Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1512.03652 · Physical Review A

Direct state reconstruction with coupling-deformed pointer observables

Xuanmin Zhu, Yu-Xiang Zhang, Shengjun Wu

Published Jun 2, 2016• 18 citations
arXivHTMLPDF

Abstract

Direct state tomography (DST) using weak measurements has received wide attention. Based on the concept of coupling-deformed pointer observables presented by Zhang et al. [Y.-X. Zhang, S. Wu, and Z.-B. Chen, Phys. Rev. A 93, 032128 (2016)], a modified direct state tomography (MDST) is proposed, examined, and compared with other typical state tomography schemes. MDST has exact validity for measurements of any strength. We identify the strength needed to attain the highest efficiency level of MDST by using statistical theory. MDST is much more efficient than DST in the sense that far fewer samples are needed to reach DST's level of reconstruction accuracy. Moreover, MDST has no inherent bias when compared to DST.

DOI
10.1103/physreva.93.062304

Related papers

Unbiased state reconstruction using modified weak measurement

Xuanmin Zhu, Yu-Xiang Zhang, Shengjun Wu

Based on the modified weak measurement scheme in [Y-X Zhang, S Wu and Z-B Chen, arXiv: 1504.07130], a modified direct state measurement (MDSM) is proposed without inherent bias. Compared with the existing direct state measurement (DSM), MDSM is more efficient and valid for any coupling strength. Through accurate Monte Carlo simulations, we get the optimal coupling strength to attain high efficiency. For the same reconstruction precision, we compare the number of copies needed in MDSM and the one in conventional quantum state tomography (QST) by simulations. We find MDSM is less efficient than conventional QST. However, MDSM is much easier to be realized in actual experiments, and might be more useful.

•Dec 11, 2015•1 citation

State estimation: A comparison between direct state measurement and tomography

Lorenzo Maccone, Cosimo C. Rusconi

We compare direct state measurement (DST or weak state tomography) to conventional state reconstruction (tomography) through accurate Monte-Carlo simulations. We show that DST is surprisingly robust to its inherent bias. We propose a method to estimate such bias (which introduces an unavoidable error in the reconstruction) from the experimental data. As expected we find that DST is much less precise than tomography. We consider both finite and infinite-dimensional states of the DST pointer, showing that they provide comparable reconstructions.

arXiv:1310.6206•Physical Review A•Feb 24, 2014•44 citations

Hybrid direct state tomography by weak value

Xuanmin Zhu, Qun Wei, Lixia Liu +1 more

Compared with the conventional quantum state tomography (QST), the direct state tomography (DST) using weak value is easily manipulated in experiments. However, the efficiency of the DST is lower than that of the conventional QST, especially for high-dimensional systems. For a pure state, the DST is revised to improve the efficiency. In the revised DST, the real or imaginary parts of the weak values can be obtained by measuring only one system observable. We constructed a hybrid DST by combining the original DST and the revised DST. By using the appropriate measurement strength, the efficiency of the hybrid DST is significantly larger than that of the conventional QST, especially for high-dimensional systems. The state reconstruction strategy investigated in this paper may be useful in actual experiments.

arXiv:1909.02461•Sep 5, 2019•2 citations

Error estimation in the direct state tomography

Isabel Sainz, A. B. Klimov

We show that reformulating the Direct State Tomography (DST) protocol in terms of projections into a set of non-orthogonal bases one can perform an accuracy analysis of DST in a similar way as in the standard projection-based reconstruction schemes, i.e. , in terms of the Hilbert-Schmidt distance between estimated and true states. This allows us to determine the estimation error for any measurement strength, including the weak measurement case, and to obtain an explicit analytic form for the average minimum square errors.

arXiv:1607.07764•Europhysics Letters (EPL)•Oct 1, 2016•4 citations

Direct Reconstruction of the Quantum Density Matrix by Strong Measurements

Luca Calderaro, Giulio Foletto, Daniele Dequal +2 more

New techniques based on weak measurements have recently been introduced to the field of quantum state reconstruction. Some of them allow the direct measurement of each matrix element of an unknown density operator and need only O(d) different operations, compared to d^{2} linearly independent projectors in the case of standard quantum state tomography, for the reconstruction of an arbitrary mixed state. However, due to the weakness of these couplings, these protocols are approximated and prone to large statistical errors. We propose a method which is similar to the weak measurement protocols but works regardless of the coupling strength: our protocol is not approximated and thus improves the accuracy and precision of the results with respect to weak measurement schemes. We experimentally apply it to the polarization state of single photons and compare the results to those of preexisting methods for different values of the coupling strength. Our results show that our method outperforms previous proposals in terms of accuracy and statistical errors.

arXiv:1803.10703•Physical Review Letters•Dec 7, 2018•57 citations

Direct polarisation-state reconstruction with a temporal pointer: accessible states, resolution and optimal coupling

