Abstract We present a systematic study of the effects of shielding on the internal quality factors ( Q i ) of Al and TiN microwave resonators designed for use in quantum coherent circuits. Measurements were performed in an adiabatic demagnetization refrigerator, where typical magnetic fields of 200 μ T are present at the unshielded sample stage. Radiation shielding consisted of 100 and 500 mK Cu cans coated with infrared absorbing epoxy. Magnetic shields consisted of Cryoperm 10 and Sn plating of the Cu cans. A 2.7 K radiation can and coaxial thermalization filters were present in all measurements. TiN samples with Q i = 1.3 × 10 6 at 100 mK exhibited no significant variation in quality factor when tested with limited shielding. In contrast, Al resonators showed improved Q i with successive shielding, with the largest gains obtained from the addition of the first radiation and magnetic shields and saturating before the addition of Sn plating infrared absorbing epoxy.
Abstract We present a systematic study of the effects of shielding on the internal quality factors ( Q i ) of Al and TiN microwave resonators designed for use in quantum coherent circuits. Measurements were performed in an adiabatic demagnetization refrigerator, where typical magnetic fields of 200 μ T are present at the unshielded sample stage. Radiation shielding consisted of 100 and 500 mK Cu cans coated with infrared absorbing epoxy. Magnetic shields consisted of Cryoperm 10 and Sn plating of the Cu cans. A 2.7 K radiation can and coaxial thermalization filters were present in all measurements. TiN samples with Q i = 1.3 × 10 6 at 100 mK exhibited no significant variation in quality factor when tested with limited shielding. In contrast, Al resonators showed improved Q i with successive shielding, with the largest gains obtained from the addition of the first radiation and magnetic shields and saturating before the addition of Sn plating infrared absorbing epoxy.
In this master's thesis, I present the design, fabrication, and characterisation of superconducting microwave resonators. These resonators are quarter-wavelength coplanar waveguide resonators, operating at resonance frequencies between 4 GHz and 8 GHz. This kind of resonator is a key component in several applications, ranging from quantum computation devices to parametric amplifiers. Minimising the losses (achieving high internal quality factors) in these resonators is important to maximise performance of the applications they are used for. During the thesis work, we have studied several possible changes to improve the resonator quality.\n\nFabrication of the resonators was done in the Nanofabrication Laboratory at Chalmers University of Technology, and consist of the following steps: cleaning a sapphire or silicon wafer, depositing a layer of superconducting niobium, photolithography, and etching the waveguide. We then measured the resonators in a cryogen-free dilution refrigerator, at a temperature of 10 mK. The measurements consisted of a power sweep, in order to quantify the quality factor at high and low excitation powers. As an example, the first resonator we fabricated had a quality factor of 4.3 x 10^4 at high power (about 10^5 photons in the resonator), and quality factor of 3.7 x 10^4 at the single-photon level.\n\nWe then investigated different loss mechanisms that we expect to negatively affect the quality factor, and how to reduce this loss. Firstly, to reduce radiation losses and magnetic vortex losses, we reduced the lateral dimensions of the resonator. Secondly, as two-level system (TLS) losses are believed to mainly reside at the surfaces of the materials and interfaces between them, we etched into the substrate to selectively move a part of the TLS away from the resonator. We also studied the effect of the meandering of the resonator on the quality factor, as well as using two different etching gasses.\n\nBy gathering all this data, we were then able to compare the different combinations to see the effect of the changing parameters. In conclusion, the reduced lateral dimensions and the removal of part of the substrate indeed reduce the losses, as expected from the theory. We also found interesting behaviour with regards to the meandering, namely that having a meandered structure negatively affects the quality factor.\n\nCombining all results, we can give a guideline for the fabrication of resonators in the future, which gave us a quality factor up to 4.9 x 10^5 at high excitation power, and 3.0 x 10^5 at the single photon level.
