Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1409.7101 · Journal of the Optical Society of America B

Direct measurement of the Wigner function by photon-number-resolving detection

Niranjan Sridhar, Reihaneh Shahrokhshahi, Aaron Miller, Brice Calkins, Thomas Gerrits, Adriana E. Lita, Sae Woo Nam, Olivier Pfister

Published Sep 24, 2014• 32 citations
arXivHTMLPDF

Abstract

Photon-number-resolving (PNR) detection allows for the direct measurement of the Wigner quasi-probability distribution of an optical mode without the need for numerically processing an inverse Radon transform [Phys. Rev. Lett.76, 4344 (1996)10.1103/PhysRevLett.76.4344PRLTAO0031-9007]. In this work, we reproduced the seminal experiment of Banaszek et al. [Phys. Rev. A60, 674 (1999)10.1103/PhysRevA.60.674PLRAAN1050-2947] of quantum tomography of a pure coherent state, and of a statistical mixture thereof, and extended it to the more general case of photon fluxes with much more than one photon per detection time. This was made possible by the use of a superconducting transition-edge sensor to perform PNR detection from zero to five photons at 1064 nm, at ∼70% system efficiency and with no dead time. We detail signal acquisition and detection efficiency and discuss prospects for applying such quantum tomography to non-Gaussian states.

DOI
10.1364/josab.31.000b34

Related papers

Direct measurement of the Wigner function by photon-number-resolving detection

Niranjan Sridhar, Reihaneh Shahrokhshahi, Aaron Miller +4 more

We extended the seminal experiment of Banaszek et al. of quantum tomography by photon counting without Radon transform postprocessing to the more general case of photon fluxes with more than one photon per detection time.

Conference on Lasers and Electro-Optics•Jan 1, 2015•1 citation

Quantum state engineering and state tomography using photon-number-resolving measurements (Conference Presentation)

Rajveer Nehra, Aye Win, Miller Eaton +6 more

Quantum state engineering and state characterization is a key task in quantum information processing in both discrete and continuous variable systems in the optical domain. In particular, quantum states with non-Gaussian (i.e., non-positive) Wigner quasiprobability distribution functions are crucial to universal, fault-tolerant quantum computing with continuous variables. In this talk, we present our recent results on single-photon Fock state tomography using Photon-Number-Resolving (PNR) measurements. We generated a highly pure narrow-band single-photon Fock state by heralding cavity-enhanced spontaneous-parametric-downconversion from a PPKTP optical parametric oscillator. The Wigner function was reconstructed with photon statistics obtained using superconducting transition-edge sensors with an overall system efficiency of 58(2)%. We then discuss quantum state engineering for pure displaced single-photon Fock states, optical cat states, and approximate GKP states using coherent states and single-photon states along with linear optics and PNR measurements. We report our experimental progress for the same.

Quantum Communications and Quantum Imaging•Sep 10, 2019•0 citations

State-independent quantum state tomography by photon-number-resolving measurements

Rajveer Nehra, Aye Win, Miller Eaton +6 more

The Wigner quasiprobability distribution of a narrowband single-photon state was reconstructed by quantum state tomography using photon-number-resolving measurements with transition-edge sensors (TES) at system efficiency 58(2)%. This method makes no assumptions on the nature of the measured state, save for the limitation on photon flux imposed by the TES. Negativity of the Wigner function was observed in the raw data without any inference or correction for decoherence.

arXiv:1906.02093•Optica•Oct 9, 2019•37 citations

Characterization of quantum states and detectors

Rajveer Nehra, Miller Eaton, Kevin Valson Jacob +6 more

Characterization of quantum states and detectors is a key task in rapidly emerging optical quantum science and technology. First, we introduce and experimentally demonstrate a noise-robust quantum state characterization protocol using photon-number-resolving (PNR) measurements. Unlike conventional continuous variable state tomography methods, our method utilizes computationally efficient semi-definite programming (SDP) and can be used to accurately reconstruct the state even after loss a known loss. The protocol is demonstrated for a weak coherent state as well as a single-photon Fock state. Next, we propose a method for characterizing a photodetector by directly reconstructing the Wigner functions of the detector’s Positive-Operator-Value-Measure (POVM) elements via weak-field homodyne technique. We also report our experimental progress on characterizing a superconducting transition-edge sensor for PNR measurements.

