Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1606.02188 · Physical Review A

Heisenberg scaling of imaging resolution by coherent enhancement

Robert McConnell, Guang Hao Low, Theodore J. Yoder, Colin Bruzewicz, Isaac L. Chuang, John Chiaverini, Jeremy Sage

Published Nov 9, 2017• 4 citations
arXivHTMLPDF

Abstract

Classical imaging works by scattering photons from an object to be imaged, and achieves resolution scaling as $1/\sqrt{t}$, with $t$ the imaging time. By contrast, the laws of quantum mechanics allow one to utilize quantum coherence to obtain imaging resolution that can scale as quickly as $1/t$ -- the so-called ``Heisenberg limit.'' However, ambiguities in the obtained signal often preclude taking full advantage of this quantum enhancement, while imaging techniques designed to be unambiguous often lose this optimal Heisenberg scaling. Here we demonstrate an imaging technique which combines unambiguous detection of the target with Heisenberg scaling of the resolution. We also demonstrate a binary search algorithm which can efficiently locate a coherent target using the technique, resolving a target trapped ion to within 0.3% of the $1/{e}^{2}$ diameter of the excitation beam.

DOI
10.1103/physreva.96.051801

Related papers

Quantum Imaging by Coherent Enhancement

Guang Hao Low, Theodore J. Yoder, Isaac L. Chuang

Conventional wisdom dictates that to image the position of fluorescent atoms or molecules, one should stimulate as much emission and collect as many photons as possible. That is, in this classical case, it has always been assumed that the coherence time of the system should be made short, and that the statistical scaling ∼1/√t defines the resolution limit for imaging time t. However, here we show in contrast that given the same resources, a long coherence time permits a higher resolution image. In this quantum regime, we give a procedure for determining the position of a single two-level system and demonstrate that the standard errors of our position estimates scale at the Heisenberg limit as ∼1/t, a quadratic, and notably optimal, improvement over the classical case.

arXiv:1409.7993•Physical Review Letters•Mar 11, 2015•17 citations

Super-resolution quantum imaging at the Heisenberg limit

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated $N$-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of $1/N$. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.

arXiv:1712.02200•Optica•Sep 20, 2018•106 citations

Super-Resolution Quantum Imaging at the Heisenberg Limit

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated N-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.

Conference on Lasers and Electro-Optics•Jan 1, 2018•12 citations

Quantum sensor miniaturization prospectus

Gerald N. Gilbert, Michael Hamrick, Yaakov S. Weinstein +2 more

The quantum mechanical phenomenon of entanglement can be utilized to beat the the Rayleigh limit, the classical bound on image resolution. This is done by entangling the photons that are used as the signal states. Using entanglement, the best possible image resolution is instead given by the Heisenberg limit, an improvement proportional to the number of entangled photons in the signal. Here, we present a novel application of entanglement by inverting the above procedure. We show that the resolution obtained by an imaging system utilizing separable photons can be achieved by an imaging system making use of entangled photons, but with the advantage of a smaller aperture. This results in a smaller, lighter imaging system. Smaller imaging systems can be especially valuable in satellite imaging where weight and size play a vital role.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 24, 2009•7 citations

Super-resolution quantum microscopy at the Heisenberg limit

Xin Tong, Zhe He, Yide Zhang +2 more

We introduce quantum microscopy by coincidence (QMC) featuring balanced pathlengths, which facilitates super-resolution imaging at the Heisenberg limit, drastically boosting speed and contrast-to-noise ratio (CNR) compared to existing wide-field quantum imaging methods. QMC uses correlated photons traversing symmetric paths, behaving like a photon with half the wavelength for twice the resolution. It withstands 155 times stronger stray light than classical signals, promising non-destructive bioimaging. Our approach propels quantum imaging to microscopic scale by imaging cancer cells. Experimental and theoretical results endorse this balanced pathlength configuration as a path to quantum-enhanced coincidence imaging at the Heisenberg limit.

Optical and Quantum Sensing and Precision Metrology II•Mar 13, 2024•0 citations

Super-resolution quantum imaging at the Heisenberg limit (Conference Presentation)

Bänz Bessire, Manuel Unternährer, Leonardo Gasparini +3 more

The method of optical centroid measurement (OCM) has shown to exhibit spatial super-resolution with enhancements at the Heisenberg limit in plane wave interference experiments. In this work, the OCM method is for the first time used in an imaging setting where actual object features are observed. The OCM result is rederived in a near-field imaging formalism for a general imaging system and in full 2-D treatment. Analogies to coherent and incoherent imaging are shown Moreover, coherent OCM imaging is experimentally implemented for photon number N = 2, where an experimental setup is presented which allows to generate the desired entangled two-photon state containing the super-resolved image. This state is then imaged by an imaging system with a finite resolution defined by its point spread function (PSF). The centroid measurement of the two-photon states delivers then an image with a width of the PSF reduced by a factor 2 corresponding to the Heisenberg limit. In the experiment, the object is illuminated by a continuous-wave pump laser centred at 405nm with an output power of 30mW. A 4-f lens system images the object to the state preparation output plane. In the far-field plane between the lenses, a 5mm long periodically poled KTiOPO4 non-linear crystal generates photon pairs at 810nm by type-0, frequency-degenerate and collinear spontaneous parametric down-conversion. This generated OCM state is then imaged by a single lens and detected in coincidence by a fully digital 2-D sensor array with single-photon sensitivity and per-pixel sub-nanosecond time resolution. The OCM state is spectrally filtered at 810nm. Its imaging capability is compared to classical light sources including spatially coherent, monochromatic illumination at 405nm and 810 nm, as well as spatially incoherent light at 810 nm. The former is implemented using collimated lasers, the latter is a thermal light source spectrally filtered at 810 nm. The PSF of the different light sources are compared at low numerical aperture by imaging a focal point of 25μm Gaussian waist radius.