Abstract We systematically study the performance of compact lumped element planar microwave Nb70Ti30N (NbTiN) resonators operating at 5 GHz in external in-plane magnetic fields up to 440 mT, a broad temperature regime from 2.2 K up to 13 K, as well as mK temperatures. For comparison, the resonators have been fabricated on thermally oxidized and pristine, (001) oriented silicon substrates. When operating the resonators in the multi-photon regime at T = 2.2 K, we find internal quality factors Q int ≃ 2 × 105 for NbTiN resonators grown on pristine Si substrates. In addition, we investigate the Q-factors of the resonators on pristine Si substrates at millikelvin temperatures to assess their applicability for quantum applications. We find Q int ≃ 2 × 105 in the single photon regime and Q int ≃ 5 × 105 in the high power regime at T = 7 mK. From the excellent performance of our resonators over a broad temperature and magnetic field range, we conclude that NbTiN deposited on Si (100) substrates, where the surface oxide has been removed, constitutes a promising material platform for electron spin resonance and ferromagnetic resonance experiments using superconducting planar microwave resonators.
Understanding the impact of ionizing radiation on superconducting microwave resonators is essential for improving the coherence of superconducting quantum processors. In this work, we examine the response of Nb coplanar waveguide (CPW) resonators—with single-photon intrinsic quality factors on the order of several hundred thousand—to γ radiation from a Cs-137 source. We observed no significant degradation in the internal quality factor during the irradiation of Nb CPW resonators on sapphire or Si(100) substrates.
Microwave resonators with high quality factors have enabled many recent breakthroughs with superconducting qubits and photon detectors, typically operated in shielded environments to reduce the ambient magnetic field. Insufficient shielding or pulsed control fields can introduce vortices, leading to reduced quality factors, although increased pinning can mitigate this effect. A narrow slot etched into the resonator surface provides a straightforward method for pinning enhancement without otherwise affecting the resonator. Resonators patterned with such a slot exhibited over an order of magnitude reduction in the excess loss due to vortices compared with identical resonators from the same film with no slot.
We describe the fabrication and measurement of microwave coplanar waveguide resonators with internal quality factors above 107 at high microwave powers and over 106 at low powers, with the best low power results approaching 2×106, corresponding to ∼1 photon in the resonator. These quality factors are achieved by controllably producing very smooth and clean interfaces between the resonators’ aluminum metallization and the underlying single crystal sapphire substrate. Additionally, we describe a method for analyzing the resonator microwave response, with which we can directly determine the internal quality factor and frequency of a resonator embedded in an imperfect measurement circuit.
Abstract Quantum bits (qubits) with long coherence times are an important element for the implementation of medium- and large-scale quantum computers. In the case of superconducting planar qubits, understanding and improving qubits’ quality can be achieved by studying superconducting planar resonators. In this paper, we fabricate and characterize coplanar waveguide resonators made from aluminum thin films deposited on silicon substrates. We perform three different substrate surface treatments prior to aluminum deposition: one chemical treatment based on a hydrofluoric acid clean; one physical treatment consisting of a thermal annealing at 880 °C in high vacuum; and one combined treatment comprising both the chemical and the physical treatments. The aim of these treatments is to remove the two-level state (TLS) defects hosted by the native oxides residing at the various samples’ interfaces. We first characterize the fabricated samples through cross-sectional tunneling electron microscopy, acquiring electron energy loss spectroscopy maps of the samples’ cross sections. These measurements show that both the chemical and the physical treatments almost entirely remove native silicon oxide from the substrate surface and that their combination results in the cleanest interface. Additionally, we analyze the effects of the various substrate treatments on the roughness of the silicon surface by means of atomic force microscopy surface morphology mapping. We then study the quality of the resonators by means of microwave measurements in the ‘quantum regime’, i.e., at a temperature T ∼ 10 mK and at a mean microwave photon number 〈 n ph 〉 ∼ 1 . In this regime, we find that both surface treatments independently improve the resonator’s intrinsic quality factor by ≈172%. The highest quality factor is obtained for the combined treatment, Q i ≈ 0.82 million, corresponding to an improvement by ≈256%. Finally, we find that the TLS quality factor averaged over a time period of 3 h is ∼3 million at 〈 n ph 〉 ∼ 10 , indicating that substrate surface engineering can potentially reduce the TLS loss below other losses such as quasiparticle loss and flux noise.