arXiv:1512.07368 · Chinese Physics B

An optimized ion trap geometry to measure quadrupole shifts of 171 Yb + clocks

Neha Batra, B. K. Sahoo, Subhadeep De

Published Nov 1, 2016• 13 citations
arXivHTMLPDF

Abstract

We propose a new ion-trap geometry to carry out accurate measurements of the quadrupole shifts in the 171 Yb ion. This trap will minimize the quadrupole shift due to the harmonic component of the confining potential by an order of magnitude. This will be useful to reduce the uncertainties in the clock frequency measurements of the 6s 2 S 1/2 → 4f 13 6s 2 2 F 7/2 and 6s 2 S 1/2 → 5d 2 D 3/2 transitions, from which we can deduce the precise values of the quadrupole moments ( Θ s) of the 4f 13 6s 2 2 F 7/2 and 5d 2 D 3/2 states. Moreover, it may be able to affirm the validity of the measured Θ value of the 4f 13 6s 2 2 F 7/2 state, for which three independent theoretical studies defer almost by one order of magnitude from the measurement. We also calculate Θ s using the relativistic coupled-cluster (RCC) method. We use these Θ values to estimate the quadrupole shift that can be measured in our proposed ion trap experiment.

DOI
10.1088/1674-1056/25/11/113703

Related papers

A TRAPPED 171 Yb + ION OPTICAL FREQUENCY STANDARD BASED ON THE S 1/2 - F 7/2 TRANSITION

P. GILL, Stephen A. Webster, G. HUANG +7 more

The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Design of a Low Uncertainty Ion Trap for a Transportable Ion Optical Clock

P. Dubé

We are designing an rf trap for a transportable optical clock based on the strontium ion. This new design aims to minimize systematic shifts, especially the blackbody radiation shift, and to optimize the geometry to reduce the electric quadrupole shift and provide efficient laser cooling along the three principal axes of ion motion. This new trap will be part of a transportable optical clock that will have an uncertainty expected to reach the low 10-18level.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•0 citations

High-Resolution Spectroscopy of $^{173}$Yb$^{+}$ Ions

J. Jiang, A. V. Viatkina, Saaswath JK +7 more

Compared to other stable isotopes of $\rm{Yb}^+$, $^{173}\rm{Yb}^+$ has a richer hyperfine structure, which leads to more favorable clock transitions, spectroscopic techniques for probing new physics, and more sophisticated quantum computing architectures. However, to date, its electronic spectrum remains poorly characterized. Here, we report on efficient laser cooling, state preparation, and detection of a single trapped $^{173}\rm{Yb}^+$ ion. The previously unobserved $^2\!S_{1/2} \rightarrow {}^2\!D_{3/2}$ electric quadrupole transition at 436 nm is coherently excited, and the isotope shift between $^{171}\rm{Yb}^+$ and $^{173}\rm{Yb}^+$ on this transition is determined with an uncertainty of 1.4 Hz. Using microwave spectroscopy, we resolve the hyperfine structure (HFS) of the ${}^2\!D_{3/2}$ state with a relative uncertainty below $10^{-8}$. From the HFS measurement data, we infer for ${}^{173}$Yb a nuclear magnetic octupole moment $Ω= -0.062(8)\,({\rm b} \times μ_N)$ with uncertainty reduced by more than 2 orders of magnitude compared to previous studies. The data also allow us to determine hyperfine anomalies for the ${}^2\!S_{1/2}$ and ${}^2\!D_{3/2}$ states.

physics.atom-phCross-listedarXiv:2601.09585•Physical Review Letters•Jan 15, 2026•3 citations

Evaluation of the electric quadrupole shift in the ytterbium single-ion optical clock

Chao-Wei Wang, Shao-Yang Dai, Ya-Ni Zuo +4 more

Abstract Optical clocks with ultralow uncertainty are strong candidates for the next redefinition of the SI second. The 171 Yb + single-ion clock is particularly attractive owing to its two clock transitions (E2 and E3) and its potential for low uncertainty. A major contribution to the uncertainty budget arises from the electric-quadrupole shift, caused by the interaction between the atomic quadrupole moment and the electric-field gradient at the trap center and strongly dependent on the orientation of the quantization axis. To evaluate this shift, a simplified orthogonal magnetic-field method was employed: three mutually orthogonal magnetic-field directions are generated together with an auxiliary non-orthogonal field. With a dual-condition locking scheme, we measure the E2 transition frequency differences between magnetic-field configurations, infer the electric-field gradient, and apply corrections for the associated quadratic Zeeman shifts. The uncertainty due to magnetic-field misalignment is quantified using a calibrated current-to-field model. The resulting electric-quadrupole shift correction for the 2 S 1/2 → 2 F 7/2 (E3) transition is 3.24 mHz, corresponding to a fractional uncertainty of 1.1×10 −18 in the absolute frequency measurement.