SPIE Quantum Technologies•May 29, 2018•0 citations
Classical imaging works by scattering photons from an object to be imaged, and achieves resolution scaling as 1/t1/\sqrt{t}1/t​, with ttt the imaging time. By contrast, the laws of quantum mechanics allow one to utilize quantum coherence to obtain imaging resolution that can scale as quickly as 1/t1/t1/t -- the so-called ``Heisenberg limit.'' However, ambiguities in the obtained signal often preclude taking full advantage of this quantum enhancement, while imaging techniques designed to be unambiguous often lose this optimal Heisenberg scaling. Here we demonstrate an imaging technique which combines unambiguous detection of the target with Heisenberg scaling of the resolution. We also demonstrate a binary search algorithm which can efficiently locate a coherent target using the technique, resolving a target trapped ion to within 0.3% of the 1/e21/{e}^{2}1/e2 diameter of the excitation beam.
Conventional wisdom dictates that to image the position of fluorescent atoms or molecules, one should stimulate as much emission and collect as many photons as possible. That is, in this classical case, it has always been assumed that the coherence time of the system should be made short, and that the statistical scaling ∼1/√t defines the resolution limit for imaging time t. However, here we show in contrast that given the same resources, a long coherence time permits a higher resolution image. In this quantum regime, we give a procedure for determining the position of a single two-level system and demonstrate that the standard errors of our position estimates scale at the Heisenberg limit as ∼1/t, a quadratic, and notably optimal, improvement over the classical case.
Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated NNN-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N1/N1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.
Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated N-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.
The quantum mechanical phenomenon of entanglement can be utilized to beat the the Rayleigh limit, the classical bound on image resolution. This is done by entangling the photons that are used as the signal states. Using entanglement, the best possible image resolution is instead given by the Heisenberg limit, an improvement proportional to the number of entangled photons in the signal. Here, we present a novel application of entanglement by inverting the above procedure. We show that the resolution obtained by an imaging system utilizing separable photons can be achieved by an imaging system making use of entangled photons, but with the advantage of a smaller aperture. This results in a smaller, lighter imaging system. Smaller imaging systems can be especially valuable in satellite imaging where weight and size play a vital role.
We introduce quantum microscopy by coincidence (QMC) featuring balanced pathlengths, which facilitates super-resolution imaging at the Heisenberg limit, drastically boosting speed and contrast-to-noise ratio (CNR) compared to existing wide-field quantum imaging methods. QMC uses correlated photons traversing symmetric paths, behaving like a photon with half the wavelength for twice the resolution. It withstands 155 times stronger stray light than classical signals, promising non-destructive bioimaging. Our approach propels quantum imaging to microscopic scale by imaging cancer cells. Experimental and theoretical results endorse this balanced pathlength configuration as a path to quantum-enhanced coincidence imaging at the Heisenberg limit.
The method of optical centroid measurement (OCM) has shown to exhibit spatial super-resolution with enhancements at the Heisenberg limit in plane wave interference experiments. In this work, the OCM method is for the first time used in an imaging setting where actual object features are observed. The OCM result is rederived in a near-field imaging formalism for a general imaging system and in full 2-D treatment. Analogies to coherent and incoherent imaging are shown Moreover, coherent OCM imaging is experimentally implemented for photon number N = 2, where an experimental setup is presented which allows to generate the desired entangled two-photon state containing the super-resolved image. This state is then imaged by an imaging system with a finite resolution defined by its point spread function (PSF). The centroid measurement of the two-photon states delivers then an image with a width of the PSF reduced by a factor 2 corresponding to the Heisenberg limit. In the experiment, the object is illuminated by a continuous-wave pump laser centred at 405nm with an output power of 30mW. A 4-f lens system images the object to the state preparation output plane. In the far-field plane between the lenses, a 5mm long periodically poled KTiOPO4 non-linear crystal generates photon pairs at 810nm by type-0, frequency-degenerate and collinear spontaneous parametric down-conversion. This generated OCM state is then imaged by a single lens and detected in coincidence by a fully digital 2-D sensor array with single-photon sensitivity and per-pixel sub-nanosecond time resolution. The OCM state is spectrally filtered at 810nm. Its imaging capability is compared to classical light sources including spatially coherent, monochromatic illumination at 405nm and 810 nm, as well as spatially incoherent light at 810 nm. The former is implemented using collimated lasers, the latter is a thermal light source spectrally filtered at 810 nm. The PSF of the different light sources are compared at low numerical aperture by imaging a focal point of 25μm Gaussian waist radius.