Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2109.09540

Optical coherence between atomic species at the second scale: improved\n clock comparisons via differential spectroscopy

May E. Kim, William F. McGrew, Nicholas V. Nardelli, Ethan Clements, Youssef S. Hassan (2897462), Xiaogang Zhang (1282050), Jose L. Valencia (14407497), Holly Leopardi, David B. Hume, Tara M. Fortier, A. D. Ludlow, David R. Leibrandt

Published Sep 20, 2021• 7 citations
arXivHTMLPDF

Abstract

Comparisons of high-accuracy optical atomic clocks \\cite{Ludlow2015} are essential for precision tests of fundamental physics \\cite{Safronova2018}, relativistic geodesy \\cite{McGrew2018, Grotti2018, Delva2019}, and the anticipated redefinition of the SI second \\cite{Riehle2018}. The scientific reach of these applications is restricted by the statistical precision of interspecies comparison measurements. The instability of individual clocks is limited by the finite coherence time of the optical local oscillator (OLO), which bounds the maximum atomic interrogation time. In this letter, we experimentally demonstrate differential spectroscopy \\cite{Hume2016}, a comparison protocol that enables interrogating beyond the OLO coherence time. By phase-coherently linking a zero-dead-time (ZDT) \\cite{Schioppo2017} Yb optical lattice clock with an Al$^+$ single-ion clock via an optical frequency comb and performing synchronised Ramsey spectroscopy, we show an improvement in comparison instability relative to our previous result \\cite{network2020frequency} of nearly an order of magnitude. To our knowledge, this result represents the most stable interspecies clock comparison to date.

DOI
10.48550/arxiv.2109.09540

Related papers

Leveraging correlated laser noise to improve optical frequency comparisons

Ethan Clements, M. Bohman, May E. Kim +14 more

Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.

Optical and Quantum Sensing and Precision Metrology II•Mar 9, 2022•0 citations

Exploiting phase coherence for improved resolution in optical atomic frequency ratios

Tara M. Fortier

Optical atomic clocks that operate at frequencies up to 100,000 times higher than their microwave counterparts permit better resolutions and accuracies, while also providing more leeway in environmental control for out of lab applications. Many of the precision applications of these clocks, including relativistic geodesy and tests of fundamental physics rely on the intercomparison of at least two optical clocks. Relative comparisons that include single ion clocks, however, can require close to one month of continuous averaging to achieve measurement instabilities near 1 part in 1018. The long averaging times result from limits imposed on the quantum project noise as a result of signal detection from a single ion, as well as atom probe time limitations due to laser-atom decoherence. In this talk I will describe how the phase coherent properties of an optical frequency comb can be used to enable correlated and synchronous measurement of atomic clocks as a means to improve their relative measurement instability by close to a factor of 10, and nearly 100 times speed up in averaging time over conventional measurement techniques.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

A Multiplexed Strontium Optical Lattice Clock

Jonathan Dolde

Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.

•May 1, 2026•0 citations

176 Lu + clock comparison at the 10 −18 level via correlation spectroscopy

Zhiqiang Zhang, K. J. Arnold, R. Kaewuam +1 more

The extreme precision of optical atomic clocks has led to an anticipated redefinition of the second by the International System of Units. Furthermore, accuracies pushing the boundary of 1 part in 10 18 and beyond will enable new applications, such as in geodesy and tests of fundamental physics. The 1 S 0 to 3 D 1 optical transition in 176 Lu + has exceptionally low sensitivity to external perturbations, making it suitable for practical clock implementations with inaccuracy at or below 10 −18 . Here, we perform high-accuracy comparisons between two 176 Lu + references using correlation spectroscopy. A comparison at different magnetic fields is used to obtain a quadratic Zeeman coefficient of −4.89264(88) Hz/mT for the reference frequency. With a subsequent comparison at low field, we demonstrate agreement at the low 10 −18 level, statistically limited by the averaging time of 42 hours. The evaluated uncertainty in the frequency difference is 9 × 10 −19 and the lowest reported in comparing independent optical references.

arXiv:2212.04652•Science Advances•May 3, 2023•70 citations

Reducing the Instability of an Optical Lattice Clock Using Multiple Atomic Ensembles

