arXiv:1704.03531 · Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields

Decoherence and degradation of squeezed states in quantum filter cavities

P. Kwee, John Miller, Tomoki Isogai, L. Barsotti, M. Evans

Published Sep 5, 2014• 98 citations
arXivHTMLPDF

Abstract

Squeezed states of light have been successfully employed in interferometric gravitational-wave detectors to reduce quantum noise, thus becoming one of the most promising options for extending the astrophysical reach of the generation of detectors currently under construction worldwide. In these advanced instruments, quantum noise will limit sensitivity over the entire detection band. Therefore, to obtain the greatest benefit from squeezing, the injected squeezed state must be filtered using a long-storage-time optical resonator, or ``filter cavity,'' so as to realize a frequency-dependent rotation of the squeezed quadrature. While the ultimate performance of a filter cavity is determined by its storage time, several practical decoherence and degradation mechanisms limit the experimentally achievable quantum noise reduction. In this paper we develop an analytical model to explore these mechanisms in detail. As an example, we apply our results to the 16 m filter cavity design currently under consideration for the Advanced LIGO interferometers.

DOI
10.1103/physrevd.90.062006

Related papers

Frequency-Dependent Squeezing for Advanced LIGO

Lee P. McCuller, Chris Whittle, D. Ganapathy +13 more

The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."

arXiv:2003.13443•Physical Review Letters•Apr 28, 2020•191 citations

Applications of long storage time optical cavities

Tomoki Isogai

Optical precision measurements have become one of the most important tools in physics to test the fundamental laws and to probe the universe around us. Often such experiments require high finesse cavities, and optical loss in these cavities is a critical parameter. In particular, for those cavities that deal with quantum systems, minimizing the cavity loss is crucial because any loss can easily degrade the fragile quantum states. One such example is a quantum noise filter cavity for gravitational wave (GW) detectors, where an optical cavity is necessary for producing frequency-dependent squeezed states of light to improve the sensitivity over their broad audioband frequency [1]. To test the feasibility of quantum noise filter cavities for GW detectors, we characterized the optical loss of state-of-the-art mirrors using a 2 m long high-finesse cavity. Using multiple loss measurement techniques, we studied loss dependence on laser beam sizes and positions. Within the 1 to 3 mm beam spot size we measured, we found that the mirror loss is almost constant at around 5 ppm, and that the loss depends more on the beam position on the mirror than on the beam size 121. While intra-cavity optical loss is one of the key parameters informing the design of quantum noise filter cavities, we also need to account for other quantum noise degradation mechanisms such as the phase noise, losses outside of the cavity, and mode-matching. We developed an analytical model of frequency-dependent squeezing with a quantum noise filter cavity to explore the practical degradation mechanisms in detail 131. Finally, by coupling a squeezed light source to the 2 m long high-finesse cavity, we demonstrated frequency-dependent squeezed states where 6 dB of squeezing in the squeezed quadrature was rotated by 90 degrees in the audio frequency band 141. The techniques used are directly applicable to squeezed light sources for GW detectors, and the measurements validated the model. The loss measurement results, the analytical model, and this demonstration, are now the basis for the design of a realistic quantum noise filter cavity for use in GW detectors in the near future to improve their sensitivity.

•Jan 1, 2016•1 citation

Performance of multiple filter-cavity schemes for frequency-dependent squeezing in gravitational-wave detectors

J. Ding, E. Capocasa, I. -L. Ahrend +3 more

Gravitational-wave detectors use state-of-the-art quantum technologies to reduce the noise induced by vacuum fluctuations, via injection of squeezed states of light. Future detectors, such as Einstein Telescope, may require the use of two filter cavities or a three-mirror coupled filter cavity to achieve a complex rotation of the squeezing ellipse, in order to reduce the quantum noise over the whole detector bandwidth. In this work, we compare the theoretical feasibility and performances of these two optical layouts and their resilience with respect to different degradation sources (optical losses, mismatching, locking precision), analytically and numerically. We extend previous analysis on squeezing degradation and find that the coupled cavity scheme provides similar or better performances than the two-cavity option, in terms of resilience with respect to imperfections and optical losses. We further highlight the role of mode-mismatch phases in limiting squeezing. Finally, we propose a possible two-step implementation scheme for Einstein Telescope using a single filter cavity that can be possibly upgraded into a coupled filter cavity.

arXiv:2506.02222•Physical review. D/Physical review. D.•Oct 28, 2025•4 citations

Squeezed light for gravitational wave astronomy

H. Vahlbruch

During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.

