Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

SPIE Quantum Technologies

Super-resolution quantum imaging at the Heisenberg limit (Conference Presentation)

Bänz Bessire, Manuel Unternährer, Leonardo Gasparini, Majid Zarghami, Matteo Perenzoni, André Stefanov

Published May 29, 2018• 0 citations
Publisher

Abstract

The method of optical centroid measurement (OCM) has shown to exhibit spatial super-resolution with enhancements at the Heisenberg limit in plane wave interference experiments. In this work, the OCM method is for the first time used in an imaging setting where actual object features are observed. The OCM result is rederived in a near-field imaging formalism for a general imaging system and in full 2-D treatment. Analogies to coherent and incoherent imaging are shown Moreover, coherent OCM imaging is experimentally implemented for photon number N = 2, where an experimental setup is presented which allows to generate the desired entangled two-photon state containing the super-resolved image. This state is then imaged by an imaging system with a finite resolution defined by its point spread function (PSF). The centroid measurement of the two-photon states delivers then an image with a width of the PSF reduced by a factor 2 corresponding to the Heisenberg limit. In the experiment, the object is illuminated by a continuous-wave pump laser centred at 405nm with an output power of 30mW. A 4-f lens system images the object to the state preparation output plane. In the far-field plane between the lenses, a 5mm long periodically poled KTiOPO4 non-linear crystal generates photon pairs at 810nm by type-0, frequency-degenerate and collinear spontaneous parametric down-conversion. This generated OCM state is then imaged by a single lens and detected in coincidence by a fully digital 2-D sensor array with single-photon sensitivity and per-pixel sub-nanosecond time resolution. The OCM state is spectrally filtered at 810nm. Its imaging capability is compared to classical light sources including spatially coherent, monochromatic illumination at 405nm and 810 nm, as well as spatially incoherent light at 810 nm. The former is implemented using collimated lasers, the latter is a thermal light source spectrally filtered at 810 nm. The PSF of the different light sources are compared at low numerical aperture by imaging a focal point of 25μm Gaussian waist radius.

DOI
10.1117/12.2309773

Related papers

Super-Resolution Quantum Imaging at the Heisenberg Limit

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated N-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.

Conference on Lasers and Electro-Optics•Jan 1, 2018•12 citations

Super-resolution with Fourier measurements

S. A. Wadood, Shaurya Aarav, Kevin Liang +1 more

Resolving sources beyond the diffraction limit is important in imaging, communications, and metrology. Current image-based methods of super-resolution require phase information (either of the source points or an added filter) and perfect alignment with the centroid of the object. Both inhibit the practical application of these methods, as uniform motion and/or relative jitter destroy their assumptions. Here, we show that measuring intensity in the Fourier plane enables super-resolution without any of the issues of image-based methods. We start with the shift-invariance of the Fourier transform and the observation that the two-point position problem ${x_1,x_2}$ in the near field corresponds to the single-point wavenumber problem $k\ =2π/(x_2-x_1)$ in the far field. We consider the full range of mutual coherence and show that for fully coherent sources, the Fourier method saturates the quantum limit, i.e. it gives the best possible measurement. Similar results hold for sub-Rayleigh constellations of $N$ sources, which can act collectively as a spatially averaged metasurface and/or individually as elements of a phased-array antenna. The theory paves the way to merge Fourier optics with super-resolution techniques, enabling experimental devices that are both simpler and more robust than previous designs.

physics.opticsCross-listedarXiv:2511.06098•Nov 11, 2025•2 citations

Super-resolution quantum imaging at the Heisenberg limit

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated $N$-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of $1/N$. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.

arXiv:1712.02200•Optica•Sep 20, 2018•106 citations

Resolution-enhanced quantum imaging by centroid estimation of biphotons

Ermes Toninelli, Paul‐Antoine Moreau, Thomas Gregory +4 more

The spatial resolution of an optical system is limited by diffraction. Various schemes have been proposed to achieve resolution enhancement by employing either a scanning source/detector configuration or a two-photon response of the object. Here, we experimentally demonstrate a full-field resolution-enhancing scheme, based on the centroid estimation of spatially quantum-correlated biphotons. Our standard-quantum-limited scheme is able to image a general non-fluorescing object, using low-energy and low-intensity infrared illumination (i.e., with <0.001 photon per pixel per frame at 710 nm), achieving 41% of the theoretically available resolution enhancement. Images of real-world objects are shown for visual comparison, in which the classically bound resolution is surpassed using our technically straightforward quantum-imaging scheme.

