Lee P. McCuller, Chris Whittle, D. Ganapathy, Kentaro Komori, M. Tse, Álvaro Fernández-Galiana, L. Barsotti, Peter K Fritschel, Myron E MacInnis, Fabrice Matichard, K. Mason, N. Mavalvala, Richard K Mittleman, Haocun Yu, Michael E. Zucker, M. Evans
The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."
The first detection of gravitational waves by the Laser Interferometer Gravitational-Wave Observatory (LIGO) in 2015 launched the era of gravitational-wave astronomy. The quest for gravitational-wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light, is being used to improve the shot-noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above ∼50 Hz. Below this frequency, quantum backaction, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30 Hz, using a 16-m-long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."
Abstract Quantum noise is limiting the sensitivity of ground based gravitational wave detectors both at high frequency, in the form of shot noise, and low frequency, in the form of radiation pressure noise. In the last observing run, the injection of frequency independent squeezing improved Virgo and LIGO sensitivities at high frequency, slightly worsening the performance at low frequency. A broadband quantum noise reduction can be achieved using frequency dependent squeezing, i. e. rotating the vacuum squeezed ellipse below 100 Hz by reflecting the squeezed vacuum off a Fabry–Perot cavity, called filter cavity. The frequency-dependent squeezed quadrature rotation with rotation frequency around a few tens of Hz has been proven at National Astronomical Observatory of Japan (NAOJ) and at Massachusetts Institute of Technology (MIT). The experiment at NAOJ uses the former TAMA facility, a 300 meter long filter cavity, reproducing in scale the ones planned to be installed in Virgo and LIGO. Once the frequency dependent squeezing is produced, it has to be injected into the interferometer. This interface is not trivial, since it requires the installation of additional benches and a 285 meter long cavity (in Advanced Virgo Plus) and also to couple the rotating squeezed vacuum with the detector. An important issue which can worsen the performance of frequency dependent squeezing or directly the interferometer sensitivity is the stray light. To avoid the propagation of additional stray light, we traced the ghost beam on squeezing benches, inside linking tubes and inside the filter cavity and several diaphragms and baffles will be installed to limit this problem.
The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo, and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.
Direct detection of gravitational waves will require
earth based detectors to measure strains of the order 10-21, at
frequencies of 100 Hz, a sensitivity that has been accomplished
with the initial generation of LIGO interferometric gravitational
wave detectors. A new generation of detectors currently under
construction is designed improve on the sensitivity of the initial
detectors by about a factor of 10. The quantum nature of light will
limit the sensitivity of these Advanced LIGO interferometers at
most frequencies; new approaches to reducing the quantum noise will
be needed to improve the sensitivity further. This quantum noise
originates from the vacuum fluctuations that enter the unused port
of the interferometer and interfere with the laser light. Vacuum
fluctuations have the minimum noise allowed by Heisenberg's
uncertainty principle, [Delta]X1 [Delta]X2 >/=1, where the two
quadratures X1 and X2 are non-commuting observables responsible for
the two forms of quantum noise, shot noise and radiation pressure
noise. By replacing the vacuum fluctuations entering the
interferometer with squeezed states, which have lower noise in one
quadrature than the vacuum state, we have reduced the shot noise of
a LIGO interferometer. The sensitivity to gravitational waves
measured during this experiment represents the best sensitivity
achieved to date at frequencies above 200 Hz, and possibly the
first time that squeezing has been measured in an interferometer at
frequencies below 700 Hz. The possibility that injection of
squeezed states could introduce environmental noise couplings that
would degrade the crucial but fragile low frequency sensitivity of
a LIGO interferometer has been a major concern in planning to
implement squeezing as part of baseline interferometer operations.
These results demonstrate that squeezing is compatible with the low
frequency sensitivity of a full scale gravitational wave
interferometer. We also investigated the limits to the level of
squeezing observed, including optical losses and fluctuations of
the squeezing angle. The lessons learned should allow for
responsible planning to implement squeezing in Advanced LIGO,
either as an alternative to high power operation or an early
upgrade to improve the sensitivity. This thesis is available at
DSpace@MIT and has LIGO document number P1300006.