•Jan 1, 2008•12 citations

Advanced techniques for squeezed-light-enhanced gravitational-wave detection

J. Gniesmer

Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.

•Jan 1, 2019•0 citations

Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors

Yang Zhao, N. Aritomi, E. Capocasa +20 more

The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo, and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.

arXiv:2003.10672•Physical Review Letters•Apr 28, 2020•110 citations
Squeezed states of light have been successfully employed in interferometric gravitational-wave detectors to reduce quantum noise, thus becoming one of the most promising options for extending the astrophysical reach of the generation of detectors currently under construction worldwide. In these advanced instruments, quantum noise will limit sensitivity over the entire detection band. Therefore, to obtain the greatest benefit from squeezing, the injected squeezed state must be filtered using a long-storage-time optical resonator, or ``filter cavity,'' so as to realize a frequency-dependent rotation of the squeezed quadrature. While the ultimate performance of a filter cavity is determined by its storage time, several practical decoherence and degradation mechanisms limit the experimentally achievable quantum noise reduction. In this paper we develop an analytical model to explore these mechanisms in detail. As an example, we apply our results to the 16 m filter cavity design currently under consideration for the Advanced LIGO interferometers.
The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."
Optical precision measurements have become one of the most important tools in physics to test the fundamental laws and to probe the universe around us. Often such experiments require high finesse cavities, and optical loss in these cavities is a critical parameter. In particular, for those cavities that deal with quantum systems, minimizing the cavity loss is crucial because any loss can easily degrade the fragile quantum states. One such example is a quantum noise filter cavity for gravitational wave (GW) detectors, where an optical cavity is necessary for producing frequency-dependent squeezed states of light to improve the sensitivity over their broad audioband frequency [1]. To test the feasibility of quantum noise filter cavities for GW detectors, we characterized the optical loss of state-of-the-art mirrors using a 2 m long high-finesse cavity. Using multiple loss measurement techniques, we studied loss dependence on laser beam sizes and positions. Within the 1 to 3 mm beam spot size we measured, we found that the mirror loss is almost constant at around 5 ppm, and that the loss depends more on the beam position on the mirror than on the beam size 121. While intra-cavity optical loss is one of the key parameters informing the design of quantum noise filter cavities, we also need to account for other quantum noise degradation mechanisms such as the phase noise, losses outside of the cavity, and mode-matching. We developed an analytical model of frequency-dependent squeezing with a quantum noise filter cavity to explore the practical degradation mechanisms in detail 131. Finally, by coupling a squeezed light source to the 2 m long high-finesse cavity, we demonstrated frequency-dependent squeezed states where 6 dB of squeezing in the squeezed quadrature was rotated by 90 degrees in the audio frequency band 141. The techniques used are directly applicable to squeezed light sources for GW detectors, and the measurements validated the model. The loss measurement results, the analytical model, and this demonstration, are now the basis for the design of a realistic quantum noise filter cavity for use in GW detectors in the near future to improve their sensitivity.
Gravitational-wave detectors use state-of-the-art quantum technologies to reduce the noise induced by vacuum fluctuations, via injection of squeezed states of light. Future detectors, such as Einstein Telescope, may require the use of two filter cavities or a three-mirror coupled filter cavity to achieve a complex rotation of the squeezing ellipse, in order to reduce the quantum noise over the whole detector bandwidth. In this work, we compare the theoretical feasibility and performances of these two optical layouts and their resilience with respect to different degradation sources (optical losses, mismatching, locking precision), analytically and numerically. We extend previous analysis on squeezing degradation and find that the coupled cavity scheme provides similar or better performances than the two-cavity option, in terms of resilience with respect to imperfections and optical losses. We further highlight the role of mode-mismatch phases in limiting squeezing. Finally, we propose a possible two-step implementation scheme for Einstein Telescope using a single filter cavity that can be possibly upgraded into a coupled filter cavity.
During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.
Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.
The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo, and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.