Optica•Mar 8, 2019•87 citations

Quantum Spatial Superresolution by Optical Centroid Measurements

Heedeuk Shin, Kam Wai Clifford Chan, Hye Jeong Chang +1 more

Quantum lithography (QL) has been suggested as a means of achieving enhanced spatial resolution for optical imaging, but its realization has been held back by the low multiphoton detection rates of recording materials. Recently, an optical centroid measurement (OCM) procedure was proposed as a way to obtain spatial resolution enhancement identical to that of QL but with higher detection efficiency (M. Tsang, Phys. Rev. Lett. 102, 253601 (2009)). Here we describe a variation of the OCM method with still higher detection efficiency based on the use of photon-number-resolving detection. We also report laboratory results for two-photon interference. We compare these results with those of the standard QL method based on multiphoton detection and show that the new method leads to superresolution but with higher detection efficiency.

arXiv:1105.2312•Physical Review Letters•Aug 19, 2011•63 citations

Super-resolution microscopy with spatial modes of light

José Inácio da Costa Filho

The resolution of imaging devices is ultimately limited by the diffraction of light. This limit can be circumvented by exploiting near-field phenomena, non-linearities of the sample or specific illumination schemes, which led to the recent explosion of optical super-resolution techniques. However, it would be desirable to reach the nanoscale in the most general way possible, with far-field linear imaging of uniformly illuminated samples. In the last few years, the answer to that came with the field of quantum-inspired super-resolution (QISR), where quantum metrological techniques were used to find novel measurement schemes that, beyond the conventional direct imaging of light, would achieve higher precisions. Interestingly, these ideas would always in some way or another involve transverse spatial modes of light. This thesis presents our work on the subject, with novel theoretical and experimental results. Firstly, we develop the traditional theory of QISR, with has mostly focused on either the estimation of separation of two point sources or on geometric moments of samples. Then, we introduce our own results on optical imaging of general distributions of point sources, in a step to take QISR from toy examples to real imaging scenarios. Secondly, we apply all the concepts studied on a experimental, proof-of-principle implementation of a QISR scheme dubbed Hermite-Gaussian Microscopy (HGM), which uses heterodyne detection with several Hermite-Gaussian modes as local oscillator in order to reconstruct the object sample and achieve super-resolution. We report the techniques necessary for the manipulation of spatial modes of light, as well as our results, where we demonstrated 2D imaging with twofold resolution enhancement beyond the diffraction limit.