Direct detection of gravitational waves will require earth based detectors to measure strains of the order 10−21, at frequencies of 100 Hz, a sensitivity that has been accomplished with the initial generation of LIGO interferometric gravitational wave detectors. A new generation of detectors currently under construction is designed improve on the sensitivity of the initial detectors by about a factor of 10. The quantum nature of light will limit the sensitivity of these Advanced LIGO interferometers at most frequencies; new approaches to reducing the quantum noise will be needed to improve the sensitivity further. This quantum noise originates from the vacuum fluctuations that enter the unused port of the interferometer and interfere with the laser light. Vacuum fluctuations have the minimum noise allowed by Heisenberg’s uncertainty principle, ∆X1∆X2 ≥ 1, where the two quadratures X1 and X2 are non-commuting observables responsible for the two forms of quantum noise, shot noise and radiation pressure noise. By replacing the vacuum fluctuations entering the interferometer with squeezed states, which have lower noise in one quadrature than the vacuum state, we have reduced the shot noise of a LIGO interferometer. The sensitivity to gravitational waves measured during this experiment represents the best sensitivity achieved to date at frequencies above 200 Hz, and possibly the first time that squeezing has been measured in an interferometer at frequencies below 700 Hz. The possibility that injection of squeezed states could introduce environmental noise couplings that would degrade the crucial but fragile low frequency sensitivity of a LIGO interferometer has been a major concern in planning to implement squeezing as part of baseline interferometer operations. These results demonstrate that squeezing is compatible with the low frequency sensitivity of a full scale gravitational wave interferometer. We also investigated the limits to the level of squeezing observed, including optical losses and fluctuations of the squeezing angle. The lessons learned should allow for responsible planning to implement squeezing in Advanced LIGO, either as an alternative to high power operation or an early upgrade to improve the sensitivity. This thesis is available at DSpace@MIT and has LIGO document number P1300006. Thesis Supervisor: Nergis Mavalvala Title: Professor of Physics
Quantum vacuum fluctuations impose strict limits on precision displacement measurements, those of interferometric gravitational-wave detectors among them. Introducing squeezed states into an interferometer's readout port can improve the sensitivity of the instrument, leading to richer astrophysical observations. In recent years, this technique has been used to improve the sensitivity of the GEO600 [1011 and the Initial LIGO detector at Hanford, WA [102]. Squeezed states could be employed in advanced gravitational-wave detectors, such as Advanced LIGO, to further push the limits of the observable gravitational wave universe. To maximize the benefit from squeezing, environmentally induced disturbances such as back scattering and angular jitter need to be mitigated. Also, optomechanical interactions dictate that the quadrature of the squeezed vacuum state must rotate by 900 at around 50 Hz in order to achieve a broadband sensitivity improvement for Advanced LIGO. In this thesis we describe a series of experiments that lead to a ultra-high vacuum (UHV) compatible, low phase noise, and frequency-dependent squeezed vacuum source required for Advanced LIGO and future gravitational-wave detectors. In order to develop the required technology, two proof-of-principal experiments were conducted. In the first experiment, we built a UHV compatible squeezed vacuum source and homodyne readout and operated them in UHV conditions. We also commissioned a control scheme that achieved a record low 1.30-7 mrad of phase noise. This is a nearly tenfold improvement over previously reported measurements with audio-band squeezed vacuum sources. In the second experiment we used a 2-m-long, high-finesse optical resonator to produce frequency-dependent squeezed quadrature rotation around 1.2kHz. This demonstration of audio-band frequency-dependent squeezing uses technology and methods that are scalable to the required rotation frequency for Advance LIGO, firmly establishing the viability of this technique for application in current and future gravitational-wave detectors. We conclude with a discussion of the implications of these results for squeezing enhancement in Advanced LIGO and beyond.
The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.