Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1605.05071 · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Maximizing the information gain of a single ion microscope using bayes experimental design

Georg Jacob, Karin Groot-Berning, Ulrich G. Poschinger, Ferdinand Schmidt‐Kaler, Kilian Singer

Published Apr 29, 2016• 1 citation
arXivHTMLPDF

Abstract

We demonstrate nanoscopic transmission microscopy, using a deterministic single particle source, and compare the resulting images in terms of signal-to-noise ratio with those of conventional Poissonian sources. Our source is realized by deterministic extraction of laser-cooled calcium ions from a Paul trap. Gating by the extraction event allows for the suppression of detector dark counts by six orders of magnitude. Using the Bayes experimental design method, the deterministic characteristics of this source are harnessed to maximize information gain, when imaging structures with a parametrizable transmission function. We demonstrate such optimized imaging by determining parameter values of one and two dimensional transmissive structures.

DOI
10.1117/12.2227745

Related papers

Maximizing the Information Gain of a Single Ion Microscope using Bayes Experimental Design

Georg Jacob, Karin Groot-Berning, G Poschinger Ulrich +2 more

We demonstrate nanoscopic transmission microscopy, using a deterministic single particle source, and compare the resulting images in terms of signal-to-noise ratio with those of conventional Poissonian sources. Our source is realized by deterministic extraction of laser-cooled calcium ions from a Paul trap. Gating by the extraction event allows for the suppression of detector dark counts by six orders of magnitude. Using the Bayes experimental design method, the deterministic characteristics of this source are harnessed to maximize information gain, when imaging structures with a parametrizable transmission function. We demonstrate such optimized imaging by determining parameter values of one and two dimensional transmissive structures.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 1, 2016•1 citation

Single particle microscopy with nanometer resolution

Jacob, Georg, Karin Groot-Berning, Wolf, Sebastian +5 more

We experimentally demonstrate nanoscopic transmission microscopy relying on a deterministic single particle source. This increases the signal-to-noise ratio with respect to conventional microscopy methods, which employ Poissonian particle sources. We use laser-cooled ions extracted from a Paul trap, and demonstrate remote imaging of transmissive objects with a resolution of 8.6 $\pm$ 2.0nm and a minimum two-sample deviation of the beam position of 1.5nm. Detector dark counts can be suppressed by 6 orders of magnitudes through gating by the extraction event. The deterministic nature of our source enables an information-gain driven approach to imaging. We demonstrate this by performing efficient beam characterization based on a Bayes experiment design method.

arXiv:1405.6480•May 26, 2014•7 citations

Transmission Microscopy with Nanometer Resolution Using a Deterministic Single Ion Source

Georg Jacob, Karin Groot-Berning, Sebastian Wolf +6 more

We realize a single particle microscope by using deterministically extracted laser-cooled ^{40}Ca^{+} ions from a Paul trap as probe particles for transmission imaging. We demonstrate focusing of the ions to a spot size of 5.8±1.0 nm and a minimum two-sample deviation of the beam position of 1.5 nm in the focal plane. The deterministic source, even when used in combination with an imperfect detector, gives rise to a fivefold increase in the signal-to-noise ratio as compared with conventional Poissonian sources. Gating of the detector signal by the extraction event suppresses dark counts by 6 orders of magnitude. We implement a Bayes experimental design approach to microscopy in order to maximize the gain in spatial information. We demonstrate this method by determining the position of a 1 μm circular hole structure to a precision of 2.7 nm using only 579 probe particles.

arXiv:1512.00347•Physical Review Letters•Jul 20, 2016•58 citations

Optimised focusing ion optics for an ultracold deterministic single ion source targeting nm resolution

Robert Fickler, Wolfgang Schnitzler, Norbert M. Linke +2 more

Using a segmented ion trap with mK laser-cooled ions we have realised a novel single ion source which can deterministically deliver a wide range of ion species, isotopes or ionic molecules [Schnitzler et al. Phys. Rev. Lett. 2009, 102, 070501]. Experimental data is discussed in detail and compared with numerical simulations of ion trajectories. For the novel ion source we numerically investigate the influence of various extraction parameters on fluctuations in velocity and position of the beam. We present specialised ion optics and show from numerical simulations that a nm spatial resolution is achievable. The Paul trap, which is used as a single ion source, together with the presented ion optics, constitutes a promising candidate for a deterministic ion implantation method for applications in solid state quantum computing or classical nano-electronic devices.

arXiv:0903.3425•Journal of Modern Optics•Aug 19, 2009•5 citations

Deterministic single-photon source from a single ion

H. G. Barros, Andreas Stute, Tracy E. Northup +3 more

We realize a deterministic single-photon source from one and the same calcium ion interacting with a high-finesse optical cavity. Photons are created in the cavity with efficiency 88±17%, a tenfold improvement over previous cavity-ion sources. Results of the second-order correlation function are presented, demonstrating a high suppression of two-photon events limited only by background counts. The cavity photon pulse shape is obtained, with good agreement between experiment and simulation. Moreover, theoretical analysis of the temporal evolution of the atomic populations provides relevant information about the dynamics of the process and opens the way to future investigations of a coherent atom–photon interface.