Xin Zheng, Jonathan Dolde, Shimon Kolkowitz

The stability of an optical atomic clock is a critical figure of merit for almost all clock applications. To this end, much optical atomic clock research has focused on reducing clock instability by increasing the atom number, lengthening the coherent interrogation times, and introducing entanglement to push beyond the standard quantum limit. In this work, we experimentally demonstrate an alternative approach to reducing clock instability using a phase estimation approach based on individually controlled atomic ensembles in a strontium (Sr) optical lattice clock. We first demonstrate joint Ramsey interrogation of two spatially resolved atom ensembles that are out of phase with respect to each other, which we call “quadrature Ramsey spectroscopy,” resulting in a factor of 1.36(5) reduction in absolute clock instability as measured with interleaved self-comparisons. We then leverage the rich hyperfine structure of Sr87 to realize independent coherent control over multiple ensembles with only global laser addressing. Finally, we utilize this independent control over four atom ensembles to implement a form of phase estimation, achieving a factor of greater than 3 enhancement in coherent interrogation time and a factor of 2.08(6) reduction in instability over an otherwise identical single-ensemble clock with the same local oscillator and the same number of atoms. We expect that multiensemble protocols similar to those demonstrated here will result in reduction in the instability of any optical lattice clock with an interrogation time limited by the local oscillator. Published by the American Physical Society 2024

arXiv:2305.12315•Physical Review X•Jan 23, 2024•19 citations

Spectroscopy schemes for improved optical clock stability

Filip Butuc-Mayer

Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.

•Jan 1, 2026•0 citations
Comparisons of high-accuracy optical atomic clocks \cite{Ludlow2015} are essential for precision tests of fundamental physics \cite{Safronova2018}, relativistic geodesy \cite{McGrew2018, Grotti2018, Delva2019}, and the anticipated redefinition of the SI second \cite{Riehle2018}. The scientific reach of these applications is restricted by the statistical precision of interspecies comparison measurements. The instability of individual clocks is limited by the finite coherence time of the optical local oscillator (OLO), which bounds the maximum atomic interrogation time. In this letter, we experimentally demonstrate differential spectroscopy \cite{Hume2016}, a comparison protocol that enables interrogating beyond the OLO coherence time. By phase-coherently linking a zero-dead-time (ZDT) \cite{Schioppo2017} Yb optical lattice clock with an Al+^++ single-ion clock via an optical frequency comb and performing synchronised Ramsey spectroscopy, we show an improvement in comparison instability relative to our previous result \cite{network2020frequency} of nearly an order of magnitude. To our knowledge, this result represents the most stable interspecies clock comparison to date.
Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.
Optical atomic clocks that operate at frequencies up to 100,000 times higher than their microwave counterparts permit better resolutions and accuracies, while also providing more leeway in environmental control for out of lab applications. Many of the precision applications of these clocks, including relativistic geodesy and tests of fundamental physics rely on the intercomparison of at least two optical clocks. Relative comparisons that include single ion clocks, however, can require close to one month of continuous averaging to achieve measurement instabilities near 1 part in 1018. The long averaging times result from limits imposed on the quantum project noise as a result of signal detection from a single ion, as well as atom probe time limitations due to laser-atom decoherence. In this talk I will describe how the phase coherent properties of an optical frequency comb can be used to enable correlated and synchronous measurement of atomic clocks as a means to improve their relative measurement instability by close to a factor of 10, and nearly 100 times speed up in averaging time over conventional measurement techniques.
Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.
The extreme precision of optical atomic clocks has led to an anticipated redefinition of the second by the International System of Units. Furthermore, accuracies pushing the boundary of 1 part in 10 18 and beyond will enable new applications, such as in geodesy and tests of fundamental physics. The 1 S 0 to 3 D 1 optical transition in 176 Lu + has exceptionally low sensitivity to external perturbations, making it suitable for practical clock implementations with inaccuracy at or below 10 −18 . Here, we perform high-accuracy comparisons between two 176 Lu + references using correlation spectroscopy. A comparison at different magnetic fields is used to obtain a quadratic Zeeman coefficient of −4.89264(88) Hz/mT for the reference frequency. With a subsequent comparison at low field, we demonstrate agreement at the low 10 −18 level, statistically limited by the averaging time of 42 hours. The evaluated uncertainty in the frequency difference is 9 × 10 −19 and the lowest reported in comparing independent optical references.
The stability of an optical atomic clock is a critical figure of merit for almost all clock applications. To this end, much optical atomic clock research has focused on reducing clock instability by increasing the atom number, lengthening the coherent interrogation times, and introducing entanglement to push beyond the standard quantum limit. In this work, we experimentally demonstrate an alternative approach to reducing clock instability using a phase estimation approach based on individually controlled atomic ensembles in a strontium (Sr) optical lattice clock. We first demonstrate joint Ramsey interrogation of two spatially resolved atom ensembles that are out of phase with respect to each other, which we call “quadrature Ramsey spectroscopy,” resulting in a factor of 1.36(5) reduction in absolute clock instability as measured with interleaved self-comparisons. We then leverage the rich hyperfine structure of Sr87 to realize independent coherent control over multiple ensembles with only global laser addressing. Finally, we utilize this independent control over four atom ensembles to implement a form of phase estimation, achieving a factor of greater than 3 enhancement in coherent interrogation time and a factor of 2.08(6) reduction in instability over an otherwise identical single-ensemble clock with the same local oscillator and the same number of atoms. We expect that multiensemble protocols similar to those demonstrated here will result in reduction in the instability of any optical lattice clock with an interrogation time limited by the local oscillator. Published by the American Physical Society 2024
Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.