Shane P. Gervais, Lambert Giner

Weak measurements are used to amplify small signals, to address foundational questions, and to characterise quantum states without tomography. In direct state reconstruction each amplitude of the state vector is proportional to a single complex weak value, which for a temporal pointer is read from the mean arrival time and the mean frequency of the postselected pulse. Such an experiment requires three quantities to be fixed, the coupling, the angular resolution demanded of the reconstruction, and the set of states over which the method remains usable, and these are commonly set by the available apparatus rather than derived. We derive all three for a Gaussian temporal pointer and an arbitrary postselection state. The states that cannot be reconstructed form a spherical cap centred on the state orthogonal to the postselection, whose geodesic half-angle follows from the largest of three independent thresholds and involves no adjustable parameter. Two states are distinguishable only if they differ by more than a minimal step fixed by the coupling, by the number of incident photons and by the sensitivity of the weak value along the path followed. For an inversion at first order in the coupling the systematic and statistical errors are opposed and fix an optimal coupling that varies as the inverse sixth root of the number of incident photons, whereas an exact inversion at finite coupling removes the systematic error, the remaining bound being one on the two-centroid readout rather than on the inversion, since below an amplitude equal to a quarter of the coupling two states give the same pair of centroids while their profiles differ. These results allow a direct reconstruction experiment to be dimensioned before the apparatus is assembled.

quant-pharXiv:2610.16871•Oct 13, 2026•0 citations
Direct state tomography (DST) using weak measurements has received wide attention. Based on the concept of coupling-deformed pointer observables presented by Zhang et al. [Y.-X. Zhang, S. Wu, and Z.-B. Chen, Phys. Rev. A 93, 032128 (2016)], a modified direct state tomography (MDST) is proposed, examined, and compared with other typical state tomography schemes. MDST has exact validity for measurements of any strength. We identify the strength needed to attain the highest efficiency level of MDST by using statistical theory. MDST is much more efficient than DST in the sense that far fewer samples are needed to reach DST's level of reconstruction accuracy. Moreover, MDST has no inherent bias when compared to DST.
Based on the modified weak measurement scheme in [Y-X Zhang, S Wu and Z-B Chen, arXiv: 1504.07130], a modified direct state measurement (MDSM) is proposed without inherent bias. Compared with the existing direct state measurement (DSM), MDSM is more efficient and valid for any coupling strength. Through accurate Monte Carlo simulations, we get the optimal coupling strength to attain high efficiency. For the same reconstruction precision, we compare the number of copies needed in MDSM and the one in conventional quantum state tomography (QST) by simulations. We find MDSM is less efficient than conventional QST. However, MDSM is much easier to be realized in actual experiments, and might be more useful.
We compare direct state measurement (DST or weak state tomography) to conventional state reconstruction (tomography) through accurate Monte-Carlo simulations. We show that DST is surprisingly robust to its inherent bias. We propose a method to estimate such bias (which introduces an unavoidable error in the reconstruction) from the experimental data. As expected we find that DST is much less precise than tomography. We consider both finite and infinite-dimensional states of the DST pointer, showing that they provide comparable reconstructions.
Compared with the conventional quantum state tomography (QST), the direct state tomography (DST) using weak value is easily manipulated in experiments. However, the efficiency of the DST is lower than that of the conventional QST, especially for high-dimensional systems. For a pure state, the DST is revised to improve the efficiency. In the revised DST, the real or imaginary parts of the weak values can be obtained by measuring only one system observable. We constructed a hybrid DST by combining the original DST and the revised DST. By using the appropriate measurement strength, the efficiency of the hybrid DST is significantly larger than that of the conventional QST, especially for high-dimensional systems. The state reconstruction strategy investigated in this paper may be useful in actual experiments.
We show that reformulating the Direct State Tomography (DST) protocol in terms of projections into a set of non-orthogonal bases one can perform an accuracy analysis of DST in a similar way as in the standard projection-based reconstruction schemes, i.e. , in terms of the Hilbert-Schmidt distance between estimated and true states. This allows us to determine the estimation error for any measurement strength, including the weak measurement case, and to obtain an explicit analytic form for the average minimum square errors.
New techniques based on weak measurements have recently been introduced to the field of quantum state reconstruction. Some of them allow the direct measurement of each matrix element of an unknown density operator and need only O(d) different operations, compared to d^{2} linearly independent projectors in the case of standard quantum state tomography, for the reconstruction of an arbitrary mixed state. However, due to the weakness of these couplings, these protocols are approximated and prone to large statistical errors. We propose a method which is similar to the weak measurement protocols but works regardless of the coupling strength: our protocol is not approximated and thus improves the accuracy and precision of the results with respect to weak measurement schemes. We experimentally apply it to the polarization state of single photons and compare the results to those of preexisting methods for different values of the coupling strength. Our results show that our method outperforms previous proposals in terms of accuracy and statistical errors.
Weak measurements are used to amplify small signals, to address foundational questions, and to characterise quantum states without tomography. In direct state reconstruction each amplitude of the state vector is proportional to a single complex weak value, which for a temporal pointer is read from the mean arrival time and the mean frequency of the postselected pulse. Such an experiment requires three quantities to be fixed, the coupling, the angular resolution demanded of the reconstruction, and the set of states over which the method remains usable, and these are commonly set by the available apparatus rather than derived. We derive all three for a Gaussian temporal pointer and an arbitrary postselection state. The states that cannot be reconstructed form a spherical cap centred on the state orthogonal to the postselection, whose geodesic half-angle follows from the largest of three independent thresholds and involves no adjustable parameter. Two states are distinguishable only if they differ by more than a minimal step fixed by the coupling, by the number of incident photons and by the sensitivity of the weak value along the path followed. For an inversion at first order in the coupling the systematic and statistical errors are opposed and fix an optimal coupling that varies as the inverse sixth root of the number of incident photons, whereas an exact inversion at finite coupling removes the systematic error, the remaining bound being one on the two-centroid readout rather than on the inversion, since below an amplitude equal to a quarter of the coupling two states give the same pair of centroids while their profiles differ. These results allow a direct reconstruction experiment to be dimensioned before the apparatus is assembled.