arXiv:0905.2885•New Journal of Physics•Oct 2, 2009•153 citations

Laser-cooled ion source for an ultrahigh-precision single NV center creation

Hosaka Koichi, Iizawa Masatomi, Seiji Hosoya +13 more

Deterministic ion implantation and color-center creation methods at the nanometer scale provide a route towards scalable quantum information processing. For this purpose, we have developed an inherently deterministic single-ion implantation method based on a linear Paul trap (LPT) as a single-ion source since the laser-cooling technique can be applied to the trap system to obtain ultralow-emittance ions and manipulate single ions one by one . Doubly charged nitrogen ions (N2+) produced in a sputter ion source is introduced into the LPT and sympathetically cooled with laser-cooled calcium ions (Ca+). Both the sputter ion source and the LPT chamber are elevated to +50kV for the 100keV-implantation of doubly charged single ions into a grounded diamond crystal.

•Jul 24, 2024•0 citations
We demonstrate nanoscopic transmission microscopy, using a deterministic single particle source, and compare the resulting images in terms of signal-to-noise ratio with those of conventional Poissonian sources. Our source is realized by deterministic extraction of laser-cooled calcium ions from a Paul trap. Gating by the extraction event allows for the suppression of detector dark counts by six orders of magnitude. Using the Bayes experimental design method, the deterministic characteristics of this source are harnessed to maximize information gain, when imaging structures with a parametrizable transmission function. We demonstrate such optimized imaging by determining parameter values of one and two dimensional transmissive structures.
We demonstrate nanoscopic transmission microscopy, using a deterministic single particle source, and compare the resulting images in terms of signal-to-noise ratio with those of conventional Poissonian sources. Our source is realized by deterministic extraction of laser-cooled calcium ions from a Paul trap. Gating by the extraction event allows for the suppression of detector dark counts by six orders of magnitude. Using the Bayes experimental design method, the deterministic characteristics of this source are harnessed to maximize information gain, when imaging structures with a parametrizable transmission function. We demonstrate such optimized imaging by determining parameter values of one and two dimensional transmissive structures.
We experimentally demonstrate nanoscopic transmission microscopy relying on a deterministic single particle source. This increases the signal-to-noise ratio with respect to conventional microscopy methods, which employ Poissonian particle sources. We use laser-cooled ions extracted from a Paul trap, and demonstrate remote imaging of transmissive objects with a resolution of 8.6 ±\pm± 2.0nm and a minimum two-sample deviation of the beam position of 1.5nm. Detector dark counts can be suppressed by 6 orders of magnitudes through gating by the extraction event. The deterministic nature of our source enables an information-gain driven approach to imaging. We demonstrate this by performing efficient beam characterization based on a Bayes experiment design method.
We realize a single particle microscope by using deterministically extracted laser-cooled ^{40}Ca^{+} ions from a Paul trap as probe particles for transmission imaging. We demonstrate focusing of the ions to a spot size of 5.8±1.0 nm and a minimum two-sample deviation of the beam position of 1.5 nm in the focal plane. The deterministic source, even when used in combination with an imperfect detector, gives rise to a fivefold increase in the signal-to-noise ratio as compared with conventional Poissonian sources. Gating of the detector signal by the extraction event suppresses dark counts by 6 orders of magnitude. We implement a Bayes experimental design approach to microscopy in order to maximize the gain in spatial information. We demonstrate this method by determining the position of a 1 μm circular hole structure to a precision of 2.7 nm using only 579 probe particles.
Using a segmented ion trap with mK laser-cooled ions we have realised a novel single ion source which can deterministically deliver a wide range of ion species, isotopes or ionic molecules [Schnitzler et al. Phys. Rev. Lett. 2009, 102, 070501]. Experimental data is discussed in detail and compared with numerical simulations of ion trajectories. For the novel ion source we numerically investigate the influence of various extraction parameters on fluctuations in velocity and position of the beam. We present specialised ion optics and show from numerical simulations that a nm spatial resolution is achievable. The Paul trap, which is used as a single ion source, together with the presented ion optics, constitutes a promising candidate for a deterministic ion implantation method for applications in solid state quantum computing or classical nano-electronic devices.
We realize a deterministic single-photon source from one and the same calcium ion interacting with a high-finesse optical cavity. Photons are created in the cavity with efficiency 88±17%, a tenfold improvement over previous cavity-ion sources. Results of the second-order correlation function are presented, demonstrating a high suppression of two-photon events limited only by background counts. The cavity photon pulse shape is obtained, with good agreement between experiment and simulation. Moreover, theoretical analysis of the temporal evolution of the atomic populations provides relevant information about the dynamics of the process and opens the way to future investigations of a coherent atom–photon interface.
Deterministic ion implantation and color-center creation methods at the nanometer scale provide a route towards scalable quantum information processing. For this purpose, we have developed an inherently deterministic single-ion implantation method based on a linear Paul trap (LPT) as a single-ion source since the laser-cooling technique can be applied to the trap system to obtain ultralow-emittance ions and manipulate single ions one by one . Doubly charged nitrogen ions (N2+) produced in a sputter ion source is introduced into the LPT and sympathetically cooled with laser-cooled calcium ions (Ca+). Both the sputter ion source and the LPT chamber are elevated to +50kV for the 100keV-implantation of doubly charged single ions into a grounded diamond crystal.