•Aug 25, 2020•0 citations

Tomography of Optical Quantum States with Imperfect Photon-Number-Resolving Detectors

I. A. Dmitriev, I. K. Golyshev, N. A. Bogdanova +2 more

Abstract A method for quantum state estimation using nonideal photon detection devices has been developed. Using the example of squeezed coherent states, we study the influence of detector efficiency and “dead time” on the fidelity of quantum-state reconstruction for photon-number-resolving (PNR) detectors.

Russian Microelectronics•Dec 1, 2025•0 citations

Photon-Number Resolving by Superconductive Devices

L. Lolli

Strong interests on optical quantum based metrology, quantum information and particularly in quantum cryptography are continuously growing. The main limitations to the developments in these fields are due to non-ideal devices: both single photon sources and single photon detectors. In these field of applications, detectors require to be able to resolve the number of photons in a light pulse. Presently state of the art indicates that classical semiconductor light detectors (i.e. avalanche photodiode or single photon avalanche diode) are not able to discriminate the number of photon arriving at the same time. In the meanwhile, superconducting devices have shown the possibility to resolve single photon pulses. One of the most promising superconducting detectors is the Transition-Edge Sensor (TES): a microcalorimeter that takes advantage of the sharp transition (few millikelvin) from the superconducting to the normal phase; for this reason it is sometimes called Superconductive Phase Thermometer (SPT). In the ultraviolet (UV) to infrared (IR) wavelength range, the photons are absorbed directly by the superconductive thin film and the absorbed energy induces an increase of the TES resistance. Thanks to the applied bias voltage, which maintains the device in the transition region the photon absorption induces a decrease of the TES current, measured by a dc-SQUID amplifier, and the pulse integral of the bias power reduction corresponds to the absorbed energy. This means that TESs have the very interesting properties to be able to detect single photons with an intrinsic energy resolution, without filters or gratings, that limit the quantum efficiency. By contrary of classical detectors, if monochromatic light irradiates TESs, as usually happens in communication systems, they show the photon-number resolving (PNR) capability and due to the good signal to noise ratio TESs are almost free from dark counts. Moreover, in the superconducting detector family, TESs are the only true photon-number resolving detectors operating in the VIS-NIR range. Together with quantum information science, the PNR property results useful even for optical radiometry too. In the optical community, the candela - the International System (SI) unit for the luminous intensity - has not a common consensus whether its present definition fully satisfies the current and future needs of growing associated technology. Furthermore, actually there are substantial efforts directed toward a new definitions of four base SI units: the proposal wants to link the SI units to fundamental constants, leaving f.i. material artifact. Considering the recent advances in optical radiometry and in quantum technologies, for the candela world it means redefine its unit linking to the Planck constant and consequently expressing the luminous intensity unit in terms of photon number rather than optical power. This challenge has been accepted by several national metrology institutes to demonstrate the feasibility of redefining the candela. Inside this research project called `qu-candela', the TES PNR capability has been considered to build the bridge between the quantum and classical world of radiometry: i.e. the detector possibility to measure optical powers from one single photon per second to the lower limits of cryogenic radiometry, 104 photons per second. The theme of this work of thesis is to investigate both optical and electrical characterization of different kind of TESs based on a titanium/gold multilayer film, produced and developed at the National Institute of Metrological Research (INRIM) of Torino. Thanks to the proximity effect, the multilayer allows to lower with continuity the critical temperature from that of the Ti bulk (Tc ~ 390 mK) to those of interest: ~ 300 mK and ~ 100 mK. Detectors with higher Tc have shown a faster response pulse with a relaxing time constant of the order of 200 ns, while for the lower Tc sensors, the time constant is about 10 µs. By contrary to the response time, the detector intrinsic energy resolution is proportional to its film critical temperature. Our sensors work to discriminate incident photon from UV wavelengths to those typical of the telecommunications, 1310 nm and 1550 nm. Irradiating a TES with an active area of 10x10 µm^2 by incident photons of 0.79 eV (corresponds to a wavelength 1570 nm), the best energy resolution obtained has been 0.18 eV. Detectors with higher active area 20x20 µm^2 have a worse energy resolution, because it is also proportional to the material film heat capacity. In the meanwhile due to the same reason these kind of sensors present a bigger saturation energy. This has allowed to investigate on the TES capability to discriminate up to 29 incident photons simultaneously. Until now, such count represents the bigger amount of photons discriminated by single photon detectors, without reaching the device saturation, with a linear behaviour. From this count it has been estimated 12 photons on average, per pulse, at 9 kHz repetition rate; this results in a photon flux of about 105 photons/s, demonstrating the possibility of having a detector able to work from low flux regime to 1 photon/s to flux measurable by conventional semiconductor device (f.i. single photon avalanche detector SPAD). An innovative absolute calibration technique for PNR detector has been demonstrated. The absolute technique is based on the Klyshko's efficient solution to measure detection efficiency in photon counting rate and well know for common click-no-click detector. In fact, exploiting the recent developments in quantum state world, it is possible to work with quasi single photon state, by using a parametric down conversion heralded single photon source, and calibrate PNR detectors without requiring reference standards. The best detection efficiency, of ca. 50%, has been reached by coupling the smaller active area detectors with a 9 µm core optical fiber, single mode at telecom wavelengths