•Jan 1, 2021•0 citations
The method of optical centroid measurement (OCM) has shown to exhibit spatial super-resolution with enhancements at the Heisenberg limit in plane wave interference experiments. In this work, the OCM method is for the first time used in an imaging setting where actual object features are observed. The OCM result is rederived in a near-field imaging formalism for a general imaging system and in full 2-D treatment. Analogies to coherent and incoherent imaging are shown Moreover, coherent OCM imaging is experimentally implemented for photon number N = 2, where an experimental setup is presented which allows to generate the desired entangled two-photon state containing the super-resolved image. This state is then imaged by an imaging system with a finite resolution defined by its point spread function (PSF). The centroid measurement of the two-photon states delivers then an image with a width of the PSF reduced by a factor 2 corresponding to the Heisenberg limit. In the experiment, the object is illuminated by a continuous-wave pump laser centred at 405nm with an output power of 30mW. A 4-f lens system images the object to the state preparation output plane. In the far-field plane between the lenses, a 5mm long periodically poled KTiOPO4 non-linear crystal generates photon pairs at 810nm by type-0, frequency-degenerate and collinear spontaneous parametric down-conversion. This generated OCM state is then imaged by a single lens and detected in coincidence by a fully digital 2-D sensor array with single-photon sensitivity and per-pixel sub-nanosecond time resolution. The OCM state is spectrally filtered at 810nm. Its imaging capability is compared to classical light sources including spatially coherent, monochromatic illumination at 405nm and 810 nm, as well as spatially incoherent light at 810 nm. The former is implemented using collimated lasers, the latter is a thermal light source spectrally filtered at 810 nm. The PSF of the different light sources are compared at low numerical aperture by imaging a focal point of 25μm Gaussian waist radius.
Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated N-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.
Resolving sources beyond the diffraction limit is important in imaging, communications, and metrology. Current image-based methods of super-resolution require phase information (either of the source points or an added filter) and perfect alignment with the centroid of the object. Both inhibit the practical application of these methods, as uniform motion and/or relative jitter destroy their assumptions. Here, we show that measuring intensity in the Fourier plane enables super-resolution without any of the issues of image-based methods. We start with the shift-invariance of the Fourier transform and the observation that the two-point position problem x1,x2{x_1,x_2}x1​,x2​ in the near field corresponds to the single-point wavenumber problem k =2π/(x2−x1)k\ =2π/(x_2-x_1)k =2π/(x2​−x1​) in the far field. We consider the full range of mutual coherence and show that for fully coherent sources, the Fourier method saturates the quantum limit, i.e. it gives the best possible measurement. Similar results hold for sub-Rayleigh constellations of NNN sources, which can act collectively as a spatially averaged metasurface and/or individually as elements of a phased-array antenna. The theory paves the way to merge Fourier optics with super-resolution techniques, enabling experimental devices that are both simpler and more robust than previous designs.
Quantum imaging exploits the spatial correlations between photons to image object features with a higher resolution than a corresponding classical light source could achieve. Using a quantum correlated NNN-photon state, the method of optical centroid measurement (OCM) was shown to exhibit a resolution enhancement by improving the classical Rayleigh limit by a factor of 1/N1/N1/N. In this work, the theory of OCM is formulated within the framework of an imaging formalism and is implemented in an exemplary experiment by means of a conventional entangled photon pair source. The expected resolution enhancement of a factor of two is demonstrated. The here presented experiment allows for single-shot operation without scanning or iteration to reproduce the object in the image plane. Thereby, photon detection is performed with a newly developed integrated time-resolving detector array. Multi-photon interference effects responsible for the observed resolution enhancement are discussed and possible alternative implementation possibilities for higher photon number are proposed.
The spatial resolution of an optical system is limited by diffraction. Various schemes have been proposed to achieve resolution enhancement by employing either a scanning source/detector configuration or a two-photon response of the object. Here, we experimentally demonstrate a full-field resolution-enhancing scheme, based on the centroid estimation of spatially quantum-correlated biphotons. Our standard-quantum-limited scheme is able to image a general non-fluorescing object, using low-energy and low-intensity infrared illumination (i.e., with <0.001 photon per pixel per frame at 710 nm), achieving 41% of the theoretically available resolution enhancement. Images of real-world objects are shown for visual comparison, in which the classically bound resolution is surpassed using our technically straightforward quantum-imaging scheme.
Quantum lithography (QL) has been suggested as a means of achieving enhanced spatial resolution for optical imaging, but its realization has been held back by the low multiphoton detection rates of recording materials. Recently, an optical centroid measurement (OCM) procedure was proposed as a way to obtain spatial resolution enhancement identical to that of QL but with higher detection efficiency (M. Tsang, Phys. Rev. Lett. 102, 253601 (2009)). Here we describe a variation of the OCM method with still higher detection efficiency based on the use of photon-number-resolving detection. We also report laboratory results for two-photon interference. We compare these results with those of the standard QL method based on multiphoton detection and show that the new method leads to superresolution but with higher detection efficiency.
The resolution of imaging devices is ultimately limited by the diffraction of light. This limit can be circumvented by exploiting near-field phenomena, non-linearities of the sample or specific illumination schemes, which led to the recent explosion of optical super-resolution techniques. However, it would be desirable to reach the nanoscale in the most general way possible, with far-field linear imaging of uniformly illuminated samples. In the last few years, the answer to that came with the field of quantum-inspired super-resolution (QISR), where quantum metrological techniques were used to find novel measurement schemes that, beyond the conventional direct imaging of light, would achieve higher precisions. Interestingly, these ideas would always in some way or another involve transverse spatial modes of light. This thesis presents our work on the subject, with novel theoretical and experimental results. Firstly, we develop the traditional theory of QISR, with has mostly focused on either the estimation of separation of two point sources or on geometric moments of samples. Then, we introduce our own results on optical imaging of general distributions of point sources, in a step to take QISR from toy examples to real imaging scenarios. Secondly, we apply all the concepts studied on a experimental, proof-of-principle implementation of a QISR scheme dubbed Hermite-Gaussian Microscopy (HGM), which uses heterodyne detection with several Hermite-Gaussian modes as local oscillator in order to reconstruct the object sample and achieve super-resolution. We report the techniques necessary for the manipulation of spatial modes of light, as well as our results, where we demonstrated 2D imaging with twofold resolution enhancement beyond the diffraction limit.