattices, tunneling among different sites can cause additional dephasing and strongly broadening of the Rabi spectrum. Here, in our experiment, we periodically drive a shallow ^{87}Sr optical lattice clock. Counterintuitively, shaking the system can deform the wide broad spectral line into a sharp peak with 5.4 Hz linewidth. With careful comparison between the theory and experiment, we demonstrate that the Rabi frequency and the Bloch bands can be tuned, simultaneously and independently. Our work not only provides a different idea for quantum metrology, such as building shallow optical lattice clock in outer space, but also paves the way for quantum simulation of new phases of matter by engineering exotic spin orbit couplings.

arXiv:2110.07169•Physical Review Letters•Feb 17, 2022•36 citations

Lattice-induced photon scattering in an optical lattice clock

Sören Dörscher, R. Schwarz, Ali Al-Masoudi +3 more

Off-resonant scattering of lattice laser radiation by ${}^{87}$Sr atoms in the two states ${}^{1}{S}_{0}$ and ${}^{3}{P}_{0}$ and its effect on clock operation are investigated. It is found that Raman scattering eventually limits the achievable frequency instability and thus limits the useful interrogation time in optical lattice clocks at presently used lattice depths.

arXiv:1802.02945•Physical Review A•Jun 25, 2018•59 citations

An Aubry-André localized optical lattice clock

Shuo Ma, Anke Stöltzel, Bennett Christensen +5 more

Optical lattice clocks in space could improve satellite navigation systems and enable new tests of fundamental physics, including gravitational-wave detection and tests of relativity. In microgravity, atoms can tunnel to degenerate neighboring lattice sites, broadening the clock transition and limiting coherence times. We demonstrate Aubry-André localization in a bichromatic optical lattice formed by two magic-wavelength lasers, suppressing tunneling in a horizontal lattice clock emulating free fall. We recover a Fourier-limited clock Rabi spectrum and measure Ramsey coherence times of up to 2 s in shallow lattices, with up to 100-fold improvement over the delocalized regime. These results establish Aubry-André localization as a practical route to controlling tunneling in future space-based clocks, and open a path to operating terrestrial clocks at shallower lattice depths.

physics.atom-phCross-listedarXiv:2610.17499•Oct 14, 2026•0 citations

Enhancing Optical Lattice Clock Coherence Times with Erasure Conversion

Shuo Ma, Jonathan Dolde, Xin Zheng +6 more

Increasing coherent interrogation times is central to advancing the precision of optical clocks. Synchronous differential optical clock comparisons have now demonstrated atomic coherence times that far exceed the coherence time of the clock laser. While atom coherence times are then primarily limited by errors induced by lattice Raman scattering, excited clock state radiative decay, and broadening from two-body collisions, many of these errors take the atoms out of the clock transition subspace, and can therefore be converted into “erasure” errors if the appropriate readout scheme is employed. Here we experimentally demonstrate a hyperfine-resolved readout technique for 87 Sr optical lattice clocks that mitigates decoherence from Raman scattering induced by the lattice as well as radiative decay. By employing hyperfine-resolved readout in synchronous differential comparisons between 87 Sr ensembles with both Ramsey and spin-echo spectroscopy sequences, we achieve enhanced atomic coherence times exceeding 100 and 150 s, respectively, enabling longer coherent measurements without a reduction in performance. We anticipate that this hyperfine-resolved readout technique will benefit applications of state-of-the-art optical lattice clock comparisons in which the coherence times are constrained by Raman scattering or radiative decay.

arXiv:2505.06437•PRX Quantum•Nov 19, 2025•4 citations

Optical lattice clock with atoms confined in a shallow trap

P. Lemonde, Peter Wolf

We study the trap depth requirement for the realization of an optical clock using atoms confined in a lattice. We show that site-to-site tunneling leads to a residual sensitivity to the atom dynamics hence requiring large depths [$(50\text{--}100){E}_{r}$ for Sr] to avoid any frequency shift or line broadening of the atomic transition at the ${10}^{\ensuremath{-}17}\text{--}{10}^{\ensuremath{-}18}$ level. Such large depths and the corresponding laser power may, however, lead to difficulties (e.g., higher-order light shifts, two-photon ionization, technical difficulties) and therefore one would like to operate the clock in much shallower traps. To circumvent this problem we propose the use of an accelerated lattice. Acceleration lifts the degeneracy between adjacents potential wells which strongly inhibits tunneling. We show that using the Earth's gravity, much shallower traps (down to $5{E}_{r}$ for Sr) can be used for the same accuracy goal.