•Jan 1, 2012•0 citations
Photon-number-resolving (PNR) detection allows for the direct measurement of the Wigner quasi-probability distribution of an optical mode without the need for numerically processing an inverse Radon transform [Phys. Rev. Lett.76, 4344 (1996)10.1103/PhysRevLett.76.4344PRLTAO0031-9007]. In this work, we reproduced the seminal experiment of Banaszek et al. [Phys. Rev. A60, 674 (1999)10.1103/PhysRevA.60.674PLRAAN1050-2947] of quantum tomography of a pure coherent state, and of a statistical mixture thereof, and extended it to the more general case of photon fluxes with much more than one photon per detection time. This was made possible by the use of a superconducting transition-edge sensor to perform PNR detection from zero to five photons at 1064 nm, at ∼70% system efficiency and with no dead time. We detail signal acquisition and detection efficiency and discuss prospects for applying such quantum tomography to non-Gaussian states.
Quantum state engineering and state characterization is a key task in quantum information processing in both discrete and continuous variable systems in the optical domain. In particular, quantum states with non-Gaussian (i.e., non-positive) Wigner quasiprobability distribution functions are crucial to universal, fault-tolerant quantum computing with continuous variables. In this talk, we present our recent results on single-photon Fock state tomography using Photon-Number-Resolving (PNR) measurements. We generated a highly pure narrow-band single-photon Fock state by heralding cavity-enhanced spontaneous-parametric-downconversion from a PPKTP optical parametric oscillator. The Wigner function was reconstructed with photon statistics obtained using superconducting transition-edge sensors with an overall system efficiency of 58(2)%. We then discuss quantum state engineering for pure displaced single-photon Fock states, optical cat states, and approximate GKP states using coherent states and single-photon states along with linear optics and PNR measurements. We report our experimental progress for the same.
Characterization of quantum states and detectors is a key task in rapidly emerging optical quantum science and technology. First, we introduce and experimentally demonstrate a noise-robust quantum state characterization protocol using photon-number-resolving (PNR) measurements. Unlike conventional continuous variable state tomography methods, our method utilizes computationally efficient semi-definite programming (SDP) and can be used to accurately reconstruct the state even after loss a known loss. The protocol is demonstrated for a weak coherent state as well as a single-photon Fock state. Next, we propose a method for characterizing a photodetector by directly reconstructing the Wigner functions of the detector’s Positive-Operator-Value-Measure (POVM) elements via weak-field homodyne technique. We also report our experimental progress on characterizing a superconducting transition-edge sensor for PNR measurements.
Strong interests on optical quantum based metrology, quantum information and particularly in quantum cryptography are continuously growing. The main limitations to the developments in these fields are due to non-ideal devices: both single photon sources and single photon detectors. In these field of applications, detectors require to be able to resolve the number of photons in a light pulse. Presently state of the art indicates that classical semiconductor light detectors (i.e. avalanche photodiode or single photon avalanche diode) are not able to discriminate the number of photon arriving at the same time. In the meanwhile, superconducting devices have shown the possibility to resolve single photon pulses. One of the most promising superconducting detectors is the Transition-Edge Sensor (TES): a microcalorimeter that takes advantage of the sharp transition (few millikelvin) from the superconducting to the normal phase; for this reason it is sometimes called Superconductive Phase Thermometer (SPT). In the ultraviolet (UV) to infrared (IR) wavelength range, the photons are absorbed directly by the superconductive thin film and the absorbed energy induces an increase of the TES resistance. Thanks to the applied bias voltage, which maintains the device in the transition region the photon absorption induces a decrease of the TES current, measured by a dc-SQUID amplifier, and the pulse integral of the bias power reduction corresponds to the absorbed energy. This