Chinese Physics B•Apr 17, 2026•0 citations

The mercury-ion optical clock: towards a measurement of the quadrupole shift

Windell H. Oskay, A. Bartels, Scott A. Diddams +6 more

An optical clock based upon a single mercury ion in a radio-frequency trap has the potential for both high stability and high accuracy. The systematic uncertainty of this frequency standard is limited by contributions due to two types of external fields. The clock has previously been operated with a magnetic bias field that destabilizes dark states that limit the rates of laser cooling and state detection. This bias field has previously resulted in a substantial second-order Zeeman shift. We now destabilize the dark states with a polarization-scrambling technique that allows us to operate with only a minimal magnetic field. The second uncertainty that we address here is the magnitude of the quadrupole shift due to the interaction of stray electric-field gradients with the quadrupole moment of the ion. We describe the steps that we are taking to evaluate this shift in the near future. 1

European Frequency and Time Forum•Jan 1, 2004•2 citations

High-Accuracy Optical Clock Based on the Octupole Transition in Yb+171

Nils Huntemann, Maksim V. Okhapkin, B. Lipphardt +3 more

We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.

arXiv:1111.2446•Physical Review Letters•Feb 29, 2012•252 citations
We propose a new ion-trap geometry to carry out accurate measurements of the quadrupole shifts in the 171 Yb ion. This trap will minimize the quadrupole shift due to the harmonic component of the confining potential by an order of magnitude. This will be useful to reduce the uncertainties in the clock frequency measurements of the 6s 2 S 1/2 → 4f 13 6s 2 2 F 7/2 and 6s 2 S 1/2 → 5d 2 D 3/2 transitions, from which we can deduce the precise values of the quadrupole moments ( Θ s) of the 4f 13 6s 2 2 F 7/2 and 5d 2 D 3/2 states. Moreover, it may be able to affirm the validity of the measured Θ value of the 4f 13 6s 2 2 F 7/2 state, for which three independent theoretical studies defer almost by one order of magnitude from the measurement. We also calculate Θ s using the relativistic coupled-cluster (RCC) method. We use these Θ values to estimate the quadrupole shift that can be measured in our proposed ion trap experiment.
The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.
High-Resolution Spectroscopy of 173^{173}173Yb+^{+}+ Ions
Compared to other stable isotopes of Yb+\rm{Yb}^+Yb+, 173Yb+^{173}\rm{Yb}^+173Yb+ has a richer hyperfine structure, which leads to more favorable clock transitions, spectroscopic techniques for probing new physics, and more sophisticated quantum computing architectures. However, to date, its electronic spectrum remains poorly characterized. Here, we report on efficient laser cooling, state preparation, and detection of a single trapped 173Yb+^{173}\rm{Yb}^+173Yb+ ion. The previously unobserved 2 ⁣S1/2→2 ⁣D3/2^2\!S_{1/2} \rightarrow {}^2\!D_{3/2}2S1/2​→2D3/2​ electric quadrupole transition at 436 nm is coherently excited, and the isotope shift between 171Yb+^{171}\rm{Yb}^+171Yb+ and 173Yb+^{173}\rm{Yb}^+173Yb+ on this transition is determined with an uncertainty of 1.4 Hz. Using microwave spectroscopy, we resolve the hyperfine structure (HFS) of the 2 ⁣D3/2{}^2\!D_{3/2}2D3/2​ state with a relative uncertainty below 10−810^{-8}10−8. From the HFS measurement data, we infer for 173{}^{173}173Yb a nuclear magnetic octupole moment Ω=−0.062(8) (b×μN)Ω= -0.062(8)\,({\rm b} \times μ_N)Ω=−0.062(8)(b×μN​) with uncertainty reduced by more than 2 orders of magnitude compared to previous studies. The data also allow us to determine hyperfine anomalies for the 2 ⁣S1/2{}^2\!S_{1/2}2S1/2​ and 2 ⁣D3/2{}^2\!D_{3/2}2D3/2​ states.
Abstract Optical clocks with ultralow uncertainty are strong candidates for the next redefinition of the SI second. The 171 Yb + single-ion clock is particularly attractive owing to its two clock transitions (E2 and E3) and its potential for low uncertainty. A major contribution to the uncertainty budget arises from the electric-quadrupole shift, caused by the interaction between the atomic quadrupole moment and the electric-field gradient at the trap center and strongly dependent on the orientation of the quantization axis. To evaluate this shift, a simplified orthogonal magnetic-field method was employed: three mutually orthogonal magnetic-field directions are generated together with an auxiliary non-orthogonal field. With a dual-condition locking scheme, we measure the E2 transition frequency differences between magnetic-field configurations, infer the electric-field gradient, and apply corrections for the associated quadratic Zeeman shifts. The uncertainty due to magnetic-field misalignment is quantified using a calibrated current-to-field model. The resulting electric-quadrupole shift correction for the 2 S 1/2 → 2 F 7/2 (E3) transition is 3.24 mHz, corresponding to a fractional uncertainty of 1.1×10 −18 in the absolute frequency measurement.
An optical clock based upon a single mercury ion in a radio-frequency trap has the potential for both high stability and high accuracy. The systematic uncertainty of this frequency standard is limited by contributions due to two types of external fields. The clock has previously been operated with a magnetic bias field that destabilizes dark states that limit the rates of laser cooling and state detection. This bias field has previously resulted in a substantial second-order Zeeman shift. We now destabilize the dark states with a polarization-scrambling technique that allows us to operate with only a minimal magnetic field. The second uncertainty that we address here is the magnitude of the quadrupole shift due to the interaction of stray electric-field gradients with the quadrupole moment of the ion. We describe the steps that we are taking to evaluate this shift in the near future. 1
We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.