arXiv:physics/0504080•Physical Review A•Sep 16, 2005•120 citations
We investigate the effects of stimulated scattering of optical lattice photons on atomic coherence times in a state-of-the art ^{87}Sr optical lattice clock. Such scattering processes are found to limit the achievable coherence times to less than 12 s (corresponding to a quality factor of 1×10^{16}), significantly shorter than the predicted 145(40) s lifetime of ^{87}Sr's excited clock state. We suggest that shallow, state-independent optical lattices with increased lattice constants can give rise to sufficiently small lattice photon scattering and motional dephasing rates as to enable coherence times on the order of the clock transition's natural lifetime. Not only should this scheme be compatible with the relatively high atomic density associated with Fermi-degenerate gases in three-dimensional optical lattices, but we anticipate that certain properties of various quantum states of matter-such as the localization of atoms in a Mott insulator-can be used to suppress dephasing due to tunneling.
We explore the limits of atomic coherence and measurement precision in a ^{87}Sr optical lattice clock. We perform a detailed characterization of key effects, including lattice Raman scattering and atomic collisions in a shallow lattice configuration, determining a 174(28) s ^{3}P_{0} clock state lifetime. Investigation of atomic coherence across a range of lattice depths and atomic densities reveals decoherence mechanisms related to photon scattering and atomic interaction. At a reduced density, we observe a coherence time of 118(9) s, approaching the fundamental limit set by spontaneous emission. Guided by this coherence understanding, we demonstrate a clock instability for an atomic ensemble of 1.5×10^{-18} at 1 s in fractional frequency units. Our results are important for further advancing the state of the art of an optical lattice clock for fundamental physics applications.
Quantum metrology with ultrahigh precision usually requires atoms prepared in an ultrastable environment with well-defined quantum states. Thus, in optical lattice clock systems deep lattice potentials are used to trap ultracold atoms. However, decoherence, induced by Raman scattering and higher order light shifts, can significantly be reduced if atomic clocks are realized in shallow optical lattices. On the other hand, in such lattices, tunneling among different sites can cause additional dephasing and strongly broadening of the Rabi spectrum. Here, in our experiment, we periodically drive a shallow ^{87}Sr optical lattice clock. Counterintuitively, shaking the system can deform the wide broad spectral line into a sharp peak with 5.4 Hz linewidth. With careful comparison between the theory and experiment, we demonstrate that the Rabi frequency and the Bloch bands can be tuned, simultaneously and independently. Our work not only provides a different idea for quantum metrology, such as building shallow optical lattice clock in outer space, but also paves the way for quantum simulation of new phases of matter by engineering exotic spin orbit couplings.
Off-resonant scattering of lattice laser radiation by 87{}^{87}87Sr atoms in the two states 1S0{}^{1}{S}_{0}1S0​ and 3P0{}^{3}{P}_{0}3P0​ and its effect on clock operation are investigated. It is found that Raman scattering eventually limits the achievable frequency instability and thus limits the useful interrogation time in optical lattice clocks at presently used lattice depths.
Optical lattice clocks in space could improve satellite navigation systems and enable new tests of fundamental physics, including gravitational-wave detection and tests of relativity. In microgravity, atoms can tunnel to degenerate neighboring lattice sites, broadening the clock transition and limiting coherence times. We demonstrate Aubry-André localization in a bichromatic optical lattice formed by two magic-wavelength lasers, suppressing tunneling in a horizontal lattice clock emulating free fall. We recover a Fourier-limited clock Rabi spectrum and measure Ramsey coherence times of up to 2 s in shallow lattices, with up to 100-fold improvement over the delocalized regime. These results establish Aubry-André localization as a practical route to controlling tunneling in future space-based clocks, and open a path to operating terrestrial clocks at shallower lattice depths.
Increasing coherent interrogation times is central to advancing the precision of optical clocks. Synchronous differential optical clock comparisons have now demonstrated atomic coherence times that far exceed the coherence time of the clock laser. While atom coherence times are then primarily limited by errors induced by lattice Raman scattering, excited clock state radiative decay, and broadening from two-body collisions, many of these errors take the atoms out of the clock transition subspace, and can therefore be converted into “erasure” errors if the appropriate readout scheme is employed. Here we experimentally demonstrate a hyperfine-resolved readout technique for 87 Sr optical lattice clocks that mitigates decoherence from Raman scattering induced by the lattice as well as radiative decay. By employing hyperfine-resolved readout in synchronous differential comparisons between 87 Sr ensembles with both Ramsey and spin-echo spectroscopy sequences, we achieve enhanced atomic coherence times exceeding 100 and 150 s, respectively, enabling longer coherent measurements without a reduction in performance. We anticipate that this hyperfine-resolved readout technique will benefit applications of state-of-the-art optical lattice clock comparisons in which the coherence times are constrained by Raman scattering or radiative decay.
We study the trap depth requirement for the realization of an optical clock using atoms confined in a lattice. We show that site-to-site tunneling leads to a residual sensitivity to the atom dynamics hence requiring large depths [(50–100)Er(50\text{--}100){E}_{r}(50–100)Er​ for Sr] to avoid any frequency shift or line broadening of the atomic transition at the ${10}^{\ensuremath{-}17}\text{--}{10}^{\ensuremath{-}18}$ level. Such large depths and the corresponding laser power may, however, lead to difficulties (e.g., higher-order light shifts, two-photon ionization, technical difficulties) and therefore one would like to operate the clock in much shallower traps. To circumvent this problem we propose the use of an accelerated lattice. Acceleration lifts the degeneracy between adjacents potential wells which strongly inhibits tunneling. We show that using the Earth's gravity, much shallower traps (down to 5Er5{E}_{r}5Er​ for Sr) can be used for the same accuracy goal.