means that TESs have the very interesting properties to be able to detect single photons with an intrinsic energy resolution, without filters or gratings, that limit the quantum efficiency. By contrary of classical detectors, if monochromatic light irradiates TESs, as usually happens in communication systems, they show the photon-number resolving (PNR) capability and due to the good signal to noise ratio TESs are almost free from dark counts. Moreover, in the superconducting detector family, TESs are the only true photon-number resolving detectors operating in the VIS-NIR range. Together with quantum information science, the PNR property results useful even for optical radiometry too. In the optical community, the candela - the International System (SI) unit for the luminous intensity - has not a common consensus whether its present definition fully satisfies the current and future needs of growing associated technology. Furthermore, actually there are substantial efforts directed toward a new definitions of four base SI units: the proposal wants to link the SI units to fundamental constants, leaving f.i. material artifact. Considering the recent advances in optical radiometry and in quantum technologies, for the candela world it means redefine its unit linking to the Planck constant and consequently expressing the luminous intensity unit in terms of photon number rather than optical power. This challenge has been accepted by several national metrology institutes to demonstrate the feasibility of redefining the candela. Inside this research project called `qu-candela', the TES PNR capability has been considered to build the bridge between the quantum and classical world of radiometry: i.e. the detector possibility to measure optical powers from one single photon per second to the lower limits of cryogenic radiometry, 104 photons per second. The theme of this work of thesis is to investigate both optical and electrical characterization of different kind of TESs based on a titanium/gold multilayer film, produced and developed at the National Institute of Metrological Research (INRIM) of Torino. Thanks to the proximity effect, the multilayer allows to lower with continuity the critical temperature from that of the Ti bulk (Tc ~ 390 mK) to those of interest: ~ 300 mK and ~ 100 mK. Detectors with higher Tc have shown a faster response pulse with a relaxing time constant of the order of 200 ns, while for the lower Tc sensors, the time constant is about 10 µs. By contrary to the response time, the detector intrinsic energy resolution is proportional to its film critical temperature. Our sensors work to discriminate incident photon from UV wavelengths to those typical of the telecommunications, 1310 nm and 1550 nm. Irradiating a TES with an active area of 10x10 µm^2 by incident photons of 0.79 eV (corresponds to a wavelength 1570 nm), the best energy resolution obtained has been 0.18 eV. Detectors with higher active area 20x20 µm^2 have a worse energy resolution, because it is also proportional to the material film heat capacity. In the meanwhile due to the same reason these kind of sensors present a bigger saturation energy. This has allowed to investigate on the TES capability to discriminate up to 29 incident photons simultaneously. Until now, such count represents the bigger amount of photons discriminated by single photon detectors, without reaching the device saturation, with a linear behaviour. From this count it has been estimated 12 photons on average, per pulse, at 9 kHz repetition rate; this results in a photon flux of about 105 photons/s, demonstrating the possibility of having a detector able to work from low flux regime to 1 photon/s to flux measurable by conventional semiconductor device (f.i. single photon avalanche detector SPAD). An innovative absolute calibration technique for PNR detector has been demonstrated. The absolute technique is based on the Klyshko's efficient solution to measure detection efficiency in photon counting rate and well know for common click-no-click detector. In fact, exploiting the recent developments in quantum state world, it is possible to work with quasi single photon state, by using a parametric down conversion heralded single photon source, and calibrate PNR detectors without requiring reference standards. The best detection efficiency, of ca. 50%, has been reached by coupling the smaller active area detectors with a 9 µm core optical fiber, single mode at telecom wavelengths