Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1508.05129 · Physical Review A

Probing beyond the laser coherence time in optical clock comparisons

David B. Hume, David R. Leibrandt

Published Mar 30, 2016• 43 citations
arXivHTMLPDF

Abstract

We develop differential measurement protocols that circumvent the laser noise limit in the stability of optical clock comparisons by synchronous probing of two clocks using phase-locked local oscillators. This allows for probe times longer than the laser coherence time, avoids the Dick effect, and supports Heisenberg-limited measurement precision. We present protocols for such frequency comparisons and develop numerical simulations of the protocols with realistic noise sources. These methods provide a route to reduce frequency ratio measurement durations by more than an order of magnitude.

DOI
10.1103/physreva.93.032138

Related papers

Leveraging correlated laser noise to improve optical frequency comparisons

Ethan Clements, M. Bohman, May E. Kim +14 more

Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.

Optical and Quantum Sensing and Precision Metrology II•Mar 9, 2022•0 citations

Dynamical decoupling of laser phase noise in compound atomic clocks

Sören Dörscher, Ali Al-Masoudi, Marcin Bober +4 more

Abstract The frequency stability of many optical atomic clocks is limited by the coherence of their local oscillator. Here, we present a measurement protocol that overcomes the laser coherence limit. It relies on engineered dynamical decoupling of laser phase noise and near-synchronous interrogation of two clocks. One clock coarsely tracks the laser phase using dynamical decoupling; the other refines this estimate using a high-resolution phase measurement. While the former needs to have a high signal-to-noise ratio, the latter clock may operate with any number of particles. The protocol effectively enables minute-long Ramsey interrogation for coherence times of few seconds as provided by the current best ultrastable laser systems. We demonstrate implementation of the protocol in a realistic proof-of-principle experiment, where we interrogate for 0.5 s at a laser coherence time of 77 ms. Here, a single lattice clock is used to emulate synchronous interrogation of two separate clocks in the presence of artificial laser frequency noise. We discuss the frequency instability of a single-ion clock that would result from using the protocol for stabilisation, under these conditions and for minute-long interrogation, and find expected instabilities of σy(τ) = 8 × 10−16(τ/s)−1/2 and σy(τ) = 5 × 10−17(τ/s)−1/2, respectively.

arXiv:1911.13146•Communications Physics•Oct 20, 2020•28 citations

Lifetime-Limited Interrogation of Two Independent Al + 27 Clocks Using Correlation Spectroscopy

Ethan Clements, May E. Kim, Kaifeng Cui +7 more

Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+}. By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of 1.12×10^{15} Hz. The observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s ^{3}P_{0} state lifetime and represents a measurement instability of (1.8±0.5)×10^{-16}/sqrt[τ/s] for averaging periods longer than the probe duration when dead time is negligible.

arXiv:2007.02193•Physical Review Letters•Dec 9, 2020•41 citations

Optical coherence between atomic species at the second scale: improved\n clock comparisons via differential spectroscopy

May E. Kim, William F. McGrew, Nicholas V. Nardelli +9 more

Comparisons of high-accuracy optical atomic clocks \\cite{Ludlow2015} are essential for precision tests of fundamental physics \\cite{Safronova2018}, relativistic geodesy \\cite{McGrew2018, Grotti2018, Delva2019}, and the anticipated redefinition of the SI second \\cite{Riehle2018}. The scientific reach of these applications is restricted by the statistical precision of interspecies comparison measurements. The instability of individual clocks is limited by the finite coherence time of the optical local oscillator (OLO), which bounds the maximum atomic interrogation time. In this letter, we experimentally demonstrate differential spectroscopy \\cite{Hume2016}, a comparison protocol that enables interrogating beyond the OLO coherence time. By phase-coherently linking a zero-dead-time (ZDT) \\cite{Schioppo2017} Yb optical lattice clock with an Al$^+$ single-ion clock via an optical frequency comb and performing synchronised Ramsey spectroscopy, we show an improvement in comparison instability relative to our previous result \\cite{network2020frequency} of nearly an order of magnitude. To our knowledge, this result represents the most stable interspecies clock comparison to date.

arXiv:2109.09540•Sep 20, 2021•7 citations

Demonstration of chronometric leveling using transportable optical clocks beyond laser coherence limit

Yi Yuan, Kaifeng Cui, Daoxin Liu +6 more

An optical clock network requires the establishment of an optical frequency transmission link between multiple optical clocks, utilizing narrow-linewidth lasers. Despite achieving link noise levels of ${10}^{\ensuremath{-}20}$, the final accuracy is limited by the phase noise of the clock laser. Correlation spectroscopy has been developed to transmit frequency information between two optical clocks directly, enabling optical clock comparison beyond the phase noise limit of clock lasers, and significantly enhancing the measurement accuracy or shortening the measurement time. In this article, two compact transportable ${}^{40}\mathrm{Ca}{}^{+}$ clocks are employed to accomplish a correlation spectroscopy comparison, demonstrating a 10-cm level measurement accuracy of chronometric leveling using a mediocre clock laser with linewidth of 200 Hz. The relative frequency instability reaches $6.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}/\sqrt{\ensuremath{\tau}/s}$, which is about 20 times better than the result with Rabi spectroscopy using the same clock laser. This method circumvents the harsh requirements on the performance of the clock laser, so that an ordinary stable laser can also be employed in the construction of an optical clock network, which is essential for field applications, especially for chronometric leveling.

arXiv:2310.08835•Physical Review Applied•Apr 29, 2024•12 citations

Optimization of Feedback-Loop Parameters in Thulium Optical Clocks at Synchronous Comparison

Dmitry O. Tregubov, Daniil I. Provorchenko, D. Mishin +2 more

Abstract Synchronous comparison of optical clocks using phase-coherent clock lasers makes it possible to determine the difference (ratio) of clock transition frequencies, which is not limited by the total noise of lasers in use. A detailed simulation of the comparison of two thulium optical clocks is performed using synchronous interrogation of atoms by the radiation of a common clock laser. Some critical parameters have been determined, specifically: the residual noncorrelated frequency and amplitude noises of test pulses and reading noises, which may deteriorate the comparison stability. At the same time, it is demonstrated that this way is insensitive to fluctuations in the number of atoms, calibration of feedback-loop parameters, individual ejections in measurement cycles, and fluctuations of laboratory magnetic field.

Journal of Experimental and Theoretical Physics•Aug 1, 2023•2 citations
We develop differential measurement protocols that circumvent the laser noise limit in the stability of optical clock comparisons by synchronous probing of two clocks using phase-locked local oscillators. This allows for probe times longer than the laser coherence time, avoids the Dick effect, and supports Heisenberg-limited measurement precision. We present protocols for such frequency comparisons and develop numerical simulations of the protocols with realistic noise sources. These methods provide a route to reduce frequency ratio measurement durations by more than an order of magnitude.
Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.
Abstract The frequency stability of many optical atomic clocks is limited by the coherence of their local oscillator. Here, we present a measurement protocol that overcomes the laser coherence limit. It relies on engineered dynamical decoupling of laser phase noise and near-synchronous interrogation of two clocks. One clock coarsely tracks the laser phase using dynamical decoupling; the other refines this estimate using a high-resolution phase measurement. While the former needs to have a high signal-to-noise ratio, the latter clock may operate with any number of particles. The protocol effectively enables minute-long Ramsey interrogation for coherence times of few seconds as provided by the current best ultrastable laser systems. We demonstrate implementation of the protocol in a realistic proof-of-principle experiment, where we interrogate for 0.5 s at a laser coherence time of 77 ms. Here, a single lattice clock is used to emulate synchronous interrogation of two separate clocks in the presence of artificial laser frequency noise. We discuss the frequency instability of a single-ion clock that would result from using the protocol for stabilisation, under these conditions and for minute-long interrogation, and find expected instabilities of σy(τ) = 8 × 10−16(τ/s)−1/2 and σy(τ) = 5 × 10−17(τ/s)−1/2, respectively.
Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+}. By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of 1.12×10^{15} Hz. The observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s ^{3}P_{0} state lifetime and represents a measurement instability of (1.8±0.5)×10^{-16}/sqrt[τ/s] for averaging periods longer than the probe duration when dead time is negligible.
Comparisons of high-accuracy optical atomic clocks \\cite{Ludlow2015} are essential for precision tests of fundamental physics \\cite{Safronova2018}, relativistic geodesy \\cite{McGrew2018, Grotti2018, Delva2019}, and the anticipated redefinition of the SI second \\cite{Riehle2018}. The scientific reach of these applications is restricted by the statistical precision of interspecies comparison measurements. The instability of individual clocks is limited by the finite coherence time of the optical local oscillator (OLO), which bounds the maximum atomic interrogation time. In this letter, we experimentally demonstrate differential spectroscopy \\cite{Hume2016}, a comparison protocol that enables interrogating beyond the OLO coherence time. By phase-coherently linking a zero-dead-time (ZDT) \\cite{Schioppo2017} Yb optical lattice clock with an Al+^++ single-ion clock via an optical frequency comb and performing synchronised Ramsey spectroscopy, we show an improvement in comparison instability relative to our previous result \\cite{network2020frequency} of nearly an order of magnitude. To our knowledge, this result represents the most stable interspecies clock comparison to date.
An optical clock network requires the establishment of an optical frequency transmission link between multiple optical clocks, utilizing narrow-linewidth lasers. Despite achieving link noise levels of ${10}^{\ensuremath{-}20}$, the final accuracy is limited by the phase noise of the clock laser. Correlation spectroscopy has been developed to transmit frequency information between two optical clocks directly, enabling optical clock comparison beyond the phase noise limit of clock lasers, and significantly enhancing the measurement accuracy or shortening the measurement time. In this article, two compact transportable 40Ca+{}^{40}\mathrm{Ca}{}^{+}40Ca+ clocks are employed to accomplish a correlation spectroscopy comparison, demonstrating a 10-cm level measurement accuracy of chronometric leveling using a mediocre clock laser with linewidth of 200 Hz. The relative frequency instability reaches $6.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}/\sqrt{\ensuremath{\tau}/s}$, which is about 20 times better than the result with Rabi spectroscopy using the same clock laser. This method circumvents the harsh requirements on the performance of the clock laser, so that an ordinary stable laser can also be employed in the construction of an optical clock network, which is essential for field applications, especially for chronometric leveling.
Abstract Synchronous comparison of optical clocks using phase-coherent clock lasers makes it possible to determine the difference (ratio) of clock transition frequencies, which is not limited by the total noise of lasers in use. A detailed simulation of the comparison of two thulium optical clocks is performed using synchronous interrogation of atoms by the radiation of a common clock laser. Some critical parameters have been determined, specifically: the residual noncorrelated frequency and amplitude noises of test pulses and reading noises, which may deteriorate the comparison stability. At the same time, it is demonstrated that this way is insensitive to fluctuations in the number of atoms, calibration of feedback-loop parameters, individual ejections in measurement cycles, and fluctuations of laboratory magnetic field.